| 1 | Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /HPL /KEI/Polycab Conduit Make - ISI Marked Anchor/High Power /AKG/Equivalent make of required specification to be approved by the Engineer In charge (Group ‘A’) |
| 2 | Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/KEI/Plaza/polycab Equivalent make of required specification to be approved by the Engineer In charge )i. 2x1.5 +1x1.5 Sq mm |
| 3 | i. 2x2.5+ 1x2.5 Sq mm |
| 4 | iv. 4x6 +2x6 Sq mm |
| 5 | v. 4x10 +2x6 Sq mm |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG/) Equivalent make of required specification to be approved by the Engineer In charge 25 mm dia |
| 7 | Supplying and fixing 5 Amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. i. Single pole (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 8 | Supply and Fixing following ratings, four pole, 415 volts, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as reqd. 63 Amp ratings (Make Havells /Anchor/ C&S/HPL/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 9 | b.63 Amp 240 volt Double Pole Isolator. |
| 10 | Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100mm x 100mm x 60mm deep |
| 11 | 200mm x 125mm x 60mm deep |
| 12 | Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /HPL/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 13 | Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL/ Anchor/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 14 | Supply & fixing 5/6 amp piano type switch on the existing switch box or cover including connection as required (Make :Havells/ HPL / Anchor /Great White/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 15 | Supply & fixing 3 pin 5/6 amp socket outlet on the existing switch box or cover including connection as required(Make: Havells/ HPL / Anchor /Great white/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 16 | Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL / Anchor /SSK/ C&S/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 17 | Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / C&S/Great White/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 18 | Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 19 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 20 | Supplying and fixing following ways horizontal type three pole , and Neutral, sheet steel MCB Distribution Board 415V on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. i.8 way(4+24), Double door Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge |
| 21 | Providing and fixing following rating and breaking capacity MCCB with Thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL/I.A/ Equivalent make of required specification to be approved by the Engineer In charge) 100 AMP 16K TP MCCB |
| 22 | 400 AMP 35K TP MCCB |
| 23 | Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T Equivalent make of required specification to be approved by the Engineer In charge)1 run of cable |
| 24 | Re-wiring for light point/fan point/call bell point exhaust fan point with 1.5 Sqm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Wire Make ISI Marked Havells/Anchor/KEI/Polycab ) (Conduit Make - ISI Marked Anchor/High Power /AKG) Group ‘A’ |
| 25 | Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required (Wire Make ISI Marked Havells/HPL/Anchor/KEI/Polycab/ Equivalent make of required specification to be approved by the Engineer In charge) a. i.1x1.5 sqmm |
| 26 | ii.3x1.5 sqmm |
| 27 | iii. 3x2.5 sqmm |
| 28 | v.2x6 sqmm |
| 29 | Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/ Syska/Bajaj/ Greatwhite/ Philips/HPL/ Equivalent make of required specification to be approved by the Engineer In charge)a. 18 to 22watt, 220volts, 50Hz, 1200mm with rated input 140V to 270V,lumen efficiency 100 lumens/watt,driver efficiency 90%,starting voltage 90v,Thd<20,CRT>80, CT6500K,Life 25000 hours,surge 2.5 KV,P.F=0.9,made of high grade polycarbonate body LED batten complete. |
| 30 | 2 feet 9 to 12 watt ,230 volts LED batten type tube light fitting complete |
| 31 | 20 to 24 Watt LED recessed/surface mounting 6500 K, 240 Volts Slim Panel down light fittings/luminaries round (225x225)mm to (300x300)mm Dimensions. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) |
| 32 | 2X2 Recess Led Panel 595X595mm 36W +/- 1W Recess mounted fixture with minimum system efficiency of 100lm/W and minimum 3800 lumens, P.f is 0.9 with THD 10% CRI 80 the Led with life of 50000hrs.the LEDs used in the luminaries shall have CCT of 5700K to 6500K with CRI of minimum 80 Protection of 3kV. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) |
| 33 | Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient .(Make: Havells /Anchor /Crompton/USHA Equivalent make of required specification to be approved by the Engineer In charge) |
| 34 | Supply, installation, testing, commissioning of heavy duty 300 mm sweep BEE 3 to 5 star rated energy efficient exhaust fan.Make: ( Anchor/Havells/Bajaj/Crompton/ Equivalent make of required specification to be approved by the Engineer In charge) |
| 35 | Supply & installation of CAT 6 2 module toll less information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required.(Make Legrand/Delton/Havells/HPL/Anchor) |
| 36 | Supplying and fixing following ways horizontal type MCB Board 230V on surface/in recess complete interconnections including powder painted etc. as required (But without MCB/SPN.) i.4 way Encloser (Make :-Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge ) |
| 37 | Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge) |
| 38 | Supply, laying, testing and commissioning of PVC sheathed Aluminum conductor 1100 volts graded PVC AA round Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, including P/F of G.I saddles on walls/ceiling complete job. (Make: Havells / General/Polycab / Gloster Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable |
| 39 | 3 ½ core 25 sq mm armoured cable |
| 40 | 3 ½ core 120 sq mm armoured cable |
| 41 | Supply and fixing of (75X75)mm press fit type PVC Trunking for drawing the electric wires/Cables. |
| 42 | Supply and fixing of 100Amp onload I-O-II Four pole with advanced neutral on load change over switch confirms to IS 13947 (Part-3) IEC:609473) (Make I.A/Havells/HPL/Crompton Equivalent make of required specification to be approved by the Engineer In charge) |
| 43 | Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel Out door type floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/insulated conductors/strips etc. The panel shall be fabricated out of CRCA not less than 2.00 mm thick for the load bearing members and 1.6mm for doors of L.T Panels. The frame work may be Agle Iron/Channel/ Bolted type construction should be arrangement for I/C/O/G. Cable termination with 2 Each. 20x5mm cu. Strip fixed all around the panel connected to 2 Each. earth bars cu-strips connected to incoming earth conductor. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Gyatri/Hindustan/KED) Dimension 4'0\\"X4'0\\"X1'0' a. INCOMING Space for 1 No. 400 Amp TPN Al. Bus bar of equal cross section for Main Power connection to Main MCCB. a. Space for 1 No.400Amp 4 pole MCCBb. INDICATING PANEL The indicating panel of the incomer shall be provided with the following:i. Ammeter of required range with ASS, CT's.ii.Voltmeter of required range with VSS.c. OUTGOINGSpace for 1 No. 400 Amp TPN Al. Bus bar of equal cross section for power load/light load.Space for 5 No. 100 4 pole MCCB Space for 100Amp. changeover Switch Please Enable Macros to View BoQ information |