| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | Providing and laying of stone soling, hand packed, including carriage of same from approved source upto site of work complete. |
| 3 | P/ L in position cement concrete in 1:4:8(1 cement :4 coarse sand : 8 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. |
| 4 | Reinforced cement concrete work in 1: 1.5 : 3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size)excluding the cost of centering, shuttering, finishing and reinforcement but including carriage of all materials from approved sources upto site of work complete.( All works upto plinth level) |
| 5 | Reinforced cement concrete work in 1: 1.5 : 3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size)excluding the cost of centering, shuttering, finishing and reinforcement but including carriage of all materials from approved sources upto site of work complete.( All works above plinth level upto level V) |
| 6 | P/ L in position cement concrete in 1:3:6(1 cement :3 coarse sand : 6 graded crushed stone aggregate, 20mm nominal size) excluding the cost of centering and shuttering but including carriage of all materials from approved sources up to site of work complete. |
| 7 | Reinforcement for RCC work including straightening cutting, bending, placing in position and binding all complete (Thermo mechanically treated bars) including all carriages complete. |
| 8 | Centering & shuttering including strutting, propping etc including removal of form work for Foundations,, footings, bases of columns etc. for mass concrete. |
| 9 | Centering & shuttering including strutting, propping etc including removal of form work for lintels, Suspended floors , edge of slabs |
| 10 | Brick work with F.P.S (non modular) bricks of class designation 75at all locations in 1:4 mix (1 cement: 4 coarse sand) including carriage of all materials from approved sources upto site of work complete. |
| 11 | Providing wood work in frames of doors windows, clerestory windows and other frames wrought framed and fixed in position with hold fasts lugs or with dash fasteners of required dia and length (hold fasts lugs or dash fasteners shall be paid for separately (imported K D wood) including all carriages complete. |
| 12 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with s of necessary screws, excluding panelling which will be paid for separately, all shutter complete as per direction of Engineer-in-charge. imported KD wood 30mm |
| 13 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick of imported KD wood. |
| 14 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 15 | 15 mm thick cement sand palasterin 1:6 including carriage up to site of work |
| 16 | 12 mm thick cement sand palasterin 1:4 including carriage up to site of work |
| 17 | Providing and fixing of glass panes 3.5 mm thick weight not less than 10kg/sqm with all necessary fittings and fixtures all complete |
| 18 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 20 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work. |
| 22 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 10.2.1 Riveted Welded |
| 23 | Providing and fixing of 0.5mm thick colour coated high rib iron profile sheets of approved profile as approved by Engineer-in-Charge in roofing including carriage of same upto site of work complete. The sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 mtr or as directed by Engineer-in-Charge. The sheet shall be fixed using self drilling /self tapping screws of size(5.5 x 55mm) with EPDM seal of same colour matching the shade of the sheets. |
| 24 | Providing ridges of hips of width 60 cm over all width colour coated fixed with Polymer Coated J or L hooks Bolts and nuts 8 mm dia GI Limpet and bitumen Washers Complete |
| 25 | Providing and fiixing aluminum Hard ware fiitings |
| 26 | L drop Link lock |
| 27 | Handles 6\\" |
| 28 | Handles 4\\" |
| 29 | Tower bolt 100mm |
| 30 | T bolt150mm |
| 31 | Hooks |
| 32 | P/F stainless steel (304) railing made of hollow tubes, channels, plates et. including welding griding buffing, polishing and making curvature whenever required) and fixing the same with stainless steel nuts and bolts compite incl. fixing the railing over SS Posts and three intermediate railings of 10mm dia and top railing 50mm dia with necessary accescries and stainless steeldesh fasteners, stainless steel bolts of requires size on the top of the floor or the side of the waste slab with suitablle arrangements as per approval of EIC |
| 33 | P/F stainless steel (304) King post with necessary accescries and stainless steeldesh fasteners, stainless steel bolts of requires size on the top of the floor or the side of the waste slab with suitablle arrangements as per approval of EIC |
| 34 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate |
| 35 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with: Black zebra marble 16mm thick |
| 36 | Providing and fixing of PVC Conduit ic junction boxes, bends etc 25mm all complete as per the directions of incharge engineer at site |
| 37 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 38 | Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/SSK/KEI/RR or equivalent make ) including the cost of conduit. |
| 39 | Providing and fixing of Heating point 4 mm PVC insulated copper wire of Polycab, Havels, Finolex, Khaitan make laid through PVC Conduit Pipe chanel of required size with 2.5 mm PVC Insulated copper wire of same make for earth wire 3 pin of heating with all filtings of approved make recesed / surface point duly tested and commissioned Complete |
| 40 | Providing and fixing of 10 Watt Led Ceiling Bulb ( Havells/Syska/Philips or Eqv sample to be approved by incharge incharge engineer at site ) |
| 41 | Providing and fixing of ceiling fan sweap width 18\\" ( Havells/Syska/Philips or Eqv sample to be approved by incharge incharge engineer at site ) |
| 42 | Providing & Fixing of wiring for 3-5 pin 6- Amp socket points in 2.5mmPVC insulated copper wire of Polycab/Havells/Finolex/Alba /Logus make laid through PVC conduit pipe/channel of size with fittings of approved make including 5-pin 6-Amp switch/socket of Philips/Reo havells/C.G/SSK topline make,point taken upto D.B duly tested & commissioning complete. |
| 43 | Providing and fixing of Exhaust fan sweap having Iron Blades 12\\" ( Havells/Syska/Philips or Eqv sample to be approved by incharge incharge engineer at site ) Please Enable Macros to View BoQ information |