| 1 | PART A CIVIL WORK |
| 2 | Dismantling brick tiles covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In mud mortar |
| 4 | Demolishing mud phuska/ Lime dhar/ Kharanja in terracing and disposal of unserviceable material within 50 meters lead. |
| 5 | Dismantling Jack Arch roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50-meter lead. |
| 6 | Dismantling Stone Slab roofing and floors including stacking of serviceable material and disposal of unserviceable material within 50-meter lead. |
| 7 | Dismantling steel work in single sections including dismembering and stacking within 50 meters lead in:R.S. Joists. |
| 8 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead: Of area 3 square meter and below. |
| 9 | Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 10 | Roof Slab & Beams :- Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 11 | Roof Slab & Beam :- Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 12 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 13 | 6 mm cement plaster to ceiling of mix 1:3 (1 cement :3 corse sand) |
| 14 | Internal Plaster--Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished. 12mm Thick |
| 15 | External Plaster -Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished. 20 mm thick |
| 16 | Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 17 | Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. |
| 18 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Door and chokhat 40 x 40 x 5 mm |
| 19 | Providing And Fixing Steel Glazed Doors Windows And Ventilator With Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x13 Mm, 10 Cm. Long Embedded In Cement Concrete Block 15x10x10 Cm Of 1:3:6 (1 Cement:3 Course Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screw Or Rawl Plungs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing Adn Fixing Of Plain Glass Panes 4 Mm Thick With Coper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including The Cost Of Metal Beading And Other Fitting Except Necessary Hings Of Pivots Steel Handles Peg Stay Etc. As Required partially fixed and partially openable(fixed area not to exceed 33%) |
| 20 | P&F M.S. Sheet DoubleLeaf Door Shutter In Angle Iron Frame 35 x35 x 5mm Suitability Diagonally Braced With 25*3mm Flat Iron Above And Below Lock Rail Of Size 50 x 5mm Beading Extra Including All Fittings As Per Direction Of Chokhats But Excluding Cost Of Chowkhats M. S. Sheet 18SWG |
| 21 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 22 | Providing and fixingxed wire gauge of 14 meshx24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 23 | P&L 25 mm thick Polished blue kota stone flooring Skirting laid Over 20 mm thick base of CM 1:4 & jointed with grey cement slury math the shade of slabe incld rubbing and polishing complete. Size 2001 to 5000 sq.cm |
| 24 | P&L 25 mm thick Polished blue kota stone flooring Skirting laid Over 20 mm thick base of CM 1:4 & jointed with grey cement slury math the shade of slabe incld rubbing and polishing complete. Size upto 2001 sq.cm |
| 25 | PART B SANITARY WORK |
| 26 | P&F rigid 110 mm dia pvc pipe class IInd (4kg./cm2) approved quality make including jointing the pipe with solvent cement rubber rim & lubricant . |
| 27 | PART C ELECTRIC WORK |
| 28 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR |
| 29 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 2 x 2.5 sq. mm.+1X1.5 sq mm |
| 30 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Please Enable Macros to View BoQ information |