| 1 | GENERAL SUMMARY ( PHASE-I)NOTE: Schedule ‘A’ Part - I to XI are prepriced by MES under Ser No. 2.00 to 10.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-7 only. |
| 2 | Lumpsum price worked out by the contractor for “BUILDINGS / STRUCTURES ” as listed in Schedule ‘A’ Part - I , |
| 3 | Lumpsum price worked out by the tenderer for \\"SITE CLEARANCE / SITE DEVELOPMENT/ EARTH WORK/ EXCAVATION\\" as listed in Schedule ‘A’ Part-II |
| 4 | Lumpsum price worked out by the tenderer for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III |
| 5 | Lumpsum price worked out by the tenderer for \\"INTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-IV |
| 6 | Lumpsum price worked out by the tenderer for \\"ROAD/PATH/HARD STANDING/CULVERT \\" as listed in Schedule ‘A’ Part-V |
| 7 | Lumpsum price worked out by the tenderer for \\"SEWAGE DISPOSAL \\" as listed in Schedule ‘A’ Part-VI |
| 8 | Lumpsum price worked out by the tenderer for \\"EXTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-VII |
| 9 | Lumpsum price worked out by the tenderer for \\" EXTERNAL ELECTRIFICATION \\" as listed in Schedule ‘A’ Part-VIII |
| 10 | Lumpsum price worked out by the tenderer for \\" TV/TELEPHONE \\" as listed in Schedule ‘A’ Part-IX |
| 11 | SCHEDULE \\"A\\" PART - XMISCELLANEOUS ITEMSNOTE: Schedule ‘A’ Part - X is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-7. |
| 12 | M & L for sub main wiring (concealed) complete with two single core 10 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 10 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed.Note: Three runs of 10 sqmm cable and one run of 25 mm dia conduit shall be measured as one unit length. |
| 13 | M & L for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Make of cable : Polycab, Finolex,Havells Note: 3 run of 4 sqmm & one run 20 Sqmm of PVC conduit shall be measured as single unit length |
| 14 | M & L for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 19/20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed. |
| 15 | (a) One light point controlled by one switch |
| 16 | (b) One fan point controlled by one switch |
| 17 | (c) One exhaust fan point controlled by one switch. |
| 18 | (d) One switch socket outlet modular type 3 pin 6 amp on same board. |
| 19 | All as per item No 14 above but 1.5 sq mm cable size and 1.5 sq mm earth continuity wire for one 3 pin socket outlet, 6 amps on Independent board complete all as specified and as directed |
| 20 | All as per item No 14 above but 2.5 sq mm cable size with 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board complete all as specified and as directed |
| 21 | S & F for Modular Metal flush box,8 Module complete all as specified and as directed |
| 22 | Supply & Fixing in replacement bldg security light luminaires including 25 watt LED street light for 220-230 V, 50 Hz with IP 65 protection including bracket for fixing in wall, made of 25mm bore light grade GI Pipe connecting up with three core twisted flexible copper conductor cable complete all as specified and directed. |
| 23 | Supply and fix LED Bulb 9W Standard B-22 LED Bulb with 945 luminous flux complete all as specified and directed. |
| 24 | Supply and fix Power unit for 1.5/2 ton A.C including 25A MCB protected Heavy Duty with 16A plug connecting electric connections, complete all as specified and as directed. |
| 25 | M & L for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 4 mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part 1 connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 15 mm GI pipe (Medium grade) for protection of earth wire and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable complete all as specified and as directed by the Engineer-in-Charge. |
| 26 | Supply and fix Tele sockets of suitable type complete all as specified and directed . |
| 27 | Supply and installation LT Electric control feeder piller box, cubical type, for Out door use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 50mmx50mmx5mm with front open able shutters for each MCCB with spreader with fully enclosed bus bar chamber, having insulated bas bar made but of aluminium strips of rating 100 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of minimum height 45 cm from ground level to the platform all as specified and equipped with the following items.INCOMER (i) MCCB, 4pole, 63 Amps , rupturing capacity 25 KA magnetic thermal release - 01 Nos.II. Digital multi meter - 01 No III. LED Indicator lamp in three colour RYB - 03 NosIV. 3 Phase enery meter CT Operated LCD display - 01 No OUT GOING(I) MCCB, 4pole, 40Amps, rupuring capacity 10 KA magnetic thermsl release - 2 Nos (II) MCB SPN 2 pole 16 Amps rupuring capacity 16 KA magnetic thermsl release 2 Nos |
| 28 | Supply and fix energy saving LED street light fittings, 45 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED 5700K including all accessories complete all as specified and as directed. |
| 29 | Supply and fix bracket for LED street light fittings of Single Arm 1meter Bracket of 1Mtr long all as specified and as directed. |
| 30 | Supply and fixing in replacement of thermoplastic cable junction boxes IP 66 \\"halogen free and weather proof\\" for outdoor Installation with metric knockout for cable entry of size139 x119x70mm fixing on PCC block and glands suitable for 10 Sq mm 02 core cable all as specified and directed. |
| 31 | M & L for earthing complete with GI earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6 mm galvanised iron strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part 1 (2010 edition) connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable complete all as specified and as directed by the Engineer-in-Charge. Note:-(i) The rates quoted is inclusive of 32x6mm galvanised iron strip earth conductor upto a length of 7.5m from the earth pit. SIGNATURE OF CONTRACTOR Please Enable Macros to View BoQ information |