Name of Work:- Replacement of existing Fire Detector and allied work in Old OPD Building of R urhat Govt. Medical College and Hospital under R urhat Electrical Sub-Division, PWD. (Electrical Work). Project ID: HF252640890S000.
Sl. No.
Item Description
1
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( /VDS/UL/FM/ULC approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case one independent fault isolator module for every group of addressable devices has to be provided ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Seimens/Bosch/Honeywell/GST )
2
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and (VDS/ UL/ERTL/LPCB/FM approved) approved. (Approved Make: Seimens/ Bosch/Honeywell/GST ) Note : Hooter must be Addressable by itself or by using control module.If Loop Power Hooter is not used, separate wiring from control Panel upto the the hooter will be in contractor scope without any extra cost.
3
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point (VDS/ UL/FM/ULC approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Seimens/ Bosch/Honeywell/GST )
4
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Polycab/ RR Kabel/ Havells) with 20 mm NB PVC rigid conduit pipe(Make:precision/AKG/ATUL/VIP/ Universal/BEC/Polycab) on the surface of the wall.
5
Testing & Commisioning of existing Microprocessor based Intelligent, addressable expandable and fully networkable Fire Alarm Control Panel.