| 1 | PART-A Dismantling carefully wooden walling, flooring of ceiling and stacking dismantled materials as directed. |
| 2 | Supplying, fitting and fixing 8mm thick Laminated wooden Flooring Work conforming to EN13329:2006 with plank size not Iess than 1200mmX 190 mm (with unilin/tongue-groove locking rrangement) having 0.2mm thk top abrasive layer over a decorative layer followed by a High-ensity fibreboard (HDF) having density > 940 kg/m3 substrate core over a rasin saturated backing layer and installing through unilin or tongue- groove system (having locking strength not less than1000 kg/m) over a 2 mm thk underlayer polyurethene foam on polythene sheet 250 micron, over a smooth, flat, hard subfloor free from moisture (< 8%), grease etc. complete in all respect with requisite accessories like end profile, transition profile, reducer 'T' profile etc. wherever required and preparation of base ncluding all other incidental works as per direction & satisfaction of Engineer in charge. Cost of Laminate Floor Accessories only (Skirting,End edge, T- moulding,Reducer)shall have to be added separately, herever required. |
| 3 | Exposed False-ceiling Work --(a) Supplying, fitting & fixing High Pressure steam Cured Non Asbestos fibrecement standard ceiling board (Density > 1300Kg per Cu.m. ) of size595mm X595mm conforming IS 14862 and type B, catagory III of ISO 8336, tested as per AS-1530 Part 3 and BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a false ceiling all complete as per drawing & direction of Engineer - in- Charge.False ceiling with conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. (ii) 6mm thick Fibre Cement Standard ceiling board. |
| 4 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval anddirection of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor (ii) 6mm |
| 5 | Partition of teak veneer [1 mm] as per design fitted and fixed complete (excludingthe supporting frame work & necessary teak wood battens): In ground floor (i) 4mm thick commercial quality |
| 6 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same onParticle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. (i) Thickness of laminate 1.5mm |
| 7 | Wood work in door and window frame fitted and fixed in position completeincluding a protective coat of painting at the contact surface of the frameexluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum shouldbe correted upto three decimals). (e) Sal : Malayasian |
| 8 | Dismantling carefully wood work in posts,postplates, rafters, partition etc., sorting and stacking serviciable materials at site and removing rubbish as directed. |
| 9 | (b) Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 10 | Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) :(Two coats) ii) Luxury Quality |
| 11 | French polishing to wood work including preparing surface (ordinary gloss) (a) On new wood work |
| 12 | (b) On old French polished surface including complete removal of the oldpolish. |
| 13 | Scantling upto 50mm wide and 12mm thick (chamfering or rounding) forceiling/partion battens including fitting, fixing in position with washers, coachscrews etc. complete.:(a) Ordinary teak |
| 14 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 15 | PART-B Supply and fixing of GreenLED Ultima Square (6” x 6”) , incl cuĴing the false ceiling in reqd dimensions also the wiringand connection of the light by 1.5 sq mm cu wire complete. Out of existing total 394 nos light fittings, 149 nos damaged fittings are to be changed. i.e., 38 %Make : Philips, 10 waĴ square/ round |
| 16 | Supply TMC501 Conventional industrial baĴen PhilipsLEDtube, model no : TMC 501 P 2xT-LED 22W P3242 with2nos Mas LEDtube 1200mm 18W865 T8 I - 2100lm includingnecessary connection.Out of existing total 31 nos Tube fittings, 12 nos damaged fittings are to be changed. i.e., 39 % |
| 17 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. akingearthing attachment, painting and mending good damages to building works(d) 12 Module |
| 18 | Approved EE/BMC on 21.05.25. Supply,fitting,fixing of 1.50 HP 220 voit KSB make Submersible motor pump including control panel Box and 40.0 mtr. Finolex fit cable and other fittings. |
| 19 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required Out of existing total 425 nos 6A switch, 80 nos damaged 6A switch are to be changed. i.e., 19 % |
| 20 | Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required Out of existing total 25 nos 16A switch, 09 nos damaged 6A switch are to be changed. i.e., 36 % |
| 21 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.Out of existing total 25 nos 16A socket 09 nos damaged 6A socket are to be changed. i.e., 36 % |
| 22 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (h) 3 x 56/0.3 (4 sqmm) |
| 23 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (h) 3 x 36/0.3 (2.5 sqmm) |
| 24 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire(Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed onModular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish [PVC asingcapping on surface and Switch board concealed] 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (g)Average run 12 mtr |
| 25 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 10 A(SP) Out of existing total 48 nos 10A (SP) 16 nos damaged 10A (SP)are to be changed. i.e., 33% Make: Legrand, Schneider, Crabtree, Siemens. |
| 26 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 20A (DP) Make: Legrand, Schneider, Crabtree, Seimens Out of existing total 12 nos 20A (DP) 06 nos damaged 20A (DP)are to be changed. i.e., 50 % |
| 27 | Add GST@18% on Sl. No. 1 to 26 |
| 28 | Add labour cess @1% on Sl. No. 1 to 27 Please Enable Macros to View BoQ information |