| 1 | Maintenance work |
| 2 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 3 | OD9263/2025-2026: Engaging ordinary mazdoor assisting heavy load mazdoor in applying oil and grease for shutters and ropes as per direction of the departmental officers at site. |
| 4 | OD9262/2025-2026: Engaging heavy load mazdoor for applying oil and grease to shutters and ropes as per the direction of the departmental officers at site. |
| 5 | OD9267/2025-2026:Supplying at site of work best quality hydraulic lubricating oil for gears etc. as per direction of the departmental officers at site. |
| 6 | OD9264/2025-2026:Supplying at site of work best quality cardium compound for ropes of shutters as per direction of the departmental officers at site |
| 7 | OD9265/2025-2026:Supplying at site of work first quality bearing grease for regulator shutters,drum,plumber block etc. as per direction of the departmental officers at site |
| 8 | OD9266/2025-2026:Engaging heavy man mazdoor for operating the shutter closing and opening as per the direction of the departmental officers at site |
| 9 | Reconstruction of damaged foot path bridge |
| 10 | 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 11 | 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 12 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 16 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 17 | 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes |
| 18 | 6.8:Brick work 7 cm thick with common burnt clay F.P.S. (non modular ) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand ) in superstructure above plinth level and upto floor five level. |
| 19 | 13.2.1:15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand) |
| 20 | Fixing Warning Board |
| 21 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 22 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 23 | 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 24 | OD34005/2025-2026:Supplying and fixing fabricated warning board of size 75x45 cm with post, Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, welding fixing in position and finishing with approved steel primer, yellow color painting, etc. And printed letters in Malayalam with black colour, for relevant information and fixing it including cost and conveyance of all materials and all labour charges etc. complete as per the directions of the departmental officers at site Please Enable Macros to View BoQ information |