| 1 | Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sites and raming of bottoms at the site, etc., complete complying with standard specification and as directed by the departmental officers.For upto 2.40m Depth |
| 2 | Earth work excavation for foundation by manual means for RR/Brick and Other step type footings for Load bearing structures in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. |
| 3 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. A). Upto 2.40m Depth. |
| 4 | b)Above 2.40m Depth. |
| 5 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 6 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. |
| 7 | Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 8 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means |
| 9 | Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by mechanical means |
| 10 | Damp proof course as per IS 3067:1988 with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality Integral liquid water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used , finishing and curing etc. complete complying with standard specification - Machine Mixing |
| 11 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 12 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid)-a).RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks |
| 13 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). ( Slab )-a). RCC Floor Slab, Roof Slab, Loft, Landing Slabs |
| 14 | Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid) |
| 15 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. using mild steel sheets of size 1200cm x 60cm and 10 BG stiffened with welded mild steel angles of size 40mm x 40mm x 5 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals. MS Channel Section (ISMC 100) shall be provided as a vertical support @1.20m C/C and with Lateral support of Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) & steel pipes of 20mm dia @ required level/spacing etc. complete complying with standard specifcation and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid) |
| 16 | Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456- 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc.,complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 17 | For Foundation & Basement |
| 18 | For Super Structure in Ground Floor |
| 19 | For Super Structure in First Floor |
| 20 | For Super Structure in Second Floor |
| 21 | For Super Structure in Third Floor |
| 22 | For Super Structure in Fourth Floor |
| 23 | Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). |
| 24 | For Foundation & Basement |
| 25 | For Super Structure in Ground Floor |
| 26 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers- mixing by mechanical means- for foundation & basement. |
| 27 | Cement Concrete 1:3:6 (One Cement, Three crushed stone sand and Six broken stone jelly) using 20mm size hard broken stone jelly for dummy columns,etc., excluding cost of centering shuttering reinforcement grills and fabrication charges but including Cost of Mortar Plasticizer, curing etc. complete and as directed by the departmental officers. (Dummy columns should be at least 1 metre height)-Mixing by mechanical means |
| 28 | For Second Floor |
| 29 | For Fourth floor |
| 30 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC Roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 31 | For Ground Floor |
| 32 | For First Floor |
| 33 | For Third Floor |
| 34 | For Fourth floor |
| 35 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 36 | For upto Plinth/Basement level |
| 37 | For Super Structure in Ground Floor |
| 38 | For Super Structure in First Floor |
| 39 | For Super Structure in Second Floor |
| 40 | For Super Structure in Third Floor |
| 41 | For Super Structure in Fourth Floor |
| 42 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of neceSORy PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC Roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of “U” clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers . |
| 43 | For One Floor-160 mm dia pipe |
| 44 | For two Floor-160 mm dia pipe |
| 45 | For Four Floors-160 mm dia pipe |
| 46 | For One Floor-110 mm dia pipe |
| 47 | Brick work in Cement Mortar 1:5(One cement and Five M.Sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge |
| 48 | For Foundation and Basement |
| 49 | For Ground floor |
| 50 | Brick work in Cement Mortar 1:6(One cement and Six M.Sand) using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge |
| 51 | For Super Structure in Ground Floor |
| 52 | For Super Structure in First Floor |
| 53 | For Super Structure in Second Floor |
| 54 | For Super Structure in Third Floor |
| 55 | For Super Structure in Fourth Floor |
| 56 | Brick partition walls of 11.50cm thickness using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 57 | For Super Structure in Ground Floor |
| 58 | For Super Structure in First Floor |
| 59 | For Super Structure in Second Floor |
| 60 | For Super Structure in Third Floor |
| 61 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 62 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 63 | Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 64 | Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 65 | Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. |
| 66 | Manufacturing supplying of Stainless Steel (Salem Stainless Steel) Door Frame - Box Section using Stainless Steel Plate with 1 mm thickness with the size of 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel Hold fast etc including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc complete complying with standard specification and as directed by the departmental officers - SS Door Frame with thickness of 1mm |
| 67 | Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.Type: Commercial ply on both sidesTHickness: 35m |
| 68 | Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 6 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 3 Nos. 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Double leaf.Type: Commercial ply on both sidesTHickness: 35m |
| 69 | Supply & fixing of WPC (Wood Polymer Composite) Frame extruded with size 75mm x 50mm. The single core door made of rigid WPC compound with minimum Bulk Density of 900 KG/ Cub.Mt. & shore hardness of 55. Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/ Cub.Mt. & shore hardness of 55. For the aesthetic appearance, the door shall be a printed digitally on one side of the shutter and the design is as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the WPC frame with 3 Nos of 5” SS Hinges and the door shall have 2 towerbolt on one side and 1 towerbolt or aldrop on other side for locking system and 2 numbers of handle on the either side of the door shutter, all made of aluminium. |
| 70 | Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS (Sliding door) etc., complete and as directed by the departmental officers. |
| 71 | UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 72 | Supply and installation of three-track sliding uPVC windows shall utilize uPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 112mm x 52mm x 112mm, a shutter of 66mm x 42mm x 50mm, an interlock of 45mm x 36mm, and a glazing bead of 24.5mm x 16mm. All profiles of frames, sash, and mullion shall be reinforced, wherever required, with a 1mm thick GI steel section. Each window is to be equipped with various security devices, such as touch locks or crescent locks, along with nylon rollers and an aluminium track for smooth operation, all supplied as per requirements, compliant with relevant specifications, and as directed by departmental personnel. The windows shall incorporate 5mm thick Plain or Pinhead glass, held securely by TPE (Grey) weather-sealed gaskets. All corners and mullion joints of the frame and sash are to be mitred cut and fusion welded without any mechanical joints, with all welded joints neatly trimmed and finished with a grooved nib to ensure the final products are free from sharp edges. The complete window units shall be fixed into pre-finished openings by drilling and fastening through the outer frame using highquality fasteners, and silicon sealant will be applied to fill the gap between the wall and window frame for a leak-proof installation and complete finish etc., Complete and as directed by the department officers. |
| 73 | UPVC Ventilator Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Ventilator of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 74 | Supply and erection of Double Leaves Fire Rated Door with Frame having the dimension of 1800mm x 1400mm with following specification:a. Door Frame 1.6mm: Galvanized 120 GSM branded make JSWb. Door Leaf 1mm: Galvanized 120 GSM branded make JSWc. Shutter Thickness: 46mmd. Honeycomb: In-fille. Glue Macroplast UR-7221f. Door Hinges: 4” x 3” x 3mm, Double Ball: Make Assa Abloy Yale Ball bearing Butt Hinges Grade SS 304 - Finish SSg. Door Closer with Standard Arm Finish: Silverh. Lock Set: Dead Lock with both side keyi. Door Orientation: To be confirmed by clientj. Mounting of door: Brick wall mountedk. Powder Coating: Powder coated in standard RAL paint colour of PO Red (60 to 90) Micronsl. Single Point Panic Bar (2 Horizontal): Make Assa Abloy Yale or Equivalentm. Dead Lock with both side key: Make Assa Abloy Yale or Equivalentn. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frameo. Rated Glass Schott Pyran with Framep. Anchor Bolt with EndcapsThe above assembly mounted on concrete or brick wall including the cost of cutting, chipping, concrete packing, pastering, scaffolding all other conveyence as per standard methods and as directed by the Departmental Officers. |
| 75 | Supplying and erecting pull and push type rolling shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc., ROLLING SHUTTERS (WITH ISI MONOGRAM)-Manually operated (up to 8 m2 area) |
| 76 | The supply and installation of UPVC partitions with doors shall utilize uPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 74mm x 60mm x 56mm, a shutter of 104mm x 60mm x 66mm, a mullion of 72mm x 60mm x 36mm, a glazing bead of 35mm x 18mm, a 20mm multi-chambered hollow uPVC panel section of 150mm x 20mm, and a uPVC panel bead of 19mm x 16mm. All profiles of frames, sash, and mullion shall be reinforced, where required, with 1mm thick GI steel sections. The door will be equipped with 3D hinges for enhanced weight holding capacity, and security devices such as multipoint lock systems with a cylinder lock facilitated handle, all compliant with relevant specifications and departmental directives. Glazing or uPVC panels shall be 5mm thick Plain Toughened or uPVC panel grip, held by TPE (Grey) weather-sealed gaskets. All corners and mullion joints of the frame and sash shall be mitred cut and fusion welded without mechanical joints, with all welded joints neatly trimmed to a grooved nib finish, ensuring the finished products are free from sharp edges. The complete units shall be fixed into pre-finished openings by drilling and fastening through the outer frame using high-quality fasteners, and silicon sealant shall be applied to fill the gap between the wall and the frame for a leakproof installation and completion etc., Complete and as directed by the department officers. |
| 77 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 78 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete |
| 79 | Supplying, and fixing M.S. GRILLS for open courtyard grill, grill work to doors, windows and ventilators etc, using necessary flats for inner and outer members which should be fixed or welded to masonry or column including necessary dismantling or making holes and redoing the same to original condition as directed by the departmenta officers inclusive of cost of providing one coat of best quality red oxide primer completre complying with standard specifications. |
| 80 | Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. |
| 81 | One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters. at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m. |
| 82 | Dadooing walls with following best approved quality, Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 83 | Supplying, Fabricating, erecting and fixing Calcium silicate Board FALSE CELING upto a ceiling height of 4.50 m from floor level using Calcium silicate Plain sheet 10mm thick which includes shaped GI channels of size 25 x 25 x 0.50 mm thick suspended from ceilling at 1.2 m both longitudinal and cross vertical support and fixing shaped GI channels of size 50 x 30 x 0.50 mm and 150 x 10 x 0.50 mm thick at 0.60m centre longitudinal and cross direction for vertical supports and fixing U shaped GI channels of size 50 x 30 x 0.50 mm thick and 50 x 10 x 0.50 mm thick at 0.60 m centre to centre in cross direction and respectively for horizantal supports of zig - zag pattern and fixing of Gyp board in the panel provided in the desing pattern given and sprating the standard specification and as directed by the departmental officers. The rate shall be inclusive of finishing the edges and wall junctions with suitable lipping and cornice arrangements |
| 84 | Providing Cornice Work for Gyp Board False Ceiling using plaster of paris below the existing Gyp board flase ceiling as directed and designed by the departmental officers. The rate is inclusive of cost all materials, labour charges and scaffolding charges etc., complete complying with standard specification as directed by the departmental officers. |
| 85 | Supplying and fixing of PVC trims (Beading) on wall corner, etc., complete complying with strandard specification as directed by the departmental officers. |
| 86 | Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)-Double Charged Vitrified Tiles 800 x 800 x 10mm |
| 87 | Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 and above with 20mm thick with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., complete complying with standard speicification and as directed by the departmental officers.(The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) |
| 88 | Supplying and fixing fine polished cuddapah slab of following thickness for cup- board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as directed by the departmental officers -38 / 40mm thick fine polished cuddapah slab |
| 89 | Providing Double nosing for granite etc., complete complying with standard specification and as directed by the department officers. |
| 90 | Providing and Fixing of polyurethane foam for Sloped roofas thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span , whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification (including labour charges) 80mm (+38) thick PUF roof panel |
| 91 | Flooring with Joint free rectified glazed Ceramic tiles of size 305 x 305 x 8 mm conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 92 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two Crushed Stone Sand and Four aggregate) using 6 to12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trowel, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers) 25mm thick |
| 93 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using 20mm HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed. |
| 94 | 50mm thick |
| 95 | 75mm thick |
| 96 | Finishing the top of Roof with one course of machine pressed tiles of 230 x 230 x 20mm size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water pRoofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water pRoofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 97 | Providing Grooving the Granite Slab, etc., complete complying with standard specification and as directed by the departmental officers- |
| 98 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)Dadooing with granite tiles of synthetic grey, paradise, and similar/other varieties of suitable size |
| 99 | Providing Leather finished granite slab of approved colour for Staircase Treads and midlanding including nosing free from all defts in all floors over a base layer of cement mortar 1:3 (one cement and three sand) 10 to 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Fine Polished Granite Slab of Size : 1200 x 600 of 18 / 20mm thick |
| 100 | Brick jelly Lime Concrete 1:2:5 (One lime, two sand and five brick jelly ) using 20mm gauge brick jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor finish, curing, etc. complete complying with standard specification.(For flooring in toilet portioins except water closet portions) |
| 101 | For Ground floor |
| 102 | For First floor |
| 103 | For Second floor |
| 104 | For Third floor |
| 105 | Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work. |
| 106 | Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 107 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (water proof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers.( The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc.,complete. The putty should be got approved by the Executive Engineer before use on work |
| 108 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 109 | Painting the wall with Texture Finish Paint including labour charges including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 110 | Painting the wall two coats with approved weather proof Exterior Emulsion paint over one primer coat on cement plastered wall surface ect., complete complying with standard specification and as directed by the departmental officers. |
| 111 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 112 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 113 | Supplying and fixing following Ornamental Teakwood entrance door as per the drawings and designs approved by the departmental officers. The outer frame of the door is 150mmx100mm teakwood scantling. The main door shutter opening size is 2.40mx2.40m.The main door should be double leaves and each door shutter fully panelled, the bottom rails are of size 200x50mm.Middle, top and side rails size of 150x150mm with corner designed beeding works. The outer frames are designed with border works on entrance side. The cost includes all kind of furniture fittings such as brass aldrops, brass tower bolt, brass hinges, brass door stopper, brass handles, all the members are finished with two coats of melamine polish with outer priming coat. (Quality of all furniture fittings should be got approved by the Executive Engineer before use). |
| 114 | Providing Anti-termite treatment to soil adjacent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. |
| 115 | Supplying and installation of Anutone / Topakustiks / Idea Tec / Wood Fit / Equivalent Brand of Acoustic Wooden Wall Panelling with fire retardant grade pine wood fibre slats of size 2430 x 128 x 16mm with lineal perforation of 2mm back lined with soundtex black acoustical fleece 0.27mm thick, 63 g / m2, tongue-groove edge for a seamless look, 5 test fire retardant grade with noise reduction coefficient not less than 0.75 NRC to absorb low and mid range frequencies from 125Hz to 4000Hz. GI strut CC50 frame work not more than 60 cm centre to centre using GI channels are fixed on the wall, over which an acoustic filling polywool material sound synth of 500 gsm density of 50mm thick has fixed and finally the panels are fixed and finished, so as to have an neat appearance as directed by the departmental offices. The cost includes cost of material, cost of Labours, scaffolding, transportation, conveyance, etc., complete complying to standard specication. |
| 116 | Supply and installation of Special type Anutone wood wool 15mm thick (or) Equivalent Brand of Acoustical False Ceiling of 50mm synth wool, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 20mm having volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. Skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. The subtex nubby square edge of size 595 x 595 x 20mm shall be placed into the grid size of 600 x 600mm. |
| 117 | Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specification |
| 118 | Drilling of Borewell in sedimentary strata of hard rock stone shale pebbles bolders etc., By first taking a pilot bore of 150mm dia and then enlarging to the required dia by direct or reverse rotary mud circulation method using rotary rigs, fuel labour and drilling bentonite and water required for dirlling at site. |
| 119 | upto 150m below GL |
| 120 | From 151 to 180m |
| 121 | From 181 to 210m |
| 122 | From 211 to 240m |
| 123 | From 241 to 270m |
| 124 | From 271 to 300m |
| 125 | Supplying of best approved quality of PVC casing pipe of 6\\" dia (Special Blue Pipes for Bore Well) for borewell with socket end to suit borewell of required depth -6kg/cm2 best approved quality with ISI mark with necessary PVC coupling etc., |
| 126 | Supplying and fixing of suitable PVC endcap (6kg/cm2) for 6\\" dia borewell of best quality with ISI mark etc., complete |
| 127 | Supplying and fixing of Nylon Rope for Bore-well of best quality etc., complete complying with standard specification |
| 128 | Supllying of best and approved quality of UPVC pipe 50mm dia including laying in the basement and tying with copper wire etc., complete complying with standard specification. |
| 129 | Supplying and erection of following submersible pump set with 3 panel board including labour charges of ISI make, Pumping water from open well including transportation charges, erection charges etc., complete complying with standard specification and as directed by the departmental officers. |
| 130 | 5 H.P. Submersible pump |
| 131 | 7.50 H.P. Submersible pump |
| 132 | Supplying and erection of Submersible wire 4sqmm cable PVC insulated and sheathed 3core flat type copper cable with ISI make including erection inside the bore well and open run of clamping etc., completer complying with standard specification., as directed by the departmental offcers., |
| 133 | Supplying and fixing of following size of GM Non return valve with ISI make including cost of shellac thread etc., completer complying with standard specification., as directed by the departmental officers. 50mm dia |
| 134 | Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply arrangement -Below ground level. 50mm dia UPVC Pipe |
| 135 | Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level. |
| 136 | 50mm dia UPVC Pipe |
| 137 | 40mm UPVC Pipe |
| 138 | 25mm UPVC Pipe |
| 139 | Supplying, laying and jointing CPVC pipes OF Standard Dimension Ratio 11 (Pressure class 1) conforming to IS:15778 - 2007 of approved quality and best variety of the following dia including cutting and fixing CPVC specials using CPVC adhesives (Solvent Cement) (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications and as directed by the departmental officers. (The CPVC pipes shall be got approved by Executive Engineer before use on works) - Internal water supply above ground level. |
| 140 | 25mm dia CPVC Pipe |
| 141 | 20mm dia CPVC Pipe |
| 142 | Supplying and fixing in position UPVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the UPVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The UPVC specials should be got approved by the Executive Engineer before use on works). |
| 143 | 50mm dia Elbow |
| 144 | 50mm dia Tee |
| 145 | 50mm dia Union |
| 146 | 50mm dia Bend |
| 147 | 50mm dia Coupler |
| 148 | 50mmx40mm Reducer |
| 149 | 50mm x 40mm Reducer Elbow |
| 150 | 50mm x 40mm Reducer Tee |
| 151 | 40mm dia Elbow |
| 152 | 40mm dia Tee |
| 153 | 40mm dia Union |
| 154 | 40mm dia Bend |
| 155 | 40mm dia Coupler |
| 156 | 20mmx15mm dia Reducer Tee |
| 157 | 25mmx20mm dia Reducer Elbow |
| 158 | 25mmx20mm Reducer Tee |
| 159 | Supplying CPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements etc., complete |
| 160 | 20mm dia Elbow |
| 161 | 25mm dia Elbow |
| 162 | 20mm dia Tee |
| 163 | 25mm dia Tee |
| 164 | Supplying and fixing in position 15mm dia SS Heavy Duty Long Body Tap / SS Elbow action tap of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 165 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 166 | 50mm dia Gate Valve |
| 167 | 40mm dia Gate Valve |
| 168 | 25mm dia Gate Valve |
| 169 | Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. |
| 170 | (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat coverWall Fitting |
| 171 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 172 | Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 173 | Supplying and fixing best quality and make of PVC water storage tanks having 1000 litres capacity -made of PVC materials- including necessary provision for conveying, jointing delivery line, scour pipe, over flow pipe etc., and lifting the tank to the top of the building placing in position etc., complete as directed by the departmental officers. (The plastic water storage tank should be got approved by the Executive Engineer before fixing in position.) |
| 174 | Supplying and erecting in position of following 250 lit capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact etc., complete |
| 175 | Supplying and fixing in position of best quality of Chemical coated Foamcore and underground PVC Soil / waste pipes of various dia having pressure and SN8 KN/m2 with BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The Chemical coated foamcore PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid - 250mm dia PVC Pipe |
| 176 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid Above fround level |
| 177 | 75mm dia PVC Pipe |
| 178 | 110mm dia PVC Pipe |
| 179 | 160mm dia PVC Pipe |
| 180 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 181 | 110mm dia PVC \\"Y\\" with Single door |
| 182 | 110mm dia PVC \\"Y\\" with Double door |
| 183 | 110mm dia PVC Tee |
| 184 | 75mm dia \\"Y\\" with Single door |
| 185 | 75mm dia PVC Tee |
| 186 | 110mm dia PVC bend |
| 187 | 75mm dia PVC bend |
| 188 | 75mm dia PVC \\"Y\\" with Double door |
| 189 | 250x160 reducer |
| 190 | Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works). |
| 191 | 75mm dia PVC Cowl |
| 192 | 110mm dia PVC Cowl |
| 193 | Supplying and fixing in position Stainless steel Health Faucet etc., complete complying with standard specification. |
| 194 | Supplying and fixing position Nahani Trap of size 100 x 75mm with stainless steel gratings / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 195 | Supplying and fixing approved best quality Stainless steel towel rack 600mm long with lower hanger including cost of materials conveyance etc., with standard specification. and as diceted by the deaprtmental officers. |
| 196 | Supplying and fixing in poisition special square type SS Shower rose of size 15 x 15 cm with SS stop cock. including cost of materials conveyance etc., with standard specification. and as diceted by the deaprtmental officers. |
| 197 | Supplying and fixing in poisition 15 mm dia brass Delux model SS Shower Arm with ss stop cock. including cost of materials conveyance etc., with standard specification. and as diceted by the deaprtmental officers. |
| 198 | supplying and fixing if marble of 0.61*1.22m.,18/20mm thick in all floors for urinal partition including for labour charges for fixing and polishing etc., |
| 199 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 200 | Supplying and fixing best approved best quality Procelain CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works). |
| 201 | Supplying and fixing in position of Steel ladder of width 45 cm using MS Angle of 50 x 50 x 6mm thick for frames and steps including cutting, granding, welding, and making charges etc., complete complying with standard specification and as diceted by the deaprtmental officers. |
| 202 | Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Fly ash Brick of size 230x110x70mm with class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification.-600 x 600mm |
| 203 | Supplying and fixing in position first quality and approved varity with ISI mark SFRC man hole cover of following size of complete complying with standard specification |
| 204 | 600x 600mm |
| 205 | 900 x 900mm |
| 206 | Supplying and fixing of White Glazed Porcelain Oval Shape Special Type Urinal of size 382 x 398 x 601mm etc., complete |
| 207 | Supplying and fixing of Granite Sink of size 600 x 600 x 250mm with 32mm dia 'B' Class G.I. waste water pipe and 32mm dia C.P. waste coupling. with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works] |
| 208 | Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed by the departmental officers |
| 209 | Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed by the departmental officers. |
| 210 | Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed by the departmental officers. |
| 211 | Fire fighting Arrangements: Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling wht rotating wheel to open and close the valve including MS flange of table 'E' bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 212 | Supply, installation of Fire fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20 mm dia ball valve and open and close spray nozzie, warm clip, etc., as per the standard pattern of nay reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, necessary scaffolding and re-doiing the dismantled portions to its original condition wherever found necessary., etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 213 | Supply, and fixing in position of Fire fighting Application Hose of 63mm dia of 15 metres length binded by coppper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 214 | Supply, and fixing in position of Fire fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzie of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 215 | Supply of Fire fighting Application MS Hose Box to keep two number of hoses and 1 no. of branch pipe with nozzie having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 216 | Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI coller for each sprinkler bulb, mounted in MS pipe ling using suitable size MS threaded coupling, thread, shellac etc., as per standard mehtods and including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original -condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. |
| 217 | Supply, erection, testing and commissioning of MS ‘C’ Class heavy duty pipe as per IS 1239,to withstand a developing pressure of 10kg/sq.cm including necessary fittings like MS flange of table ‘E ‘ Elbows, reducers, gaskets, both, nuts with washers & Joints as per standard method of arc welding .Including one coat metal primer and two P.O RED painting including conveyance ,all incidental charges ,necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make; JINDAL/EQUIVALENT. |
| 218 | 200 mm dia |
| 219 | 150 mm dia |
| 220 | 100 mm dia |
| 221 | 80 mm dia |
| 222 | 40mm dia |
| 223 | 50 mm dia |
| 224 | 25 mm dia |
| 225 | Wrapping and coating anti-corrosive treatment for underground 150mm dia MS pipe having one coat of anti-corrosive metal primer ,one layer of Asphalt Tar tape wound over the M.S Pipe as per standard methods as per standard specification as directed by the departmental officers |
| 226 | Supply, erection, testing and commissioning of following sizes heavy duty foot valve including all accessories such as MS flange of table ‘E’ gaskets,bolts&nuts,etc.,installed at end of 150/200 mm dia suction pipeline at sump including conveyance ,all incidental charges ,necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make :NORMEX/KARTAR |
| 227 | 200 mm dia |
| 228 | 150 mm dia |
| 229 | Supply ,erection, testing and commissioning of Cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’ gaskets , bolts & nuts including conveyance all incidental charges ,necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make:NORMEX/KARTAR |
| 230 | 150 mm dia |
| 231 | 100 mm dia |
| 232 | Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead, tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312. including conveyance, all incidental charges, necessary scaffolding and re-doing dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. |
| 233 | 150 mm dia |
| 234 | 100 mm dia |
| 235 | Supply, erection, testing and commissioning of Butterfly valve of size 50mm dia including necessary MS flange of table ‘E’ gaskets, blots & nuts, etc. installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make:LEADER/EQUIVALENT.150 dia (Pump room, All Floor Sprinkler branch – Ground floor to 5th Floor) |
| 236 | Supply, erection, testing and commissioning of Butterfly valve of size 150mm dia including necessary MS flange of table ‘E’ gaskets, blots & nuts, etc. installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the departmental officers. Make:LEADER/EQUIVALENT.150 dia (Pump room, All Floor Sprinkler branch – Ground floor to 5th Floor) |
| 237 | Supply, erection, testing and commissioning of Sprinkler Deluge valve set of size 150mm dia including necessary MS flange of table ‘E’ gaskets, bolts & nuts, etc., installed at pump house delivery line for the purpose of Delivery line so that to control one way including conveying, fixing and incidental charges etc complete as per standard specification and as directed by the departmental officers, Make: HD |
| 238 | Supply, erection, testing and commissioning of Sprinkler Flow Switch of size 150mm dia including necessary MS flange of table ‘E’ gaskets, bolts & nuts, etc., installed at sprinkler delivery line for the purpose of flow line so that to control one way including conveying, fixing and incidental charges etc complete as per standard specification and as directed by the departmental officers, Make: Honeywell |
| 239 | Supply and providing 1000 Litres capacity priming tank made up of PVC Make: SINTEX/EQUIVALENT |
| 240 | Priming tank mounted with the supporting arrangement fabricated using MS angle for the height of 3.00 mtrs from the floor level, inlet, outlet, and drain arrangements inside the fire fighting pump room as directed by the department officers |
| 241 | Supply and laying of following sizes of armoured Aluminium/Copper cables for electrical motor. control Panel, Pressure switch, jockey motor etc. all incidental charges necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc.Make.POLYCAB/PARACON/FINLOEX/EQUIVALENT |
| 242 | 3 core 185 sq.mm armoured aluminium cable |
| 243 | 3 core 10 sqmm armoured copper cable |
| 244 | 10 core 2.5sqmm copper cable |
| 245 | 2 core 2.5 sqmm armoured copper cable |
| 246 | Earthing arrangements with GI earth plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work. Refilling the sides of foundation with excavated earth as per the standard specification and as directed by the department officers. |
| 247 | Supply, erection, testing and commissioning of pressure Gauge with 0 to 14 kg range of reputed make with necessary value, milling thread Ms coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance. All incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc. complete as per standard specification and as directed by the departmental officers. Make: H-GURU/ISIMARK/EQUIVALENT. |
| 248 | Supply, erection, testing and commissioning of suitable Pressure switch of reputed make line indfoss or Donfoss including necessary values, couplings etc. connected with electrical main control panel and setup at proper differential so as to auto start& auto stop the electrical motor. Jokey motor including conveyance. all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary metering protections & indications complete as per standard specification and as directed by the departmental officers. Make: DONFOSS/INFOSS/ISIMARK/EQUIVALENT. |
| 249 | Supplying, installation, testing and commissioning of Fire Fighting Electrical Control Panel of cubical construction, floor mounted type fabricated using CRCA sheet, compartmentalised with hinged lockable door dust and vermin proof, cable alley, inter connection having switch gears and accessories mounting and internal wiring, earth terminals, numberings, necessary metering protections and indications complete in all respect suitable for operation on 415 volt, 3 phase, 50 Hz AC supply with enclosure protection class IP 54 and mounted with the followings. A.Coomon Panel in Fire Pump House (i) Incomer a. 1 No. 600A TP & N SDFU with HRC fusesb. 1 set of 600 A, 4 bar aluminium bus bar, 415V, 50 |Hz AC supply c. 1 No. (0-500A) digital ammeter with selector switch & CTs d. 1 No. (0-500V) digital voltmeter with selector switch and control fuses e. 3 Nos. phase indication lamp LED type with toggle switches with control fuses. |
| 250 | (ii) Outgoing a. Main Fire Pump400 A TPN SDFU with HRC fuses with suitable HP fully automatic starter / delta starter with over load protection , digital ammeter with built- in selector switch and suitable CTs, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operaton, selector switch for auto/ manual / OFF operation - 1 No......b. Jockey Pump 125 A TPN SDFU with HRC fuses with suitable HP fully automatic starter/ delta starter with over load protection, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic opertion, selector switch for auto / manual operation - 1 No. c. Diesel Engine Control comprising of :1. Auto / manual selector switch and 3 attempt starting device, timers and relays as required, push buttons, start / stop in manual mode.2. Indication lamp for high/ low lubircant oil pressure, high water termperature and engine ON indication. 3. Battery charger suitable for 12V/ 24 V DC with boost and tickle selector switch, 0-15V/0-30V DC volt meter, 0-20A DC ammeter4. All standard relays and accessories for automatic operation of diesel engine.5. The above combined panel mounted over MS channel fabricated frame with cement concrete platform, all other connection works carried out as per standard methods and including conveying, fixing and incidental charges, etc., complete as per standard specifiction and as directed by the Departmental Officers. |
| 251 | Supplying, erection, testing and commissioning of Fire Fighting Electrical Control Panel of 10HP, 415V, 50Hz, rating Wall Mounted Type fabricated using CRCA sheet, hinged lockable door, dust and vermin proof with following provisions, a. 30 Amps, 4 Pole MCB-Incomer, 6 Amps, 2 Pole MCB for Control Circuit - 1setb. R, Y, B Phase Indication Lamp, Voltmeter(0-500V) Ammeter (0-50A), Voltmeter Selector Switch-1setc. 32 Amps Power Contractor with 230V Coil, 14-23 Amps Over Load Relay - 1set.d. Single Phase Preventer - 1 No.e. Indication Lamp for Motor On/Off Push Button- 1setf. Auto/ Manual Selector Switch, On/ Off Button-1setg. Add on Block, Terminal Block, Power Wiring, Control Wiring, Connectors, Cable Lugs, Slotted Cable Cover.The above panel mounted on wall using anchor fastners, bolts, plugs, incoming and outgoing cable connection and all works carried out as per standard specifications and as directed by the Departmental Officers. |
| 252 | Supply, erection, testing and commissioning of Diesel Engine Pump Main Control Panel & Jockey Pump including necessary auto cut-in, cut-off and manual operations, battery charger switch arrangements, voltmeter, ammeter and running indication siren provision, wall mounting type etc., as per the standard method and as directed by the Departmental Officers. |
| 253 | Supply, erection, testing and commissioning of Fire fighting Application Horizontal Centrifugal Type Pump Rated for 2280 LPM at 70 metres head with Electrical Motor of 60 HP of 415 volt 3 phase connection complete with base plate and accessories. The rate inclusive of necessary vibration, bad mounting etc., as per standard method as directed by the Departmental Officers. |
| 254 | Supplyu, installation testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings complete in all respects as required. A. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 4550 LPM against a total head of 110 metres, so as to ensure a minimum pressure of 3.5kg. per sq.cm at the fartherst top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring etc., on non - corrosive metal either like bronze, brass or gun metal and shaft of stainless steel.b. 100 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete.c.Auto starting mechanism, 12 volts / 24 volts eletric starting equipment like self motor, dynamo, solenoid switches etc.d. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc..............e.Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m ouside pump house duly insulated with 50mm thick glass wool wth 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition. |
| 255 | f. Dash board consisting the instruments like Temperature Gauge, Galvano Type DC Ammeter, Lubricant Oil Pressure Gauge, Ignition Switch, Emergency stop and all other protection equipment as per specification, stop soleneid for auto stop in the event of fault wtih audio indications, painted with Post Office Red Colour etc.,as required. g. 12V /24V storage battery, maintenance free tape, 180 AH rating, MS fabricated common base plate, coupling guard, foundation bolts etc., as required. h. Postioning the diesel engine driven fire pump over cement concrete foundation using suitable size anti-vibration mounting arrangement.All works including conveying , fixing and incidental charges etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIRLOSKAR ? EQUIVALENT. |
| 256 | Supplym erection, testing and commissioning of 180 LPM, 70 metres, Head Pressurization Pump with 10 HP electrical motor of Kirloskar make with suitable base frame incluidng necessary vibration bad mounting etc.,m including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. |
| 257 | Supply, erection, testing and commissioning of fire fighting application Monoblock Motor Pumpset of 900 LPM at 40 metres head to develop 3.5kg / sq.cm at the heighest and farthest hydrant point to make 30m water jet at the time of fire fighting emergency circumstances, coupled with 15KW / 20HP rated three phase 414 volts, 50 HZ, 2880 rpm electrical motor the pump with cast iron body, bronze impeller, rope gland packaging, suction size of 100mm dia, delivery size of 80 mm dia, including the cost of foundation concrete, anti-vibration mounting, rain safety hood and etc., complete as directed by the Departmental Officers. (Make: Kirloskar KDS 2050 + or Equivalent) |
| 258 | Supply , erection testing and commissioning of Fire Fighting 4 Way Fire Brigade inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. |
| 259 | Supply, erection, testing and commissioning of Air Release Valve of 20mm dia so as to release airlock in 100mm dia MS pipe at top most wet riser, ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. |
| 260 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS 15683 with pressure gauge, discharge hose & control nozzie, wall mounting bracket, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. |
| 261 | Supply and fixing of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms., etc complete as per standard specification and as directed by the Departmental Officers. |
| 262 | Supply and fixing Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS:15683., complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., ncluding conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition whererver found necessary etc complete as per standard specification and as directed by the Departmental Officers. |
| 263 | Supply, Installation, testing and commissioning of Micro Processor based Conventional 12 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230/24 volt SMPS unit, 2 Nos. of 12 volt, 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 264 | Supply, Installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS junction box / false ceiling using fixing accessories llike screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers, (Make: Apollo / Equivalent) |
| 265 | Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers, (Make: Ravel / Equivalent) |
| 266 | Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers, (Make: Ravel / Equivalent) |
| 267 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. |
| 268 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point/fan point (for electronic regulator) (5points/Coil) Higher End) [Data-1] |
| 269 | Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End. [Data-2] |
| 270 | Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End. [Data-3] |
| 271 | Supply and fixing of 1 no.6/16A two module socket, 1 no. 16A one module switch on suitable module surface mounting Box (GI) with module cover plate (plastic) on wall with connections. Higher End [SD-402] |
| 272 | Supply and fixing of 3 nos.6A two module 5 pin socket 3 nos. 6A one module switch on suitable module surface mounting Box ( GI ) with module cover plate (plastic) on wall with connections. Higher End [SD-390] |
| 273 | Supply and fixing of 4nos.6A two module 5 pin socket , 4 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End. [SD 396] |
| 274 | Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection. (For AC Plug). [SD-143] |
| 275 | Supply and fixing of bulk head fitting with guard suitable with 9W LED bulb. [Data-4] |
| 276 | Supply and fixing of WT bulk head fitting with guard suitable with 9W LED bulb. [SD 84] |
| 277 | Supply and fixing of 4 Feet LED 18W Fitting with LED 18W tube (Higher End) complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube.[SD-445] |
| 278 | Supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. [SD-448] |
| 279 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting. [SD-457] |
| 280 | Supply and fixing of 1200mm (48\\") sweep BLDC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod on the existing fan clamp. [DATA-5] |
| 281 | Supply and fixing of 200mm UPVC exhaust fan complete without provision of hole in the wall. [Data-6] |
| 282 | Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. (SD-115) |
| 283 | Supply and fixing of louvers shutters arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan. (SD-120) |
| 284 | Supply, erection, testing and commissioning of 2.0TR (6000 K. cal/ hr) ABS plastic split type Air conditioner conforming to IS: 1391 (Part-2) 1992 with Amdt No.1 to 2 fitted with Rotary compressor operating on refrigerant R-22/ non- CFC suitable for wall mounting for operation on 230V, 50 HZ single phase AC supply with Five star rating as per BEE specification and capable of performing the functions of A) Cooling B) Dehumidifying C) Air circulation D) Filtering The installation works for the above split type A.C units includes the following.1. Mounting / Fitting indoor and outdoor units at their respective locations.2. Laying refrigerant pipeline of required length connecting not exceeding 6 meters distance and both units after drilling hole / holes in the wall if required. Thickness of the copper tubing shall not be less than 0.7mm. |
| 285 | 3. Insulating the suction pipe with expanded polythene foam 5mm tubing.4) Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed with in the indoor unit.5) Leakage testing the entire system unit.6) Charging refrigerant gas in the unit.7) Suitable electric wiring to be provided with 2.5 sq.mm PVC insulated copper wire between indoor and outdoor units upto 6 meters length and upto switch within 3 meters of location of indoor unit.(Make- Bluestar/Voltas/Ogeneral make only) [M-1985] |
| 286 | Supply and fixing of 5 KVA electronic automatic voltage stabilizer V. Guard make model VGS 400 with input range of 170-270V and out put range 200-240 V with high and low voltage cut off and 3 minutes time delay relay with demonstration.[M-1989] |
| 287 | Supply and fixing of wall clamp support for mounting outdoor unit of split type AC unit complete. [M-1991] |
| 288 | Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit). [M-1990] |
| 289 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End. [SD-523] [For Floor Lighting DB] |
| 290 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End [SD-537] [For Floor Power DB] |
| 291 | Supply and fixing of 8 way SPNMCB distribution board made out of sheet steel/aluminum rail complete with bus bar arrangements incorporating the following controls with double door arrangements [IP 42 Metal door of Legrand] in flush with wall & making good of the concealed portion with earth connection.(1) 32A DPMCB Isolator as Incoming: 1No, (2) 10A DPMCB as outgoing: 2Nos, (3) 6A to 32 A SPMCB as outgoing: 2 Nos. (MCBDB, Isolator, MCB should be Legrand)] (LIFT Head Room) [DATA-7] |
| 292 | Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4P MCB Isolator as incoming and 4 nos. 32A 3P MCB as outgoing in flush with wall with earth connection only. Higher End. [Data -8] [For Duct AC] |
| 293 | Supply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100A 4P MCCB Isolator as incoming and 4 nos. 63A 3P MCB, 6 Nos 6A to 32A SP MCB as outgoing with cable entry box in flush with wall with earth connection only. Higher End. [Data -9] [For Lighting and Power incoming DB] |
| 294 | Supply and fixing of 4 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board with double door (metal) with 1 no. 160A 4P MCCB Isolator as incoming and 4 nos. 63A 3P MCB as outgoing with cable entry box in flush with wall with earth connection only. Higher End. [Data -10] [For 80KVA Online UPS] |
| 295 | Supply and fixing of 7 segment 4 way 63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 4 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. [SD-636].63A 4P MCB - 1 no.63A 4P 30MA RCCB/ELCB - 1 no.63A DP MCB Isolator -3 nos.6A to 32A SP MCB - 12 nos. |
| 296 | Supply and run of 2 of 1.5sqmm (22 /0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour. [DATA-11] |
| 297 | Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5Sqmm copper wire and making good of the concealed portion with suitable colour. Data-12 [ For Computer Plug] |
| 298 | Supply and run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4sqmm copper wire and making good of the concealed portion with suitable colour. Data-13 [For 15A plug Ac Plug, Power plug, Lighting DB] |
| 299 | Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. Data-14 [For Power DB] |
| 300 | Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. Data-15[For Duct AC] |
| 301 | Supply and run of 4 of 16 sq. mm (101/ 0.45) PVC insulated S.C unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 Sqmm copper wire and making good of the concealed portion with suitable colour. [DATA-16] [For 7 Segment DB, Lift] |
| 302 | Supply and run of 4 of 25 sq. mm (101/ 0.45) PVC insulated S.C unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 25 Sqmm copper wire and making good of the concealed portion with suitable colour. [DATA-17] [For VTPN DB] |
| 303 | Supply and fixing of 32A FP ELCB with sheet steel enclosure in flush with wall with earth connection. [Data-18][For Duct AC] |
| 304 | Supply, Installation, Testing, Commissioning and Handing over of 5.5 TR Capacity ceiling suspended ductable Air conditioner high tech, low height, low noise level indoor unit with fin and tube type cooling coil, Detachable type drier provided in refrigerant circuit to reduce moisture content multi-stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil with required valves, directly coupled blower to reduce troubles and wear & tear compared to drive blower. Thermostatic expansion valve lift and pull type aluminium framed durable, washable air filter. Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditoners of 45 F suction temperature. Auto reset type HP/LP safety cut to |
| 305 | improve relaibility of compressor. B) 5.5 TR capacity ceiling suspended ductable air conditioner high tech outdoor unit with power saving high efficiency sturdy and rugged 1 No. of scroll compressor each with in-built internal thermal protector, internal pressure relief valve, Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shall be made of super slit high efficient aluminium fins mechanically bonded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners, imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration. The fans are direct driven 3 phase motor with protection. Condensing temperature 130deg.F for the system operations. [M1993] |
| 306 | Supply and filling of non-CFC Refrigerant Gas. (SR XIV part N 5 M-2046 ) |
| 307 | Supply & fixing of hard drawn copper Refrigerant piping of suction line of Size 7/8” inches with necessary fitting and clamp etc…(SR XIV part N 3 M -2003 ) |
| 308 | Supply & fixing of hard drawn copper Refrigerant piping of liquid line of size 5/8” inches with necessary fitting and clamp etc…(SR XIV part N -1- M-1990) |
| 309 | Supply and fixing of 50mm thick anti vibrating rubber pads (SR XIV part N -3- M-2005) |
| 310 | Supply, Fabrication and Installation of 22 G Sheet GI Ducting for both suction and Return arrangement insulate with for Operation Theatres with inter linking arrangements with necessary angle supports, anchor fasteners and threaded rods etc... as required. (SR XIV part N -3- M-2007 ) |
| 311 | Supply, Fabrication and Installation of 24 G Sheet GI Ducting for both suction and Return arrangement insulate with for Operation Theatres with inter linking arrangements with necessary angle supports, anchor fasteners and threaded rods etc... as required. (SR XIV part N -3- M-2006 ) |
| 312 | Supply and Providing Thermal Insulation of 9mm thick vidoflex with aluminium foil.(SR XIV part N -3- M-2016) |
| 313 | Supply and fixing of powder coated Extruded aluminium powder coated supply and return air grilles/diffuser with volume control damper .(SR XIV part N -3- M-2009 ) |
| 314 | Supply, fabrication and fixing of duct mouth dampers.(SR XIV part N -3- M-2014 ) |
| 315 | Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable Clamp as required.(SR XIV part N -3- M-2010 ) |
| 316 | Supply, fabrication and fixing of suitable MS angle support frame for mounting the out door Units.(SR XIV part N -3- M-2012 ) |
| 317 | Supply and providing of pipeline nitrile rubber insulation for Refrigerant and drain pipeline. (SR XIV part N -3- M-2013 ) |
| 318 | Supply and providing accoustic for initial portion of ducting with 12mm thick fibre glassrigid board covered with tissue paper and Aluminium perforted sheet (SR XIV Part N 3 M-2015) |
| 319 | Supply and fixing of microvee filter 600x600mm size fine microvee mesh filter with efficiency of 5 micron level for return air. [MR] |
| 320 | Supply, fabrication and fixing of Fresh air Louver made of extruded aluminium with bird screen provided with intake louvers. [MR] |
| 321 | Design, Engineering, Supply, Fabrication, Erection, Testing, Commissioning and Handing over of 1No. 16 persons 1088kgs. Capacity Passenger Lift (Gearless) With Machine Room as per the following specifications.[M-2368]1. Location : Passenger Lift 2. No. of Lift : One No3. Type of Lift : Passenger Lift with machine room Less - Gearless model4. Capacity of Lift : 16 Persons / 1088kgs5. Speed : 2.5 mtr / sec6. Type of Drive : V3F Drive with enhanced ride comfort and near Zero Level Functions.7. No. of Floors : Slit floor + 3 Floors |
| 322 | 8. Total Travel : 14 Mtr / Pit 2500mm / Head room 5600mm9. Leveling accuracy : High level accuracy with smooth and jerk free stopping.10 Construction of Lift well : RCC with brick masonary/ Brick well. 11.Car: 1.5mm hairine finish High Quality S.S. Car and Hand rail, PVC flooring and Perspex False Ceiling.12 Position of Machinery: Directly above the Lift well – Gearless with machine room.13 No. of Landings: 4 Nos in the front side. 14 No. of Car Entrance : One in the front side.15 Car Entrance : Power operated V3F Drive, side opening Sliding Stainless Steel (1.5mm) Hairline finish door. |
| 323 | 16 Landing Entrance door : side opening Sliding Stainless Steel (1.5mm) hairline finish door with provision for Emergency Exit key at All landings. 17 Lift well : 2550mm (Wide) x 2350mm (Depth) as per IS 14655(Part 1) 2000. 18 Lift Pit : 2500mm (available) Depth.19 Car Size : 1700 x 1800 (mm Wide x mm Depth x mm Height as per IS 14665 (Part I) 2000 20 Car Clear Opening of Gates / Doors / Lintel : 1200mm Wide x 2000mm Height and Lintel : 2300mm as per IS 14665 (Part I) 2000 20 Power Supply : 400/415V 3phase 50Hz AC Power Supply.21 Type of Control System : Micro Processor based Simplex Selective Collective control with / without attendant.22 Car fittings : LED lights & Regular (Square) cabin fan.23 Lift Well : Available24 Indication : UP / DOWN Digital direction and position indicator for all Landings and inside the car.25 Emergency provisions : Battery operated Alarm bell & Light to be Provided with Automatic charging device.26 Fire Man’s switch : In the Ground Floor27 Minor Builder works : included28 Scaffoldings : included |
| 324 | 29 Sill angles and Facio Plates : included30 Steel for Lift Machinery : included31 Servicing and maintenance : Free Comprehensive Maintenance for one Year Guarantee period.32 Automatic Rescue Device : Provision to facilitate the landing to the nearest floor at the time of power failure. The ARD consists of suitable Battery system with charger, Inverter, under voltage protection system etc. complete with all accessories. 33 Provision for Intercom : To be provided in the Ground Floor & Machine Room with Phone (Press & Speak).34 Lift License : Preparation of Drawings, payment of inspection charges to CEIG and insurance policy and Obtaining CEIG approval for the Lift as per Lift act should be done by the Lift contractor.35 Floor Position : Included with LED display and floor annunciator.36 Special Features:a. Infra red door sensor with full height screenb. Full width half height rear panel mirrorc. S.S. hair finish hand rail in card. Stainless steel signal featurese. Vandal proof SS button with SS cover |
| 325 | f. S.S. hairline finish door frames for landing doorsg. V3F door operatorh. Call register signali. Stainless steel facio plates for car operating panel and landing fixturesj. Steel ladder for Lift machine room in lift pit.k. On / Off switch for fan and lightl. Over-load warning indicator with audio Announcerm. Voltage stabilizer for control circuit.35 Over Speed Governor, Phase failure and Phase reversal Relay, alarm bell, T guide brackets for car and counterweight, Rubber padding under the winding unit, Motor of adequate capacity, Electromagnetic brake with compression springs, Car safety gears, Buffers, Electro mechanical locks, Emergency key, side supporting angles, Motor over - load protection devices, Final limit switch main, suspension ropes, Counter weights, Lifting joist for mounting the Machineries. |
| 326 | 36. Guarantee : Guarantee at least for one year for the materials and workmanship of equipments should be offered by the Lift contractor.37. Site testing in accordance with IS 14665 should be carried out at the time of Handing over to the User department.38. Supply, operation and maintenance manual and necessary tools for operation and a set of spare parts required for one year to be provided.(Johnson/Kone/OTIS) |
| 327 | Supply and Fixing of 16A Two-way switch in suitable MS box in flush with wall with earth connection [Data-19] |
| 328 | Supply and run of 3 of 2.5 sqmm (36/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable heavy gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 2.5Sqmm Copper wire with painting of suitable colour. (For Lift Well Light Control) (SD 333) |
| 329 | Supply and handing over of 1No.58.5 KVA Diesel Generator set with AMF Panel of 0.80 PF Three phase 415 volts, 50Hz, 1500 RPM as detailed below :ENGINE : Water cooled diesel engine suitable for generator application with a shaft output of 200 BHP at 1500 rpm under NTP conditions as per BSS [CPCB-IV-BISIV model ] 5514 /IS 10000. The engine shall comprise the following standard scope of supply. (Kirloskar / Ashok Leyland / Equivalent) 1. Dry type air cleaner.2. Expansion bellow.3. Radiator, Radiator fan and mounting.4. Air to air charge cooler.5. Exhaust gas turbocharger.6.Lube oil cooler and tube oil filter.7. Fuel filter (Pre and micro).8. In-line mono-block fuel injection pump with Governor and fuel feed pump.9. ELectronic Governor.10. 12 Battery charging alternator.11. 12V electric starter motor.12. Enginer test certificate.13.Residential mufler.14. FLy wheel with starter ring. |
| 330 | ENGINER INSTRUMENTAL PANEL MOUNTED:Engine control panel consisting go ON / OFF / START key, Lube oil pressure gauge, oil temperature gauge, high water temperature gauge and electronic hour meter and RPM indicator.SAFETY SYSTEM OF ENGINE: The Engine shall trip for the following conditions with visual alarm device.1. Low lubricating oil pressure.2. High water temperature.3. Vee - belt failure and over speed.The following visual indicator should also be provided low battery indication.The engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load.II. ALTERNATOR:Alternator capacity of 58.5KVA / 46.8KW, 3 phase, 415 volts, 0.8 PF, 4 wire self excited & self regulated design to run at 1500 rpm under NTP condition confirming to BS 5000/ IS 13364 (Part II) 1992 to be coupeld directly to the diesel engine and test certificate. Make : ( Kirloskar Green / Crompton ) |
| 331 | III. AUTO MAIN FAILURE PANEL(AMF): The AMF/ATS control panel ( Cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connecting incoming and outgoing leads have been made on the control panel.1. 1 No. AC ammeter.2. 3 Nos. CUrrent transformers with suitable radio.3. 1 No Ammeter selector switch.4. 1 No. AC Voltmeter.5. 1 No. Voltmeter selector switch6. 1 No. Frequency meter. 7. 1 No. KWh meter8. 1 No. Power factor meter. |
| 332 | 9. Battery charging set comprising of the following for charging the battery from mains.A. Transformer / Rectifierb. DC ammeterc. Charging rate selector switchd. DC voltmetere. Circuit breakerf. Voltage regulatorg. ON / OFF switch.Note : This will be in addition to the battery charging alternator fitted to the Engine.11. 1set Air break contactor with auxiliary neutral contactor for main supply.12. 1set Low voltage HRC fuse for the short circuit protection of the main supply.13) 1set Alternator contactor with auxiliary neutral contactor.14) 1set Three pole bimetal release for over load protection of the alternator.15) 1set Low voltage HRC fuse for the short circuit protection of the alternator.16) 1set DC control relays incorporating engine start stop and failure to start/lockout. |
| 333 | 17) 1set Selector switch auto/manual.18) 1No. Push button \\"Start\\".19) 1No. Push button \\"Stop\\".20) 1No. Push button \\"Reset\\".21) 1No. Signal lamp for indicating load on mains.22) 1No. Signal lamp for indicating load on set.23) 1No. Signal lamp for indicating set fails to start.24) 1No signal lamp for indicating ‘Set running’25) 1No signal lamp for indicating ‘Battery charger ON’26) 1set pilot lamps of 3Nos27) MCCB of 500A capacity with magnetic thermal over load release, instant start circuit trip and under voltage release switch.28) Rectangular copper bus bars (1No for each phase, neutral and earthing terminal) of adequate capacity duly colour coded with head shrinkable PVC sleeves.29) 1No mains voltage monitor30) Hooter/Audio alarm for indication set fails to start and for DG O/L31) 1set timers32) Audio and visual indication arrangements for,a) Low lubricating oil pressureb) High water temperaturec) Over speed33) 1No Earth fault relay34) Isolator to Isolate the neutral |
| 334 | Note:1. The control panel should be complete with necessary fuses, cables lable other accessories and with neutral isolation arrangements.2. The engine should trip for the following conditions.a) Low lubricating oil pressureb. High water temperaturec. OverspeedSURFACE TREATMENT PAINTING: The enclosure surface shall be suitable treated for degreasing, derusting and posphating. The canopies are passed through seven tank treatment throughly for degreasing, derusting and posphating. The canopies are passed through seven tank treatment throughly.ADDITIONAL FEATURES OF CANOPIES:Canopy fabricated on CNC machines with dimensional accuracy of 0.1mm so as to increase its durability. Special designed supporting ribs / structure are used in canopies so as it give sturdiness and to reduce the vibrations of the DG sets if any. |
| 335 | WORLD CLASS COOLING PACKAGE :Canopies shall have cooling package for which it can also perform at 45 deg C ambient temperature.No grouting required on the ground, only a level surface capable of with standing the DG weight.Lifting hooks are provided for the acoustic enclosure which should be unloaded independent of the DG set. The genset base frame should be also provided with hooks for unloading.FUEL TANK: Approximately 388 Litres removable fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance set.BATTERY: 1 No 12 Volts 150AH Battery. [M-2331] |
| 336 | Supply and demostration of the following safety accessories like 1 meter x 1 meter x 1/2 inch 11KV rubber mat - 2Nos. [M-1976] |
| 337 | Erection, testing, commissioning and handing over of Gen set: Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation for erection of 58.5KVA Diesel Generator set over the existing foundation and erection of generator set with proper alignment over the exisiting fountation to suit 58.5KVA Genset foundation. |
| 338 | Supply and fixing of 250 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only. [SD 648] |
| 339 | Supply, Fabrication, Erection, Testing and commissioning of indoor dust and vermin proof four compartment CT Metering panel made up of 16SWG CRCA sheet of size 48\\" x 48\\" x 18\\" with necessary stiffner and provided with following arrangements.1. Front open door for each compartment provided with sealed locking arrangement. 2. 6mm thick hylam sheet in metering compartment for fixing 3phase 415V 4wire 50Hz Digital Energy meter provided by TANGEDCO. 3. 3Nos 1.5\\" x 1/4\\" and 1\\" x 1/4\\" Copper bus bar on suitable bus support with 3Nos 200/5A CTs in bus bar compartment.4. 3Nos 200A fuse unit & 1no 150A neutral link on 6mm thick hylam sheet in fuse comparment. 5. Fixing of control fuses and wiring with flexible PVC copper wire and LED Indicator arrangements. |
| 340 | 6. 2Nos copper earth bus of 1\\" x 1/8\\" in the rear side.7. Suitable MS base channel for mounting.8. Viewing glass in the door for meter compartment.9. Provision of cable entry and outgoing compartment.10. Painting the panel with 2 coats of epoxy paint over one coat of red oxide. [DATA-20] |
| 341 | Supply, Erection, Testing & Commissioning of 250A capacity Dust & Vermin proof cubicle panel made out of 16SWG CRCA sheet steel enclosure with supply & fixing of the following interior mounting fuse switches with HRC fuses with a central bus bar chamber & two numbers of Horizontal cable chamber at top and bottom.250A FP SDF Double Break switch withHRC fuse units - 2Nos as incoming.Outgoings: 1. 200A TPN SDF Double Break switch with HRC Fuse units - 1 No.2. 125A TPN SDF Double Break switch with HRC Fuse units - 4 Nos. 3. 63A TPN SDF Double Break switch with HRC Fuse units -5 Nos.The bus bar chamber consist of 4nos. of 30mmx6mm Copper flat for three phases and neutral and also for interconnection for 250A and 200A switch. |
| 342 | The interconnection with the bus bars to the 125A SDF DB Switches with 30mmx3mm Copper flat and that for 63A SDF DB swiches with 30mmx3mm Copper flat Conductor. And Double earth connection to all the switches should be done using No.8 SWG Copper conductor.The buses should be mounted on the SMC bus insulator at proper & sufficient spacing between the buses as per IE rules.The bus bar chamber should be segregated from the adjacent chamber by providing hylem sheet of 6mm thick as partition 2 runs of 25 x 3mm copper flat should be provided all around the panel for earth connection. Phase & Neutral copper buses should be provided with heat shrinkable sleeves using RYB & Black colours. Indicator lamps should be provided with toggle switches & Bakelite fuse unit. |
| 343 | The capacity of fuse switches, size and route location of the UG cable shall be superscribed on all the incoming and outgoing switches.The Panel should be mounted on angle iron frame work of size 1½\\"x1½\\"x¼\\" MS channel provided all around the sides of the panel. The whole arrangements should be erected on a suitable masonary pedastal. (All Switches should be with ISI mark and of Higher End make only) [Data-21] |
| 344 | Supply and Laying of 3 1/2 x 150 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. [SD 674] |
| 345 | Supply and clamping of 3 ½ x 150 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD - 211) |
| 346 | Supply and fixing of brass cable gland for 3 ½ x 150 sq.mm PVC armoured LTUG cable, with earth connection.(SD-170) |
| 347 | Supply and providing cable end termination of 3 ½ x 150 sq mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete (SD-229) |
| 348 | supply and fixing of 65 mm dia. (2 -1/2\\") GI pipe (class B) of 8 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 120W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour. [Data-22] |
| 349 | Supply and Laying of 4 x 10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD - 666) |
| 350 | Supply and clamping of 4 x 10 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps. (SD - 203) |
| 351 | Supply and erection of 40KVAR Automatic power factor control device. [M-2460] |
| 352 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection [SD-372] |
| 353 | Earthing as per PWD standard with an earth electrode of 2 metre Class'B' GI pipe of dia not less than 32mm complete with necessary masonry work. [SD-222] |
| 354 | Supply and installation of 4 Megapixel resolution Infrared Network Bullet/ Dome Camera with IR Range upto 30 meters,120dB WDR,Video Compression in H.264/MJPEG format,Day & Night auto switch IR cut filter,IP67 Protection level with mounting Bracket SR M 2806 |
| 355 | Supply, fixing and termination of D-Link Make 24 Port PoE switch in existing Rack with accessories. DATA-1 |
| 356 | Supply and installation of 32 Channel 4K Network Video Recorder with 8 numbers of SATA ports.s (including wireless mouse, 1.5 meter HDMI Cable). DATA-2 |
| 357 | Supply and installation of 65 NCH 24x7 SIGNAGE DISPLAY with all relavent accessories SR M 2764 |
| 358 | Supply and installation of 55 NCH 24x7 SIGNAGE DISPLAY with all relavent accessories SR M 2763 |
| 359 | Supply and fixing of 8TB Hard Disk for NVR with all relevant accessories. SR M 2223 |
| 360 | Supply and erection of 2 kVA 1 Phase online UPS (Single Phase In & Single Phase Out) System with Battery and 2 hours back-up.SR M 2101 |
| 361 | Supply,fixing and termination of Cat 6 UTP Patch cord of 2 metre.SR M 2233 |
| 362 | Supply,fixing and termination of Cat 6 UTP Patch cord of 1 metre.SR M 2232 |
| 363 | Supply and installation of 24 port Fully Managed 10 / 100 / 1000 Layer-2 with 1G Uplink - Higher End with 24 port jack panel and necessary accessories. DATA-3 |
| 364 | Supply and installation 9U three tier MS Rack for housing LAN Switches with top and Bottom Cable Entry provision along with necessary power distribution unit,cable manager,fan and Lockable Toughened Glass Door. DATA-4 |
| 365 | Supply and Installation of Basic IP Phone with all relavent accessories. DATA-5 |
| 366 | Supply and fixing of 6 Trunk line 10 SIP Trunk ,96 IP Port 64 analog Extension ,Expandable Up to 96 anlog Extension + 112 IP Port . with all relavent accessories. DATA-6 |
| 367 | Supply fixing and termination of I/O Box for LAN with all relevant accessories including I/O Socket,PVC Module,Face Plate and Patch Cord,DATA-7 |
| 368 | Supply and run of Unarmoured LAN/ Cat6 cable in PVC rigid pipe concealed in wall and Ceiling and making good of portion with suitable colour . DATA-8 |
| 369 | Supply and run of 2 of 1.5sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 1.5sq.mm copper wire with painting of suitable colour SD 54 |
| 370 | Supply and Installation of Delegate unit which consists of amplifier with long length goose neck microphone with ON/OFF switch indicator and built in speaker. Make and Model: Bosch CCS 700/ /Bose/Eq DATA-9 |
| 371 | Supply and Installation of Chairman unit which consists of amplifier with long length goose neck microphone with ON/OFF switch indicator and built in speaker. Make and Model: Bosch CCS 700/ Bose/Eq DATA-10 |
| 372 | Supply and Installation of 18 INCH GOOSENECK MICROPHONE WITH BASE with all relavent accessories. Data-11 |
| 373 | Supply and Installation of Cordless Mic UHF with all relavent accessories Make:Shure/ sneheisor Equivalent Data-12 |
| 374 | Supply and installation of 8 Pin Conference Mic Socket with Modular Box and Front Plate with all relavent accessories. . DATA-13 |
| 375 | Supply and Installation of Conference system Controller consists of additional Mic/Aux provision with ON/OFF switch indicators. Make and Model: Bosch CCS 700 DATA-14 |
| 376 | Supply and Installation of 12 Channel Analog Mixer with USB & Phantom relavent accessories. Data-15 |
| 377 | Supply and Installation of PA Mixer Amplifier 240W with all relavent accessories.Make:Bosch/Ahuja/EQ . Data-16 |
| 378 | Supply and Installation of Wall Speaker 30W with all relavent accessories. Make:Bosch/JBL DATA-17 |
| 379 | Supply and run of 2 Core 1.5 sq.mm Shielded Copper Speaker Wire in Existing PVC rigid pipe on wall and Ceiling and making good of portion with suitable colour DATA-18 |
| 380 | Supply and run of 8 Core 1.5 sq.mm PVC Copper Conference Ccable SR M2159 |
| 381 | Supply and Installation of 98, 4K, Andriod-13, INTERACTIVE TOUCH Professional Display with USB-C, HDMI-In & Out with all Accesories DATA-19 |
| 382 | Supply and run of HDMI Cable (20mtr) with HDMI spliters, VGA connectors, audio cable at both ends in 40mm PVC pipe and accessories. SR M2167 |
| 383 | Supply and fixing of 230 V operation 1 KVA single phase Servo Voltage stabilizer SR M 3082 |
| 384 | Supply and Installation of 19 Inch 17U Audio rack floor mount with necessory accessories. SR M 3098 |
| 385 | Earthing as per the ISI specification with an earth electrode of 2.1 mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mmx50mmx6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.(SD-221) |
| 386 | Supply and run of 1 of No.8 SWG GI wire for earth connection.(SD 74) |
| 387 | GST Please Enable Macros to View BoQ information |