Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil 0.00 TO 1.50 MTR. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil 1.50 TO 2.00 MTR. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 6 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement:2 coarse sand) to match the existing floor.With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources)- Tie Beam. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources)- Footing |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)- Column |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 12 | Painting on D.P.C. with two coats of airblown bitumen 85/50 or 85/25 @ 1.7 kg/sqm approx. including cost of fuel if any. |
| 13 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 14 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Ground Floor |
| 19 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). First Floor |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).Terrace Floor |
| 21 | As in item no. 1 above but for slabs (Using 1:1.5:3 Mix concrete). Ground Floor |
| 22 | As in item no. 1 above but for slabs (Using 1:1.5:3 Mix concrete) First Floor |
| 23 | As in item no. 1 above but for slabs (Using 1:1.5:3 Mix concrete) Terrace Floor |
| 24 | As in item 1 but for the lighter beams i.e. having spans upto 6 m.Ground Floor |
| 25 | As in item 1 but for the lighter beams i.e. having spans upto 6 m. First Floor |
| 26 | As in item 1 but for the lighter beams i.e. having spans upto 6 m Terrace Floor |
| 27 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Ground Floor |
| 28 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :First Floor |
| 29 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Terrace Floor |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) Ground Floor |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) First Floor |
| 32 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)Terrace Floor |
| 33 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) Ground Floor |
| 34 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) First Floor |
| 35 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) Terrace Floor |
| 36 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. Ground Floor |
| 37 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. First Floor |
| 38 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in anover all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. Terrace Floor |
| 39 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) Ground Floor |
| 40 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) First Floor |
| 41 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) Terrace Floor |
| 42 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) Ground Floor |
| 43 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) First Floor |
| 44 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) Terrace Floor |
| 45 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 46 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (flooring) Ground Floor |
| 47 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (flooring) First Floor |
| 48 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (flooring) Terrace Floor |
| 49 | Providing edge double moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work Ground Floor |
| 50 | Providing edge double moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work First Floor |
| 51 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (skirting) Ground Floor |
| 52 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (skirting) First Floor |
| 53 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. (skirting) Terrace Floor |
| 54 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm Ground Floor |
| 55 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm First Floor |
| 56 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm Ground Floor |
| 57 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm First Floor |
| 58 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick Ground Floor |
| 59 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (FLOORING) Ground Floor |
| 61 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (FLOORING) First Floor |
| 62 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Ground Floor |
| 63 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. First Floor |
| 64 | Cement concrete flooring 1:2:4 (1 cement ; 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry but excluding the cost of nosing of steps etc. complete.25 mm thick with 20 mm nominal size stone aggregate |
| 65 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. |
| 66 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (b) Double leaf |
| 67 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 68 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) Second class teak wood.30 mm thick shutters |
| 69 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ('1 Cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 70 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4 mm thick |
| 71 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (Outer surface) Ground Floor |
| 72 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (Outer surface) First Floor |
| 73 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm (Outer surface) Terrace Floor |
| 74 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) Ground Floor |
| 75 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) First Floor |
| 76 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface)Terrace Floor |
| 77 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Ground Floor |
| 78 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. First Floor |
| 79 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Terrace Floor |
| 80 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 81 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 82 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm |
| 83 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 84 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 85 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 86 | Providing & applying 100% solids, flexible, elastomeric, UV stable, 2 component, waterproof, fast setting, monolithic, hydrophobic in nature, NO-VOC, CFTRI-US-FDA-175-300 coating on prepared surface as following :-P/L DONCRETE/EQUIVALENTPP solvent free primer @ 100gsm per m2 forconjunction of DONCRETE/EQUIVALENT PU conforming to ASTM-D-2369 C,ASTM-D-2369, ASTM-D-638, ASTM-D-4541, ASTM-D- 638, ASTMD-2240, ASTM-E-96, ASTM-B-117-73, ASTM-D-91, ASTM-D-624, ASTM-D-4060, ASTM-C-8, ASTM-D-512, ASTM-G-53, ASTM-3912@ 1 Ltr per m2 for 1.00 mm thick. The coating shall be carried out in single application with multiple passes, using high pressure plural component reactor strictly as per manufacturespecification, rate materials, labor, and tools. Surface preparation includes repairs of holes, cracks, voids, pinholes, bug holes. Joints shall be filled with epoxy putty Confirming the ASTM D 638, ASTMD 4541, and ASTM D 2369. The corner rounding/angle fillet shall be prepared/replaced as required to smooth transition of coating from horizontal to vertical surfaces. |
| 87 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 88 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture : (M.S. & woood works). |
| 89 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size 24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre Antimicrobial false ceiling tile confirming to ISO 5 (class 100) specifications. (Suspension system to have sillhoute profiles) - (Knauf ceiling solutions) |
| 90 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 91 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 92 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 93 | ELECTRICAL BOQ OF KALYAN MANDAP AT HATHI KHANA |
| 94 | General Notes: |
| 95 | Separate neutral and earthing wire shall be provided for each circuit. |
| 96 | Lighting and power circuit to be kept separate. |
| 97 | Wiring shall be as per specification and as per electricity rules & regulations. |
| 98 | Approved GI saddles and grouting the same for exposed conduit work. |
| 99 | 1.0 mm thick GI Outlet box and junction box, weld free, having integrated mounting clip & earth pin for easier installation with removable side plates for easier wiring as per IS: 14772 |
| 100 | All fixing accessories such as clips, brass screws pull boxes etc. complete in all respect. |
| 101 | Embedding conduits and accessories in walls and floors etc. during construction and / cutting chases (with chase cutting machine) and making good the same as necessary in the case of concealed conduit work. |
| 102 | Repainting of PVC conduits, outlet box and junction box where ever damaged. |
| 103 | Expansion joints for conduiting etc. shall be provided in case of crossing of building expansion joint and as approved by engineer in-charge. |
| 104 | Conduits shall be terminated in switch & socket boxes / DB’s with nuts & check nuts and brass bushes. |
| 105 | WIRING |
| 106 | Wiring for the light points with following size PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in existing concealed or surface mounted 25 mm dia 16 gauge MS black enamelled Conduit including wire connectors complete in all respect. |
| 107 | 2 x 2.5 sq.mm +1 x 2.5sq.mm (DB to switch board) |
| 108 | 2 x 2.5 sq.mm +1 x 2.5sq.mm (Switch board to switch board) |
| 109 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm(Switch board to Light First Point) |
| 110 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm(First Point to Light loop point) |
| 111 | Switch Board |
| 112 | Point |
| 113 | 2 x 1.5 sq.mm + 1 x 1.5 sq.mm(First Point to Light loop point) |
| 114 | 2x2.5 sqmm +1 x 2.5 sqmm (MCB to Light First Point) |
| 115 | Point |
| 116 | Wiring for the power points with following size PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in existing concealed or surface mounted 25 mm dia 16 gauge MS Conduit complete in all respect. (for power points) |
| 117 | 2 x 4.0 sq.mm +1 x 4.0 sq.mm (DB to 16A socket) |
| 118 | 2 x 4.0 sq.mm +1 x 4.0 sq.mm (16A to 16A socket) |
| 119 | 2 x 2.5 sq.mm +1 x 2.5 sq.mm (16A to 6A socket) |
| 120 | 2 x 2.5 sq.mm +1 x 2.5 sq.mm (DB to 6A socket) |
| 121 | 2 x 2.5 sq.mm +1 x 2.5 sq.mm (6A to 6A socket) |
| 122 | 2 x 6.0 sq.mm +1 x 6.0 sq.mm (DB to 25A socket) |
| 123 | Modular Box |
| 124 | Supply & fixing of following size/module GI Box along with modular base & cover plate for modular switch sockets as required. |
| 125 | 1/2MODULE BOX |
| 126 | 3 MODULE BOX |
| 127 | 4 MODULE BOX |
| 128 | 6 MODULE BOX |
| 129 | 8 MODULE BOX |
| 130 | Switch & Sockets |
| 131 | Supplying & fixing of following modular switch, socket on existing modular cover plate & switch box including connection but excluding modular plate etc. as required. |
| 132 | 16A SP SOCKET |
| 133 | 16A SP SWITCH |
| 134 | 6A SP SOCKET |
| 135 | 6A SP SWITCH |
| 136 | Conduit |
| 137 | Supplying and laying of following sizes of black enamelled PVC conduit in recess/on surface including all accessories All fixing accessories such as clips, brass screws pull boxes etc. complete in all respect, fixing hardware such as brass bushes, bends, pull boxes, junction boxes etc. and other fittings shall be considered, including chasing the wall/floor and plastering the chased portion and making good the damages etc complete as required. conduit shall be supported by Saddles to be provided at every one meter. Saddles shall be provided at 300mm at bends. as and where needed for small connections. |
| 138 | 25 mm Dia PVC Conduit 1.6 mm wall thickness. |
| 139 | 32 mm Dia PVC Conduit 2mm wall thickness. |
| 140 | Supplying and fixing of following sizes of PVC flexible conduit including all accessories, fixing hardware including conduit gland etc. 25 mm Dia PVC flexible conduit |
| 141 | INSTALLATION OF LIGHT FIXTURES |
| 142 | Shifting, storing, Installation, testing & Commissioning of the following lighting fixtures with all fixing accessories etc. as required. |
| 143 | 7 WATT LED DOWN LIGHER |
| 144 | MIRROR LIGHT (5WATT) |
| 145 | CABLING WORKS (MAINS AND SUB MAINS) |
| 146 | Effective, adequate and proper connections at terminations. |
| 147 | Providing all fixing accessories such as clamping devices nuts, bolts and screws. |
| 148 | Wherever the cables are of aluminium and bus bars of copper bimetallic lugs shall be used. |
| 149 | All cable shall be laid with one diameter gap. |
| 150 | All cables shall be IS approved. |
| 151 | Fire retardant paint one meter on both side of wall penetration and at termination as per specifications. |
| 152 | All cutouts / Sleeves shall be sealed with fire retardant sealant (to be paid separately) as per specification. |
| 153 | Supplying , laying & Commissioning of following 1100 volt grade XLPE insulated PVC sheathed aluminium /copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped includes anchor fasteners wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. |
| 154 | 3.5CX50 Sqmm cu. Ar. XLPE cable |
| 155 | 4CX25 Sqmm cu. Ar. XLPE cable |
| 156 | Cable end termination of the following XLPE insulated PVC sheathed aluminium / copper conductor armoured cables of 1100 volt grade including supplying and fixing of crimping aluminium/copper lugs, double compression glands with earthing facility at both ends of cables etc. complete as required. |
| 157 | 3.5CX50 Sqmm cu. Ar. XLPE cable |
| 158 | 4CX25 Sqmm cu. Ar. XLPE cable |
| 159 | EARTHING (FOR DISTRIBUTION SYSTEMS INCLUDING DG, EQUIPMENTS, PANELS & DB'S) |
| 160 | Rates shall also include the following : |
| 161 | All fixing accessories such as brass saddles, brass screws rawl plugs etc. |
| 162 | Jointing by rivetting and brazing after rivetting in case of copper and welding / bolting in case of GI earthing. |
| 163 | Cutting chases holes and making good the same wherever required. |
| 164 | Effecting adequate and proper interconnections. |
| 165 | Use of copper thimbles. |
| 166 | Earthing system shall comply to IS:3043-1987. |
| 167 | All earthing pits shall be interconnected. |
| 168 | All equipment motors, DB’s, panels to be connected on either ends (double earthing) with suitable strip / wires. |
| 169 | Supply and installation of advanced maintenance free Earthing System consisting of 1 Nos. CPRI tested copper bonded steel electrode of 20 mm dia each With a min. coating thickness of 250 microns and length of 3 meters. 25 kgs/Electrode of earth enhancing compound needs to be considered to fill the 100mm augered hole surrounding to the electrode. The rate shall include excavation of earth, filling with back fill compound, and earth pit marking. The Complete installation shall be as per the drawing and technical specifications. |
| 170 | Supply of 20 mm dia. Copper bonded carbon steel core Electrode tested according to IEC 62561-2 - |
| 171 | SS Universal Clamp of Size 175X50X3 mm for connection Terminal |
| 172 | Supply of Earth enhancing compound(OEC) tested as per IEC 62561-7 - Make OBO Bettermann / furse |
| 173 | Poly Propilene Heavy duty Pit cover |
| 174 | Installation charge of above items |
| 175 | Supply, Testing & Commissioning, fixing of following bare Copper /GI flat/ Wires including all necessary fixing accessories and effecting connections as per specifications. 25 mm x 6mm GI strip |
| 176 | DISTRIBUTION BOARDS |
| 177 | Supply, unloading, shifting, installation, testing & commissioning of following Distribution Boards with IP 42 along with copper bus-bar, neutral links and earth terminals all enclosed in MS box complete with hinges, metal covers, interconnections bonding to earth:- Make : Schneider / Legrand UDB-1 LOC: GROUND & FIRST FLOOR (16 WAY SPN DB) |
| 178 | Incomer- |
| 179 | 1 No. 63A DP MCB (25KA ) |
| 180 | 3 No. 40A DP RCCB (300MA ) |
| 181 | Outgoing- |
| 182 | 12 Nos. 10A SP MCB (5KA ) |
| 183 | 12 Nos. 20A SP MCB (10KA ) |
| 184 | Neutral Link |
| 185 | Suitable for above outgoings. |
| 186 | Earthing Bus |
| 187 | Suitable for above outgoings. |
| 188 | UDB-1 LOC: GROUND & FIRST FLOOR (16 WAY SPN DB) |
| 189 | Incomer- |
| 190 | 1 No. 40A DP MCB (10KA ) |
| 191 | 1 No. 40A DP RCCB (300MA ) |
| 192 | Outgoing- |
| 193 | 8 Nos. 16A SP MCB (8KA) |
| 194 | 4 Nos. 10A SP MCB (5KA) |
| 195 | Neutral Link |
| 196 | Suitable for above outgoings. |
| 197 | Earthing Bus |
| 198 | Suitable for above outgoings. |
| 199 | UPS SYSTEM |
| 200 | The rate shall include the following : 'All applicable taxes Installation of Equipment Testing of Equipment as per IS and specifications, at manufacturer's workshop prior to dispatch dully witnessed by client and consultant, if required. 'Delivery of the equipment at site. 'Unloading of equipment at site. 'Shifting of equipment with all tools, equipment & accessories from site store to the site & placing it on the plinth at site. 'Installation and assemble of equipment at site 'Earthing of equipment neutral & body. 'Testing of equipment as per IS before commissioning. Charging of equipment gradually as per IS.Battery shall be fully charged at the time of handing over of equipment To prepare submission drawing and to take approval of consultant at each stage. To prepare & submit as-built drawing and handing over document to end user. |
| 201 | Supply, Installation, Testing and Commissioning of (Single phase, 2 wire IN & Single phase, 2 wire OUT) 2.5KVA online UPS suitable for input and output parameters strictly as per specifications with built in isolation transformer. The UPS shall be provided in powder coated fan cooled enclosure painted in colour as per specifications. The UPS shall be suitable for normal, emergency, recharge, by-pass and maintenance mode. The system be expandable in such a manner that addition of another UPS of similar capacity can double the system output with common by-pass. The UPS shall have a microprocessor based display and control panel. UPS shall have enclosed batteries with rack, having 60 minute back-up.Make: APC / Numeric-Legrand / Emerson |
| 202 | Input voltage : 215V to 220V,1ph+N+PE ±10% |
| 203 | Output voltage : 220 V,1 phase ±2% |
| 204 | Battery charger Auto / Manual float cum Boost .The rate shall include overvoltage cut-off , undervoltage trip. |
| 205 | 2.5 KVA Online UPS with 60 minutes battery back-up. |
| 206 | Receiving storing shifting to site of installation, installation testing and commossioning of 2.5 KVA online UPS |
| 207 | Plumbing Work |
| 208 | Chlorinated Polyvinyl Chloride (CPVC) SDR‐11 pipe(work within toilet) |
| 209 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, multi‐layer having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the alls etc. |
| 210 | 15 mm nominal outer dia Pipes |
| 211 | 20 mm nominal outer dia Pipes |
| 212 | Chlorinated Polyvinyl Chloride (CPVC) SDR‐11 pipes (work within shaft & ring line for water supply ) |
| 213 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,.having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 214 | 20 mm nominal outer dia Pipes |
| 215 | 25 mm nominal outer dia Pipes |
| 216 | Providing, fixing and testing heavy quality gun metal ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ ZOLOTO make)(For work shaft to toilet connection) |
| 217 | 20 mm (3/4\\") dia. |
| 218 | 25 mm (1\\") dia. |
| 219 | 32 mm (1 1/4\\") dia. |
| 220 | Providing and fixing single acting air release valve with Screwed inlet 50mm dia |
| 221 | Providing and fixing ball Cock (brass) of approved quality, High pressure, with plastic floats complete. (Note: Presure should be 10 KG/Sq.Cm) |
| 222 | Providing and fixing of food grade uv protected 2000 liter PVC water tank |
| 223 | Internal Drainage |
| 224 | S / F 75 mm internal dia. 3.5 mm thk. centrifugally cast C. I. pipes Confirming to IS 3989, sockets spigots type pipe for rain water/soil waste and ventilation with all fittings including scaffolding, 1:1 CM jointing properembedding and fixing on wall & column etc complete as directed. |
| 225 | S / F 100 mm internal dia. 4.0 mm thk. centrifugally cast C. I. pipes Confirming to IS 3989, sockets spigots type pipe for rain water/soil waste and ventilation with all fittings including scaffolding, 1:1 CM jointing properembedding and fixing on wall & column etc complete as directed. |
| 226 | Supplying & Fixing Agricultural PVC 10 kg class pipe as IS 4985‐2000 of Approved make with P.V.C. fittings including Chasing of Brick wall & making good the same with 1:3 cement sand plaster using Chiken wire mesh etc.complete.(For wash basin , sink drains, vent and Urinal outlet ) 40 mm (1 1/2\\") dia. |
| 227 | Providingand fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. |
| 228 | 75 mm C.I Nahani trap with grating with 75 mm C.I. bend with cleaning caps fixed compleate(for work in toilet) |
| 229 | Providig & Supplying & Fixing 100 mm dia. CI 'P' trap Suspended type floor Drain of standard design. with EPDM rubber gasket jointng as pe DIN‐19543, ASTM C 1277‐4. |
| 230 | P & F UPVC Cowl Cap of Size 75 mm |
| 231 | P & F UPVC Cowl Cap of Size 110 mm |
| 232 | External Drainage |
| 233 | Constructing on sewer brick masonry conical manholes 1.2M dia. at bottom0.56 M. dia. at top, built in brick masonry in cement mortar 1:3, plastered both inside and outside with 20 mm thick cement mortar 1:2 and neat cement rendering so as to give a smooth surface, including 300 mm thickM.15 cement concrete in foundation and in haunches and channels finished smooth with 20mm thick cement plaster in cement mortar 1:1 and providingC.I. steps (weighing 5.4 kg each) staggered at 300 mm. c/c including 75mm wide vata all round the external portion of the manhole and the foundation concrete in cement mortar 1:1 and supporting the incoming pipes with brick masonry wherever necessary including C.I. extra heavy duty (EHD) air‐tight circular frame & cover (minimum 230 Kg.) with hinge/chain resting on 30 cm high cement concrete M.20 cap with necessary centering etc. all complete as per standard specifications and directions including finishing the cap with cement plaster on both sides 1:2 and neat cement rendering so as to give a smooth surface in line and level with the brick masonry surface and as per drawing inDyCh.E.(Sewerage)P&D's office withoutexcavation depth upto 1.5 M.(Depth of Manhole measured from top of manhole cover to Invert level of manhole |
| 234 | Providing and fixing square‐mouth S.W. gully trap class SP‐1 Complete withC.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of Cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 235 | Supplying, laying, jointing & testing UPVC Drainage class pipes of Foamcore Astral(SN 8) or equivalent make in solvent cement joint including leveling with cutting the pipe to required length, roughining of pipe at wall joint including socket as directed: 150 mm pipe |
| 236 | P / L cement concrete 1:4:8 all‐round S.W. pipes including bed concrete as per standard design 150 mm diameter S.W. pipe. |
| 237 | Sanitary Fixtures |
| 238 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. Pan With ISI Marked White Solid Plastic Seat and Lid. |
| 239 | Providing and fixing C.P. Brass two way bib cock with flange of approved quality and make. |
| 240 | P / F Health Faucet with one metre long easy flex tube in chrome finish and wall flange. |
| 241 | Providing and fixing JAQUAR MAKE, PRESSMATIC Taps Model No. 031 Pillarcock Auto closing system etc complete |
| 242 | White Vitreous China of 'Hindustan & Parryware' make or equivalent under counter type Oval wash basin of size 550 x 480mm with CI brackets suitable for mounting below granite counter including waste fitting with CP brass bottle trap, angle valve with CP connection etc as specified. Oval Wash Basin Model No.10051 OR consider equivalent make.) |
| 243 | P / F P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittingscomplete Flexible pipe 40 mm dia\\" |
| 244 | P / F PTMT Bottle Trap for Wash basin and sink Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimumwater seal, weighing not less than 263gms. |
| 245 | P / F PTMT liquid soap container 109mm wide, 125mm highand 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105gms. |
| 246 | P / F PTMT soap Dish Holder having length of138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than106 gms. Please Enable Macros to View BoQ information |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy