| 1 | Earth work in excavation by mechanical means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: Ordinary Rock |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 3 | Providing and laying stone soling / boulders hand packed including compacting, watering including all carriages of material complete. |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 7 | Centring and shuttering including strutting proping and removal of form work for foundations, footings, bases of columns etc for mass concrete. |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand). Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 9 | Back filling with 2nd class sand/ stone dust/boulders inside plinth including watering, ramming rolling etc including all carriages and costs complete job. |
| 10 | Providing and fixing of wood work in frames of door/ window /arch windows /ventilator wrought frames (chowkats) imported Wood |
| 11 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts. |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain indow sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with :1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 15 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Suspended floors, roofs, landings, balconies and access platforms. |
| 17 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 18 | Providing High Rib. sheet 0.5 mm thick roofing including vertical/curved surfacefixed with polymer coated J or L hooks, bolts and nuts 8mm diameter withbitumen and G.I limpet washers or with G.I. limpet washers filled ithwhite lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch inhorizontal/vertical or curved surface) excluding the cost of purlins, raftersand trusses and ncluding cutting to size and shape wherever required |
| 19 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 20 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 21 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 22 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm |
| 23 | Providing and fixing glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. 35mm thick imported kail wood |
| 24 | Providing and fixing of Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type 25 mm to 40mm thick. for door shutters. |
| 25 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 27 | Providing and fixing of hardware items of good quality including cost of screws all complete job |
| 28 | Handles 150 mm |
| 29 | Handles100mm |
| 30 | T bolt 100mm |
| 31 | T bolt 150mm |
| 32 | Concealed locks 200 mm |
| 33 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 34 | Providing and fixing heavy duty glass panes 3.5 mm thick instead of ordinary glass panes 13.75 kg/sqm in doors windows and clererstoy windows shutters (Area of opening for glass panes excluding portion inside shall be measured |
| 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm. |
| 36 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 37 | Labou for site clearence by way of dismentling of dys functional toilet block job and dispose off all material as directed |
| 38 | Carriage of material by M T from source to site complete |
| 39 | Stone Aggregates Av. Lead 20 Kms |
| 40 | Sand Av. Lead 40 Kms |
| 41 | Bricks av. lead 20 kms |
| 42 | Electrification |
| 43 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab /Finolex /RR Kabels /Anchor /Salzer make in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and allied accessories like bends .lighting conceal deeps and fan deeps etc ) , with 6Amps modular switch, modular plate of Anti backteria series of Schneider /ABB /L&T /Legrand /Simens make , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( P+N+E ) for Normal and invertor points per room is to be provided seperately). The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit Complete as required Complete Job . The Job further includes providing and fixing of heavy duty Metallic conceled deeps and Fan junction deeps of standard make dully isi marked (to be approved by EIC before installation) actual numbers to be provided as per site requirement and as per instructions of EIC complete job |
| 44 | Point wiring for 10 Amp Socket out lets with 3x2.5 sq mm (P+N+E) FRLs PVC insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires of Polycab/Finolex/Anchor/RR Cabels /Salzer make, to be laid in recessed or surface conducting system (25 mm dia medium class PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and its allied accessories ,seperate conduit for each point ).The Job further Includes supply and fixing modular grid plate mounted flush mounted 2 no 240 volts 6-10 Amp 5 pin socket out let along with 2 No's of 6-10 Amp control Switch to be housed in 6-Way heavy duty GI Modular Box with modular cover plate of Anti fungal & Anti Bacterial of ABB /L&T / legrend /Simens make , complete as per specification and as required . The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit Complete as required Complete Job including conduits ,Switches ,Sockets and complete circuit from DB Box to switch-socket ( Seperate circuit for indiual points with out any looping and jointing ) |
| 45 | Point wiring for 16 Amp Socket out lets with 3x4 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/Finolex/Anchor/RR Cabels /Salzer make, to be laid in recessed or surface conducting system (25 mm dia medium class PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job including cost of conduits and its allied accessories ,seperate conduit for each point ) .The job further includes the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of Anti fungal & Anti Bacterial of ABB /L&T / legrend /Simens make to be housed in heavy duty 4-Modular GI Box of same make as of switches /sockets with p/f of modular cover plate , complete as per specification and as required with inter connection complete as per specifications and as required. The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit Complete as required Complete Job including conduits ,Switches ,Sockets and complete circuit from DB Box toto switch-socket ( Seperate circuit for indiual points with out any looping and jointing ) |
| 46 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits for housing of upto 4 Sq.mm wires and 32 mm dia for housing of above 4 Sq.mm wires including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job ,seperate conduit for each point ) as required. of Polycab / Finolex /Anchor / RR Kabels /Salzer make. |
| 47 | 2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire |
| 48 | 2 X4 sq. mm + 1 X4 sq. mm earth wire |
| 49 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 50 | 2 X 16 sq. mm +1 X 6 sq. mm earth wire |
| 51 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 52 | Supply and fixing of Indicators (Modular type) fitted on modular grid plate and GI Boxes complete job |
| 53 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/\N) minimum 6.00,Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (ma><.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required.of Usha / Crompton Greaves / Orient /Helonix |
| 54 | Supply ,installation ,Testing and Commissioning of 18 Watts ,Surface mounted (round type) LED Downlighter having aluminium Body (Commercial type) of Philips / Lighting techology / Trilux /wipro /Endo / Zumtobel / Ligman /Helonix make dully isi marked ,incl ceiling rose and 2-core transparent wire for connections complete job.The luminaire should have Back lit techanology and not side lit and should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit initial system lumen output of 1400 lumens with minimum system efficacy of 120 lumen/watt. The luminaire shall comply to lifetime of 50000Hrs @ L70B50 with design ambient temp 45°C. The electronic driver used shall have a power factor ≥0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, THD≤10%, Current Ripple ≤5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I. The luminaire should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. . The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Approved make (to be approved before installation) The Agency / firm has to submit Techanical data sheet (TDS) along with above mentioned requisite certificates before supply of materials for approval from department not less than |
| 55 | Supply ,Installation ,Testing and Commissioning of IP66 , 50 Watt LED Flood light Luminaries (Commercial type) having Aluminium body of of standard make dully isi marked ,to be fitted on walls / poles with necessary cliffs /Clamps with nuts and bolts complete job.The system efficacy of the luminaire shall be ≥130lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V (±15V). The luminaire shall have 10KV SPD in-built inside the luminaire. The maximum dimensions of the luminaire shall be, L: 264M, Depth: 52MM & height without cradle: 203MM. The nominal weight of the luminaire shall be maximum 2.4KGs. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material for approval. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. Approved make Philips / Lighting techology / Trilux /wipro /Endo / Zumtobel / Ligman (to be approved before installation) The Agency / firm has to submit Techanical data sheet (TDS) along with above mentioned requisite certificates before supply of materials for approval from department not less than rank of SDO. |
| 56 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.4 way (4 + 12), Double door Separate for Heating and lighting |
| 57 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens make |
| 58 | Supplying and fixing of 32-40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make |
| 59 | Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections |
| 60 | Supply,Laying,Testing & Commissioning of 50 sq.mm 2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/Polycab /Grandlays /KEI make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections |
| 61 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job |
| 62 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 63 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 125 Amp DP MCB (10KA) of Legrend /Schinder /Simens / ABB make = 1 no (1B) 200 Amp PN Aluminium Bus bar = 1 Set One No. (1 No.) digital multifunctional meter 1 Set of phase indication lamps (2) Generator Incomer 63 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no100 Amp PN Aluminium Bus bar = 1 Set One No. (1 No.) digital multifunctional meter 1 Set of phase indication lamps (3) Invertor Incommer 63 Amps DP MCB (10KA) of Legrend /Schinder /Simens / ABB make =1 No.100 Amp PN Bus bar Al Strips = 1 Set((4) Outgoing .63 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 3 No40 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 3 No 32 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make =3 No The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 64 | Supply,Installation,Testing & Commissioning of 2KVA Power Inverter ( 24 Volts) Sine wave type of make (Sukam / Luminous / Exide / Micro tec/Liv guard make ).The invertor shall have inbuilt display unit showing input and output voltage ,Charging voltage , output current etc with having inbuilt protection device of suitable capacity . The invertor should invertor and UPS mode of operation . The job further includes Supply , Installation , Testing & Commissioning of 2 No's of 180 AH /12 V Tall tubular Inverter Batteries of same make as of inverter ,the batteries are to be housed in angle iron Stand incl cost of pvc trolley . complete job.The job includes AMC of batteries and invertor for a period of three years ,which includes quarterly servicing of devices & as and when required. complete job. |
| 65 | Supply and fixing of 4 KVA relay type automatic voltage stabilizer (wall mounted ) operating from input voltage of 90-260 Volts thereby producing output voltage of 230 volts with inbuilt time delay of Chinar /Liv guard / Alba / IFB make Please Enable Macros to View BoQ information |