| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed. |
| 2 | Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed. |
| 3 | Refixing shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each in same opening, complete all as specified and directed. |
| 4 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises, complete all as specified and directed. |
| 5 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness, below or above ground level, complete all as specified and as directed. |
| 6 | Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for, complete all as specified and as directed. |
| 7 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for( reinforcement cut as required to facilitate demolition) and rubbish off the premises, complete all as specified and directed. |
| 8 | Demolition of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 9 | Dismantling of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 10 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed. |
| 11 | Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 12 | Taking up or down steel tubing 20mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 13 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed |
| 14 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed. |
| 15 | Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 16 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 17 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 18 | PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 19 | Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in cover slab for MH / septic tank etc, set in CM 1:4 including necessary form work, complete all as specified and directed. Note :- Reinforcement shall be measured and paid seperately under respective items. |
| 20 | RCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork, complete all as specified and directed. |
| 21 | Brick work with fly ash (Old Size bricks) sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed. |
| 22 | Brick work with old unserviceable bricks retrieved from dismantling straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:4, complete all as specified and as directed. |
| 23 | Brick work with fly ash bricks (Old Size bricks), sub class'B' bricks straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4, complete all as specified and directed. |
| 24 | 5mm thick rendering on concrete surface of ceiling, chajjas, soffits of slabs etc. in CM 1:3 finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 25 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 26 | 15mm thick rendering on brick work or concrete surfaces in CM 1:4 mixed with water proofing compound to sunken portion with proper slope towards outside, finishing cement concrete or brick work surface even and smooth using extra cement, provide 90 micron polythene film duly applying bitumen coating @ 3.00 Kg/Sqm complete all as specified and directed. Note: WPC shall measured and paid for separately. |
| 27 | 15mm thick rendering cement plaster in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid for separately. |
| 28 | 20mm thick cement plaster in cement mortar 1:4 on concrete surfaces, finished even and smooth using WPC liquid as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement, complete all as specified & directed. |
| 29 | 10mm thick rendering on fascia / edging / ceiling of Chajjas, roof projections etc, making the edges in line, in true shape in CM 1:3 and finishing the surface without using extra cement, complete all as specified and directed. |
| 30 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 31 | Preparation of surfaces and applying first coat of fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 300%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shåll resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry, applying second of undiluted coat @ 0.45 Itr/sqm. Applying third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacturer or authorised applicator, complete all as specified and directed. |
| 32 | Liquid membrane water proofing treatment over existing RCC roof slab / chajjah / canopy / parapet walls etc to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and directed :-(a) Cleaning of dust, removal for all loose existing bituminous material manually with heat torch gun to get smooth plain finished surface, removing of vegetation/plantaion with no loose material on surface and treating the crakes upto 3mm width with single pack fibre glass reinforced crack filling compound of SMART CARE CRACK SEAL (ASIAN PAINTS) or equivalent as approved. (b) Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplastic having penetration upto 8mm levelling of surface to give proper slope (after setting) with roof repair mortar i.e. cold applied Bituminous Mortar & cold emulsion cum waterproofing liquid, Created SSD condition on surface with water, prime the surface with liquid membrane waterproofing elastomeric monolithic acrylic emulsified water based bituminous coating with 200% elongation mixed with potable water in the ration of 1:1 and apply @400gm per Sqm (As per Surface Conditions)(c) Apply first coat of Liquid Membrane Waterproofing Elastomeric Monolithic Acrylic Emulshified Water based Bituminous Coating having elongation 200% conforming to ASTM-C-412, having cracks bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.50 mm conforming to ASTM-C-412 with no diluation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm, laying of Geotex of 45 GSM/ Fiber mesh simultaneously and paste it properly with overlap of 50mm & allow the first coat to dry for 10 to 12 Hrs . Please Enable Macros to View BoQ information |
| 33 | Liquid membrane water proofing treatment over existing RCC roof slab / chajjah / canopy / parapet walls etc to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and directed :-(a) Cleaning of dust, removal for all loose existing bituminous material manually with heat torch gun to get smooth plain finished surface, removing of vegetation/plantaion with no loose material on surface and treating the crakes upto 3mm width with single pack fibre glass reinforced crack filling compound of SMART CARE CRACK SEAL (ASIAN PAINTS) or equivalent as approved. (b) Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplastic having penetration upto 8mm levelling of surface to give proper slope (after setting) with roof repair mortar i.e. cold applied Bituminous Mortar & cold emulsion cum waterproofing liquid, Created SSD condition on surface with water, prime the surface with liquid membrane waterproofing elastomeric monolithic acrylic emulsified water based bituminous coating with 200% elongation mixed with potable water in the ration of 1:1 and apply @400gm per Sqm (As per Surface Conditions)(c) Apply first coat of Liquid Membrane Waterproofing Elastomeric Monolithic Acrylic Emulshified Water based Bituminous Coating having elongation 200% conforming to ASTM-C-412, having cracks bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.50 mm conforming to ASTM-C-412 with no diluation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm, laying of Geotex of 45 GSM/ Fiber mesh simultaneously and paste it properly with overlap of 50mm & allow the first coat to dry for 10 to 12 Hrs . Please Enable Macros to View BoQ information |