| 1 | Removing existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime cova etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush complete all as specified and directed. |
| 2 | M&L of water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100mm micron HMHDPE outer film 20 micron each having thickness 3mm weight not less than 3kg/Sqm as per manufacturer’s instructions with torch applicationcomplete all as specified and directed by Engineer-in-Charge with following course of description below:-(a) 10 mm thick plaster in CM 1:4 with WPC will be applied over the roof slab when concrete is green. After the plaster is cured the roof will be tested for water tightness by ponding with water for seven days for any seepage is observed the rectification will be carried out by pressure grouting under the pressure of 5kg/sqcm using cement based cement grout. After the surface is repaireds the slab will be tested for water tightness again before proceeding with further treatment. (b) the surface of roof, parapet and gutters, drain mouths, etc. over which waterproofing treatment is to be applied shall be cleaned of all foreign matter such as, fungus, moss, dust etc by wire brushing and dusting. For cast iron drain out lets a grove shall be cut around to tuck in the treatment. Concrete angle-fillets shall be provided at junctions between roofs and vertical faces of walls (parapet and other walls) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners.(c) Bitumious based primer confiorming to IS: 3384 @ 0.3 kg/SM to be applied on prepared surface, till the surface is property. impregnated. (d) After the application of approved bituminous primer the water proofing membrane shall be laid on the primed surface by torch application method as per manufacturer's instruction. The overlap while toching shall be 100mm in longitudinal direction and 100 mm in transverse direction. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer and seling it with the help of hot trowel. The overlap joints shall be made as a monolithic layer.(e) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane. |
| 3 | M&L for water proofing treatment for roof by applying priming coat of epoxy primer with resin and hardner in 1:3 ratio with water dilution as per manufacturer instructions, applying 2 coats of solvent based Polyurethane liquid applied membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 kg/sqm (each coat), 2nd coat should be applied once 1st coat becomes dry completely all as specified and directed.Make: Asian Paints, Berger or equivalent Note:(i) The work under this item shall be carried out by the authorized applicator of Manufacturer by using modern techniques. The contractor shall also furnish warranty of quality, finish work and effectiveness of waterproofing treatment under this item for a periof of 10 years from the date of completion along with manufacturer warranty of material for the same period. (II) Height of bldg is more than 10 meters and roof have continous series of trapizium with no staircase to reach at the top of the building |
| 4 | M&L for Apply a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance, complete all as specified and directed |
| 5 | M&L for Cement concrete tiles 25cm x 25cm x 20mm thick, machine pressed; set jointed with grey cement and no pigment and pointed in neat cement slurry in floors, and cut and polished, complete all as specified and directed. |
| 6 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in padding levelling and similar work etc roof kerbs. |
| 7 | M&L for 10 mm thick rendering in CM (1:4) mixed with water proofing compound @ 0.20 Ltr/bags on roof surface/ vertical wall surface of sunken, when concrete is green, complete all as specified and directed. Note:- liquid WPC will be paid separately. |
| 8 | Supply only liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as specified and directed. Make : Dr Fixit LW |
| 9 | M&L for water proofing treatment for roof by applying priming coat of epoxy primer with resin and hardner in 1:3 ratio with water dilution as per manufacturer instructions, applying 2 coats of solvent based Polyurethane liquid applied membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 kg/sqm (each coat), 2nd coat should be applied once 1st coat becomes dry completely all as specified and directed.Make: Asian Paints, Berger or equivalent Note:(i) The work under this item shall be carried out by the authorized applicator of Manufacturer by using modern techniques. The contractor shall also furnish warranty of quality, finish work and effectiveness of waterproofing treatment under this item for a periof of 10 years from the date of completion along with manufacturer warranty of material for the same period. (II) Height of bldg is more than 10 meters and roof have continous series of trapizium with no staircase to reach at the top of the building |
| 10 | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. |
| 11 | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered WHITE COLOUR 1000 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. |
| 12 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting, reconnecting and re-fixing in position of exc. 250 litres & not exc. 500 litres capacity of tanks,Date of cleaning of tank will be marked on the tank by stencil with synthetic enamaled paint in uniform size, Size of letters & numbers should be 40mm. complete all as specified and directed. |
| 13 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting, reconnecting and re-fixing in position of exc 500 and n. exc1000ltr capacity of tanks, Date of cleaning of tank will be marked on the tank by stencil with synthetic enamaled paint in uniform size, Size of letters & numbers should be 40mm. complete all as specified and directed. |
| 14 | S&F in repairs of 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 15 | S&F in repairs of 15 mm dia of Brass Ball valves high with flynut complete screwed for iron pipe or brass ferrel. |
| 16 | S&F in repairs of 20 mm dia of Brass Ball valves high with flynut complete screwed for iron pipe or brass ferrel. |
| 17 | S&F in replacement of 15 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed. |
| 18 | S&F in replacement of 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed. |
| 19 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick AZ 150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified incl dismantling Asbestos Cement Corrugated or Semi corrugate in Roof covering |
| 20 | M&L for pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed incl dismantling Asbestos Cement Corrugated or Semi corrugate in Roof covering |
| 21 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts in roofs, walls etc, complete all as specified and directed incl dismantling Asbestos Cement Corrugated or Semi corrugate in Roof covering |
| 22 | Dismantling timber scantling 40 Sqcm and over in section in any position as in unframed works such as roof purlins, rafters, fillets ,ridges etc as in ceiling complete all as specified and directed. |
| 23 | M&L mild steel (Fe 410W, Gde 250) work as roof trusses (framed) trussed, purlins, crane gantries ,rails and fastenings and heavy brackets framing (beams, tee, angle, channels or flat sections) etc complete all as specified and directed . |
| 24 | S&F of exposed frame false ceiling system with GI powder coated grid consisting of interlocking arrangement of main T runner of 15mm size, suspended at 1200mm C/C and cross T runner of 15mm size suspended at 600mm C/C supported by 1.5 mm dia GI wire from roof/Slab/truss including wall/perimeter runner/channel of 15 mm size with and including 4mm thick pre-painted non asbestos fiber reinforced cement board (E-board), designer type of size 595x595mm duly fixed in ceiling frame work complete all as specified and directed incl dismantling of old wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including snap grid frame work |
| 25 | M&L for application/forming of waterproofing liquid membrane moistening the prepared surface for proper dispersion and penetration and applying two component cementitious elastomeric water proofing coating damp block 2k as per manufacturers specifications. The treatment shall be carried out to the entire bottom surface and vertical surface upto the bottom height of wall tiles. Adequate curing to be done on vertical surfaces and ponding test for 48 hours on the bottom surface to be carried out complete all as specified and directed. Make :- M/s Asian paint, M/s Berger, M/s forsoc, M/s Sikka, M/s BISNOTE :(a) Treatment shall be done through authorised applicator/representative of the manufacturer only.(b) Warranty for water proofing to be submitted by the contractor as per manufacturer norms |
| 26 | M&L PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in mass filling sunken portion etc and complete all as spd and directed incl demolition of cement concrete of any description and in any position |
| 27 | M&L 50mm dia G.I pipe as in spout to drain out if any leakage occures in the sunken portion complete all as spd |
| 28 | S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling, 32 mm PVC Waste pipe 600mm long complete all as specified and directed. |
| 29 | Supply & Fix in repairs Vitreous China Squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rests. |
| 30 | Supply & Fix in repairs Vitreous China wash down water closet pan (pedestal pattern), EWC, coloured including jet system & matching coloured seat covered fixed complete all as specified. |
| 31 | Supply and Fix in repairs 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, low level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long and PVC 32 mm dia flush pipe. |
| 32 | S & F 15 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors, concealed or open incl cutting of grooves all as specified and directed incl taking up or down old one steel tubing and connections including fittings. |
| 33 | S & F 20 mm bore Galvanized Steel tubes, medium grade fixed to walls and ceilings or laid in floors, concealed or open incl cutting of grooves all as specified and directed |
| 34 | M&L for non skid ceramic color tiles of size 300x300mm, 7 to 8 mm thick (square / rectangular) as in flooring etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed/ bedding layer in CM (1:6) incl dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed. |
| 35 | M&L for ceramic colour tiles in vertical surface of size 450 X 300 x 7 mm thick, jointless type, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with and including 10 mm thick rendering in CM (1:4) for receiving the tiles, incl dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and directed. |
| 36 | Taking down cement plaster on brick or stone wall including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 37 | M&L for brick work subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in built in cm (1:6), complete incl demolition of brick work built in cement mortar or lime mortar including all quoins arches, pillars etc complete all as specified and directed |
| 38 | M&L for rendering 10mm thick in CM(1:6) on fair faces of brick work/concrete surfaces, finished even & smooth (without using extra cement), complete all as specified and directed. |
| 39 | M&L for 15 mm thick rendering in CM (1:4) on other than fair faces of brick work or concrete surfaces, finished even and smoth without using extre cement complete all as specified and directed. |
| 40 | M&L for preparation of new plastered surface and of wall and applying two coats of oil bound distemper, over and including a layer of wall care putty to get even and smooth level finish on new plastered surface of internal wall, complete all as specified and as directed. |
| 41 | M&L for preparation of new surface of wall by bruss , sand paper, surface replacement if required etc on surface and applying two coat of cement based paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 42 | S&F of PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors,incl taking down of eaves gutter and rain / waste water pipes including all fittings any size and pattern,complete all as directed. |
| 43 | S&F of PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors,,incl taking down of eaves gutter and rain / waste water pipes including all fittings any size and pattern,complete all as directed. |
| 44 | S&F 110 mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 45 | S&F 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 46 | S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed. |
| 47 | S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed. |
| 48 | S&F PVC (SWR) floor trap of 75 mm outlet, jointing to waste pipe, complete all as specified and directed. |
| 49 | S&F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement, complete all as specified and directed. Please Enable Macros to View BoQ information |