| 1 | Scraping of white wash |
| 2 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 3 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing downold paint. |
| 4 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 5 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 6 | Cleaning of terazzo floors with tartaric acid with granite finish including machine charge. |
| 7 | Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded). |
| 8 | Scraping of Cement plaster |
| 9 | 12.5 mm thic Cement Plaster 1:5 |
| 10 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm 4mm thick or 10.78 Kg/ sqm |
| 11 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm |
| 12 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999)) Decorative with elm or gurjan facing on one side and teak facing on the other side edges lipped with teak with laminated core 35mm thick |
| 13 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area up to 0.50 sqm |
| 14 | Cement Conc. 1:2:4 using Shingle or ballast by Manual means |
| 15 | Electrical Work RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring light point |
| 16 | Wiring call-bell point |
| 17 | Wiring 6 Amp. wall socket point |
| 18 | Wiring 16/20 amp. power plug control point |
| 19 | SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½\\" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:-Wiring light point |
| 20 | REPLACEMENT OF WIRES, COVER FRAMES, MODULAR SWITCHES, CONCEALED METAL BOXES AND OTHER ACCESSORIES IN THE EXISTING RECESSED CONDUIT PIPE WIRING SYSTEM (WITH MODULAR TYPE ACCESSORIES) Derived from 34.01: Replacement of PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in existing heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), PVC Bush, bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (Derived From CSR 34.01)Wiring fan point (without fan box ) |
| 21 | Wiring light point |
| 22 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (NSR ITEM)Supply and Erection of Computer Point with 8 Module Sheet Metal Box and 8 Module Cover Plate with 2 Nos. 6A Switch Modular and 3 Nos. 6A Socket (Two Module) covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface). Complete in all respect as per satisfaction of engineer in charge at site. |
| 23 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- (NSR ITEM)Supply and Erection of Air Conditioner Point with 32A DP Switch, 2 Module Sheet and 2 Module Cover Plate with 16A Socket covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface). Complete in all respect as per satisfaction of engineer in charge at site. |
| 24 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring Telephone socket point RJ11 (one module) |
| 25 | Wiring Networking socket point RJ45 (one module) |
| 26 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) |
| 27 | Overall size 2.5sq.mm (Un-sheathed) |
| 28 | Overall size 4sq.mm (Un-sheathed) |
| 29 | Overall size 6sq.mm (Un-sheathed) |
| 30 | Overall size 10sq.mm (Un-sheathed) |
| 31 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 120sq.mm (3½ Core) Un-armoured (Loose) |
| 32 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 33 | HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 34 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 35 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 36 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-PVC flexible pipe 25mm dia. |
| 37 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 38 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 39 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 40 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-SP&N Double Door Distribution Board 12 way each |
| 41 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 42 | INDOOR LT PANELS: LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel.The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work .Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports.Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc.Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:-SUB LT PANEL (NORMAL): LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB's 40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) |
| 43 | MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etcMCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 44 | MCCB Four Pole 250amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 45 | Supply and erection of Copper Chemical Earthing 3 meter long earthing rod typically has a copper-bonded steel rod with a minimum 250-micron copper coating, a diameter ranging from 14 mm to 50 mm or more, and a high tensile strength of around 90,000 psi. For installation, it is placed in an augured hole, surrounded by earth enhancing compound, and often interconnected with other electrodes using a 25x2mm copper strip or 8mm solid copper conductor, buried at least 500 mm deep. Complete in all respect as per satisfaction of engineer in charge at site. |
| 46 | Supply and Erection of Ceiling fan Suitable size 56” (1400mm) including connection & testing complete in all respects as desired by the Engineer in charge of work at site. BASIC FEATURES:- Ceiling Fan, Blade sweep :1400mm (56\\"), Fan motor : A. C. permanent capacitor single phase induction motor, Capacitor rating :2.25mfd. 440 volts, 50Hz A.C., Rated Voltage :220-240 Volts, 50 Hz, single phase A. C., Test Voltage :230 Volts, 50 Hz, single phase A. C., Rated frequency :50 Hz, Rated power input at full speed :75 Watts, Rated current at full speed :0.33 A, Rated power factor :0.9 lagging (min), Rated speed in rpm : 400 RPM, Rated air delivery in Cu.m / Min :230 Cu.m / Min, Rated service value in Cum /min/ W :3.19 Cum /min/ W, No. of blades : Three, Type of blade leaf :1.08 mm thick aluminium sheet, Type of regulator : Resistance type, No. of running positions :5 + off positions, Type of switch : Rotary type, Speed : Min. 50% of full speed (approximately), Class of motor insulation : Class\\" B\\", No of bearings : Two ball bearings. Complete in all respects as desired by the Engineer in charge of work at site. |
| 47 | Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48” (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos. of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM. Complete in all respects as desired by the Engineer in charge of work at site. |
| 48 | Supply and Erection of Heavy Duty Exhaust Fan Suitable size 12” (300mm) including Louver shutter, connection & testing complete in all respects as desired by the Engineer in charge of work at site. Exhaust Fan, Blade Sweep : 300 mm (12”), Type of motor : Permanent capacitor induction motor, C75 Rated Voltage : 230 volts, 50 Hz, AC. single Phase, Test voltage : 230 volts, 50 Hz, .AC. I Phase, Frequency : 50 Hz., Capacitor rating : 1.0 F, 400V, 50 Hz, AC., Rated watts at full (load) speed & at 230V. : 27 watts., Current in amps at full speed & at 230 V. : 0.12 Amps., Power factor : 0.9 min., Rated full speed & at 230 V : 1310 rpm., Rated air delivery at 230 V : 800 M3/hr, Rated Service value : 30 m3/hr/watt, No. of blades leaves : Five, Type of blade leaf : Plastic (PP), No of running positions : One position, Class of Insulation : Class “E”, Type of bearings : Oil impregnated self aligned bush bearings. |
| 49 | Supply and Erection of 36 Watt 2X2 Surface mounted LED Luminaire (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. |
| 50 | Supply and Erection of 24 Watt Surface mounted LED edge lit slim downlight with a durable PDC aluminum body and frosted diffuser, it ensures uniform illumination and asleek, modern aesthetic for various applications.. Efficacy:100 lm/W. Complete in all respects as approved and desired by the Engineer in-charge at site. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. |
| 51 | Supply and Erection of 15 Watt Surface mounted LED edge lit slim downlight with a durable PDC aluminum body and frosted diffuser, it ensures uniform illumination and asleek, modern aesthetic for various applications.. Efficacy:100 lm/W. Complete in all respects as approved and desired by the Engineer in-charge at site. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. |
| 52 | Supply and Erection of 36/40 Watt LED Batten Light fitting. (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the Lighting Fixture manufacturer should have inhouse NABL accredited LAB. |
| 53 | Public Health Work Providing and fixing in position Chinaware Indian Orisa water closet sizes 580mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of engineer in charge. |
| 54 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 55 | With C.P. Brass nut |
| 56 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.Size 550 mm x 400 mm x 815 mm |
| 57 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 58 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 6 pegs |
| 59 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 60 | Providing & Fixing in position plastic moulded frame mirror Size 550mmx400mm with 4mm thick hard board backing of required shape fixed in position with rawl plugs, C.P. brass screws and washers complete in all respect |
| 61 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect.C.P. brass Bib cock long nose/ long body foam flow without flange |
| 62 | C.P.brass 15mm Concealed stop cock with flange. |
| 63 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect.C.P.brass 15mm Angle valve without flange |
| 64 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut |
| 65 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 66 | Provising & placing in postion on terrace (at all floor levels) HDPE water storge tanks of approved make (to the approved of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet,outlet and over flo pipes but without fitting and base support for tanks.Triple Layer Tanks (1000 x 19) |
| 67 | Providing, fixing and jointing G.I Union Couplings (of approved make with the approval of EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.20mm i/d G.I. Union |
| 68 | 25mm i/d G.I. Union |
| 69 | Providing, fixing and jointing gun-metal peet valves (Heavy Pattern) with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.20mm |
| 70 | Providing and fixing C.P. brass 32mm long bend complete |
| 71 | Providing & Fixing in position automatic brass ball valves in tanksPlastic Ball cock with rod and plastic ball20mm i/d |
| 72 | Providing and fixing in position G.I tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC water storage tank complete in all respect.G.I tank nipple 20mm i/d |
| 73 | G.I tank nipple 25mm i/d |
| 74 | Providing and fixing PVC Cistern 10 Ltr. Capacity ISI marked IS 7231:1994( size 32.5x47.6x15.5 cm) of approved make(to the approval of the Engineer-in-charge) including PVC fittings complete. |
| 75 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 76 | Providing and fixing brick masonry platform for storage tank. |
| 77 | Providing and fixing in position paper holders of approved make (to the approval of Engineerin- charge) fixed in to wall with C.P brass screws complete in all respect.C.P. brass toilet paper holder |
| 78 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 79 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. Please Enable Macros to View BoQ information |