| 1 | Electrical wiring |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 4 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 5 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 6 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 7 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 8 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 9 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 10 | 1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet |
| 11 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 12 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 13 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 14 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 16 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 17 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 18 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 19 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 20 | OD329813/2025-2026:supplying and fixing 20A DP modular switch on the existing modular box for the control of AC units |
| 21 | OD329820/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 20 amp socket outlet |
| 22 | 90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid |
| 23 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid |
| 24 | Electrical panel/DBs |
| 25 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 26 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 27 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 28 | OD327510/2025-2026:Supplying and fixing of following ways surface/recess mounting vertical type,415 V Three phase, Energy meter box making material Poly carbonate (sintex Box) or metal (ABB, Indo asian or equivalent as per the PWD Approvals), vision panel, dust protected, box, common neutral link , 100 A FN main switch, 100 A porcelein fuse sets (3 Nos), etc complete (Provision for 3 phase energy meter of KSEB is included in the box). |
| 29 | OD329872/2025-2026:Supplying,fixing and testing of 10 kA, 4 pole 63 A MCB. |
| 30 | 90.11.1.12:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) |
| 31 | OD330009/2025-2026:Fabrication, supply, conveyance, installation testing and commissioning floor /wall mounting,dust and vermin proof, cubicle type panel board comprising of the following components/devices ,complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosurefor panel assembly using 1. 6 mm POWDER COATED CRCA sheet as per approved designand requirement 1. 6 mm for frame , with front access facility, bus bar chambers withAluminum bus bar , hinged doors for all switch gear compartments and earthing the doorsusing braided copper conductor and providing indication lamps, digital type Multi functionmeter, danger notice board, LED indicator, feeder compartment lock, terminalblock, PVC trunking, slotted channel, suitable connector, termination lug, copper wire ifrequired, meter viewing glass if required etc. The board should be powder coating theassembly after subjecting to 7 tank process as required. 2 Nos earth bar at the rear . earth stud.Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. InsulatedAluminium bus bar for phase and Neutral adequate ampere size of Incomer Switch , out goingswitches. if the panel is floor mount then the panel Board should be fitted on the base frame forpanel board using channels of class designation 75 including cutting,welding, drillingholes,painting two coats of synthetic enamel paint over a coat of zinc chromate paint botling theframe to the panel and to the furnished floor using required bolts and nuts making good thedamages colour washing and including providing and fixing the following switch gears etc asrequired. The charges for all control wiring, loading and unloading, testing and commissioningare included. The cable entry may be bottom or top as per direction of Engineer in charge, ThePanel shall be Fabricated as per Electrical Inspectorate, KSEB, & other relevent codes andstandards. MSB Panel : Supply, fabrication, erection, testing and commissioning of dust andvermin proof cubicle type powder coated 3 phase Panel board fabricated with 1.6 mm thickCRCA sheet, Including indication Lamps,Aluminium Bus bar of Capacity 160 A,Control wiringetc.. as required. INCOMER : 100 A ,10 kA, 415 V, 4 Pole MCCB Microprocessor release -1Nos ,ROM ,spreaders at the incoming side 160 A 4 pole Automatic Transfer Switch switch -1 Nos LED indicaction-2 sets , MFM Meter-2 sets For KSEB and D G set etc.complete. DIN Rail SurgeProtection Device (4+0) Class B+C/ Type 1+2 Tested as per IEC 61643 Part 11:2016 . TotalImpulse current-50 KA (10/350? sec) & Total Max Discharge current 200 KA (8/20? sec),Voltage protection level <1.5 kV . The Surge Protection Devices should have TOV safe fail for120 Min : 442 V and with out Follow Current & Leakage Current. Protective Elements are HighEnergy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating(Isccr) ? 25 kA/50 kA . Back up fuse required more than 315 AgG/gL. Health Status Indicationrequired in all cartridge. Total Response time <25 nano sec ELR with CBCT and Shunt Trip-1nos for generator side OUT GOING, 3 no.s -63 A, 4 Pole MCB, 3 Nos -40 A, 4 Pole MCB. |
| 32 | 2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 33 | OD334352/2025-2026:Supplying and fixing following rating four pole ,415 Volts, 40 A MCB in the existing MCB DB complete with connections testing and commissioning. |
| 34 | 90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 35 | cables and terminations |
| 36 | OD327470/2025-2026:Supplying,laying, commissioning and testing of 2C *16 mmsq aluminium cale for taking connection from post to the meter board in the building |
| 37 | 90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 38 | 90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm |
| 39 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 40 | 9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 41 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 42 | 90.16.1.5:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) |
| 43 | 90.16.1.6:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) |
| 44 | Electrical Fixtures |
| 45 | OD327532/2025-2026:Supply and fixing of 20W LED tube with all fittings.Make: Philips or other equivalent brands approved by Engineer in charge. |
| 46 | OD327534/2025-2026:Supply, conveyance, installation,testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/.2 mm PVC insulated and PVC sheathed 650/1100 V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200 mm sweep-1 star rated ceiling fan complete with 300 mm down rod,canopies,shackles and blades working on 230 V/240 V single phase AC. |
| 47 | OD327535/2025-2026:Supply and fixing of 250 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230 V single phase A/C. |
| 48 | OD327537/2025-2026:Supplying and fixing of LED bulb on existing batten holder. PWD approved brands |
| 49 | OD327538/2025-2026:Providing and fixing circular/ Hexagonal GI box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet with its top surface hacked for proper bonding, top lid shall be screwed into the GI box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be made of (8 or 12 )mm dia M.S. bar bent |
| 50 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 51 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 52 | OD327540/2025-2026:Supply, installation,testing and commissioning of 2 kg Dry chemical powder type (DCP) fire extinguishers having ISI mark along with mounting supports etc |
| 53 | OD327541/2025-2026:Supply and fix labels for panels switches,cables etc as specified |
| 54 | OD327542/2025-2026:Supplying & fixing of laminated schematic drawing |
| 55 | OD327556/2025-2026:Supply & fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd.(approximate front area 1.20 sq. metre) |
| 56 | OD327557/2025-2026:Supply and fixing CO2 type fire extinguisher conforming to IS 2876 with cylinderduly charged of capacity 4.5 kgs including fixing clamps brackets, bolts and nutsetc. asrequired. |
| 57 | OD327558/2025-2026:Supply and fixing of 2X1 mtr Electrical grade rubber mat conforming to IS 5424/2019, 12mm thickness forthe Electrical rooms |
| 58 | OD329843/2025-2026:Supplying, fixing and testing of 6 inch exhaust fans with all accessories. Specifications: Impeller diameter-15 cm,Rated voltage- 220-240 V, Rated frequency-50 Hz, Power 40 W,Capacity-780 m3/h, Speed-2800 rpm, Noise-56 dB. Make: Any PWD approved brand. |
| 59 | OD329849/2025-2026:Supplying,fixing and testing of Wall mounted fan. Specification: 400 mm sweep, air delivery :92 m3/min,speed 1320 rpm, voltage :230 V, warranty : 2 years. Make : Any PWD approved brands. |
| 60 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 61 | OD330820/2025-2026:Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by Engineer in charge. 25*3 Cu strips tinned at the point of contact |
| 62 | OD381336/2025-2026:Supplying,fixing and testing of Automatic voltage stabilizer for 1.5 Ton Split type Air Conditioner. Specifications:Product ISI Marked YESRated KVA (in KVA) : 5. Input voltage range Single Phase Sine wave (90V-300V).Output voltage range : Single Phase sine wave (200V - 240V). Material of winding : AluminiumWarranty period (in Months) : 12. Make: PWD approved brands |
| 63 | OD381337/2025-2026:Supplying, fixing and testing of Automatic Line Voltage Stabilizer for 2 Ton Split type AC. Specification:Product ISI Marked : YES. Rated KVA (in KVA) : 5. Input voltage range : Single Phase Sine wave (90V-300V). Output voltage range : Single Phase sine wave (210V - 250V). Material of winding : Aluminium .Warranty period (in Months) : 12 |
| 64 | OD381338/2025-2026:Supplying, fixing and commissioning of 1.5 Ton Split type AC. Specifications: Nominal Marketing Capacity As Per BEE Star Rating. (Hint: 1 Ton = 3000 K cal::Hr, Tolerance +::- 10%) (In Ton). Technology Of Air Conditioner Inverter AC. Variable speed. Unit Mounting Arrangement. Indoor Unit - Wall Mount Type. Rated Voltage (In Volts) 230 V, 1 Phase, 50 Hz, AC. Availability Of BIS::ISI Mark Certification. Material Of Evaporator Copper 12 Material Of Condenser Copper. Digital temperature Display. Air Purification and 4 way swing air flow direction. Make: PWD approved brand as per the direction of Engineer in Charge. |
| 65 | OD381339/2025-2026:Supplying, fixing and commissioning of 2 Ton split type AC. Specifications:Cooling capacity: 2 TR Class (24000 BTU/hr +/- 10%). Type of compressor: Rotary. Refrigerant: R32 or equivalent with GWP not more than 675. BEE Star rating: 5 (As per prevailing BEE star rating on date of procurement). Control: Wireless battery operated remote having LCD/LED display and provision for control of fan speed (minimum 3 speeds), temperature, swing, sleep mode with ON/OFF timer etc.Air filtration: PM 2.5 or better Demountable washable dust filter (preferably with add-on filters like Ion/Carbon/UV etc.).Power Supply: 230V, 50 Hz, single phase. Vendor should supply suitable rating external voltage stabilizer even if the AC is capable of operating with wide voltage range etc...Make: PWD approved any brands as directed by Engineer in Charge. |
| 66 | OD381490/2025-2026:Supplying, fixing and commissioning of 1 Ton Split type AC. Specifications:Nominal Marketing Capacity As Per BEE Star Rating Label (Hint: 1 Ton = 3000Kcal::Hr, Tolerance +::- 10%) (In Ton). Technology Of Air Conditioner -Inverter AC.Variable speed. Unit Mounting ArrangementIndoor Unit - Wall Mount Type. Rated Voltage (In Volts) 230 V, 1 Phase, 50 Hz,AC.Availability Of BIS::ISI Mark Certification. Material Of Evaporator Copper 12Material Of Condenser Copper. Make: PWD approved brand as per the direction ofEngineer in Charge. |
| 67 | OD381605/2025-2026:Supplying,fixing and testing of Automatic voltage stabilizer for 1 Ton Split type Air. Conditioner. Specifications:Product ISI Marked :YES. Rated KVA (in KVA) : 5. Input voltage range Single Phase Sine wave (90V-300V). Output voltage range : Single Phase sine wave (200V - 240V). Material of winding :Aluminium. Warranty period (in Months) : 12. Make: PWD approved brands |
| 68 | OD381964/2025-2026:Supplying,fixing and testing of indication light (red in colour) with all fittings. Make: any PWD approved brand. Please Enable Macros to View BoQ information |