| 1 | Taking down cement plaster on brick or stone wall etc. including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 2 | M & L for rendering 15mm thick in CM (1:4) in two layers (5mm thick in CM (1:4) with approved water proofing compound as per manufacturing instraction over backing coat of 10mm thick in CM (1:4)) on brick work or concrete surfaces finished fair & even. (Note:- WPC will be measured and paid separately) |
| 3 | M&L for 15 mm thick cement plaster in cement mortar (1:6) as on walls, finished fair and even complete all as specified and directed. |
| 4 | Supply only integral Liquid water proofing compound complete all as specified and as directed. |
| 5 | Material & Labour for complete removal of existing treatment, preparation of surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer and 1.0 mm thick white wall care putty (premium quality) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified. |
| 6 | M&L Preparation of newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior alkali resistant primer applied @ 0.90 litre/ 10 sqm over and including 1mm thick wall care putty new surfaces on external surface as directed by Engineer-in-charge |
| 7 | Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed. |
| 8 | M&L 100 mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in receiving floor Finishes complete all as specified and directed. |
| 9 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 10 | M & L for screed or bedding layer 15mm thick in cement mortar 1:6 laying floor finishes complete all as specified and as directed. |
| 11 | M&L Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 12 | M&L Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 13 | M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified |
| 14 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed |
| 15 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed |
| 16 | Dismanting of corrugated or semi corrugated Asbestos sheeting, in any roof coverings, complete all as specified and as directed by Engineer-in-charge complete all as specified and as directed. |
| 17 | S&F anodised aluminium snap grid of size 605 x 605 mm frame work for false ceiling complete all as sprcified and as directed. |
| 18 | S&F Hangers 4mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60 mm long, complete all as specified and as directed. |
| 19 | S&F for 6 mm thick 'E' board (non asbestos fibre) designer building boards fixed in aluminium frame work in ceiling flat or sloping with screws, complete all as specified and as directed. |
| 20 | Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 21 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. (Fe-410W Gde-E-250 Quality B) all as specified and as directed. |
| 22 | S&F for wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, all as specified and as directed. |
| 23 | Dismanting of wrought iron or mild steel work af any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge |
| 24 | M&L for preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 25 | Taking down PVC rain water pipe any size or pattern including all fittings all as specified and directed. |
| 26 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/laid in floor complete all as specified and as directed. |
| 27 | S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 28 | S&F in repair 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 29 | S&F in repair 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed. Please Enable Macros to View BoQ information |