| 1 | Dismantling tile work in floors and roofs laid incement mortar including stacking material within 50metres lead. For thickness of tiles 10 mm to 25 mm |
| 2 | Demolishing cement concrete manually / bymechanical means including disposal of materialwith all lifts and upto 50 m lead etc. complete as perdirection of the Engineer- in-charge:-Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Providing and laying in position cement concrete ofspecified grade excluding the cost of centring andshuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brickaggregate 20 mm nominal size) |
| 4 | Providing and laying 1st class quality vitrified floor tilesin different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% andconforming to IS: 15622 - 2017, of approved make, in allcolours and shades, laid over 20mm thick cement mortar1:4 (1 cement : 4 fine sand), jointing with grey cementslurry @ 3.3 kg/ sqm including grouting the joints withwhite cement and matching pigments etc. all complete asper direction of the Engineer-in-charge..Double charged Stainfree vitrified tiles (Glossy) Size of tile 600 mm x 600 mm |
| 5 | Providing and fixing M.S. grills of required pattern inframes of windows etc. with M.S. flats, square orround bars etc. all complete. Fixed to steel windows by welding. |
| 6 | Dismantling GS sheet roofing including ridges, hips,valleys, gutters wind ties etc. includingdismembering and stacking of serviceable materialsand unserviceable materials separately with all liftsand upto a lead of 50 m etc.complete as per directionof the Engineer- in-charge. |
| 7 | Dismantling steel work in built up section manually/ mechanically without dismembering and stackingof serviceable materials and unserviceable materialsseparately with all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer- in-charge. |
| 8 | Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., includingcutting, hoisting, fixing in position and applying apriming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 9 | Providing corrugated G.S. sheet roofing includingvertical/curved surface fixed with polymer coated Jor L hooks, bolts and nuts 8 mm diameter withbitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead and including a coatof approved steel primer and two coats of approvedpaint on overlapping of sheets complete (up to anypitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever requiredetc. complete as per direction of Engineer-in-charge.0.63mm thick with zinc coating not less than 275gm/m2 |
| 10 | Providing 40 × 5 mm flat iron hold fast 40 cm longincluding fixing to frame with 10 mm diameter bolts,nuts and wooden plugs and embedding in cementconcrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3fine sand : 6 graded stone aggregate 20mm nominalsize) |
| 11 | 12 mm cement plaster of mix.Cement mortar 1:4 (1 cement : 4 fine sand) |
| 12 | Providing and fixing 1mm thick M.S. sheet door withframe of 40x40x6mm angle iron and 3mm M.S. gussetplates at the junctions and corners, & with cleats withbolts & nuts, rivets, locking arrangement, handles, hooks& eyes, pinlets including embedding in cement concreteof required grade for fixing in position, all necessaryfittings, including applying a priming coat of approvedsteel primer etc. complete as required:-Using M.S. angels 40x40x6 mm for diagonal braces. |
| 13 | Steel work welded in built up section/framed workincluding cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer usingsteel etc. complete as required:-In grating, frames, guard bar, railing, brackets, gates andsimilar works, all complete. |
| 14 | Dismantling rolling shutters with all accessories andstacking properly and refitting the same after oiling andgreasing the same with necessary cement concrete forfitting fixing of hold fasts etc. for all lifts and upto alead of 50 m as required complete as per direction ofthe Engineer in charge.Wheel 50 mm dia and below |
| 15 | Finishing with epoxy paint ( one or more coats ) ofapproved brand and manufacture at all locationsprepared and applied as per manufacturer'sspecification on old work including preparation ofsurface etc. as required complete as per direction of theEngineer in charge:- On steel work. |
| 16 | Providing & fixing glass panes with putty and glazingclips in steel doors, windows, clerestory windows, allcomplete with :5.5 mm thick glass panes |
| 17 | Providing wood work in frames of false ceiling,partitions etc. sawn and put up in position :Local Teak Wood |
| 18 | Ply wood 5 ply, 9 mm thick :Decorative plywood one side decorative veneer andcommercial veneer on other face (Type 1) conforming toIS 1328 BWR Type |
| 19 | Distempering with 1st quality washable acrylicdistemper of approved brand and manufacture and ofrequired shade on old work ( one or more coats ), togive an even shade as required complete as perdirection of the Engineer in charge. |
| 20 | Finishing walls with textured exterior paint of requiredshade of approved brand and manufacture on old work( one or more coats ) including preparation of surface asrequired complete as per direction of the Engineer incharge. Please Enable Macros to View BoQ information |