Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors/walls and roofs laid in cement mortar including stacking material within 50 meters lead:- For thickness of tiles 10 mm to 25 mm. |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-inharge. 1:3:6 or icherr mix (i/c equivalent design mix) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:- 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 4 | 12mm Cement plaster finished with a floating coat of neat cement of mix: 1:4 ( 1 cement : 4 fine sand) |
| 5 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 6 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 7 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:- In cement mortar |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 9 | Hacking of wall plaster including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 10 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 11 | Removing dry or oil bound washable distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface even and smooth including necessary repairs to scratches upto required height complete job |
| 12 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick |
| 13 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work.(interior cum exterior) |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 15 | Painting metalic paint had a durable glossy finish, water-resistant and anti-corrosive properties including coat of under lying primer werevever required two or more coats (old work) |
| 16 | Providing and laying Vitrified tiles in floorsAnti-skid with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) conforming to IS: 15477, in average 6 mm thickness, including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), complete as per direction of Engineer-in-charge. Size of tile 600x600mm. |
| 17 | Providing and laying Vitrified tiles in walls with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), complete as per direction of Engineer-in-charge Size of tile 300x600 with 3mm spacers |
| 18 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour or shade (Jet Black) (Area of slab over 0.5 sqm) |
| 19 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :- imported KD wood 30mm thick |
| 20 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws imported KD wood 30mm thick |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws (30mm thick) |
| 22 | Providing and fixing wire Mesh for shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with necessary screws as per direction of Engineer-in-charge |
| 23 | Engagement of carpenter for easing out doors, windows, etc complete excluding cost of fixtures complete job. |
| 24 | Providing and fixing of imported wallpapers (Glass cloth or Fabric type) on walls/ceiling of approved quality like cassio, passion, polo or other including cost of fixing material and labour including preparing even surface to provide smooth texture of wall paper complete job confirming to IS 15418 (2003) design approved Engineer Incharge |
| 25 | Providing and fixing 3.5 mm thick glass panes of standard quality in glazed shutters including cost of beading complete job; all inclusive |
| 26 | Providing and fixing 19mm thick plyboard of approved quality and brand for cabinets/Almirah fixed in position complete job. (Item to be executed strictly as per the directions of EIC) |
| 27 | Providing and fixing of 10mm ply on backside cabients, of approved make and quality including cost of supply carriage etc complete job; all inclusive |
| 28 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position Budloo / Fir wood |
| 29 | Providing and fixing 0.8mm laminated dulmica/sunmica of approved brand and colour including fixed with approved adhesive properly complete job as directed by Engineer inchargel; all inclusive. |
| 30 | Providing/fixing of hardware fixtures of approved make including necessary screws etc. |
| 31 | Magnetic catchers |
| 32 | Handles (4\\") |
| 33 | Hydrualic Hinges |
| 34 | T-bolts 6\\" |
| 35 | Providing/fixing of in built locks of link lock or equivalent as per directions of Engineer incharge; all inclusive. |
| 36 | Draw channels 2' to 3' |
| 37 | 4'' Fancy handles for cabinets |
| 38 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets 25 mm dia (heavy type) |
| 39 | Dismantling aluminum / Gypsum partitions/ ply wood doors, windows, fixed glazing/ and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. |
| 40 | Providing and fixing 10 mm ply woodover over existing wooden planks floor/ceiling including necessary nails/screws etc, a coat of wooden primer and all carriage, as per the direction of Engineer-in-charge complete job; all inclusive |
| 41 | Providing and fixing of PVC ceiling 6 mm thick of standard Quality including aluminium/wooden framework, nails, screws and scaffolding. as directed by Engineer-in-charge complete job; all inclusive. |
| 42 | Providing & fixing PVC pipe heavy duty Type-B (prince, Finolex), Water or Vent pipe with cowl. And necessary bends , junctions, reducers, rubber washers , adhesives , complete job also including cost of all fittings and fixture like bends Tee's Collars Sockets Spigots ,reducers ,traps, washers, Earth work, Sand Cushion and Back Filling wherever required as per the direction of Engineers in charge. |
| 43 | 50mm dia pipe |
| 44 | 75mm dia pipe |
| 45 | 110mm dia pipe |
| 46 | 160mm dia pipe |
| 47 | Providing and fixing white vitrous wash basin with C.I. brackets, with pedestal including all necessary fitting and fixtures complete job. inclusive all as per direction of Engineer Incharge |
| 48 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid. |
| 49 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mm |
| 50 | Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings, fixtures, overflow arrangements with specials and mosquito proof coupling of approved municipal design complete 10 liter capacity -White |
| 51 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.-- PN-20 pipe , 25mm |
| 52 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.-- PN-20 pipe , 32mm |
| 53 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.-- PN-20 pipe , 40mm |
| 54 | Providing/fixing of C.P fittings of approved make as approved by EIC |
| 55 | Angle value |
| 56 | 2In 1 bibcock |
| 57 | Health facuet |
| 58 | Bib cock |
| 59 | Sink mixer |
| 60 | Basin mixer |
| 61 | Wall mixer |
| 62 | Waste pipes |
| 63 | Grating |
| 64 | Towel Ring |
| 65 | Soap case |
| 66 | Nipples 15 mm |
| 67 | CP Waste Coupling |
| 68 | Pop up waste coupling |
| 69 | Providing and fixing P.VC. connection pipe with brass unions-15 mm nominal bore- 45 to 60 cm length |
| 70 | Providing , installation, commissioning and testing Hot water Geyzer of approved make including fixing with bolts/ fasteners/PVC connection etc. Venus, Recold, Hindware, Havells, Jaquar, Crompton of required capacity fittings and fixtures all complete wherever required in the course of completion. complete job. |
| 71 | 35 liters |
| 72 | 50 liters |
| 73 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns) |
| 74 | Providing and fixing ACP 3mm multi coloured (Fire retardant) in partitions, ceilings, shutters frames etc including cost of rubber, neoprene gasket,taping, waterproof silicon sealent ,or as required at site as per the directions of concerned engineer in charge |
| 75 | Providing and fixing of Hardware fittings of approved make complete job |
| 76 | Hinges4\\" |
| 77 | Hinges3\\" |
| 78 | Handles(5\\") |
| 79 | Eye hook |
| 80 | Tower bolts 4\\" |
| 81 | Tower bolts 6\\" |
| 82 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete |
| 83 | Providing and fixing of 450x450mm UPVC manhole cover along with frame of specified size complete job . |
| 84 | Disposal of un-serviceable material including rubbish/vegetation outside municipal limits by means of mechanical transport including loading unloading complete; all inclusive as directed by Engineer Incharge. |
| 85 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 86 | Providing and fixing of 2mm polycarbonate plain coloured sheet of standard Make including all necessary fittings, self drilling /self tapping screws EPDM rubber bottom and top, including cutting to size, shape wherever required as per direction of Engineer-in-Charge, all lifts, leads and carriages complete job all inclusive. |
| 87 | Providing and fixing 15cm wide 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 88 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 89 | Providing and fixing of 10mm ply soffit including cost of underlying framework and scaffolding and a coat of wood primer complete job; all inclusive as directed by Engineer Incharge.\ |
| 90 | Providing and fixing plained eaves boarding. 2nd class kail wood 250x32 mm (nominal size ) |
| 91 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5 :3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 92 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 93 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 94 | Engagement of plumber for dismantling of various sanitary fitting / water storage tank and reinstalling the serviceable items complete job all inclusive. |
| 95 | Finishing walls with Acrylic smooth exterior paint of required shade Old work (one or more coats applied @ 0.90 liters/ 10sqm) |
| 96 | Carriage of Sand and Aggregates below 40mm nominal size for an average lead of 20Kms from source to site. |
| 97 | Carriage of bricks by mechanical transport including loading unloading leads from source to site of work. for an average lead of 25 Kms |
| 98 | Wiring for Light point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable (Havells/Polycab/Finolex Make) in existing surface/recessed Conduits (Excluding Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/ Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved not less than SDO. |
| 99 | Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved not less than SDO. |
| 100 | Wiring for Ceiling fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable (Havells/Polycab/Finolex Make) in surface/recessed Conduits(Excluding Cost of Conduit) with 01 No. of 6 Amp Modular Switch,, Modular Plate,Cover in front and suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand (Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/ Equivalent Make & shall be approved not less than SDO. |
| 101 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved not less than SDO. |
| 102 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Finolex/Paramount/KEI Make) |
| 103 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved not less than SDO. |
| 104 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Finolex Make) |
| 105 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand (Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved not less than SDO. |
| 106 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/Finolex/Equivalent Make) & shall be approved not less than SDO. |
| 107 | 4x2 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. |
| 108 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Sub main in One run from Main Panel to Distribution Boards. |
| 109 | 2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards. |
| 110 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved not less than SDO. |
| 111 | Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections. (L&T/Siemens/Legrand/ABB/Schneider Make) |
| 112 | Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider Make) |
| 113 | 32Amp. |
| 114 | 40Amp. |
| 115 | 63Amp. |
| 116 | Supplying and Fixing of MCB 8-Way horizontal typed , sheet steel, Double Door Distribution Board, SPN 240V V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider Make) |
| 117 | Supplying and Fixing of MCB 6-Way (4+18) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ABB/Schneider Make) |
| 118 | ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.(For Panel) |
| 119 | Supply/Installation/Testing and Commissioning of 15W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150/220V to 240V .The Fixture should have In-built Surge Protection of 2kV & 440V Protection,Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Polycab/Wipro /Jaguar/Trilux/LT/Equivalent Make & shall be approved not less than SDO. |
| 120 | Supply/Installation/Testing and Commissioning of 18W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150/220V to 240V .The Fixture should have In-built Surge Protection of 2kV & 440V Protection,Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab.The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Polycab/Wipro /Jaguar/Trilux/LT/Equivalent Make & shall be approved not less than SDO. |
| 121 | Supply/Installation/Testing and Commissioning of 6-10 Watt. LED Bed Light Light fitting with Aluminium Body of Philips/HG/Bajaj/ Wipro/Jaguar Make including making of necessary connections including cost of Ceiling Rose,Silken wire also with round plates Etc complete. |
| 122 | Supply/Installation/Testing & Commissioning of 10W LED Mirror Light of Philips/Bajaj/Jupiter/Jaguar/ Equivalent Make as duly fitted on walls including making of necessary Connections & sample shall be approved. |
| 123 | Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability /authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/ accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Crompton/Wipro/Jaquar/Polycab Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning /handing over of site to intending department. |
| 124 | Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Halonix/Polycab/Orient/Equivalent Make.(5-Star) & shall be approved not less than SDO. |
| 125 | Supply/Installation/Testing and Commissioning of 200-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient Make. |
| 126 | Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified. |
| 127 | Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark (IS:15683) suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires. |
| 128 | Supply/Laying of 25/32mm Dia PVC Conduit/ Channel/Wooden Channel of Anchor/Ravinder/ Polypack/Finolex/Equivalent Make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Tile with same Colour/Paint etc. |
| 129 | Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes. |
| 130 | Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc. |
| 131 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.Havells/ Legrand/Panasonic/Anchor/Schneider Make |
| 132 | Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall / floor mounted) compartmentalized , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices(For Three Storey Building-A)Normal Incoming:-200 Amp TPN MCCB with extended thimbles of Legrand/Siemens/ABB//LK make = 1 no 200 Amp TPN Bus bar Copper Strips = 1 Set, Voltmeter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1setOutgoing:-(1) 63 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 08 No for normal heating sub main(2) 40 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 08 No for Sub main lighting/ACThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing |
| 133 | Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall / floor mounted) compartmentalized , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices(For Double Storey Building-B & D)Normal Incoming:-160 Amp TPN MCCB with extended thimbles of Legrand/Siemens/ABB//LK make = 1 no 200 Amp TPN Bus bar Copper Strips = 1 Set, Voltmeter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1setOutgoing:-(1) 63 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 06 No for normal heating sub main(2) 40 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 06 No for Sub main lighting/ACThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing |
| 134 | Supply/ installation/testing and commissioning of CPRI Approved (IS/IEC:61439) panel Wall / floor mounted) compartmentalized , 415 volts TPN MCCB Mian Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices(For Double Storey Building-C & E)Normal Incoming:-100 Amp TPN MCCB with extended thimbles of Legrand/Siemens/ABB//LK make = 1 no 100 Amp TPN Bus bar Copper Strips = 1 Set, Voltmeter =1 no, Ammeter = 1 no , CT coils for Am meter 300 /5A = 1 set ,phase indicators =1setOutgoing:-(1) 63 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 02 No for normal heating sub main(2) 40 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder /L&T make = 02 No for Sub main lighting/ACThe Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to approved by Engineer Incharge before manufacturing |
| 135 | Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make. |
| 136 | Supply/Laying/Connecting and Commissioning of 50 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of KEI/Polycab/RR Kabel/Paramount Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench |
| 137 | Supply and Fixing of Modular 25-32Amp industrial Socket outlet having fitted with 25-32 Amps SP MCB and Top with Modular Plate,Cover in front & suitable GI box etc for AC Points |
| 138 | Supply and Fixing of 16 Amp Top of Legrand/Panasonic/ Anchor/ Schneider/ Equivalent Make for i/p-o/p Inverter ckt |
| 139 | Dismantling of existing wires in scraps,switches,sockets,fixtures,fans etc for 11 Blocks,Including and handing over the same to conerned authorities. Please Enable Macros to View BoQ information |