| 1 | SH : Development of site |
| 2 | Filling available excavated earth ( excluding rock) in trenches, plinth, sides of foundations etc.. In layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5 m. |
| 3 | SH :- T-II Quarter (Duplex) |
| 4 | SH : EARTH WORK |
| 5 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 6 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 7 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 8 | SH : CONCRETE WORK |
| 9 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 10 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone shingle 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 11 | Providing and laying damp proof course 25 mm thick with cement concrete 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm nominal size). |
| 12 | SH : RCC WORK |
| 13 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 14 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 15 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a)1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 16 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 17 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 18 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 19 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 20 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 21 | b) Column, pillars, posts and struts etc. |
| 22 | c) Lintels, beams, girders, bressumers and cantilevers etc. |
| 23 | d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 24 | Reinforcement of RCC work including bending, binding and placing in position complete. b) TMT steel |
| 25 | SH : BRICK WORK |
| 26 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
| 27 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 28 | Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level. |
| 29 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 30 | Extra for brick masonry in superstructure above plinth level up to floor two level. |
| 31 | SH : WOOD WORK |
| 32 | Providing approved best available local wood (Class - B II) work in frames of doors, window, clerestory windows and other frames, wrought framed and fixed in position. |
| 33 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. A) 38 mm thick best available local wood, class - B I |
| 34 | Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position. |
| 35 | Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size). |
| 36 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.(a) Plain grill |
| 37 | Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete. (c) Timber Class - BII |
| 38 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. |
| 39 | b) 250 x 16 mm |
| 40 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. |
| 41 | c) 150 x 10 mm |
| 42 | d) 100 x 10 mm |
| 43 | Providing and fixing aluminium handles anodised transparent or dyed to required color or shade with necessary screws etc complete. |
| 44 | a) 125 mm |
| 45 | b) 100 mm |
| 46 | Providing and fixing iron pressed butt hinges bright finished with necessary screws etc. complete. |
| 47 | c) 100 x 75 x 4 mm |
| 48 | f) 75 x 63 x 4 mm |
| 49 | Providing and fixing MS Hooks and Eyes. |
| 50 | e) 100 mm |
| 51 | SH : STEEL WORK |
| 52 | Providing and fixing MS round holding down bolts with nuts and washer plates etc complete. |
| 53 | Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete. |
| 54 | Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.(c) In Flats up to 10 mm in thickness |
| 55 | SH : FLOORING |
| 56 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. |
| 57 | a) 40 mm thick |
| 58 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 59 | SH : ROOFING |
| 60 | Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses. |
| 61 | b) 0.63 mm thick GI sheet |
| 62 | Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. |
| 63 | b) 0.63 mm thick GI sheet |
| 64 | SH : FINISHING |
| 65 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
| 66 | 15 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall. |
| 67 | White washing with lime on new work (two or more coats) to give an even shade. |
| 68 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade. |
| 69 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 70 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 71 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
| 72 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 73 | Painting two or more coats on GI sheets with ready mixed superior paint of approved brand and manufacture on new work to give an even shade. |
| 74 | SH : INTERNAL WATER SUPPLY |
| 75 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.a) Internal work - Exposed on wall |
| 76 | (i) 15 mm nominal outer dia Pipes |
| 77 | b) 20 mm nominal outer dia Pipes |
| 78 | Providing and fixing brass bib cock of approved quality. |
| 79 | a)15 mm nominal bore |
| 80 | SH : SANITARY INSTALLATION |
| 81 | Providing and fixing white vitreous china water closet squatting pan size 580 mm size. |
| 82 | a) Long pattern (Indian type) WC Pan |
| 83 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. |
| 84 | a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 85 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. |
| 86 | b) 250 x 125 x 25 mm |
| 87 | Providing and fixing kitchen sink including making all connection excluding cost of fittings. |
| 88 | a) White glazed fire clay sink size 600x450x150 mm |
| 89 | Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete. |
| 90 | Providing and fixing CP Brass Chain and rubber plug complete for sink or wash basins. |
| 91 | Providing and fixing CP brass waste for wash basins and sinks. |
| 92 | 32 mm dia |
| 93 | Providing and fixing MI fisher union for wash basin and sinks. |
| 94 | 32 mm dia |
| 95 | Providing and fixing CP Brass or MI trap for wash basin and sinks. |
| 96 | 32 mm dia |
| 97 | Providing and fixing in position 25 mm dia mosquito proof coupling of approved municipal design. |
| 98 | Providing and fixing on wall face asbestos cement soil, waste and vent pipes including jointing with spun yarn soaked in bitumen and cement mortar 1 : 2 (1 cement : 2 coarse sand) complete. (a) 100 mm dia |
| 99 | Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 100 | a) 100 x 100 x 100 mm |
| 101 | Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. |
| 102 | a) 100 mm inlet and 100 mm outlet |
| 103 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. |
| 104 | a) 100 mm dia |
| 105 | Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia |
| 106 | SH : DRAIN |
| 107 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 108 | Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. |
| 109 | a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 110 | Construction of soak pit 1.2 x 1.1 x 1.2 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design. |
| 111 | SH : MISCELLANEOUS |
| 112 | Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand). |
| 113 | 1.20 m high welded steel wire fencing with 1.80 m RCC posts of standard design placed at every 3 m apart embedded in cement concrete blocks 45 x 45 x 60 cm of mix 1:5:10 (1 cement : 5 fine sand : 10 stone aggregate 40 mm nominal size), corner end and every 10th post to be strutted and embedded in cement concrete blocks of 70 x 45 x 50 cm of same mix provided with welded steel wire fabric 0.90 m wide , rectangular mesh 75 x 25 mm size weighing not less than 7.75 kg per Sqm. fixed between the two posts fitted and fixed with GI staples on wooden plugs or tied to 6 mm bar nibs with binding wire including earth work in excavation, concrete work and cost of posts, struts etc. complete. |
| 114 | Providing and fixing steel gate with RCC Columns (size 3.00 X 1.50 mtr). |
| 115 | SH : Septic Tank |
| 116 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 117 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : (a) Foundations and plinth |
| 118 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand). |
| 119 | Reinforcement of RCC work including bending, binding and placing in position complete (b) Tar/TMT steel. |
| 120 | Providing, hoisting and fixing up to floor two level pre-cast reinforced cement concrete in vertical and horizontal fins individually or forming box louvers and bands including finishing and plastering with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm on exposed surface to give a smooth and even surface, centering and shuttering and shetting in position with cement mortar 1 : 2 (1 cement : 2 fine sand) etc but excluding cost of reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone shingle 20 mm nominal size). |
| 121 | 6 mm cement plaster to ceiling 1 : 3 (1 cement : 3 fine sand). |
| 122 | Neat cement punning. |
| 123 | 12 mm cement plaster 1:3 (1 cement : 3 fine sand). |
| 124 | Providing and fixing on wall face asbestos cement soil, waste and vent pipes including jointing with spun yarn soaked in bitumen and cement mortar 1 : 2 (1 cement : 2 coarse sand) complete. (a) 100 mm dia |
| 125 | Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.(a) 100 mm inlet and 100 mm outlet |
| 126 | SH: ELECTRICAL INSTALLATIONS (for 2 Units Ty-II Qtr.) |
| 127 | POINT WIRING |
| 128 | Copper point wiring in steel conduit : |
| 129 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 130 | Group A |
| 131 | Group B |
| 132 | Group C |
| 133 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 134 | 200 mm X 250 mm X 60 mm deep |
| 135 | 150 mm X 150 mm X 60 mm deep |
| 136 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 137 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 138 | 2 X 10 sq. mm + 1 X 10 sq. mm earth wire |
| 139 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 140 | 2 x 4 sq. mm |
| 141 | 2 x 6 sq. mm |
| 142 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 143 | ERECTION OF FITTINGS |
| 144 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 145 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 146 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 147 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 148 | CABLES, MAINS AND SUB-MAINS |
| 149 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 150 | Single pole and neutral |
| 151 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. |
| 152 | 32 amps TPN |
| 153 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 154 | 4 way (4 + 12), Single door |
| 155 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 156 | 200 Amp, 16 KA |
| 157 | SUPPLY OF LIGHTING FIXTURES & FANS ( mkt. Rates) |
| 158 | Supply the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. |
| 159 | 1 x 40 watts Flourescent Light Fixture as per Bajaj Cat No. BJIE 136/140 |
| 160 | Fancy bracket light fitting |
| 161 | 48 \\" dia ( 1200 mm sweep ) ceiling fan. |
| 162 | CLF Bulb |
| 163 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 164 | SH: Boundary Wall |
| 165 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. |
| 166 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: |
| 167 | a) Foundations and plinth |
| 168 | Centring and shuttering including strutting, propping etc and removal of form work for : |
| 169 | a) Foundation, footings, bases of columns etc. and mass concrete. |
| 170 | b Column, pillars, posts and struts etc. |
| 171 | c) Lintels, beams, girders, bressumers and cantilevers etc. |
| 172 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : |
| 173 | M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 174 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. |
| 175 | M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 176 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. |
| 177 | M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 178 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 179 | 1) Mild Steel |
| 180 | 2) Tar/TMT steel |
| 181 | Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand). |
| 182 | Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth. |
| 183 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
| 184 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 185 | 15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall. |
| 186 | Providing and laying up to floor two precast cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) including centring shuttering in : |
| 187 | i) String courses, copings, bed plates, anchor blocks, plain window sills and the like. |
| 188 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. A) plin Grill |
| 189 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. Please Enable Macros to View BoQ information |