| 1 | Earth work excavating and depositing on bank with initial lead of 10m and initial lift of 2m in hard stiff clay. Stiff black cotton soil, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders, as per standard specification, etc., complete. |
| 2 | Earth work excavating and depositing on bank with initial lead of 10m and initial llift of 2.0m in soft disintegrated rock, laterite, soft rock (or) kankar not requiring blasting, as per standard specification, etc., complete. |
| 3 | Earth work excavating and depositing on Bank with initial lead of 10m and initial lift of 2m in medium rock and dense medium rock not requiring blasting, as per standard specification, etc., complete. |
| 4 | Supplying and filling M sand (Approved quarry) well watered and consolidated in foundation and basement in layers complying with standard specification, including cost of all materials, all labour charges, lead, lift, T&Ps etc., complete as directed by the Engineer in charge. |
| 5 | Providing Plain Cement Concrete in 1:3:6, using OPC 53 grade cement (DALMIA/ ULTRATECH/RAMCO) ,M sand , 40mm HBG metal- (Approved quarry) including cost of cement, all materials, labour charges, curing, all leads, lifts, as per standard specification etc., complete as directed by the Engineer in charge. |
| 6 | Providing Reinforced cement concrete (RCC) 1:1.5:3 using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for matt foundation including cost of all materials, water charges, shuttering charges, labour lead, lift, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.) |
| 7 | Providing R.R.Masonry in C.M 1:5 for foundation including cost of all materials leads lifts labour charges etc complete. |
| 8 | Providing Reinforced cement concrete (RCC) 1:1.5:3 using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for plinth and grade beam including cost of all materials, water charges, shuttering charges, labour lead, lift, etc., complete as directed by the Engineer in charge. (But excluding cost of steel reinforcement.) |
| 9 | Refilling the foundation and basement with excavated earth other sand with all leads and lifts, watering, consolidation etc., complete as per standard specification and as per direction of the Engineer incharge. |
| 10 | Providing Anti termite pre construction treatment using emulsifiable concentrate of required percentage as suggested by the manufacture and specification as per 6313 part II - 1971 around Excavated Area, Plinth, Foundation and Basement in four stages as directed by the Engineer at Site including cost of all materials, lead,lift etc., complete. |
| 11 | Supplying and filling gravel and consolidating in 150mm thick layers, well rammed with all leads and lifts , watering, as per standard specification, etc., complete as per standard specification and as per direction of the Engineer incharge. |
| 12 | Brick work in CM 1:5 using IInd class chamber burnt bricks (230x110x75mm) ,OPC 53 grade cement (DALMIA/ULTRATECH/RAMCO),M sand for super structure and other structures including cost of all materials, scaffolding, labour charges, curing, lead, lift, T&P, etc., complete as directed by the Engineer in charge. |
| 13 | Providing Reinforced cement concrete (RCC) in 1:1 ½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for Column with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. (But excluding cost of steel reinforcement.) |
| 14 | Providing Reinforced cement concrete (RCC) in 1:1 ½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for continous lintel beam with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. (But excluding cost of steel reinforcement.) |
| 15 | Providing Reinforced cement concrete (RCC) in 1:1 ½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for sunshade with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. (But excluding cost of steel reinforcement.) |
| 16 | Providing Reinforced cement concrete (RCC) in 1:1 ½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for loft with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. (But excluding cost of steel reinforcement.) |
| 17 | Providing Reinforced cement concrete (RCC) in 1:1 ½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 12 to 20mm (machine crushed) metal (Approved quarry) for roof slab with centering shuttering form work including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. (But excluding cost of steel reinforcement.) |
| 18 | Providing Plain cement concrete (PCC) in 1:1 ½ :3 mix using OPC 53 grade cement (DALMIA/ULTRATECH/ RAMCO) ,M sand , 6 to 10mm (machine crushed) metal (Approved quarry) for granolithic concrete over roof top including cost of cement, all materials, labour, curing, vibration charges, with shuttering, all leads, lifts, as per standard specification, etc., complete. |
| 19 | Providing steel reinforcement for RCC works using Fe 550 TMT bars (TATA/SAIL/JSW/VIZAG) having for all RCC works including cutting, bending, binding, tying and placing in position including cost of steel, galvanized binding wire, lead, lift and etc., complete as directed by the Engineer in charge . |
| 20 | Plastering in CM 1:5, 12mm thick using OPC 53 grade cement (DALMIA/ ULTRATECH/RAMCO),P sand approved quarry for all wall surfaces,etc., including cost of all materials, scaffolding charges, Labour charges, curing, lead, lift, T&P etc., complete as directed by the Engineer in charge. |
| 21 | Plastering in CM 1:3, 12mm thick using OPC 53 grade cement (DALMIA/ ULTRATECH/RAMCO),P sand approved quarry for ceiling, beams, sunshade ,lofts etc.,including cost of cement, all materials,curing, labour, lead and lift etc., complete as directed by the Engineer in charge. |
| 22 | Colour washing with two coats using ready mixed Weather Proof Emulsion (First quality - Asian paint ultima or its equivalent) of approved quality over a coat of exterior emulsion water based primer in surfaces including clean removal of dirt, cost of all materials, scaffolding, labour, lead, lift etc.,complete as directed by the Engineer in charge. |
| 23 | Dadooding walls with approved quality of glazed tiles, size and design (Kajaria/Johnson or its equivalent), laid in cement mortar 1:2 -10mm thick including pointing with same coloured cement using 0.4kg/sqm, finishing the joint sand pointing flush with the tile surface , including cost of all materials, labour, lead, lift, etc. complete as directed by the Engineer in charge. |
| 24 | Providing floor finish with stain free nano polished Vitrified tiles of approved size, make(Kajaria/Johnson or its equivalent), colour and pattern over 10mm thick Cement mortar 1:3 for bedding and pointing same coloured cement in all floors , including cutting chase in walls wherever required, cost of all materials labour charges lead, lift, curing T&P etc., complete as directed by the Engineer in charge. |
| 25 | Flooring with available sizes of approved quality,design & colour (Johnson or equivalent make) of non-slippery anti skid tiles laid in cement mortar 1:3 -20mm thick including pointing with same coloured cement using 0.4kg/sqm, finishing the joints, including cost of all materials, labour, lead, lift, etc. complete as directed by the Engineer in charge. |
| 26 | Manufacturing supplying and fixing of Fully panelled double leaf steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x6mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter, 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 4nos. One the top of each shutter, one at lock rail and the other at the bottom are provided. 1no. Aldrop is provided at lock rail section in the door 3 Nos of handle are to be provided, one more aldrop is provided in the inner lock rail section of the door One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters. at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc.,complete complying with standard specification and as directed by the departmental officers |
| 27 | Fabricating Supplying and fixing in position of Aluminium anodised powder coated finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - Each., aluminium tower bolt 200x12mm - 1No., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete complying with standard specification and as directed by the Engineer incharge. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete. |
| 28 | Supplying and fixing PVC panelled door shutters hollow type with PVC frames including cost of necessary aluminium hinges and other furniture fittings, leads, lifts, labour charges etc, complete as per specification. |
| 29 | Supplying , fabricating and fixing in position Aluminium Anodised powder coated finish Three track sliding window in all floors with Aluminium sections of Outer Frame bottom [email protected] kg/m,Top & vertical 92.34x29.70x1.50 at 1.066 kg/m, Shutter vertical 39x20x1.50 at 0.493 kg/m,Top & Bottom 18x36.6x1.50 at 0.439 kg/m,Vertical locking arrangement 28.94x39x1.50at0.632 kg/m, the follwing sizes with necessary accessories such as rubber beadings, special hinges, lock, handle including supplying and fixing 4mm thick plain glass including cost of all materials , labours, power consumption required for fabrication , drilling holes in RCC colunm, slab, masonry walls wherever necessary with power drills to the required extent and make good to the original condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers.The aluminium sections are to be anodised with matt finish under electrically controlled in accordance with IS 1868 / 1962 for an average anodic film thickness 15 microns etc., complete. |
| 30 | Supplying, fabricating and fixing inposition Aluminium anodised natural colour matt finish louvered ventilator with outer frame section with 62x38x2mm at 1.174 kg/m and the louvered with moving arrangements made with aluminium channel of size 60x30x4mm @ 1.274 kg/m Aluminium clips 19.05x17.27/ 11.05x0.075mm @ 0.169kg/m with necessary 4mm thick plain glass panel for louvers including cost of all materials, labour and power required for fabrications, chipping dismantling making holes in RCC, masonry and made good to the original condition after fixing etc. complete complying with standard specification and as directed by the deparmental officers. The Aluminium surface is to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 for anodic film thickness of not less than 15 Microns,etc., complete. |
| 31 | Supplying and fixing of structural Steel for ladder and window grills including cost of all materials, fabrication charges, painting with two coats of enamel paint over one coat of primer, labour charges, lead, lift and making good of damaged portion etc complete |
| 32 | Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 33 | Supply and fixing of 2\\" x 2\\" GI Chain link fencing of 10 gauge with standard including cost of all material, labour for fixing, transportation, lead, lift etc., complete |
| 34 | Supply and fixing of galvanized barbed wire fencing of 10 gauge with two ply and four pronged including cost of all material, labour for fixing, transportion, lead, lift, etc., complete. |
| 35 | Supplying & fixing of cuddapah slab polished both sides for cup-Board, 20mm thick including all materials, lead, lift and fixing in position etc., complete. |
| 36 | Providing and fixing sanitary fitting consisting of Neycer / parryware of Oriya type Indian Water Closet 580mm x 440mm with P/S trap connecting with PVC ventilating shaft and Y bend complete, including cost of all material, labour, lead, lift, etc, complete as directed by the Engineer in charge. |
| 37 | Providing and fixing sanitary fitting consisting of Neycer / parryware of European Water Closet with \\"P\\" or \\"S\\" Trap with Double Flapped Seat and Seat Cover with Brass Hinges and 10 litre capacity PVC Low Level Flusing Tank with all internal fittings including cost of all material, labour, lead, lift, etc, complete as directed by the Engineer in charge. |
| 38 | Supplying and fixing of wash basin of size 550 x 400 mm of approved quality neycer / parrys ISI including cost of wash basin with pedastal cock fixing using rag bolt and nut 15mm dia pvc connecting hose and outlet using 50mm dia pvc waste water pipe for outlet cp angle valve with all accessories including cost of all materials, labour, lead, lift, etc., complete as directed by the Engineer in charge. |
| 39 | Providing PVC down fall pipe using 110mm dia 4 Kg / sqcm, PVC pipe and pvc clamp line supreme etc, including fixing PVC bend & shoe, in correct position and connecting from the roof slab including cost of all materials, labour, transport lead, lift,PVC accessories and washers etc., complete as directed by the Engineer in charge. |
| 40 | Supply and laying of PVC pipe 25mm dia of 10kgs/cm2 (FINOLEX/ ASTRAL/ SUPREME) approved make and quality with ISI monogram including cost of all materials, all specials such as Tees, Elbow, shoes, Special clamps, bends and screws, gratings etc., making holes in masonry/concrete, restoring the disturbed area to original condition, making water tight jointing with no leakage, labour, scaffolding, lead, lift etc., complete as directed by the Engineer in charge |
| 41 | Supply and laying of PVC pipe 40mm dia of 10kgs/cm2 (FINOLEX/ ASTRAL/ SUPREME) approved make and quality with ISI monogram including cost of all materials, all specials such as Tees, Elbow, shoes, Special clamps, bends and screws, gratings etc., making holes in masonry/concrete, restoring the disturbed area to original condition, making water tight jointing with no leakage, labour, scaffolding, lead, lift etc., complete as directed by the Engineer in charge |
| 42 | Supplying and fixing 25mm dia Heavy Gate valve (LEADER/ZOLOTO) of approved quality including cost of all materials, labour charges for fixing, lead, lift etc.,complete as directed by the Engineer in charge. |
| 43 | Supplying and fixing 40mm dia Heavy Gate valve (LEADER/ZOLOTO) of approved quality including cost of all materials, labour charges for fixing, lead, lift etc.,complete as directed by the Engineer in charge. |
| 44 | Supplying and Providing PVC 4 layer tank (SINTEX /ASHIRVAD/SUPREME) 1000Lit of approved quality and make including necessary inlet, outlet, over flow and drain line fixing accessories / fitting, cost of all materials, labour charges for fixing, lead, lift etc., complete as directed by the Engineer in charge. |
| 45 | Supplying and fixing 15mm PVC screw down tap heavy type including cost of pipe and labour fixing charges lead, lift, as per standard specification etc. complete |
| 46 | Supplying and fixing PVC ventilating shaft of 110 mm dia (having working pressure 4 kg /sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quallity etc., complete complying with standard specification and as directed by the department officers. |
| 47 | Supplying and laying PVC pipe 110 mm outer dia 6kg/ cm2 ISI make for laying the sewer line including cost of pvc pipe coupling labour for cutting, laying, fixing and tightening etc including earth work excavation and refilling trench etc., complete as directed by the Engineer in charge. |
| 48 | Supplying and fixing in position of CI man hole cover with CI frames (heavy duty) of size 60 cm x 60 Cm of best approved quality as per standard specification , etc., complying with standard specifications |
| 49 | Wiring with 3 x 2.5 sq.mm (36/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling for lights, fan and buzzers with PVC accessories in wall with heavy metal switch box and 5A modular switches with continuous earthing for providing 2.5 sq.mm multi stand PVC wire of PVC light point / fan point with 5amps switch ceiling rose, cable, pipe etc., complete |
| 50 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for concealed PVC plug point |
| 51 | Wiring with 2 x 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15A 3 pin non inter locking wall socket with 15A flush type switch with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour for concealed power plug point |
| 52 | Supply and fixing of 20W 4 Feet LED Fitting of Higher end (Philips/ Havells or equivalent make) as approved by the engineer incharge at site with round blocks on wall or ceiling with PVC unsheathed copper lead from terminals to the fittings including cost of all materials such as cables, pipes, etc., complete as directed by the Engineer in charge. |
| 53 | Supplying and fixing of 1200mm (48\\") sweap BLDC ceiling fan with 300mm down rod with appd best quality make of standard specification with electronic regulators and switch including cost of all materials, labour, fixing, charges as per standard specification, etc., complete. |
| 54 | Supplying and fixing of 30W LED street light fitting with LED with 25mm dia GI pipe (class B) with 1 no. 25mm GI bend complete on the existing post / on wall with PVC unsheathed copper leads with MSclamp with painting including cost of all materials, lead, lift, fixing charges etc., complete. ( philips/Crompton make ). |
| 55 | Supplying and fixing of 8 way single pole and neutral MCB sheet steel enclosure Distribution board with Double door ( Metal ) 1 No. 32 Amps DP MCB as incoming and 6 Nos. 6 Amps to 32 Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark |
| 56 | Earthing as per PWD standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32 mm complete with necessary masonry work including cost of all materials, lead, lift, fixing charges etc., complete.. |
| 57 | Supply and fixing of TNEB meter board suitable for 32A three phase service connection with 3 Nos. 32A fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 1 No 40 Amp 30 MA Four Pole RCD / RCCB with suitable necessary connection |
| 58 | Filling with 40 mm metal in dispersion trench including all materials, spreading, labour, lead, lift etc., complete. Please Enable Macros to View BoQ information |