| 1 | Compound Wall Construction & Dismantling Existing Toilet |
| 2 | 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar |
| 3 | OD504089/2025-2026:Random rubble masonry withl Cement mortar 1:6 (1 cement : 6 coarse sand) with hard stonein foundation and plinth as per direction of engineer in charge at site (Modified 7.1.1.) |
| 4 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 5.22.5:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHard drawn steel wire fabric |
| 6 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 7 | 50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 8 | 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). |
| 9 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 10 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 11 | Hospital Maintenance |
| 12 | 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar |
| 13 | 15.1:Demolishing lime concrete manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer - in- Charge. |
| 14 | OD336421/2025-2026:Engaging Man Koolies |
| 15 | OD504156/2025-2026:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitchofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthicknesswith zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should haveprotective guard film of 25 microns minimum to avoid scratchesduring transportation andshould be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheetshall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal,complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins,rafters and trusses and including cutting tosize and shape wherever required.(Modified 12.50) |
| 16 | 21.5:Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). |
| 17 | 50.12.4.2:Providing and fixing false ceiling with 7.5 mm thick PVC wooden grains panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) |
| 18 | 9.3.2:Providing wood work in frames of false ceiling, partitions etc. sawn and fixed inposition with necessary stainless steel screws etc.Kiln seasoned and chemically treated hollock wood |
| 19 | 50.9.11.2:Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately)as per the direction of site Engineer-in-charge. |
| 20 | 50.9.11.1:Providing and fixing Thomson Multi wood board or equivalent make paneling 12 mm thick, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately) as per the direction of site Engineer-in-charge. |
| 21 | 50.9.7.1:Providing and fixing 25 mm thick shutters for cup board etc. Paneled or paneled & glazed shutters using Anjili/ Jack wood including ISI marked anodized aluminium butt hinges with necessary screws. |
| 22 | 50.9.9.1:Providing and fixing 25 mm thick shutters for cup board etc. glazed shutters using Anjili/ Jack wood including ISI marked anodised aluminium butt hinges with necessary screws. |
| 23 | 50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 24 | 50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood |
| 25 | 50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood |
| 26 | OD504191/2025-2026:Providing and Fixing Factory made PVC Door including of all fittings and labour charges etc..to complete as per the direction of departmental officers. |
| 27 | Tile Laying Back Side of Hospital |
| 28 | 2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil |
| 29 | OD424745/2025-2026:Construction of granular sub- base by Providing close graded Material conforming tospecifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippersto work site, for all leads & lifts, spreading in uniform layers of specified thickness withmotor grader on prepared surface and compacting with vibratory power roller to achieve thedesired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 (without roller) |
| 30 | OD436198/2025-2026:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M- 30 grade made by block making machine with strong vibratory compaction, of approved size,design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of stone aggregate, etc. all complete as per the direction of Engineer-in-charge.OD 80/21-22 |
| 31 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Please Enable Macros to View BoQ information |