| 1 | Providing,Loading , Unloading ,Carriage , Installation ,Testing and Commissioning of 400 KVA 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Pre Ammendment ( Cu wound ) with OCTC (Off Ckt Tap Changer), and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. |
| 2 | Providing,Fixing ,Testing and Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 3 | Providing,Fixing ,Testing and Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type along with earthing of operating handle ( including lugs/thimbles --all accessories) |
| 4 | Providing,Fixing ,Testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 5 | Providing,Laying ,Testing and Commissioning of 400 mm² 1.1kV Grade,unarmoured XLPE Insulated Stranded Conductor FRLS type |
| 6 | Providing ,Loading , Unloading ,Carriage , Installation ,Testing and Commissioning of 9 Long Pole alongwith earthing channel piece (ST-410 SP33) . |
| 7 | Providing,fabrication,Fixing of GI Channel/Angle/Flat of sizes including clamps for sub station (as per approved Drawings) |
| 8 | Providing,Fixing of Galvinized Nuts and Bolts. |
| 9 | Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. (as per approved Drawings) |
| 10 | Providing,Fixing ,Testing and Commissioning of 11 kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 11 | Providing,Fixing ,Testing and Commissioning of LT Distribution Box for:- 400 kVA DTR with a)630 Amp MCCB 3P 36 kA adjustable 1 No for incomer &b) 400 Amp MCCB 3P 35 kA adjustable typer 1 NoC)200 Amp MCCB 2 No fixed type for Outgoing Circuits . Including link disconnectors,d)32 Amp SP MCB ( as per drawing) |
| 12 | Providing of Painting of Poles with two coats of Red Oxide and two coats of Aluminium Paint per pole |
| 13 | Providing , Fabrication, fixing of pole post of MS Pipe Post 10 feet long and 6 inch diawith proper size end Plates for support to Bed Structure including earthing, mproper Paint ( Redoxide/ aluminum /tractor orange ) and cement bottoming of 0.25 Cum / pole post |
| 14 | Providing,Fixing of 11 kv Danger Plates with Clamps |
| 15 | Providing,Fixing of Anti Climbing devices using GI Barbed Wire with end clamps (2 Kg Barbed wire per job/pole with 2 GI Clamps with GI Nuts and bolts with washers ) |
| 16 | Providing of Cement bottoming of 9 mtr ST pole using 1:2:4 mix as per Standards 0.48um /pole |
| 17 | Providing, Fixing aluminium lugs of 400/300 mm sq size |
| 18 | Providing ,Loading , Unloading ,Carriage , Installation ,Testing and Commissioning of 8 Mtr. Long Pole alongwith earthing channel piece (ST-410 SP15) |
| 19 | Providing,Laying ,Testing and Commissioning of 300 mm² 1.1kV Grade,unarmoured XLPE Insulated Stranded Conductor FRLS type |
| 20 | Providing,Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting set of 3 Nos |
| 21 | Providing of Earthing of 9mtr and 8 mtr ST poles complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm |
| 22 | Providing of Cement bottoming of 8 mtr ST pole using 1:2:4 mix as per Standards 0.40cum /pole |
| 23 | Providing , fixing / laying of conductor 30 mm sq ACSR for tapping of HT line / Jumpers |
| 24 | Providing , fixing / laying of conductor 50 mm sq ACSR for LT Network connections/ Modification. |
| 25 | Providing , fixing of GI Muki Clamps fibricated out of 50x8 mm galvinized flat (0.75 Kg per Muki) having end inner dia 18 mm for Shackle insulatuo suitable for ST Pole with back clamp and galvinized nuts and bolt |
| 26 | Providing , fixing of 16 KN Polymer LT Shackle insutor |
| 27 | Straightening of existing tilted LT poles including its cement bottoming of using 1:2:4 mix as per Standards 0.30 cum /pole |
| 28 | Dismantelling of existing LT wooden/ST pole |
| 29 | Providing , installation testing & commissioning of 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No G.I channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door. (for 11 KV HT METERING CT AND PT OPERATED) |
| 30 | Providing , installation testing & commissioning of A) set of three numbers ,Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5. The CT ratio shall be 15/5 B) 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute. (for 11 KV HT METERING CT AND PT OPERATED) |
| 31 | Providing , installation testing & commissioning of Bus Bar CTs bus bar:- 40x6 mm copper strip or adequate size ,PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape . PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm² (RYB) and for PT wiring minimum wire size shall be 2.5 mm² (RYB). Copper Lugs preferably ring type duly crimped for termination of wires and tapes Grounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. The CTs, PT meter and 11kV Cable sheath shall be grounded to the bus through grounding wire (green) of min size 10mm² (for 11 KV HT METERING CT AND PT OPERATED) |
| 32 | Providing , installation testing & commissioning of BIDIRECTIONAL 3Ph 3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energy meter DLMS Compliant Category 'C' with RS 232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) meters for measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc .Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HT compartment to meter compartmentPedestal made out of G.I Channel of size 75 x 40 mm or angle iron of size (65 x 65 x 5) mm, duly painted as per site requirement for mounting of metering panel including concrete foundation wherever required including cost of nuts and bolts (for 11 KV HT METERING CT AND PT OPERATED) |
| 33 | Providing , installation testing & commissioning of 3 Core 11 kV Aluminium cable XLPE armoured 35 mm² including cost of clamp for its fixing where ever required. |
| 34 | Providing , installation testing & commissioning of Cable termination kits suitable for 3 x 35 mm² XLPE Cable (Indoor/Outdoor) (for 11 KV HT METERING CT AND PT OPERATED) |
| 35 | Providing , installation testing & commissioning of Earthing by way of 40 mm 2.5 mtr long GI Pipe. Job includes , excavation, enhancement material and Main Hole Chamber (500x450x600)mm with frame and cover. (for 11 KV HT METERING CT AND PT OPERATED) |
| 36 | Providing , installation of LT line Spacers of appropiate size and configration |
| 37 | Providing , installation of Wedge connectors/ PG clamps |
| 38 | Providing and submission of both Pre and Post work execution Geo-tagged coloured photographs of the subjected work on A4 size glazed photo paper ( 2 pics per page ) pre and post |
| 39 | Providing and fixing of fluorescent sign board of appropiate size ( 4'X3') showing details of the work like name of the Department, Name of the work,Head of account, Date of Start ,Date of Commissioning,and any othe relivant details as rwquired ,fixed over GI Angle of appropiate size and Specification. Please Enable Macros to View BoQ information |