| 1 | Total Amount for Supply and Erection |
| 2 | Keshiary Tr. Bay |
| 3 | 145 KV,1600 A,SF6, 3ɸ Circuit Breaker assembly with support structure complete as per technical specification |
| 4 | 132 KV, 1250 A, motor operated 3φ HCB Isolator without Earth Switch Assembly as per technical specification (Excluding Insulators) |
| 5 | 132 KV, 1250 A, motor operated 3φ Tandem Isolator without Earth Switch Assembly as per technical specification (Excluding Insulators) for Transfer Bus Isolator |
| 6 | Solid Core Insulator for above 132 KV Isolators as per technical specification |
| 7 | 132 KV, 1000-800-400/1A, 5 Core, Current Transformer as per technical specification |
| 8 | 132 KV Polymer Lightning Arrestor as per technical specification |
| 9 | 132 KV Duplex type Control & Relay Panel for HV side of 132/33 KV Transformer as per tchnical specification |
| 10 | 36 KV, 31.5 KA for 3 Sec, Indoor VCB Switchgear assembly (2500A Bus Bar current rating) with VCB & Bus Earthing Arrangement matching with existing Bus including local control system complete as per Technical Specification comprising of (Existing Make ABB, Product Type UGZS2) :- |
| 11 | Bus Section Bay |
| 12 | Transformer Bay |
| 13 | Earthing Transformer Bay |
| 14 | 33 KV, 1250A,3-phase, HCB Isolator without Earth Switch Assembly as per technical specification (Excluding Insulators) |
| 15 | Solid Core Insulator for above 33 KV Isolators |
| 16 | 33 KV Polymer Lightning Arrestor as per technical specification |
| 17 | 33 KV Simplex type Control & Relay Panel for LV side of 132/33 KV Transformer as per tchnical specification |
| 18 | 33 KV Simplex type Control & Relay Panel for Bus Coupler Bay as per Tehnical specification |
| 19 | 33 KV, Single core, 630 sq.mm., copper XLPE U.G. cable as per Technical Specification |
| 20 | Outdoor termination kit for above XLPE coper cable as per Technical Specifications at Composite Tower |
| 21 | Indoor termination kit for above XLPE coper cable as per Technical Specifications at Composite Tower |
| 22 | 33 KV, 3 core, 240 sq.mm., copper XLPE U.G. cable as per Technical Specification for ETR. |
| 23 | Outdoor termination kit for above XLPE coper cable as per Technical Specifications at Isolator / Cable support structure for ETR. |
| 24 | Indoor termination kit for above XLPE coper cable as per Technical Specifications at Indoor Gear |
| 25 | 16 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 26 | 12 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 27 | 8 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 28 | 4 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 29 | 4 Core × 4 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 30 | Multi Core, PVC, Armoured, 1.1 KV, 35 Sq mm Aluminium POWER CABLE as per technical specification and requirement |
| 31 | 2.5 \\" ALUMINIUM TUBULAR PIPE as per technical specification for 132 KV as per finished length |
| 32 | ACSR Moose Conductor as per Technical Specification |
| 33 | 132 KV Single Tension Disc Insulator for Twin Moose with tension insulator string, hardware fittings and accessories With Turn Buckle as per technical specification |
| 34 | 133 KV Single Tension Disc Insulator for Twin Moose with tension insulator string, hardware fittings and accessories without Turn Buckle as per technical specification |
| 35 | 132 KV Single Tension Disc Insulator for Single Moose with tension insulator string, hardware fittings and accessories as per technical specification |
| 36 | 132 KV Single Suspension Disc Insulator for Single Moose with insulator string hardware fittings and accessories as per Technical Specification |
| 37 | 132 KV CLAMPS & CONNECTORS including equipment connectors as per requirement and Technical Specification |
| 38 | 33 KV CLAMPS & CONNECTORS including equipment connectors as per requirement and Technical Specification |
| 39 | 132 KV Solid core BUS POST INSULATORS with accessories as per technical specification |
| 40 | 33 KV Solid core BUS POST INSULATORS with accessories as per technical specification |
| 41 | Bay Marshalling Kiosk matching with existing A.C. system |
| 42 | C.T junction box |
| 43 | Phase plate (Set of R,Y & B), |
| 44 | Cable Tray |
| 45 | 32 mm dia MS Rod for main Earth Mat, Grid, Auxiliary Earthmat, grid & Corner mesh grid and riser below ground as per technical specification considering area of the switch yard as per indicative tender drawing |
| 46 | Riser above ground (50 × 10mm GS Flat) including nuts, bolts etc. for all sub-station equipment & structure earthing as per technical specification |
| 47 | Riser (50 × 8 mm GS Flat) including nuts, bolts etc. for MOM Box, Panel, inside cable trench etc as per technical specification |
| 48 | Rod /pipe earth electrode with/without test link and any other material required to complete the earthing system (as per technical specification) |
| 49 | 132 & 33 KV Fabricated, galvanized sub-station and equipment structures matching with the existing bays complete as per approved electrical layout, assembly drawings and technical specification. |
| 50 | 5.6 / 5 grade Bolts, Nuts, spring washers, pack washers & step Bolts for 132 KV Sub station structure |
| 51 | 132/33 KV, 3ɸ, 50 MVA Transformer with Bushing CTs including Neutral C.T. in line with technical specification of Power Transformer including all accessories.(Transformer to be supplied by WBSETCL) |
| 52 | 33 KV Earthing Transformer in line with technical specification of Earthing Transformer. (Transformer to be supplied by WBSETCL) |
| 53 | 145 KV,1600 A,SF6, 3ɸ Circuit Breaker assembly with support structure complete as per technical specification |
| 54 | 132 KV, 1250 A, motor operated 3φ HCB Isolator without Earth Switch Assembly as per technical specification (Excluding Insulators) |
| 55 | 132 KV, 1250 A, motor operated 3φ Tandem Isolator without Earth Switch Assembly as per technical specification (Excluding Insulators) for Transfer Bus Isolator |
| 56 | Solid Core Insulator for above 132 KV Isolators as per technical specification |
| 57 | 132 KV, 1000-800-400/1A, 5 Core, Current Transformer as per technical specification |
| 58 | 132 KV Polymer Lightning Arrestor as per technical specification |
| 59 | 132 KV Duplex type Control & Relay Panel for HV side of 132/33 KV Transformer as per tchnical specification |
| 60 | 36 KV, 31.5 KA for 3 Sec, Indoor AIS Switchgear assembly (2500A Bus Bar current rating) with VCB & Bus Earthing Arrangement matching with existing Bus (Existing VCB Make:- ABB, Product Type UGZS2) including local control system complete as per Technical Specification comprising of :- |
| 61 | Bus Section Bay |
| 62 | Transformer Bay |
| 63 | Earthing Transformer Bay |
| 64 | 33 KV, 1250A,3-phase, HCB Isolator without Earth Switch Assembly as per technical specification (Excluding Insulators) |
| 65 | Solid Core Insulator for above 33 KV Isolators |
| 66 | 33 KV Polymer Lightning Arrestor as per technical specification |
| 67 | 33 KV Simplex type Control & Relay Panel for LV side of 132/33 KV Transformer as per tchnical specification |
| 68 | 33 KV Simplex type Control & Relay Panel for Bus Coupler Bay as per Technical specification |
| 69 | 33 KV, Single core, 630 sq.mm., copper XLPE U.G. cable as per Technical Specification |
| 70 | Lifting of existing Single core, 33 KV, 630 Sq. mm, XLPE Power Cable by excavating soil & relaying of same under earth as per technical specification |
| 71 | Outdoor termination kit for above XLPE coper cable as per Technical Specifications at Composite Tower |
| 72 | Indoor termination kit for above XLPE coper cable as per Technical Specifications at Composite Tower |
| 73 | 33 KV, 3 core, 240 sq.mm., copper XLPE U.G. cable as per Technical Specification for ETR. |
| 74 | Outdoor termination kit for above XLPE coper cable as per Technical Specifications at Isolator / Cable support structure |
| 75 | Indoor termination kit for above XLPE coper cable as per Technical Specifications at Composite Tower |
| 76 | 16 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 77 | 12 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 78 | 8 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 79 | 4 Core × 2.5 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 80 | 4 Core × 4 Sq.mm CONTROL CABLE (1.1 KV GRADE) as per technical specification and requirement |
| 81 | Multi Core, PVC, Armoured, 1.1 KV, 35 Sq mm Aluminium POWER CABLE as per technical specification and requirement |
| 82 | 2.5 \\" ALUMINIUM TUBULAR PIPE as per technical specification for 132 KV as per finished length |
| 83 | ACSR Moose Conductor as per Technical Specification |
| 84 | 132 KV Single Tension Disc Insulator for Twin Moose with tension insulator string, hardware fittings and accessories With Turn Buckle as per technical specification |
| 85 | 133 KV Single Tension Disc Insulator for Twin Moose with tension insulator string, hardware fittings and accessories without Turn Buckle as per technical specification |
| 86 | 132 KV Single Tension Disc Insulator for Single Moose with tension insulator string, hardware fittings and accessories as per technical specification |
| 87 | 132 KV Single Suspension Disc Insulator for Single Moose with insulator string hardware fittings and accessories as per Technical Specification |
| 88 | 132 KV CLAMPS & CONNECTORS including equipment connectors as per requirement and Technical Specification |
| 89 | 33 KV CLAMPS & CONNECTORS including equipment connectors as per requirement and Technical Specification |
| 90 | 132 KV Solid core BUS POST INSULATORS with accessories as per technical specification |
| 91 | 33 KV Solid core BUS POST INSULATORS with accessories as per technical specification |
| 92 | Bay Marshalling Kiosk matching with existing A.C. system |
| 93 | C.T junction box |
| 94 | Phase plate (Set of R,Y & B), |
| 95 | Cable Tray |
| 96 | 32 mm dia MS Rod for main Earth Mat, Grid, Auxiliary Earth Mat, grid & Corner mesh grid and riser below ground as per technical specification considering area of the switch yard as per indicative tender drawing |
| 97 | Riser above ground (50 × 10mm GS Flat) including nuts, bolts etc. for all sub-station equipment & structure earthing as per technical specification |
| 98 | Riser (50 × 8 mm GS Flat) including nuts, bolts etc. for MOM Box, Panel, inside cable trench etc as per technical specification |
| 99 | Rod /pipe earth electrode with/without test link and any other material required to complete the earthing system (as per technical specification) |
| 100 | 132 & 33 KV Fabricated, galvanized sub-station and equipment structures matching with the existing bays complete as per approved electrical layout, assembly drawings and technical specification. |
| 101 | Construction of drain pits below Tranformer foundation complete, includding connection of requisite pipe lines from transformer to nearby existing soak pit or BOT for efficient discharge of burnt oil to a suitable disposal unit. |
| 102 | Detailed layout including settings of peg for centre lines of equipment and structure etc. complete in all respect with labour, materials, tools & plants, incidentals etc. as stipulated in approved drawing,specification and direction of EIC. |
| 103 | Dismantling R.C.C floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75m including stacking of steel bars . |
| 104 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 105 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 106 | Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) i) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth. |
| 107 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone) including removing, spreading or stacking the soils within a lead of 75 m including necessary trimming of the sides of the trenches, levelling, dressing and ramming the bottom, bailing or pumping out water etc. filling of foundation trenches or plinth after completion of work with excavated soils in layers not exceeding 150 mm including watering, ramming etc. layer by layer complete. (This item is to be paid on the basis of volume of excavated earth) |
| 108 | Filling in foundations or plinth by medium coarse sand in layers not exceeding 150 mm as directed and consolidating same by thorough saturation with water , ramming complete including the cost of supply of sand. |
| 109 | Cement concrete M10 grade (nominal mix 1:3:6) with graded stone ballast (40 mm size), including steel/ply-wood shuttering in ground floor with all labour, materials, tools and plants, incidentals complete. Payment to be made on the basis of volume of concrete.(all complete as per IS code - 456:2000) |
| 110 | Cement concrete M 20 ( mix 1:1.5:3) with graded stone chips (20mm nominal size) including steel/ply wood shuttering , shoring , curing, testing etc. in ground floor with all labour, materials, tools and plants, incidentals complete . Payment to be paid on the basis of volume of concrete.(all complete as per IS code - 456:2000) |
| 111 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups , binders etc. initial straightening and removal of loose rust ( if necessary) , cutting to requisite length , hooking and bending to correct shape ; placing in proper position and binding with 16 gauge black annealed wire at every intersection , complete as per drawing and direction for eorks in foundation, basement and up to roof of ground floor/ upto 4M.Tor steel/Mild steel. |
| 112 | M.S structural works in columns, beams etc. with simple rolled structural members (eg. Joists angle, channel sections conforming to IS: 226, IS: 808 & SP (6) - 1964connected to one another with bracket, gussets as per design, direction of Engineer - in - Chargecomplete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816 - 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814 - 1957, haulge, hoisiting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance etc. |
| 113 | Supply & Holding down bolt with nut fitted and fixed complete and packing the hole with cement concrete or cement grouts, as directed |
| 114 | Supply & Laying of 75 mm thick cements and jhama -khoa (1:5:10) after completion of foundation work and levelling, dressing, ramming, watering etc of the ground, laying gravels/crushed stone 40mm nominal size (ungraded) in layer of 100mm over cement, sand, jhama-khoya layer in true line and level including anti weed treatment complete as per drawing specification and direction of the EIC. |
| 115 | Picking up exting gravels/crushed stone and stacking the same in sutible location, breaking of 75 mm thick cement & jhama - khoa (1:5:10) and relaying the exting gravels/crushed stone after cleaning and washing as per direction over 75 mm thick 1:5:10 cement, sand and jhama khoa layer including supplying of fresh crushed stone if required. |
| 116 | Picking up exting gravels/crushed stone and stacking the same in sutible location, breaking of 75 mm thick cement & jhama - khoa (1:5:10) and relaying the exting gravels/crushed stone within switchyard after cleaning and washing as per direction of EIC. |
| 117 | Supply ,fitting and fixing Grating in Tranformer foundation as per approved drawing and specification. |
| 118 | Supplying, spreading uniformly Gravels Over Tranformer Gratings as per approved drawing and specification. |
| 119 | Supply, fitting, fixing of glazed aluminum openable window including MS grill as per approved drawing and specification. |
| 120 | Construction of RCC Surface drain matching with the existing size and slope of drain. |
| 121 | Supplying, fitting,fixing including plate ,bolts and end stopper of 90 lbs rail on any surface. |
| 122 | Constrution of 4 M Wide Road RCC Road |
| 123 | Extension of Fire Hydrant System Complete with all accessories including requisite fire fightening pipe lines as required. |
| 124 | Construtcion of Bounadry Wall including supplying, fitting and fixing conertina fencing and barbed weir in MS Y angle as per approved drawing and specification. Rate is inclusive of earthwork excavation and filling, PCC,RCC with supply of Reinforcemnt,Shuteering,brick work, plaster and painting work complete. |
| 125 | Brick work with 1st class bricks in cement mortar (1:6) |
| 126 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 127 | Plaster with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. |
| 128 | 6 mm thick plaster with 1:4 cement mortar |
| 129 | 12 mm thick plaster with 1:6 cement mortar |
| 130 | 19 mm thick plaster with 1:6 cement mortar |
| 131 | ASF flooring with Metalic Hardener with 150 mm Skariting |
| 132 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) Two Coats |
| 133 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding , all incidental charges and the cost of primer. |
| 134 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed |
| 135 | Supplying and laying true to line and level 20 mm / 25 mm. thick precast roof tiles made of cement conc. with stone chips as per approved strength and density set in 25mm avg. thick cement morter(1:3) and filling up joint (3 mm wide) with cement sand mortar (1:1) applying cement slurry @ 1.75 kg per Sq.m back of tiles and then settting close the precast tiles, finishing up the joints with slurry already laid and finally finishing the top surface including providing 150 mm. high skirting with the same tiles flushed with the insidesurface of parapet wall,finishing the mouth of rain water pipes, curving etc. as necessary complete as per direction of the Engineer-in-charge. |
| 136 | Supplying, fitting & fixing UPVC pipes A- Type including UPVC fittings conforming to IS:13592-1992 with all necessary clamps nails,grattings including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. |
| 137 | Taking out exting steel rooling shutter and double leaf aluminium glazed door with fixed portion on sides only and refixing the same in sutable location all complete, |
| 138 | Supply, fitting & fixing of 6 mm thick MS Chequred plate with priming & painting complete Please Enable Macros to View BoQ information |