| 1 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-incharge. imported kail wood |
| 2 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II IS : 12823 marked |
| 3 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 4 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First KD wood |
| 5 | Providing and fixing glass panes with putty and Beeding in doors, windows, clerestory windows, all complete with : 4.0mm thick glass panes |
| 6 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded |
| 7 | Providing Colour Coated Hi-Rib sheet roofing 0.50mm thick including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 complete job. including ridges/valley/hips 0.50mm thick |
| 8 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) including all cost and carriage complete job |
| 9 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 10 | Finishing walls with water proofing cement paint of required shade onNew work (two or more coats applied @ 3.84 kg/10sqm) |
| 11 | Distempering with dry distemper of approved brand and manufacture (twoor more coats) and of required shade on new work, over and includingwater thinnable priming coat to give an even shade |
| 12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete11.52.1 |
| 13 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 14 | Providing and laying gang saw cut of specified thickness, mirror polishedpre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 18 mm thick |
| 15 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 16 | Providing and laying of stone soling hand packed including all cost and carriage complete job as per direction of Engineer Incharge at Site. |
| 17 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies, beams and access platforms. |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 21 | Dry random rubble masonry with hard stone in foundation and plinth: With bond stone. Nallah for soakage pit |
| 22 | Construction brick massionary manhole with 7.5 class designation bricksin cement mortar 1:4 (1 cement; 4 fine sand ) CI cover with frame , foundation concrete 1:3:6 (1 cement : 3 fine sand :6 graded stone aggregrate 20 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished smooth with a floating coat of neat cement on walls and bed concrete etc complete as per standard design: Inside dimensions 300x300 x300 mm deep as per the directions of site engineer incld all cost and carriage. |
| 23 | Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium pipe of required dia, conforming toIS:12818(Type B), including required hire and labour charges, fittings andassories like tees elbows collars.cowls,ptraps,s traps ,door bends etc allcomplete for all depths as per direction of Engineer-in-charge. 75 MMNOMINAL SIZE DIA |
| 24 | Supplying, assembling, lowering and fixing in vertical position in borewell, unplasticized PVC medium pipe of required dia, conforming to IS:12818(Type B), including required hire and labour charges, fittings andassories like tees elbows collars.cowls,ptraps,s traps ,door bends etc allcomplete for all depths as per direction of Engineer-in-charge. 100 MMNOMINAL SIZE DIA |
| 25 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. PN-16 pipe , 25mm or above OD(SDR-7.4) |
| 26 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. As per direction of Engineer incharge at site |
| 27 | Providing and fixing 15 mm nominal bore C.P. brass Wall Mixer/basin mixer of approved brand and manufacture including all fittings and fixtures, complete job |
| 28 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 29 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 30 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets ofthe same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 31 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 32 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as perI.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm |
| 33 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Semi rigid pipe Flexible pipe 40 mm dia |
| 34 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 35 | Providing and fixing 100 mm PTMT grating for gully trap. |
| 36 | Providing and fixing of PVC collars af approved make and quality |
| 37 | Providing and fixing of PVC Bends 75 mm af approved make and quality |
| 38 | Providing and fixing of PVC Bends 100 mm af approved make and quality |
| 39 | Providing andf ixing of PVC cowl af approved make and quality |
| 40 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mmheight of approved quality and colour, weighing not less than 300 gms |
| 41 | Providing and fixing of 75 mm dia floor trap of approved brand, allfixtures involved, complete job |
| 42 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 43 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishingand making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 44 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 45 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 46 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded |
| 47 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. Made of G.I. wire of dia 4 mm |
| 48 | Taking of Geo Tag Photographs of size 125mmx250mm before execution, during execution and after execution of work (04 No. Each Pre, Post, After execution) to be submitted with the bill complete job. (Geo Tag Photographs showing Name of Work, Location and Longitude/ Latitude).(Pre, Post, After execution). Please Enable Macros to View BoQ information |