| 1 | Dismantling of Stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and as directed. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including removal of debries to Outside MD Land , complete all as specified and as directed. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for .including removal of debries to Outside MD Land , complete all as specified and as directed. |
| 4 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 5 | Dismantling cast iron/ PVC drain or vent pipe of any description in any position including bends branch pieces etc. complete all as specified and as directed. |
| 6 | Taking down cement plaster from walls /ceilings built in cement mortar, etc. including raking out joints, hacking for key, scrubbing down with water, etc. to receive plaster. including removal of debries to Outside MD Land , complete all as specified and as directed |
| 7 | Taking down chowkats or frames with shutters exc 1.5 sqm but n.exc 4 sqm each (without taking off shutters from the frame) complete all as directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 9 | Taking down existing tar felt, water proofing membrane etc of any description, any type including loose plastering / screed , padding concrete etc if any and removing all loose particles with wire brushes, removing bitumen coating over original RCC slab by grinding, picking, , grinding of mother concrete slab to make surface smooth suitable for applying PU waterproofing coat as per manufacturer's instructions, including removal of debries to Outside MD Land , complete all as specified and as directed. |
| 10 | Preparation of surfaces by sweeping cleaning and washing down with water to remove dust and loose particles over RCC slab for providing roof treatment, removal of unserviceable debris to outside MD land, and applying bitumen primer @0.30kg/sqm providing and laying 4mm thick APP modified water proofing membrane weight not less than 4.0 kg/sqm reinforced with non woven polyster mat weight not less than 160gm/sqm having softening point not less than 140 Degree centigrade longitudinal tensile strength not less than 520N per 5cm tearing strength of 180N (by torch application method) with minimum of 100mm side lap and 150mm end laps by application of torch. Applying a coat blown grade hot bitumen 85/25 under and over the membrane @ 1.20kg/sqm in each layer and applying 2 coats over and above membarine of silar reflective bitumenous aluminium paint @ 0.1Kg/sqm all as specified and as per manufacturr's instructions. The membrane shall be inserted in to the wall /parapet wherever required. mouth of rainwater pipes, gutters shall be properly treated to avoid ingress of the water. Note: (i) The rate quoted by the contractor shall be included for dismantling and refixing of PVC water tanks hoisted on roof, taking down and refixing of water tubing and any other fittings on roof as required and no extra shall be paid.(ii) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company guarantee to be given by contractor after completion of water proofing work before payment complete all as specified and as directed |
| 11 | \\"ROOF TREATMENT FOR ACCESSIBLE ROOF :M&L for Roof treatment for accessible roof as under: -(i) Preparation of surfaces by sweeping cleaning and washing down with water to remove dust and loose particles over RCC slab for providing roof treatment.(ii) Apply polyurethane waterproofing coating on prepared concrete surface of roof slab & up to 300 mm of parapets and crumple joint including junction of roof and parapet. Any minor cracks in the screed should be sealed with grouting and crack filling material or epoxy sealant filler. This stage shall be passed by the GE.(iii) Method: Cleaning the surface and applying FOSROC Nitoproof 650PU over a priming coat of FOSROC Nitoproof WB Primer or equivalent product of Asian paints , M/s M C Bauchemic / CIPY/ SIKA / Pidilite / Dr Fixit / Thermax / STP applied as per manufacturer’s instructions.(iv) Ponding test for 72 hrs to be carried out and no leakage / seepage shall be ensured. Any rectification to be done at the cost of contractor repeating above steps of application to the entire satisfaction of Engineer-in-Charge. (v) Further provide a polypropylene / polester , nonwoven geotextile fabric of 150 gsm followed by cement screed 15mm in CM (1:4) in slope and Machine cut kota stone tiles / slabs 20-25mm thick (except Kota stone) are laid. While laying tiles, care should be taken to see that joints between tiles are kept minimum and joints are thoroughly filled with FOSROC Nitotile grout polymer based joint mortor or equivalent products of Asian Paints/ / M/s M C Bauchemic / CIPY/ SIKA / Pidilite Dr fixit / Thermax / STP as approved by GE, applied as per manufacturer's instructions. |
| 12 | (vi) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company guarantee to be given by contractor after completion of water proofing work before payment.Note: (i) The rate quoted by the contractor shall be deemed include dismantling and refixing of PVC water tanks hoisted on roof, taking down and refixing of water tubing and any other fittings , re-alignment of lightening arrester strips etc if any on roof as required and nothing extra will be paid. Note: (i) The rate quoted by the contractor shall be included for dismantling and refixing of PVC water tanks hoisted on roof, taking down and refixing of water tubing and any other fittings on roof as required and no extra shall be paid.1. (ii) Supply only of Kota stone slabs will be measured and paid separately under respective item. \\" |
| 13 | Supply only of 20-25mm thick prepolished machine cut kota stone slabs /tiles of size not less than 450x450 mm size, complete all as specified and as directed |
| 14 | M&L for Screed bed or bedding layer of 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed. |
| 15 | M&L for 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and as directed. |
| 16 | M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platforms, and other similar situations complete all as specified and as directed. |
| 17 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces 5 mm in CM (1:4) mixed with WPC over 10mm in CM (1:6) finished even and smooth without using extra cement. complete all as specified and as directed. |
| 18 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement. complete all as specified and as directed. |
| 19 | M&L for rendering 10mm thick in ceilings in CM (1:3) finished even and smooth without using extra cement. complete all as specified and as directed. |
| 20 | M&L for preparation for new surface on wallsand Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm over plaster of paris putty of 2 mm thickness over plastered surface complete all as specified and as directed . |
| 21 | M&L for preparation of New Surfaces of wall and Applying two or more coats coats of Oil bound st Quality Acrelic distempering (ready Mixed) having VOC Content less then 50gms/ltr of approved manufacturer of required shade and colour over a coat of primer over 2mm thick wall putty with white or tinted incl chalk whiting, preparatory to distempering on walls complete all as specified and as directed. |
| 22 | M&L for preparation of New Surfaces on ceiling and applying a coat of alkali resistant priming paint followed by two coats of oil emulsion distemper complete all as specified and as directed . |
| 23 | M&L for complete removal of the existing treatment of any type on walls and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm over plaster of paris putty of 2 mm thickness over plastered surface complete all as specified and as directed . |
| 24 | M&L for preparation of old /New Surfaces of wall and Applying two or more coats coats of Oil bound st Quality Acrelic distempering (ready Mixed) having VOC Content less then 50gms/ltr of approved manufacturer of required shade and colour over a coat of primer over 2mm thick wall putty with white or tinted incl chalk whiting, preparatory to distempering on walls complete all as specified and as directed. |
| 25 | M&L for complete removal of the existing treatment of any type on ceiling and applying a coat of alkali resistant priming paint followed by two coats of oil emulsion distemper complete all as specified and as directed . |
| 26 | M&L for preparation of Old painted steel surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint etc complete all as specified and as directed. |
| 27 | M & L for preparing old painted wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.. |
| 28 | M & L for PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor. 110mm dia. |
| 29 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. |
| 30 | S&F powder coated aluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing etc. complete all as specified and directed . |
| 31 | S &F Powder coated aluminium Sliding window shutter , aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete all as specified and directd . |
| 32 | S&F Powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed. |
| 33 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed with alluminium wire staples complete all as specified and as directed. |
| 34 | S&F 4mm thick Plain glass, and glazing fixed in aluminium frames with rubber beading/gasket in squares exc 0.5 sq. m in each pane complete all as specified. |
| 35 | S&F 12mm thick Prelaminated particle board, Exterier grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to Aluminium frame work complete all as specified and as directed. |
| 36 | M&L 2.00 mm thick Linoleum, plain coloured, laid dry in floors including stretching, cutting and fitting and adesive etc complete all as specified and directed Note : Rates include for all cutting and waste and work in all positions and in narrow widths and before laying of linoleum floor, existing floor to be made smooth and finished properly. |
| 37 | Providing and fixing of eco-friendly light weight calcium silicate acoustical false ceiling tiles in module size of 600x600mm G.I. powder coated 24mm T grid system. Eco friendly light weight calcium silicate tiles shall be made of non-cementitious hydrated wet moulded calcium silicate slurry, reinforced with fibers and natural fillers. Free from formaldehyde and other harmful materials. Does not contain any toxic ingredients. Tiles shall be GRIHA accredited product suitable for green building applications. |
| 38 | False ceiling tiles shall have followingproperties:(a).Dimension of tiles: 595x595x15mm thick integral densified tegular/butt edged.(b). Thickness: 15mm thick integral densified tegular/butt edges with 26mm wide collar at all around the edge resting portion and 10mm thick at quadrant of the body size of 543x543mm.(c). Relative Humidity: 100% RH as per ASTM C 473-03.(d). Fire resistance: Non-combustible tile as per BS 476 part 4, Fire performance as per BS 476 Part 6 for fire propagation &class 1 as per BS 476 part 7 for Surface spread of flame.(e). Surface Burning Characteristics: Class 1 or Class A as per ASTM E 84 with Falme Developed Index (FDI) value 0 and Smoke Developed Index (SDI) value 5.(f). Acoustic control: Noise reduction coefficient (NRC) 0.5 - 0.75 as per IS 8225:1987. Sound Attenuation 30-32dB.(g). Thermal conductivity: 0.048 W/mK to 0.052 W/m²K as per IS 3346/1980 and asper ECBC code 2017.(h). Recycled content: shall have 46-50% recycled content.(i). Light reflectance: >85%.(j). Weight: 5-5.5kg/m2.(k). Density of material: 350 kg/m3 at the quadrant 10mm thick portion and 450 kg/m3 at all around the integral densified edges. (Average density 370 kg/m3 as perECBC code 2017).(l). Surface: All tiles are prime coated onboth sides. Standard factory finish in two coats whitedispersion type, solvent free paint.False ceiling tiles to be laid in true horizontal level suspended on inter locking metal T grid hot dipped galvanized iron sections of 0.33mm sheet of thickness galvanized @ 120 grams per sqm including both sides comprising of main T runners of size 24x38mm of length 3000mm, cross T of size 24x32mm of length 1200mm and secondary intermediate cross T of size 24x32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Galvanized iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall becarried out as per specifications, drawing and complete all as specified and as per directions of the Engineer-in-Charge. |
| 39 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed . |
| 40 | M& L for Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer.complete all as specified and as directed |
| 41 | M&L for preparing new or previously untreated surfaces steel Surfaces of any des-cription, n exc 10cm in width or grith, not otherwise described, and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 42 | M & L for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 43 | Taking down old, unsv aluminium/copper point wiring (light, fan, socket or power) complete, incl fixture & fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-Charge. |
| 44 | Taking down old sub-main wiring incl fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-Charge. |
| 45 | Disconnecting/dismantling of old existing un serviceable DB's any type/way 240/415 Volts with their old/un serviceable burnt MCCB/MCB's etc. complete all as specified and directed by Engr-in-Charge. NOTE for Item Nos 41 to 43 : Cost of making good the disturbed surfaces is deemed to be included in the unit quote rates. |
| 46 | M & L for point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade), ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes, Modular White Cover Plates with frames of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of cable : Havells/Polycab/Finolex/KEI, Make of Conduit : Precision/Finolex/Polycab/Modi(a) One Light etc. point controlled by one switch 5/6 Amps. |
| 47 | (b) One C/fan etc. point controlled by one switch 5/6 Amps. |
| 48 | (d) One switch socket outlet point 5/6 Amps on independent board. |
| 49 | (e) One switch socket outlet point 5/6 Amps on same board. |
| 50 | Description all as per Item No-44 above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket complete. Please Enable Macros to View BoQ information |
| 51 | Description all as per Item No-44 above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket complete. Please Enable Macros to View BoQ information |