| Sl. No. | Item Description |
| 1 | EXTERNAL DEVELOPMENT WORKS |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 3 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 5 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift (2 feet) |
| 6 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 7 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. (Depth - 230mm) |
| 8 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge) |
| 9 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (Rubber Mould)60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 10 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out comNew work (Two or more coats) |
| 11 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 12 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 13 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer |
| 14 | Providing and fixing 100 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 fine sand).Stone ware spout |
| 15 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :150 mm diameter |
| 16 | Supply of Soil Mix A (Quantity shall be checked at site after taking actual measurements by Client's and Contractor's representative) - Soil Mix A consists of Red soil-80%, Manure-20%. (200mm height approx.) |
| 17 | Supply and Laying of Mexican grass |
| 18 | Supply and Planting of Syzygium red - 1'6\\"-2' |
| 19 | Supply and Planting of Ficus panda - 1'6\\"-2' |
| 20 | Supply and Planting of Heliconia dwarf red - 1'6\\"-2' |
| 21 | Supply and Planting of Plumeria alba - 6\\"-8' |
| 22 | Irrigation & Dripping acessories for Landscaping (Note: Vendor to visit the site to understand actual site condition before submitting proposal for this work) |
| 23 | Providing, fabricating and erecting of MS Gate of Size 7.80 M X 1.50 M using structural steel members in position at all levels as specified in the drawings made out of standard MS sections conforming to IS 226/ 2062/ 800. Cost to include fabricating necessary gusset plates, stiffener plates, brackets, bolts, cleats, seating angles, etc., to the required size, shape, alignment, etc., as per the drawings. Cost to include welding of members using structural steel welding electrodes as per IS 814/ 816/ 817, testing as per IS: 7307 (Part-1), necessary equipments, tools and tackles, staging, required scaffolding, etc. complete, including a coat of zinc chromate primer and two coats of synthetic enamel painting. |
| 24 | SUB STRUCTURE WORKS |
| 25 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 2.0 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 26 | (Foundation filling, Basement filling) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 27 | Providing and laying Bitumen Penetration Macadam with hard stone aggregate of quality, size and grading as specified, with bitumen of suitable penetration grade, including required key aggregate as specified, spreading coarse aggregate with the help of self propelled/ tipper tail mounted aggregate spreader and applying bitumen by a pressure distributor and then spreading key aggregate with the help of aggregate spreader complete, including consolidation with road roller of minimum 8 to 10 tonne capacity to achieve specified values of compaction and surface accuracy :For 75 mm compacted thickness in two layers using stone aggregate of size 63-41 mm graded @ 0.90 cum per 10 sqm key aggregate of size 20.0 mm graded @ 0.18 cum per 10 sqm. With paving asphalt grade VG - 10 @ 68 kg/10 sqm. |
| 28 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level :Concrete of M15 grade with minimum cement content of 240 kg /cum |
| 29 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following gradesof concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 30 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 31 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 32 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 34 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 35 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 36 | Brick work with modular extruded brunt fly ash clay sewer bricks (Conforming to IS: 4885) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth : |
| 37 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) |
| 38 | 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) |
| 39 | 20 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) |
| 40 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 41 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 42 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : 2.35.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 43 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 44 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil |
| 45 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
| 46 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 47 | Weathering course concrete using best quality broken brick jelly of size 20mm uniform gauge in pure slaked lime the proportion of brick jelly to lime being 32 to 12 ½ by volume and laid over the RCC roof slab in a single layer and consolidated to the finished thickness by beating the concrete with wooden beaters of approved pattern keeping the surface constantly wet by sprinkling jaggery and lime water etc. Complete complying with standard specification. |
| 48 | Providing and fixing of 2 Hr Fire rated metal door double shutter (900mm+900mm) made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications. Necessary MS frame support to be provided from truce ceiling as per manufactures specification before fixing FRD. Door Closer - Dorma TS 91 cam action Door Closer with hold-open slide arm; Handle: Dorma - 450 mm High \\"D\\" type Handle; Hinges - Dorma 5\\" Flush suitable to Fire door. Note: all hadwares to be quoted for 2 shutters. M. (Note - Before ordering Cross Check the site for Dimension & get the approvel from the architect with shop drawing) |
| 49 | Providing and construction of HSD Yard with necessary civil works like retaining yard boundary wall with necessary alied civil works, 7ft height GI Metal chain linked fence (75x75mm chain link) with 75x75mm MS vertical column supports with 8' feet interval. Cost inclusive of necessary aluminium enamel painting. Yard floor to be filled with blue metal of size 40-60mm, with floor filling thickness of 150mm. Cost inclusive of necessary MS gate for entry. 5M - 4No. |
| 50 | Supply and fixing of MS Structure platform using ISMB section, MS angle for ODUs including safety handrails with supports. Scope shall include 2 coats of primer & 1 coat of anti corrosive painting. |
| 51 | PEB STRUCTURAL & PUF PANEL WORKS |
| 52 | Providing and Fixing of polyurethane foam as External Wall Thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted galvalume sheet with micro ribbed profile, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification. 50mm thick PUF external wall panel |
| 53 | Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels with both internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.150mm thick PUF Internal Partition wall panel |
| 54 | Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels with both internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.100mm thick PUF Internal Partition wall panel |
| 55 | Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels with both internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.30mm thick PUF Internal Partition wall panel |
| 56 | Providing and Fixing of polyurethane foam for Sloped roof as thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span, whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free, high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc & accessories such as screws, fastners, sealants etc for fixing the panel etc., complete complying with standard specification.50mm (+38mm) thick PUF roof panel |
| 57 | Primary Members (Frames, Built-Up members)Material Specification: IS2062 –High Tensile Structural Steel of E350/ASTM A572 grade 345 Mpa yield strength HR Material. Material Finish: Blasting with one coat of Zinc Rich Primer and two coats of Epoxy paint (100 Microns) Hot Rolled Members (Beams, Channels, Tubes, Pipes) Material Specification: IS 2062: 2006 Grade A with minimum yield strength of 250 Kn/m2.Material Finish: Blasting with one coat of Zinc Rich Primer and two coats of Epoxy paint (100 Microns) Bracing Members (Rods, Angles) Material Specification: IS 2062: 2006 Grade A with minimum yield strength of 250 Kn/m2. Material Finish: Blasting with one coat of Zinc Rich Primer and two coats of Epoxy paint (100 Microns) |
| 58 | Secondary Members (Purlins / Girts) Material Specification: 345 Mpa yield strength Material Finish: All Z and C Purlins coated with Zinc (GI) of 275GSM Coating Mass |
| 59 | Flashings and Trims Material Specification: 0.50mm Color Coated Galvalume AZ150 Coating with Minimum Yield Strength of 550MPA. Material Finish: 0.50mmTCT Color Coated Galvalume SheetHardware and Fasteners Material Specification: MS, HS Bolts for Structure and Self Stitching and Self Drilling Screws for Sheet fixingMaterial Finish: Electro Plated Yellow Chromate, Hot dipped Galvanized |
| 60 | INTERIOR & RESTROOM RELATED WORKS |
| 61 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 62 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 63 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. |
| 64 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M20 grade with minimum cement content of 270 kg /cum |
| 65 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 66 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 67 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 68 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 69 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 70 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick |
| 71 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 72 | Providing and fixing 75mm high Aluminium skirting of 1.5mm thick 75mm high extruded anodized aluminium skirting as per manufacture spec with necessart ply backing as per Architects approval. |
| 73 | Providing & fixing of 19mm thk., 200 mm wide Granite Threshold of approved Color. |
| 74 | Providing and fixing 12mm thk. commercial ply paneling finished in 1 mm thick. of approved shade laminate. 6X6 mm Aluminum \\"U\\" profile to be inserted to achieve uniform groove between gypsum and laminate paneling |
| 75 | Providing and fixing Commercial ply panelling, 12mm thk ply panelling finished with 6mm thk approved shade Lacquered Glass with suitable adhesive as per manufacturers specifications. 6X6 mm aluminium \\"U\\" profile profile section to be inserted b.w lacq glass and other finishes as per detail dwg. |
| 76 | Supply and Installation of Modular acosutic panel /Tile (Eco Panel board) of size 1200mm x 2400mm. 9 mm thk Eco board to be fixed over on gypsum parition / Wall. Cost inclusive of providing 6X6 mm Aluminum \\"U\\" channal section to achieve uniform groove between gypsum and Eco board paneling. Eco boards to be cut and installed to achive the pattern as per detail dwg provided by Architect. |
| 77 | Providing and fixing ply boxing of size 150X125 mm, made of 12mm thk. ply paneling finished with 1 mm thick. of Uni-color laminate. 6mmX6mm Aluminum \\"U\\" channal section to be inserted to achieve uniform groove between Laminate panel and other finishes. |
| 78 | Providing and fixing pelmets made of 18mm Pre laminated MDF Board of size 150mmx150mm wide along windows and glazed area and with necessary wood support, and also to mount the Blinds and Pull Down screens. The edges on the glazing side has to finished with enamel paint. |
| 79 | Providing and fixing 6mm thick commercial ply backing of 600mm x 600mm on mineral fibre modular false ceiling tiles to support light fitting, speakers, CCTV cameras, diffuser of grid work size with necessary cut outs for the same. |
| 80 | Providing and fixing 4 mm thk comm. Ply panel over on column / Gypsum partition / Wall |
| 81 | Providing and fixing 6 mm thk comm. Ply panel over on column / Gypsum partition / Wall |
| 82 | Providing and fixing 8 mm thk comm. Ply panel over on column / Gypsum partition / Wall |
| 83 | Providing and fixing 12 mm thk comm. Ply panel over on column / Gypsum partition / Wall |
| 84 | Providing and fixing 18 mm thk comm. Ply panel over on column / Gypsum partition / Wall |
| 85 | Supply and Installation of Half Height Toughened glass partition with 45mm x 25mm with minimum 1.5 -2mm thickness Polished Aluminium partition systems using snap on option for installing 10mm Toughened glass from 1200 to max 2400 mm. Only glass surface shall be measured and paid for this item. Aluminium profile frams to be used for all joints. |
| 86 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick f ixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including f ixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush f inish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. 75 mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) |
| 87 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) |
| 88 | Providing and fixing false ceiling at all heights including providing and f ixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and f inishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 89 | Providing and fixing 18mm thick laminated shutter finished with approved laminate shade, inside face of shutter to be finished in 1mm thick laminate of approved shade inclusive of providing & fixing of Aluminum Grill finished in approved shade powder coating for ventilation, approved handle, 225mm tower bolts, Locks etc complete as directed. |
| 90 | Providing and fixing trap door of size 1200 x 1200mm in the false ceiling for A/c units with Access for HVAC services in PVCwith all hardwares, locks etc. complete. |
| 91 | Providing and fixing trap door of size 600 x 600mm / 450 x 450mm. |
| 92 | Providing and fixing junction box cover in Various size from 150x150mm to 600x600mm of 19mm thick. commercial ply with necessary seasoned wood framework to prepare leveled surface for carpet. Including of civil work neatly finished and leveled around the junction box. |
| 93 | Providing and fixing Low height Storage of 750mm high and 600mm deep in Laminate (Inner & External Surface to be finished in Laminate) finish Rate to include of necessary nos of Godrej make locks, Slow Close hinges for shutter, approved handles, magnetic ball-catch, Intermediate shelf,Tower Bolt etc complete as directed. Cost inclusive of Postformed top, Postformed Shutter or Louverd shutter. |
| 94 | Providing and fixing Over head Storage of 600mm high and 450mm deep in Laminate (Inner & External Surface to be finished in Laminate) finish Rate to include of necessary nos of locks, Slow Close hinges for shutter, approved handles, magnetic ball-catch, Tower Bolt etc complete as directed. Cost inclusive of Postformed Shutte / Glass shutter. |
| 95 | Providing and fixing storage unit with 600mm wide Granite counter top of approved shade laid on 25mm thick PVC integral board with Storage below - Storage inner surface to be finished with white laminate and shutters to be in laminate finish with concealed aluminium profile handle as per detailed drawing. Cost inclusive of 200mm high Granite band above storage. |
| 96 | Aluminium Door Frame with Single leaf style shutter door - Providing and fixing doors with aluminium door frame of size 100 X 50 mm size with 75 X 40 mm Aluminium anodized profile frame shutters with 10 mm thk toughendglass, 5 Nos Hinges & acoustic door beading etc., Cost inclusive of providing 75 X 150 mm ply box and 600 X 600 mm aluminium frame work support from True Ceiling and provide necessary salwood / plywood support around door frame. |
| 97 | Aluminium Door Frame with Single leaf style shutter door - Providing and fixing doors with aluminium door frame of size 100 X 50 mm size with 75 X 40 mm Aluminium anodized profile frame shutters with 10 mm thk toughendglass, 5 Nos Hinges & acoustic door beading etc., Cost inclusive of providing 75 X 150 mm ply box and 600 X 600 mm aluminium frame work support from True Ceiling and provide necessary salwood / plywood support around door frame. |
| 98 | Providing and fixing of 2 Hr Fire rated metal door Single shutter made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications. (Door Closer - Dorma TS 91 cam action Door Closer with hold-open slide arm; Handle: Dorma - 450 mm High \\"D\\" type Handle; Hinges - Dorma 5\\" FLush suitable to Fire door. |
| 99 | Providing and fixing of 2 Hr Fire rated metal door Single shutter made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications. |
| 100 | Providing and fixing of 2 Hr Fire rated metal door double shutter (900mm+900mm) made of 1.6mm thk galvanized steel frames of size 140x57 mm with rebate and 1.2mm thk galvanized steel of 46mm thk double skin shutter with necessary infill materials and glue/sealant fixed in all respect including poly urethane paint with protective film coating and all accessories like hinges, lock, handles, door closers, with 6mm thk Toughened fire glass vision panel of size 200x300mm (without mesh) etc., as per the specifications. Necessary MS frame support to be provided from truce ceiling as per manufactures specification before fixing FRD. |
| 101 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 102 | Providing and fixing ball bearing for rolling shutters. |
| 103 | Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 10.00 sqm and upto 16.80 sqm in the area |
| 104 | Providing and fixing of 6mm thick lac.Glass fixed on 12 mm thk ply backing. Edges to be covered with 12 X 12 mm Aluminium anodized profile beading as per selection, |
| 105 | Providing and fixing pinup board made of 12 mm thk Jolly board with necessary ply backing support. Finished with approved Fabric. All edges to be covered with 12x12 mm Aluminium anodized profile Beading. |
| 106 | Providing and fixing of Pen Tray of Size 150X150 mm in acrylic finish. |
| 107 | Providing and fixing of Single seater sofa with back rest. |
| 108 | Providing and fixing Centre table of Size 600mm Dia with MS Powder coated leg and 25mm thk Membrane top. |
| 109 | Providing & applying Plastic Acrylic Emulsion Paint in minimum three coat, including preparation of surface, scrapping, sand papering, scaffolding etc complete. |
| 110 | Providing & applying Zinc Primer of approved shade and colour in single coat as per the standard. Cost inclusive of scaffolding etc complete. |
| 111 | Providing & applying Emulsion Paint in matt finish of approved shade and colour in minimum Two coat. Cost inclusive of surface preparing, scrapping, sand papering, scaffolding, etc complete. |
| 112 | Providing and fixing Printed Frosted film on Glass Partition with MCS warranty as per the manufacturer specification. |
| 113 | Providing and fixing Commercial grade Wall Paper of approved shade with recommended Adhesive of approved make which have 100% washable, Scratch resistance, Peel proof, & fire retardant properties. Cost to include preparation with Primer and 1 coat of emulsion on the punned surface / partition for receiving the wall paper as per the manufacturer specification. |
| 114 | Providing and fixing Vinyl graphics on wall with over laminate on wall with 3 yrs warranty as per the manufacturer specification. Cost to include preparation with Primer and 1 coat of emulsion on the punned surface/partition for receiving the vinyl poster as per the manufacturer specification. |
| 115 | Supplying & Installing CURTAIN BLINDS with Sunscreen perforated Roller blind optima series Basket 125 Tex with fabric specification of (Fabric compositition polyster 22% and PVC78%, Openenss Factor-5%, Thickness -0.68MM +/-5%, weight per m2 -480 GSM, yarns count in wrap/ weft/cm 19/18+/-5%, Fire Resistance-FR(USA) KFI(Korea), Tear Resistance-wrap11.9 daN+/ 5%,WEFT 150 daN+/-5%,colour fastness-6-7/8 (white colour base), artificial llight xenon lamp, UV resistance Min3 (White colour base), width 2.5M & 3 M. The Roller mechanism shall be a moulded unit made from engineering grade plastic polymer with PVC spring support. The Fabric shall be attached to the roller tube with high quality self adhesive tape with manual operation. The fabric shall be attached to the tube with adhesive strip. It should have minimum one ton fabric which must be placed on the roller before the working section of fabric start Operational action shall be smooth including necessary hardware for fixing at all places & as directed by Engineer-in-charge etc complete. The rate is inclusive of laying, conveyane, all other Tools and Plants involved in the work charges and all other incidental charges etc. complete and as directed by the engineer in charge. |
| 116 | Providing and fixing 1.5mm Anti - Corrosive Brushed SS Plate Engraved Room Name & Number, size 300mm x 100mm. |
| 117 | Providing and fixing 1.5mm Anti - Corrosive Brushed SS Plate Engraved Pull & Push, size 100mm x 50mm. |
| 118 | Providing and fixing 1.5mm Anti - Corrosive Brushed SS Plate Engraved No entry to unathorised persons, size 300mm x 100mm. |
| 119 | Providing and fixing of 25X25mm MS Box section frame welded together and finished with Black enamel paint. Top and bottom section of the frame to be finished with melamine polished 12mm thk Rubberwood. Inner surface to be covered with 12mm thk Rubberwood finish with melamine polish to be inserted into the MS frame work on all three sides to form a box profile to place planters or any artifacts. Outer suerface to be Covered with 12mm thk Ply and finished with melamine polished Rubberwood finish. Cost inclusive of providing planter box with Artifitial plants as per the attached Image / Dwg. Length as per the drawing, depth - 300mm, Height 1800mm. |
| 120 | UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Engineer in charge before use on work |
| 121 | UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 122 | Keeping the site reasonably clean and removal of debris from the site every day. Should also provide for thorough cleaning of site before handover. Should also include final cleaning of site before handover to client.House keeping : Dedicated collection and storage area with individual bins to be provided for collection of different type of waste as per Construction and Demolition Waste Management Plan. Collected waste to be disposed out of the site on regular basis (daily or alternative days). Vendor should ensure that debris, dust, dirt created by each and every vendor to be cleared by House keeping workers. There should be at least one vacuum cleaner of industrial type to be given for Housekeeping workers. Shifting of debris from site to designated area outside of site by trucks or tempo is also in the scope of House keeping works. This does not include the house keeping that happens on daily basis. Providing housekeeping agency for general housekeeping works of Please note that this house keeping people would be responsible for only general housekeeping and monitored by Project Managers at site. Debris removal : Removal of debris in truck from the specific location in the site and disposing the same from building premises on daily basis as per the instruction given by the client / PM / Base builder. |
| 123 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 124 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) |
| 125 | Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand)From ground level upto plinth level |
| 126 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 127 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 128 | Providing & fixing of 20mm thk. And 100 mm wide Granite Threshold with necessary related works of approved make & Color. |
| 129 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’. Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity |
| 130 | Providing and constructing single shutter door in 32mm thick blockboard finished with 1mm thk laminate provided with 200x300mm glass vision panel with 80 X 40mm Aluminium door frame up to required height (H) with 5 Nos Hinges & acoustic door beading etc., Cost inclusive of providing vision panel of size 200x300mm, 75 X 150 mm ply box and 600 X 600 mm aluminium frame work support from True Ceiling and provide necessary salwood / plywood support around door frame. Door Closer - Dorma TS 91 cam action Door Closer with hold-open slide arm / GEZE TS 3000 V; High \\"D\\" type approved Handle; Hinges - Dorma / Geze 5\\" Flush suitable to flush shutter; |
| 131 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 132 | Aerocon Light weight concrete filling up to 200-250 mm depth. cost inclusive of Providing top layer in 50 mm thk Grano Flooring. |
| 133 | Providing and fixing 600mm wide Wash basin counter made of polished 19mm thick granite slab top of approved shade laid on 25mm thick Marine Ply (IS:710) with suitable anto corrosion painted MS \\"L\\" angle grid frame supports, Includes 300mm high front facia & 100mm band above the counter top of same shade granite. All exposed surfaces of platform to be finished in same granite slab and all cut-out, exposed edges to be bull nosed with mirror polished. Cost to also include making necessary cut-outs for taking drainage pipes, Dust bins and Nahni traps in raised platform, all completed and finished to satisfactory conditions. |
| 134 | PHE WORKS - TOILET |
| 135 | Supply, fixing and testing of WHITE coloured vitreous china Wall mounted EUROPEAN WATER CLOSET with Exposed tank with ‘P’ trap, complete with solid plastic seat with cover, C.P. hinges and rubber buffers, 32mm dia C.P . cold water connection pipe including , C.P. bolts and nuts etc,. The work shall include cutting and making good the walls and floors etc. - |
| 136 | Supply, fixing and testing of 15 mm CP health faucet with bib tap of approved make with necessary CP flexible hose 1000 mm flexible tube, CP wall flange etc. |
| 137 | Supply, Installation, fixing, testing and commissioning of WHITE coloured vitreous china Rectangular WASH BASIN with brackets / G.I. rag bolts and nuts painted, 32mm dia brass C.P. waste coupling, (heavy) 32mm dia brass C.P. bottle trap, 15mm dia brass C.P. Angle stop cock with flange, 15mm dia brass C.P. cold water connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors. |
| 138 | Supply, Installation, fixing, testing and commissioning of wash basin table mounted CP pillar tap, required cp flanges,angle cock,flexible hose,extension nipples, etc complete, |
| 139 | Supply, fixing and testing of Robe hook with PVC rawl plug & C.P. brass screw complete as required. |
| 140 | Supply and fixing of tissue holder with PVC rawl plug & C.P. brass screw complete as required. |
| 141 | Supply, fixing and testing of shower assembly units consisting of wall mixer for controlling the rain shower, jet shower and spout, CP brass wall shower arrangement. including cutting, chasing & making good the walls. |
| 142 | Supply, fixing and testing of Stainless steel Soap dish with PVC rawl plug & C.P. brass screw complete as required. |
| 143 | Supply, fixing and testing of Towel rack with PVC rawl plug & C.P. brass screw complete as required. |
| 144 | Supply, fixing and testing of Towel ring with PVC rawl plug & C.P. brass screw complete as required. |
| 145 | Supply and fixing of white colour viterous china Urinal with pressmatic cock for flushing with in built waste grating, C.P.cast brass bottle trap with extension piece including CI/MS bracket wall flanges, flush piping, flexible hose,extension nipples, Sensing range of minimum 20cm, Control box operated by etc complete. |
| 146 | Supply and fixing of white colour viterous china Urinal divider with rawl plug, clamp etc complete |
| 147 | Supply and fixing of Tissue paper dispenser with PVC rawl plug & C.P. brass screw complete as required. |
| 148 | Supply and fixing of Liquid soap dispenser with PVC rawl plug & C.P. brass screw complete as required. |
| 149 | Supply and fixing of solid state, no touch operting, fully hygienic hand drier of approved shade with single blower, with time delay, summer & winter control, music while drying, volume ON/OFF controls. |
| 150 | Supply, fixing and testing of racold / AO Smith make electically operated storage 15 L water heater inner container made from copper or stainless steel including the instalation safety valve, vacuum relief valve, neon lamp, mounting brackets, installing in position with coach screws or bolts, nuts, testing, commissioning, etc, complete. 15mm dia Angle stop cock with wall flange, 15mm dia C.P . hot and cold water connection pipe including , C.P. bolts and nuts etc,. The work shall include cutting and making good the walls and floors etc. |
| 151 | Supply, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI 'U' clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. |
| 152 | a) 75mm dia (6kg/sq.cm pressure rated - Type - B) |
| 153 | b)110mm dia (6kg/sq.cm pressure rated - Type - B) |
| 154 | Supply, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. |
| 155 | a)40mm dia (10kg / sq.cm) |
| 156 | b)50mm dia (10kg / sq.cm) |
| 157 | Supply, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (150 mm x 150 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) |
| 158 | Supply and fixing of CP grating cover (150mmx150 mm). for drain outlet etc., complete.(The frame and grating shall be approved by Architects) |
| 159 | Supply, fixing and testing of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50 mm dia SDR.11.0, ASTM CTS, and above 50 mm dia CPVC schedule 40 ASTM IPS. Fittings up to 50 mm dia SDR 11. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc., with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in geru mixed cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50 mm dia as per ASTM D-2846 and above 50 mm dia primer P-70, and solvent confirming to ASTMF-4931 / 724. |
| 160 | a) 20 mm dia |
| 161 | b) 25 mm dia |
| 162 | c) 32 mm dia |
| 163 | d) 40 mm dia |
| 164 | e) 50 mm dia |
| 165 | Supply, fixing and testing of Full Bore Forged Brass Ball Valve Screwed End. |
| 166 | a) 20 mm dia |
| 167 | b) 25 mm dia |
| 168 | c) 32 mm dia |
| 169 | d) 40 mm dia |
| 170 | e) 50 mm dia |
| 171 | PHE WORKS - KITCHEN & EXTERNAL |
| 172 | Supply of Grease separator for non vehicular movement area made of polyethylene as per DIN EN 1825; for below ground installation; 2 x maintenance openings; with ventilation provision; emptying via suction line DN 65 PN 10; counter flange with fire hose quick coupling 75B and 2½\\" blank cap and satisfy reaction to fire Class A .2x Standard odour tight top cover of 600 mm dia. clear opening; frame made of concrete material and cover made of cast iron; with raising tube, load class A15 according to EN 124Inlet and outlet dia: DN 200Nominal Size: NS 20Grease Storage: 820L, Sludge Storage: 2000L, Overall Capacity: 3565L Grease level monitor to consider with panel requiredImportant Note:-It should be cleaned periodically 10 - 15 working days by tanker. |
| 173 | Supply, Installation, fixing, testing and commissioning of CP angle cock with extension braided hose of 600mm length , required cp flanges, extension nipples,etc., |
| 174 | Supply, Installation, fixing, testing and commissioning of Stainless steel 304 smooth round edge gratings (Size - 900x300mm) with deep drawn silt bucket and removable foul air tap, Complete, It should etc., |
| 175 | Supply, fixing, testing and commissioning of polypropylene pipe confirming to dimensions as per standard EN 1451 Series S16, Water Temp. up to 95 deg C/ 203 deg F(intermittent) or 90 deg C/194 deg F(Continuous) of including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, Soil & waste pipe line laid underground level. |
| 176 | a) 40mm dia |
| 177 | b) 50mm dia |
| 178 | c) 75mm dia |
| 179 | d) 110mm dia |
| 180 | e) 160mm dia |
| 181 | Supply,fixing and testing of Polypropylene floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) 0with brass CP frame & cover (150 mm x 150 mm). Trap of 100 mm dia inlet and 110 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) (Location : Washbasin) |
| 182 | Supply, fixing and testing of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50 mm dia SDR.11.0, ASTM CTS, and above 50 mm dia CPVC schedule 40 ASTM IPS. Fittings up to 50 mm dia SDR 11. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc., with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in geru mixed cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50 mm dia as per ASTM D-2846 and above 50 mm dia primer P-70, and solvent confirming to ASTMF-4931 / 724. |
| 183 | a) 20 mm dia |
| 184 | b) 25 mm dia |
| 185 | c) 32 mm dia |
| 186 | d) 40 mm dia |
| 187 | e) 50 mm dia |
| 188 | Supply, fixing and testing of Gunmetal Ball Valve/ Brass full way valve with C.I. wheel Screwed End. |
| 189 | a) 20 mm dia |
| 190 | b) 25 mm dia |
| 191 | c) 32 mm dia |
| 192 | d) 40 mm dia |
| 193 | e) 50 mm dia |
| 194 | Supply, fixing and testing of Gunmetal non-return valve-horizontal (screwed end) |
| 195 | d) 50 mm dia |
| 196 | Supply, fixing and testing of Y-Strainer Including Permanent Magnet, Flanged End with Drain Connection, Body : IS 210 Gr FG 200, Screen : SS 304, Ends : Screwed To BSP, Hyd -Test Press.: BODY: 15 Kg/Cm² |
| 197 | c) 50 mm dia |
| 198 | Supply, fixing and testing of brass Automatic Air release valve approved quality for booster line & Vertical |
| 199 | a) 20 mm dia |
| 200 | Supplying, installing, fixing, jointing, testing and commissioning of brass Electromagnetic Water flow Meter with BMS integration screw type tested to 16 kg / sq.cm. |
| 201 | c) 50 mm dia |
| 202 | Automatic OHT Level Control System, Contains Float switch and separate control panel arrangement for auto on/off in Each tank. |
| 203 | Supply, fixing and testing of PVC soil, waste and vent pipe confirming to IS 4985 of 10 kg / sq.cm pressure rated, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI 'U' clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. |
| 204 | a) 75mm dia (10kg/sq.cm pressure rated) |
| 205 | b)110mm dia (10kg/sq.cm pressure rated) |
| 206 | d)200mm dia (10kg/sq.cm pressure rated) |
| 207 | Supply, fixing and testing of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) up to 50 mm dia SDR.11.0, ASTM CTS, and above 50 mm dia CPVC schedule 40 ASTM IPS. Fittings up to 50 mm dia SDR 11. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc., with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in geru mixed cement mortar 1:1 restore the same original condition neatly as directed by the Engineer in-charge. Joints to be made with CPVC solvent cement up to 50 mm dia as per ASTM D-2846 and above 50 mm dia primer P-70, and solvent confirming to ASTMF-4931 / 724. |
| 208 | a) 20 mm dia |
| 209 | b) 25 mm dia |
| 210 | c) 32 mm dia |
| 211 | d) 40 mm dia |
| 212 | e) 50 mm dia |
| 213 | Supply, fixing and testing of glazed stoneware Gully trap, 300x300M C.I. grating ( medium duty), 100 mm dia outlet set in PCC 1:4:8 bed, 115 mm thick masonary chamber in CM 1:4, internal and external plastering 12mm thick in CM1:6, necessary earthwork, C.I. cover (medium duty) etc. Complete. |
| 214 | Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 200 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC cover, benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 600mm |
| 215 | Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 200 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 900x800 mm size internal and depth will 600mm to 900mm |
| 216 | Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 200 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 1200x900 mm size internal and depth will 900mm to 2500mm Please Enable Macros to View BoQ information |
| 217 | Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 200 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 1200x900 mm size internal and depth will 900mm to 2500mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail