| Sl. No. | Item Description |
| 1 | Pre-construction activity includes soil investigations, Foundation & Structure Design, preparation of detailed shop and builtup drawings as per site requirement, through associated consultant and proof checking of structural design of all components as per the terms and condition of NIT all complete & as per the direction of Engineer-In-Charge. (Payment will be made after completion of full job) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 4 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil.Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil |
| 7 | Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 10 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 11 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 12 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 13 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 14 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform . |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for: Shelves (Cast in situ) |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for:Stairs, (excluding landings) except spiral-staircases |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for: Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc., including edges |
| 23 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 26 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum. |
| 27 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works above plinth level upto floor V level : Concrete of M25 grade with minimum cement content of 330 kg /cum. |
| 28 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 29 | Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.300 mm wide. |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse) |
| 32 | Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level.Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 33 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 34 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 35 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels..Granite of any colour and shade.Area of slab upto 0.50 sqm |
| 36 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab over 0.50 sqm |
| 37 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 38 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
| 39 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 40 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 41 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 42 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 43 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 44 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size :Second class teak wood |
| 45 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete :20 mm dia |
| 46 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm |
| 47 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm |
| 48 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm |
| 49 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm |
| 50 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 51 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :100 mm |
| 52 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 53 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitablewooden block in all the three legs. The frame shall be covered with fiberglass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 54 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate forforming hollow rails and styles, with wooden frame and suitableblocks of seasoned wood inside at required places for fixingof fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. |
| 55 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6mm for diagonal braces and central cross piece |
| 56 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 57 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 58 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 59 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 60 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Dark shade pigment using ordinary cement |
| 61 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble |
| 62 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 63 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 64 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 65 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 66 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of Size of Tile 600 x 600 mm |
| 67 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 68 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm |
| 69 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 70 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion..Bend 87.5°110 mm bend |
| 71 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain). 110 mm Shoe |
| 72 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 73 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 74 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) |
| 75 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 76 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 77 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete:New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 78 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 79 | Applying priming coat:With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 80 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 81 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 82 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 83 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 84 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 85 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 86 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board.510x1040 mm bowl depth 250 mm |
| 87 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 88 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.Semi rigid pipe.32 mm dia |
| 89 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.Semi rigid pipe.40 mm dia |
| 90 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 91 | Providing and fixing soil, waste and vent pipes :100 mm diaCentrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 92 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :For 100 mm dia pipe |
| 93 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm dia Sand cast iron S&S as per IS - 3989 |
| 94 | Providing and fixing plain bend of required degree.100 mm diaSand cast iron S&S as per IS : 3989 |
| 95 | Providing and fixing heel rest sanitary bend 100 mm dia Sand cast iron S&S as per IS - 3989 |
| 96 | Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x100x100 mm..Sand cast iron S&S as per IS - 3989 |
| 97 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100x100x100 mm.Sand cast iron S&S as per IS - 3989 |
| 98 | Providing and fixing single equal plain junction of required degree :100x100x100 mm.Sand cast iron S&S as per IS - 3989 |
| 99 | Providing and fixing terminal guard :100 mm.Sand cast iron S&S as per IS - 3989 |
| 100 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm |
| 101 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet.Sand cast iron S&S as per IS: 3989 |
| 102 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :100 mm diameter pipe |
| 103 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less |
| 104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall: 15 mm nominal dia Pipes |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall:25 mm dia nominal bore |
| 106 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall :40 mm dia nominal bore |
| 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.\\":15 mm nominal dia Pipes |
| 108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. :20 mm dia nominal bore |
| 109 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.:25 mm dia nominal bore |
| 110 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work:50 mm dia nominal bore |
| 111 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore. |
| 112 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 113 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 114 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 115 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100mm |
| 116 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 117 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :50 mm diameter pipe |
| 118 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support Including fittings & fixtures for tank shall be paid separately. |
| 119 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
| 120 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 121 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore |
| 122 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931.15mm nominal bore |
| 123 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 124 | Providing and fixing PTMT grating of approved quality and colour.Circular type.100 mm nominal dia |
| 125 | Providing and fixing PTMT grating of approved quality and colour.Circular type.125 mm nominal dia with 25 mm waste hole |
| 126 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.15 mm nominal bore with 30 cm length |
| 127 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P type .With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 128 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 129 | Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :.Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 130 | Extra for depth for manholes :Size 90x80 cm.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 131 | Extra for depth for manholes :Size 120x90 cm.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 132 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion.Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 133 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 134 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides |
| 135 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.0 mm thickness |
| 136 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-incharge. (Only weight of grill to be measured for payment). |
| 137 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge..With stainless steel cover plate minimum 1.25 mm thickness |
| 138 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 139 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium |
| 140 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 141 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer- in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 142 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). |
| 143 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
| 144 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 145 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of ClassA category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) 25 mm thick |
| 146 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 147 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 148 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 149 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 150 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required : 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 151 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 152 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 153 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 154 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. : 2 Pair |
| 155 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 156 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.:20 mm |
| 157 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.:25 mm |
| 158 | Supplying and fixing modular switch/socket on the existing modular plate & switch box i/c connection but excluding modular plate etc. as required.Telephone socket outlet |
| 159 | Supplying and fixing modular switch/socket on the existing modular plate & switch box i/c connection but excluding modular plate etc. as required TV antenna socket outlet |
| 160 | Supplying and fixing modular switch/socket on the existing modular plate & switch box i/c connection but excluding modular plate etc. as required Bell push |
| 161 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 162 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 163 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required: 1 or 2 Module (75mmX75mm) |
| 164 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 165 | Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 166 | Supplying and fixing call bell/buzzer suitable for single phase, 230V, complete as required. |
| 167 | Supplying and fixing brass batten/angle holder i/c connection etc. as required. |
| 168 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim. 18 watt |
| 169 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, GR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm): 36 watt |
| 170 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt). Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC140, 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm): 18-22 Watt. |
| 171 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B,3 nos.metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR ,PVC insulated copper conductor single core cable and earthing etc.as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 172 | Supplying, Installation of following size metallic exhaust fan in the existing opening, including making hole to suit the size of the above fan, making good the damages, connection, testing, commissioning etc. as required. 225/230 mm Exhaust fan (light duty) |
| 173 | Supplying, Installation of following size metallic exhaust fan in the existing opening, including making hole to suit the size of the above fan, making good the damages, connection, testing, commissioning etc. as required. 300 mm Exhaust fan (heavy duty). |
| 174 | Supplying and fixing following way, single pole and neutral,Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) :12 way , Double door |
| 175 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) :4 way (4 + 12), Double door |
| 176 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.: Single pole |
| 177 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.: Single pole and neutral |
| 178 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.: Triple pole and neutral |
| 179 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 180 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 63 A |
| 181 | Supplying, installation, testing & commissioning of cubicle type LT panel suitable for 415V, 3 Phase, 4 Wire 50 Hz Ac supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100mmx 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 2.5 sq. mm. FRLS PVC insulated coppr conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-Note- All MCCBs of 250A & above shall be Microprocessed release with O/L, S/C protection and below 250A shall be thermal magnetic relaese. All MCCB shall be with rotary handle and have Ics = 100 % Icu. :Note- All MCCBs of 250A & above shall be Microprocessed release with O/L, S/C protection and below 250A shall be thermal magnetic relaese. All MCCB shall be with rotary handle and have Ics = 100 % Icu.:Non- Essential panel :Incomer:i) 250 Amps TPN MCCB 35 KA -1 No.ii) Indicating LED Lamp (R/Y/B) with back up control MCBs - 1 set iii) Multi function meter with required capacity-1set: Busbar:4 strip aluminium bus bars of minimum of 400 Amps -- 1 Set: Outgoing:i) 125Amps TPMCCB 25 KA breaking capacity -3Nos.: ii) 100Amps TPMCCB 25 KA breaking capacity -3Nos.: Essential Main panel :Incoming::i) 100 Amp 4 Pole 35 KA MCCB - 1 Nos. :ii) RYB LED indicating Lamp - 1 Set : iii) Multi function meter with required capacity-1set iii) Multi function meter with required capacity-1set,: TPN aluminium bus bars of minimum of 200Amps capacity : Outgoing:63 Amp 3 Pole 25 KA MCCB – 3 Nos.: 32 Amp TPN MCB- 2 nos.:,63 Amp 3 Pole 25 KA MCCB – 3 Nos.: 32 Amp SPN MCB- 4 nos. |
| 182 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 183 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as reqd. |
| 184 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 185 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 186 | Providing and fixing G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as reqd. (For horizontal run) |
| 187 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as reqd. (For vertical run) |
| 188 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as reqd. |
| 189 | Providing and fixing testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as reqd. |
| 190 | Providing and laying G.I. tape 32 mm x 6 mm from earth electrode directly in ground as reqd. |
| 191 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE armoured aluminium conductor power cable of 1.1 KV grade of following size in the existing RCC/ Hume/ Stoneware/ HDPE/ Metal Pipe/ Existing open trench etc as required.:3.5 x 185 sqm |
| 192 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE armoured aluminium conductor power cable of 1.1 KV grade of following size on wall with GI pipe etc as required.: 4 x 25 sqm |
| 193 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE armoured aluminium conductor power cable of 1.1 KV grade of following size on wall with GI pipe etc as required.: 3 x 10 sqm |
| 194 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.: 3 X 10 sq. mm (22mm) |
| 195 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.: 3½ X 185 sq. mm (57mm) |
| 196 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. : 4 X 25 sq. mm (28mm) |
| 197 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.: 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 198 | Supply & installation, testing and commissioning of fire extinguisher cylinder etc as reqd. : 4.5 kg CO2 type |
| 199 | Supply & installation, testing and commissioning of fire extinguisher cylinder etc as reqd. 5 Kg ABC type |
| 200 | Supply & installation, testing and commissioning of electric driven following : complete in all respect as reqd.:a) Monoblock pump set with bronze impeller, stainless steel shaft, mechanical seal, cast iron body, 450 LPM, 40 meter head complete with suitable rating induction motor TEFC type suitable for operation on 415 volts, 03 phase, 50 HZ, AC, 2950 RPM for enclosure, horizontal foot mounted type with class B or F insulation etc complete as reqd.: b) MS fabricated common base plate, foundation bolts etc as reqd.: c) suitable cement concrete foundation duly plastered complete with anti vibration pads. |
| 201 | Fabrication, supplying, installation, testing & commissioning of out door type electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin pfoof, powder coated of approved shade, cable alley, inter connection having switchgears and accessoried mounting and internal wiring earth terminal numbering etc. complete in all respect, suitable of operation on 415V, 3 Phase, 50HZ, AC supply with enclosure protection class IP 52i/c P/F following accessories etc. as required.:A Terrace pump control (for two pumps) :(I) Incomer :04 pole 100 amps MCCB 25 KA thermal magnetic release (ics=100%lcu) 01 No :Digital type voltmeter (0-500 volts) with selector switch 01 set :Digital type Ammeter with selector seitch & CT's etc. 01 set :LED type indicating lights 03 os: TP & N Aluminium bush bar 200 amps rating- 01 set :(II) Outgoing :32 amps TP MCB C series with suitable HP fully automatic star delta sarter with over load protection, single phase preventor complete with all accessories and internal writing required for manual operation, selector seitch for local/ remote, auto/ manual/ off operation with LED type indication lights to mark ON-Off position of pumps :- 02 sets |
| 202 | Supplying, laying and fixing of one number PVC insulated and PVC sheathed, XLPE Aluminium conductor armoured power cable 1.1 KV grade of following xize in the existing \\" GI pipe/ SW pipe/ PVC pipe or iin the existing trench or on surface or in the existing cable tray etc as reduired.:3x10 sqmm |
| 203 | Supplying, laying and fixing of one number PVC insulated and PVC sheathed, XLPE Aluminium conductor armoured power cable 1.1 KV grade of following xize in the existing \\" GI pipe/ SW pipe/ PVC pipe or iin the existing trench or on surface or in the existing cable tray etc as reduired.: 3.5x 25sqmm |
| 204 | Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5x25 sqmm (28mm) |
| 205 | Supplying and laying control wiring with multicore copper standard conductor of following sizes PVC insulated, PVC sheathed armoured under ground cable between various pressure switch and system controller/ starter etc on surface/ existing cable tray/ existing pipe complete with connections at both end with glands etc. as required.:2x1.5 sqmm |
| 206 | Fabrication, supplying, installation, testing and commissioning of wall mounted remote control panel for fire fighting system fabricated from not less than 1.6mm thick CRCA sheet, powder coated of approved shade, complete internal wiring, ammeter (0-30 Amp) Voltmeter (0-500) volts with selector switches for both ammeter and voltemeter, indicating lamps, auxillary relays, accessories, numbring lettering complete in all respect and consisting of the following as required.:A) Suitable On/Off push button operation and LED indication of pumps : b) Suitable auxillary contactor :c) Suitable audio/ visual indication of operation of pump with reset push buttons as required :d) Suitable control MCB |
| 207 | Supplying, installation, testing & commissioning 0-10 kg/cm2 On/Off pressure switch of pressure range as per CPWD specification in delivery line of pump alongwith control wiring for auto starting & auto stopping of terrace fire pump complete with all neccessary accessories etc as required |
| 208 | Supply, fixing testing and commissioning of butterfly valve PN 1.6 gear, with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets, conforming to IS 13095/ relevant IS with upto date ammendments of following sized as reqd.:100 mm dia |
| 209 | Providing, installation, testing and commissioning of dual plate non- return valve of following sizes complete with rubber gasket, GI bolts, Nuts and washer etc as reqd :100 mm dia |
| 210 | Supply and fixing 63 mm 2 way FBC of CI body with 02 nos brass gunmetal male instantaneous inlet couplings complete with cap and chain as reqd. for 100 mm dia M.S. pipe connection conforming to IS: 904 alongwith MS enclosure not less than 0.9mx 0.75mx 0.m m fabricated from 1.6mm thick sheet steel with full glass on front side to accomdate the same including painting with red colour as reqd. The should be mounted on suitable raised platform of brick masonary work. |
| 211 | Supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top glanged connection to riser, drain arrangment with 25mm dia Gun Metal wheel valve with required acessories, pressure gauge and painting with synthetic enamel paing of approved shade as required. |
| 212 | Supplying installation testing & commissioning of 150 mm dia bourdan type stainless steel dial presure gange having celibration of 0-16 kg/ sq cm complete etc as required. |
| 213 | SITC of CI body flage type serviciable suction/ POT strainer with (S.S/ Brass Merch) confirm to relevent IS specification up to date compete with fixing nut bolts washer, gasket etc complete as reqd.:100 mm dia |
| 214 | :Providing, laying, testing & commissioing of 'C' class heavy duty MS pipe conforming to IS 1239/3589 (which ever is applicable) i/c fittings like elbows, tees, flages, tapers, nuts, bolts, gaskets etc fixing the pipe on the wall/ celling/ floor with suitable clamps of any suitable arrangement as per site condition and painting with two or more coats of synthetic enamel paint of required shade complete as required.100 mm dia |
| 215 | Providing, laying, testing & commissioing of 'C' class heavy duty MS pipe conforming to IS 1239/3589 (which ever is applicable) i/c fittings like elbows, tees, flages, tapers, nuts, bolts, gaskets etc fixing the pipe on the wall/ celling/ floor with suitable clamps of any suitable arrangement as per site condition and painting with two or more coats of synthetic enamel paint of required shade complete as required. :25 mm dia |
| 216 | Supply and fixing first-aid hose reel with MS construction spray painted in post office red, conforming to IS 884 with upto date amendments, complete with the following as reqd. :a) 30 m long 20 mm nominal internal dia water hose thermoplastic(textile reinforced) type -2 as per IS: 12585 : b) 25mm (nominal internal) dia gun metal globe valve & nozzle. :c) Drum and brackets for fixing the equipments on wall. : d) Connections from riser with 25mm dia. Stop valve (Gun Metal and MS pipe) |
| 217 | Supply and fixing single headed yar hydrant valve with 01 no. 63 mm dia instantaneous FM Gum metal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank gunmetal cap and chain as reqd. |
| 218 | Supply and fixing 63mm dia 15 mtr long RRl hose pipe with 63mm dia male and female Gun metal coupling duly binded with FI wire rivets etc confirming to IS 636 (type A) as reqd. |
| 219 | Supply and fixing of hose cabinet of size 750mmx 600mmx 2500mm made of 1.6mm thick MS sheet with 06mm thick nominal glazed glass door i/c necessary locking arrangement suitable ot accommodate external hydrant with butterfly valve 02 no 15mtr long hose pipe, 1 no. branch pipe mounted on wall OR raised brick platform & duly painted with post office red externally and white internally synthetic enamel paint complete in all respect ofr external hydrant as reqd. |
| 220 | Supplying and fixing 63mm dia gunmetal branch pipe with 20mm nominal internal diameter size gunmetal nozzle conforming to IS 903, ssuitable for instantaneous connection to inter- connect hose pipe couppling as reqd. |
| 221 | Supply, Installation, Testing & Commissioning of Flat Plate collector (FPC) Solar Water Heating System comprising of solar flat plate collector ISI Marked made of copper sheet/copper tube, absorber toughened glass cover and aluminium extruded channel confirm to IS: 12933 (Part 1,2,3&5). The system shall have temperature gauges, strainer, water meter 2 nos., cold and hot water tank. The system shall have suitable electric backup complete with control and power wiring etc., as following. 1. Cover plate: cover plate shall be toughened glass and thickness of 4.0 mm (min) conforming to section-1 of IS: 12933(pt-2)/2003 the solar transmittances of the cover plate shall be minimum 82 percent at near normal incidence. 2. Collector box: collector box shall be made of aluminium sections. The type grade, size, and finish of the material used shall be as per section-2 of IS:12933 (pt-2)/2003: the minimum thickness of aluminium shall be as under:a. Channel section for sides 1.6 mm b. Sheet for bottom 0.7 mm c. Support for glass retaining 1.2 mmd. Sheet for entire body 1.0 mm The insulation of collector box shall be minimum 0.96 sq.m 0C/W for back insulation and minimum 0.48 m square degree c/w for side insulation conform to sec. 4 of IS 12933 (Part – 2) / 2003. (b)Gaskets and grommets: gaskets and grommets shall conform to Sec. 5 of IS 12933 (pt-2)/2003. 3.Absorber Shall Consist of riser, Header and Sheet for absorber. The Diameter of header shall be 25.4 +/-0.5mm and thickness 0.71mm. The Diameter of riser shall be 12.7 + /-0.5 mm and thickness 0.56mm and made of copper only. The distance between the risers from centre to centre shall be 120mm. type grade, size , workmanship and finish of the material used shall be as per section- 3 of IS : 12933 (pt -2 )/2003 the sheet for absorber shall be of copper sheet 34 gauge/copper tube (at least 10 nos.) 4.Riser and header assembly designed for working pressure up 245 k pa (2.5 kg/ cm square) shall be tested for leakage at a minimum hydraulic pressure of 490 k pa (5 kg/ cm square). Sheet for absorber shall be made of copper only. Type Grade,size,workmanship and finis of the material used shall be per Section -3 of IS: 12933 (pt -2) /2003.5.HDPE/LDPE cold water tank and hot water tank shall be dully erected on MS angle /channel duly painted with dual coats of enamel paint. The overall structure of solar collector plate module shall bedesign to with stand wind velocity of 100 kms /hr (minimum) or more as per site. 6.Hot water tank : The tank capacity shall be minimum 1.25 time the rated capacity of system.Inner tank material shall be stainless steel SS 316, as per IS 1730 GRADE SS304-2B. Hot water shall be insulated with high density injected PUF insulation: 50 mm, of 50 mm thickness between inner and outer tank ensures maximum heat rotenone ever season. 7. Suitable nos. ISI Marked electrical heaters along control panel, suitable breaker all protections, and all safety provisions so as to achieve 600C temperature rise in an hour. The range of thermostat shall be upto 800C.: 500 LPD |
| 222 | Design,Supply, Installation, testing and commissioning of ductable Evaporative air cooling system for cooling an enclosed area of approximately 1800 sq ft with ceiling ht 12ft including all mechanical, electrical, water supply and ducting works as per the following design parameters:Wall mounted, Discharge Type- Side/Top, Air Flow capacity-25000-30000CMH (15500- 17500 CFM (m³/hr), Static Pressure-Minimum 390Pa (mm Wg)-40, Power - 2.2-3.0 kw, Suitable for Area Covered- Upto 2000 Sq. Ft., Motor Power-1440 RPM 3 Phase ISI marked, 3.7 kw, Power Recource(Voltage/Hz )-415/50 with Powder coated Control Panel DOL Starter with overload protection & proper double earthing, 4 sqmm coper wiring, Fan Type- heavy duty axial/Centrifugal Blower, Vent Size (LxW)(mm) -590 x 650, Cooling media 100mm thick honeycomb cellulose pads Back Pad Size- 540x1140x100 (2 Nos), Side Pad Size (LxWxH) 410x1140x100(2 Nos), 3-Phase/ Single Speed Fan ,Noise(dBA) ≤ 70, Dimensions (LxWxH)(mm) (1600x1840x1650)±100, Controller Type Industrial grade Controller Mist Eliminator, Pre Filter, Tank Capacity (Litre)-100-150 Ltr with suitable inlet and drain system including float valve. Evaporation Efficiency- 85, Duct- Length upto 18 ft, GI 22 gauge main & 24 gauge branch, suitable volume contorl dampers & Air diffusers, flange oulet duct connections canvas flexible connector includng support and sealing etc. complete of approved makes as per the direction of engineer-in-charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail