| 1 | PWD ( W.B ), BUILDING WORKS, Page-10, Item-2 Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 2 | PWD ( W.B ), BUILDING WORKS, Page-198, Item-1 Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 3 | PWD ( W.B ), BUILDING WORKS, Page-10, Item-2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 4 | PWD ( W.B ), BUILDING WORKS, Page-42, Item-36 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) |
| 5 | PWD ( W.B ), BUILDING WORKS, Page-22, Item-35 B (II) Cement concrete with 30 mm down graded shingles excluding shuttering.) (B) With N.B. Variety stone metal. In ground floor (a) 1:3:6 proportion |
| 6 | PWD(WB), BUILDING WORKS, Page-26, Item-10 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 7 | PWD(WB), BUILDING WORKS, Page-44, Item-40 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. |
| 8 | PWD(WB), BUILDING WORKS, Page-189, Item-1 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor) .[Excluding cost of chipping over concrete surface] 20 MM THK |
| 9 | PWD(WB), BUILDING WORKS, Page-189, Item-1 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor) .[Excluding cost of chipping over concrete surface] 15 MM THK |
| 10 | PWD(WB), BUILDING WORKS, Page-114, Item-1 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should becorreted upto three decimals). |
| 11 | PWD(WB), BUILDING WORKS, Page-117, Item-1 Z-batten shutters of door and window as per design havings tongued and groovehalf lap jointed as per direction of the Engineer-in-Charge including fitting and fixing shutter in position, but excluding the cost of hinges and other fittings inground floor. |
| 12 | PWD(WB), BUILDING WORKS, Page-104, Item-13 a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. |
| 13 | PWD(WB), BUILDING WORKS, Page-200, Item-1 a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 14 | (b) Priming one coat on timber or plastered surface with synthetic oilbound primer of approved quality including smoothening surfaces by sandpapering etc. |
| 15 | PWD(WB), BUILDING WORKS, Page-200, Item-2 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : |
| 16 | PWD(WB), BUILDING WORKS, Page-200, Item-2 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : |
| 17 | PWD(WB), BUILDING WORKS, Page-48, Item-6 M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. |
| 18 | PWD(WB), BUILDING WORKS, Page-81, Item-9 Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor) |
| 19 | PWD(WB), BUILDING WORKS, Page-81, Item-10 Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping) |
| 20 | PWD(WB), BUILDING WORKS, Page-192, Item-15 Neat cement punning about 1.5mm thick in wall,dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
| 21 | Add Electrification @ 5 % |
| 22 | Add:- GST @ 18% |
| 23 | Add:- Labour Welfare Cess @ 1% Please Enable Macros to View BoQ information |