| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. a) All kinds of soil |
| 2 | Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:5:10 (1 cement:5 coarse sand:10 graded stone aggregate 40mm nominal size). |
| 3 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. a) 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size |
| 4 | Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) |
| 5 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 6 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. a) All works upto plinth level |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. a) All works above plinth level upto floor V level |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth level: a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Centering and shuttering including strutting propping etc. and removal of form work for:- |
| 10 | Foundations, footings, bases of columns etc. for mass concrete. |
| 11 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 12 | Columns, pillars, piers, abutments, posts and struts. |
| 13 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Suspended floors, roofs, landings, balconiesand access platform. |
| 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 16 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 17 | Disposal of excavated earth by way of mechanical transport lead upto 10.00 km. |
| 18 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in cement mortar 1:6 (1 cement:6 coarse sand). |
| 19 | Extra for brick work with common burnt clay bricks / cement concrete bricks in superstructure above plinth level upto floor five level. |
| 20 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : a)Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 21 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 22 | 12mm cement plaster of mix. 1:6 (1 cement:6 fine sand). |
| 23 | 15mm Cement plaster on the rough side of single or half brick wall of mix: a) 1 : 6 ( 1 cement : 6 fine sand) |
| 24 | 6mm cement plaster to ceiling of mix. 1:3 (1 cement:3 fine sand). |
| 25 | Making of grooves 12mm x10mm between brick sand RCC (LMR) |
| 26 | Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections |
| 27 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 28 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. a) Granite Work |
| 29 | Providing and laying vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. a) Size of tile 600x600mm. |
| 30 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. a) Size of tile 600x600 mm |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 32 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 33 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. A) 2 mm thick |
| 34 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 35 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. A) Two coat |
| 36 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 37 | Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 38 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. A) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 39 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. a) Crushed. |
| 40 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). a) Sal Wood. |
| 41 | Providing and fixing 35mm thick ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 42 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminum snap beading shall be paid in basic item.) a)With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm) |
| 43 | Providing and fixing 30mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : a) Second class deodar wood |
| 44 | Providing and fixing 30mm thick glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. A) Second class deodar wood |
| 45 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. A) Fixed to openings / wooden frames with rawl plugs screws etc. |
| 46 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 47 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. A) Two or more coats on new work. |
| 48 | Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 49 | a) 100x75x4 mm |
| 50 | 75x63x4mm |
| 51 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 52 | 300x16mm |
| 53 | 250x16mm |
| 54 | Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 55 | 200x10 mm |
| 56 | 150x10 mm |
| 57 | Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 58 | 300 mm |
| 59 | 200 mm |
| 60 | 125 mm |
| 61 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : a) Twin rubber stopper |
| 62 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete. |
| 63 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: a) W.C. pan with ISI marked white solid plastic seat and lid |
| 64 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : a) Stainless steel AISI-304 (18/8) Round basin 405x355 mm with single 15mm C.P. brass pillar trap |
| 65 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : i) Kitchen sink without drain board a) 610x510mm bowl depth 200mm |
| 66 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: a) Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms. |
| 67 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: i) Semi rigid pipe: a) 40 mm dia |
| 68 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 69 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 70 | Providing and fixing unplasticised- Rigid PVC pipes conforming to IS:13592 Type A including joining with seal ring conforming to IS:5382 leaving 10mm gap of thermal expansion: with necessary stays / clamps with fasteners having working pressure of 4 kg / cm2 of make Supremen or finolex only:- all complete including testing of joints and pipes for leakage etc. (Including cost / carriage of material by Mechanical transport). |
| 71 | 50mm dia (LMR) |
| 72 | 75mm dia (LMR) |
| 73 | 110mm dia (LMR) |
| 74 | Providing and fixing unplasticised- PVC moulded fittings / accessories for unplasticised -Rigid PVC pipes conforming to IS:13592 Type A including joining with seal ring & insertion rubber washer 3 mm thick conforming to IS:5382 leaving 10mm gap of thermal expansion: with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4 kg / cm2 of make Supremen or finolex only:- all complete including testing of joints and pipes for leakage etc. (Including cost / carriage of material by Mechanical transport). i) PVC Plain Bend |
| 75 | 50mm dia (LMR) |
| 76 | 75mm dia (LMR) |
| 77 | 110mm dia |
| 78 | PVC Door Bend |
| 79 | 75mm dia (LMR) |
| 80 | 110mm dia (LMR) |
| 81 | PVC Plain TEE |
| 82 | 50mm dia (LMR) |
| 83 | 75mm dia (LMR) |
| 84 | 110mm dia (LMR) |
| 85 | PVC DoorTEE |
| 86 | 50mm dia (LMR) |
| 87 | 75mm dia |
| 88 | 110mm dia |
| 89 | PVC Reducer Door TEE |
| 90 | 110mm x 75mm (LMR) |
| 91 | PVC Reducer Plai TEE |
| 92 | 110mm x 75mm (LMR) |
| 93 | PVC Off Set |
| 94 | 50mm dia (LMR) |
| 95 | 75mm dia (LMR) |
| 96 | 110mm dia (LMR) |
| 97 | PVC Coupler / Collar |
| 98 | 50mm dia (LMR) |
| 99 | 75mm dia (LMR) |
| 100 | 110mm dia (LMR) |
| 101 | PVC Vent Cowl |
| 102 | 110mm (LMR) |
| 103 | PVC Floor / Nahani Trap |
| 104 | 110mm x 75mm (LMR) |
| 105 | 110mm x 100mm (LMR) |
| 106 | Providing and fixing soap dish (CP brass) with brackets, nuts & Screws complete etc. of make hindware/cera / Jaquar only: (with all carriages) |
| 107 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 108 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 109 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 |
| 110 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 111 | Providing and unplasticised PVC connection pipe with brass unions: 45cm length. A) 15mm nominal bore. |
| 112 | Providing and fixing 8mm dia CP / SS jet with flexible tube upto 1 metre long with SS triangular plate to Euorpean type W.C. of quality and make as approved by Engineer-in-charge. |
| 113 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 114 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: i) Internal work-Exposed on wall : |
| 115 | 15mm dia nominal bore (medium) |
| 116 | 25mm dia nominal bore (medium) |
| 117 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete: a) 25 to 40 mm nominal bore |
| 118 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) : a)25 mm nominal bore |
| 119 | Providing and fixing G.I. Tank Nipple of suitable dia of make UNIK or New or equivalent ISI marked as approved by Engineer incharge at site all complete including testing of fittings and joints for leakage etc. (Incl. carriages): a) 25mm dia nominal bore. |
| 120 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 121 | 25mm dia nominal bore |
| 122 | 40mm dia nominal bore |
| 123 | Providing and fixing of stainless steel Rainwater khurra jali to be placed at roof and mumty levels of make ChILLY or CAMRY or equivalent all complete: Square or circular in shape of dia / size:( Incl. all carriages): 150mm(LMR) |
| 124 | Providing and fixing Electric motor pump 1.5 H.P. (Cromption /Khalsi) incl. fittings. (LMR) |
| 125 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. |
| 126 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 127 | Supplying and fixing C.I. cover without frame for manholes: a) 455x610mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg. |
| 128 | Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. Group A |
| 129 | Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. |
| 130 | 2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire |
| 131 | 2 X 4.0 SQ.MM + 1 X 4.0 SQ.MM Earth Wire |
| 132 | 2 X 6.0 SQ.MM + 1 X 6.0 SQ.MM Earth Wire |
| 133 | 4 X 16.0 SQ.MM + 1 X 6.0 SQ.MM Earth Wire |
| 134 | Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit asrequired. a) 2 Pair |
| 135 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mmsolid copper conductor PE insulated, shielded with fine tinnedcopper braid and protected with PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required. |
| 136 | Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required. |
| 137 | 25 mm |
| 138 | 40 mm |
| 139 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. |
| 140 | Antenna socket outlet |
| 141 | Bell Push |
| 142 | Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required. |
| 143 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 144 | Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. |
| 145 | Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modularswitch, connection,painting etc. as required. |
| 146 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 147 | Supplying & fixing suitable size GI box wih modular plate andcover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\"curve including connections, painting etc. as required. |
| 148 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. |
| 149 | 12 way , Double door |
| 150 | 16 way , Double door |
| 151 | Supplying and fixing following rating, 240/415 V, 10 kA, \\"C\\"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 152 | Single Pole 6 to 32 Amp |
| 153 | Single pole and neutral 6 to 32 Amp |
| 154 | Single pole and neutral 40-63 Amp |
| 155 | Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required. |
| 156 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 157 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 158 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 159 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuitprotection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved byEngineer in charge. a) 40 watt LED 4 feet with min. lumen output (4000) lm |
| 160 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 161 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. a) LED Street Light 90W |
| 162 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim a) 12-15 watts |
| 163 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. A) 300mm/12\\" sweep exhust fan |
| 164 | SITC of Meter Panel-1 Indoor (IP:42) free Wall/standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 165 | INCOMBER 100 Amp, 36 KA, FP MCCB ICU = 100% ICS |
| 166 | Aluminium Bus Bar 200 Amp set of 4 strips 18\\" |
| 167 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 168 | OUTGOINGS |
| 169 | 40-63 A 1-Phase Energy Meter |
| 170 | 25 A SPN MCB 10 Ka \\"C\\" Curve |
| 171 | 63 A SPN MCB 10 Ka \\"C\\" Curve |
| 172 | SITC of Meter Panel-2 Indoor (IP:42) free Wall/standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. |
| 173 | INCOMER 100 Amp, 36 KA, FP MCCB ICU = 100% ICS |
| 174 | Aluminium Bus Bar 150 Amp set of 4 strips 18\\" |
| 175 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. |
| 176 | OUTGOINGS |
| 177 | 40-63 A 1-Phase Energy Meter |
| 178 | 25 A SPN MCB 10 Ka \\"C\\" Curve |
| 179 | 63 A SPN MCB 10 Ka \\"C\\" Curve |
| 180 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. a) 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 181 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 182 | 3.5 C X 150 Sq.mm A2XFY |
| 183 | 3.5 C X 70 Sq.mm A2XFY |
| 184 | Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet) |
| 185 | 3½ X 150 sq. mm (50mm) |
| 186 | 3½ X 70 sq. mm (38mm) |
| 187 | Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC |
| 188 | Supply,installation with foundation as per approved Drawing 11 Mtr SP-56 M.S Pole |
| 189 | Supply,installation of Structural Steel as per Standard Approved Drawing |
| 190 | Supply,Installation and Commissioning of 11 KV Air Break Switch(200 Amps). |
| 191 | Supply,Installation of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 192 | Supply,Installation of 11 KV HG Fuse Unit . |
| 193 | Supply,Installation of Disc Insulator(B&S)70 KN suitable for 100 sq.mm Triple AAAC. |
| 194 | Supply and Installation of 100 Sq.mm AAAC Triple AAAC. |
| 195 | Supply,Installation of 11 KV Pin Insulator suitable for 100 sq.mm Triple AAAC. |
| 196 | Supply and Erection of 150 mm Dia. Heavy Class G.I Pipe for the Cable Protection. |
| 197 | Supply and Installation of Anti Climbing Device |
| 198 | Supply, installation, testing and commissioning of following capacity(continuous loading) BEE 3 Star rated (Corresponding Level as per BISamended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase,50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural AirNatural] copper wound transformer (Electrolytic grade 99.9% pure copper,Core made of first grade Cold Rolled Grain Oriented (CRGO) Core gradeMOH or better),Dielectric material shall be type -A, suitable for outdoor/indoor applications with On Load Tap Changer (OLTC) on HV sidehaving AVR relay and Remote Tap Changer Control (RTCC) for automaticsensing of incoming voltage, automatic operation of OLTC and facility forremote and manual operation of OLTC HV side in range of +5% to -15% insteps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmmXLPE cable of 11 KV grade, including bus trunking arrangement on LV sideincluding supplying and laying of copper conductor multicore control cablefrom transformer to HT breaker/panel for safety tripping, complete with allaccessories and safety provisions as per relevant IS 1180 (Part-3) includingfirst filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying andgrouting of suitable M.S. Channel with all accessories and transformer shallbe confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and duly ISI Marked and as per CPWD specifications complete in all respects etc asrequired at site. The maximum flux density in any part of the core and yoke atrated voltage and frequency shall be such that the flux density with +12.5percent combined voltage and frequency variation from rated voltage andfrequency does not exceed 1.9 Tesla. The permissible temperature-rise shallnot exceed 40 dg.C for oil and 45 dg. C for winding up to 200 KVA and 45 dg.Cfor oil and 50 dg. C for winding for above 200 KVA. Inside of tank shall bepainted with varnish or liquid resistant paint. For external surfaces one coatof thermo setting powder paint or one coat of epoxy primer followed by twocoats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall bereferred for paint thickness for normal to medium corrosive atmosphere. Forhighly polluted atmosphere and special application external paint work shallbe as per direction of Engineer-in-Charge. Design ambient condition : a) airtemperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone asper location of site, d) Altitude as per location/site. Noise level Shall notexceed limits as per NEMA TR-1 with all accessories running measured asper IEC 551 / NEMA standard. The transformer should have QR code whichshould contain drawing, test report OEM manual, Geo- Tag of manufacturinglocation etc. Marking Each transformer shall be provided with rating platemade of anodized aluminum/ stainless steel material securely fixed on theouter body, easily accessible,as per IS: 1180 Part-3. The entries on the ratingplate shall be indelibly marked. |
| 199 | 3 C x 35 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable). |
| 200 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 201 | Supplying,Installation,Testing and Commissioning of G.I Earthing Electrode of Size 50 x 3000mm with GI Pipe Outer Dia. 58 mm (+-) 5 %,Length 3000 mm,Inner & Outer GI Strip Size 32X6mm,Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs. |
| 202 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. |
| 203 | Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete. |
| 204 | Sand from Hut Mashka for an av. lead of 55.00 km. by M.T. |
| 205 | Stone aggregate (Crusher bajree) below 40mm nominal size from Hut Mashka for an av. lead of 55.00 km. by M.T. |
| 206 | Stone aggregate 40mm nominal size & above from Hut Mashka for an av. lead of 55.00 km. by M.T. |
| 207 | Bricks from Kathua for an average lead of 170.00 Km. by M.T. Please Enable Macros to View BoQ information |