| 1 | Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick). |
| 2 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC.(In Ground Floor)(a) One Coati) Water based interior grade Acrylic Primer |
| 3 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty.(Two coats)i) Luxury Quality |
| 4 | (a) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 5 | (b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 6 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : |
| 7 | a) On timber or plastered surface :With super gloss (hi-gloss) -i) Two coats (with any shade except white) |
| 8 | b) On steel or other surface :With super gloss (hi-gloss) -i) Two coats (with any shade except white) |
| 9 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well-seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. i) 32 mm thick shutters (single leaf) |
| 10 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating , nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (A)1:4 Cement Sand Mix (I) 20 mm Thk. |
| 11 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. |
| 12 | (i)100X50X1.25mm |
| 13 | (ii)75X40X1.12mm |
| 14 | Iron hasp bolt of approved quality fitted and fixed complete (oxidized) with 16mm dia. rod with center bolt and round fitting. i)250 mm. Long x 16mm. |
| 15 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. |
| 16 | i) 100mm long x 10mm dia. bolt |
| 17 | ii) 225mm long x 10mm dia. bolt |
| 18 | Iron door handle of approved quality fitted and fixed complete i) 100mm x 5mm |
| 19 | Godrej Hydraulic door closer fitted and fixed complete.Heavy type |
| 20 | Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 21 | Door stopper (Anodised aluminium) |
| 22 | French polishing to wood work including preparing surface (ordinary gloss). |
| 23 | (a) On new wood work. |
| 24 | (b) On old French polished surface including complete removal of the old polish. |
| 25 | Partition of commercial ply as per design fitted and fixed complete (excluding the supporting framework but including necessary teak wood battens of size 40mmx 25 mm):In Ground Floor i) 12mm thick |
| 26 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & up to 6 m height for external wall)(i) 3 mm thick (weighing 7.4 kg/Sq.m). |
| 27 | Renewing worn out putty of glass panes (i) Panes not exceeding 0.2 Sq.m |
| 28 | Dismantling of the following :-(a)Stripping off worn out plaster and racking out joints of walls, ceilings etc. up to any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 29 | Supply / application of cement concrete of the foll. Proportions:- |
| 30 | (A) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor [Pakur Variety] in 1:3:6 proportions. |
| 31 | (B) Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. Pakur variety. |
| 32 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected up to three decimals). |
| 33 | Easing, oiling and adjusting the steel shutters including scraping all members and fitting so as to make the shutters easily operable ( no extra payment will be made for taking out and fixing glass, if necessary). |
| 34 | Renewing one point steel (oxidized) handle of steel door and windows as directed including painting complete. |
| 35 | 100 mm. thick brick work with Fly Ash Bricks set in cement sand mortar (1:4) including raking out joints, curing, scaffolding etc. complete in all respect. (a) In ground floor. Please Enable Macros to View BoQ information |