| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | DISMANTILING AND DEMOLISHING WORKS |
| 3 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 4 | SITE CLEARENCE |
| 5 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared |
| 6 | EARTH WORK EXCAVATION WORKS |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 9 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil |
| 10 | Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL Anti termite treatment and creating a chemical barrier on top surface of plinth filling, junctions of inside walls and floors, soil along external perimetre using the chemical lmidacloprid emulsifiable (IS 6313 (part2:2013) 30.5% SC mixed with water in 1:499 ratio. The emulsion is spread at 5litre/sqm on top surface of plinth filling, at 1litre/linear metre along the junction of wall and floor and at 2.25litres/linear metre of the plinth wall as per the specifications and directions. (Note: plinth area only shall be measured forpayment) |
| 11 | PCC WORKS |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work above plinth level up to floor five level1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 14 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work above plinth level to floor five level :1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 16 | RCC WORK |
| 17 | Providing and laying in position machine batched and machine mixed design mix M 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.(Note-Minimum cement content is 350kg/cum and no payment shall be made for extra cement howeverc ontractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level. Concrete of M30 grade with minimum cement content of 350kg/cum |
| 18 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 19 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 21 | Providing and laying in position machine batched and machine mixed design mix M 30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note-Minimum cement content is 350kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).All work above plinthlevel upto floor V level. Concrete of M30 grade with minimum cement content of 350kg/cum |
| 22 | FORM WORK |
| 23 | Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 24 | Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 25 | Centering and shuttering including strutting, etc. and removal of form for:Walls (anythickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 26 | Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 27 | Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 28 | Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) |
| 29 | Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 30 | Centering and shuttering including strutting, etc. and removal of form for:Weathershade, Chajjas, corbels etc., including edges |
| 31 | STONE WORKS |
| 32 | DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site |
| 33 | MASONRY WORKS |
| 34 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 35 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. |
| 36 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cmor nearest available size confirming to IS 2185 part I of 1979 for super structure up tofloor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) includingcost of scaffolding complete |
| 37 | Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 38 | PLASTERING |
| 39 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 40 | 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 41 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 42 | 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) |
| 43 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self – centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge . (Material shall confirm to ASTM 6063).Floor Joint of 150 mm gap. |
| 44 | Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 100 mm gap. |
| 45 | STEEL WORK |
| 46 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 47 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes |
| 48 | Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approvedsteel primer all complete. |
| 49 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 50 | Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washersetc. complete |
| 51 | Providing and fixing polycarbonate glass sheet (size, color and design as approved byEngineer-in-charge) 3mm. The sheet shall be fixed using self drilling/self tappingscrews of size (2440 mm × 1220 mm) with EPDM seal, complete upto any pitch inhorizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required. |
| 52 | DOORS & WINDOWS |
| 53 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood |
| 54 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of I st class hard woodand well matched teak 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters.35 mm thick Fixing with hinges of required size andnecessary screws(Note: Hinges and necessary screws hall be paid separately) |
| 55 | Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressedbutt hinges bright finished of required size with necessary screws. ( Shutter area to bemeasured) |
| 56 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 57 | Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 58 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm |
| 59 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm |
| 60 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm |
| 61 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 62 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pairof handles of approved quality for aluminium door, with necessary screws etccomplete as per direction of Engineer- in- charge. |
| 63 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mmthick and shall be filled with suitable wooden block in all the three legs. The frameshall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. |
| 64 | Providing and fixing to existing door frames.30 mm thick Glas Fibre ReinforcedPlastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant grade unsaturated polyester resin, moulded to3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame andsuitable blocks of seasoned wood inside at required places for fixing of fittings, castmonolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames. |
| 65 | Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the endby end locks, mounted on specially designed pipe shaft with brackets, side guides andarrangements for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wire springsmanufactured from high tensile steel wire of adequate strength conforming to IS:4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25mm M.S. laths with 1.25 mm thick top cover |
| 66 | Providing and fixing ball bearing for rolling shutters. |
| 67 | Extra for providing mechanical device chain and crank operation for operating rollingshuttersExceeding 10.00 sqm and upto 16.80 sqm in the area |
| 68 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (costof glass excluded ) (overall area of door shutter to be measured):Rectangular orsquare |
| 69 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approvedbrand and manufacture, including providing and fixing top & bottom pivot & doubleacting hydraulic floor spring type fixing arrangement and making necessary holes etc.for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc to be paid separately) |
| 70 | Supplying and fixing of 2mm thick lead sheet on masonry, wooden, RCC surfaces,etc. using specially treated screws. The lead sheet should be covered with 1 mm thicklaminated plywood of 8mm thick using necessary adhesive, treated screws, etc. Thework should meet the AERB standards, Plated on necessary areas and up o necessaryheight as per the design or the direction of the engineer in charge. Also the corners,joints are covered with lead strips of necessary width, The rate inclusive of labour,materials, the necessary frame work, strips, studs, adhesives, shifting charges, etc.Area 6*3m = 18 Sqm, Add 5% Wastage= 18.9 Sqm |
| 71 | Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angleiron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittingscomplete, including applying a priming coat of approved steel primer.Using M.S.angels 40x40x6 mm for diagonal braces |
| 72 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixingof float glass panes with glazing clips and special metal-sash putty of approved make,or metal beading with screws, (only steel windows, glass panes cut to size and glazingclips or metal beading with screws, shall be supplied by department free ofcost.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand: 6 graded stone aggregate 20mm nominal size). |
| 73 | Supply of SS corner lock for toughened glass door of 12mm thick with weight upto200kg |
| 74 | Supply of stainless steel handle for toughened glass door, H- type of size 450 mm and25 mm dia with satin finish of reputed make . |
| 75 | Providing and installing in position PROPRIETARY FIRE DOORS of approvedmake Tata Pravesh or equivalent with Metal frame filled with Rockwool. The shuttersshall be of Pressed Metal shutter with or without Vision panels finished withapproved Powder coated as per the detail drawings & manufacturers specifications.The fire ratings shall be as called for and confirming to BIS standards as per the detaildrawings & manufacturers specifications. This includes providing and fixing all brushfinished iron mongery like locks, handles, tower bolts, door closer etc of Geze/Dormaas indicated in the detail drawing, and confirming to BIS standards as per the detaildrawings & manufacturers specifications. This includes providing and fixing all brushfinished iron mongery like locks, handles, tower bolts, door closer etc of Geze/Dormaas indicated in the detail drawing. Typical Uninsulated Door specifications 120Mins. Un Insulated fire door as per IS 3614 - Powder coated Pressed galvanizedsteel confirming to IS 277 with the following specification. Recommended fire doorshall be tested to IS 3614 part 2/ISO 834-1 Part 1/BS 476 Part 20 & 22,CBRI/Spectra, for maximum rating of 120mins, in latched /unlatched condition (ifused with deadbolts and pull handles). Labelled fire doors shall be with fire ratedhardware and vision panel (if any) all as a complete assembly. Manufacturer testcertificate shall cover sizes of all doors supplied, deviation in sheet thickness otherthan what is mentioned in the BOQ are not allowed. Door frame must be single rebategrooved profile of size 143 x 58mm made out of 1.60mm (16gauge) minimum thickgalvanized steel sheet. Frames shall be mitered only. Frames shall be field assembledwith self tabs. Bolted & butted joints are not acceptable. All provision should bemortised, drilled and tapped for receiving appropriate hardware. Frames should beprovided with back plate bracket and anchor fasteners for installation on a finishedplastered masonry wall opening. Frame should be filled with Mineral wool/ Fire ratedPUF as recommended by the manufacturer or engineer in charge. Door leaf shall beminimum 46mm thick fully flush double skin door, Un-insulated with or withoutvision lite. Door leaf shallbe manufactured from 1.20mm (18guage) minimum thick galvanised steel sheet. Theinternal construction of the door should be rigid reinforcement pads for receivingappropriate hardware of make Geze/Dorma. The infill material shall be resin bondedhoneycomb core. The edges should be interlocked with a bending radius of 1.4mm,without any tack welding on edges. Vision lite wherever applicable should be 6mmclear borosilicate fire rated glass of make Saint Gobain/ Schott as per manufacturersrecommendation with a clip-on arrangement.Door and frames shall be finished PurePolyester Powder coated and shall have passed minimum 500 hours of salt spray test.Rate shall include supply and installation of frame and shutter as a complete assemblyincluding hardware. Fire Door of size1*2.1M with Metal frame of size 143x58mmwith pressed metal single leaf shutter of size 46mm finished with Powder coated ofapproved colour and shade as per the Project Consultants approval with 2 Hours Firerating. Rate of providing ironmongery as mentioned/recommended bymanufacturer/engineer in charge. All fittings are of Brushed steel finish of Geze orapproved make as per detail drawing. Ball bearing butt hinge, SS304, of size 100 x 75x 3mm with screws in SSS, Panic Hardware, Door Closer, SSS finish, Vision Panel. |
| 76 | Providing and installing in position PROPRIETARY FIRE DOORS of approvedmake Tata Pravesh or equivalent with Metal frame filled with Rockwool. The shuttersshall be of Pressed Metal shutter with or without Vision panels finished withapproved Powder coated as per the detail drawings & manufacturers specifications.The fire ratings shall be as called for and confirming to BIS standards as per the detaildrawings & manufacturers specifications. This includes providing and fixing all brushfinished iron mongery like locks, handles, tower bolts, door closer etc of Geze/Dormaas indicated in the detail drawing, and confirming to BIS standards as per the detaildrawings & manufacturers specifications. This includes providing and fixing all brushfinished iron mongery like locks, handles, tower bolts, door closer etc of Geze/Dormaas indicated in the detail drawing. Typical Uninsulated Door specifications 120Mins. Un Insulated fire door as per IS 3614 - Powder coated Pressed galvanizedsteel confirming to IS 277 with the following specification. Recommended fire doorshall be tested to IS 3614 part 2/ISO 834-1 Part 1/BS 476 Part 20 & 22,CBRI/Spectra, for maximum rating of 120mins, in latched /unlatched condition (ifused with deadbolts and pull handles). Labelled fire doors shall be with fire ratedhardware and vision panel (if any) all as a complete assembly. Manufacturer testcertificate shall cover sizes of all doors supplied, deviation in sheet thickness otherthan what is mentioned in the BOQ are not allowed. Door frame must be single rebategrooved profile of size 143 x 58mm made out of 1.60mm (16gauge) minimum thickgalvanized steel sheet. Frames shall be mitered only. Frames shall be field assembledwith self tabs. Bolted & butted joints are not acceptable. All provision should bemortised, drilled and tapped for receiving appropriate hardware. Frames should beprovided with back plate bracket and anchor fasteners for installation on a finishedplastered masonry wall opening. Frame should be filled with Mineral wool/ Fire ratedPUF as recommended by the manufacturer or engineer in charge. Door leaf shall beminimum 46mm thick fully flush double skin door, Un-insulated with or withoutvision lite. Door leaf shallbe manufactured from 1.20mm (18guage) minimum thick galvanised steel sheet. Theinternal construction of the door should be rigid reinforcement pads for receivingappropriate hardware of make Geze/Dorma. The infill material shall be resin bondedhoneycomb core. The edges should be interlocked with a bending radius of 1.4mm,without any tack welding on edges. Vision lite wherever applicable should be 6mmclear borosilicate fire rated glass of make Saint Gobain/ Schott as per manufacturersrecommendation with a clip-on arrangement.Door and frames shall be finished PurePolyester Powder coated and shall have passed minimum 500 hours of salt spray test.Rate shall include supply and installation of frame and shutter as a complete assemblyincluding hardware. Fire Door of size 1.2X2.1m with Metal frame of size 143x58mmwith pressed metal single leaf shutter of size 46mm finished with Powder coated ofapproved colour and shade as per the Project Consultants approval with 2 Hours Firerating. Rate of providing ironmongery as mentioned/recommended bymanufacturer/engineer in charge. All fittings are of Brushed steel finish of Geze orapproved make as per detail drawing. Ball bearing butt hinge, SS304, of size 100 x 75x 3mm with screws in SSS, Panic Hardware, Door Closer, SSS finish, Vision Panel. |
| 77 | Providing and installing in position PROPRIETARY FIRE DOORS of approvedmake Tata Pravesh or equivalent with Metal frame filled with Rockwool. The shuttersshall be of Pressed Metal shutter with or without Vision panels finished withapproved Powder coated as per the detail drawings & manufacturers specifications.The fire ratings shall be as called for and confirming to BIS standards as per the detail drawings & manufacturers specifications. This includes providing and fixing all brushfinished iron mongery like locks, handles, tower bolts, door closer etc of Geze/Dormaas indicated in the detail drawing, and confirming to BIS standards as per the detaildrawings & manufacturers specifications. This includes providing and fixing all brushfinished iron mongery like locks, handles, tower bolts, door closer etc of Geze/Dormaas indicated in the detail drawing. Typical Uninsulated Door specifications 120Mins. Un Insulated fire door as per IS 3614 - Powder coated Pressed galvanizedsteel confirming to IS 277 with the following specification. Recommended fire doorshall be tested to IS 3614 part 2/ISO 834-1 Part 1/BS 476 Part 20 & 22,CBRI/Spectra, for maximum rating of 120mins, in latched /unlatched condition (ifused with deadbolts and pull handles). Labelled fire doors shall be with fire ratedhardware and vision panel (if any) all as a complete assembly. Manufacturer testcertificate shall cover sizes of all doors supplied, deviation in sheet thickness otherthan what is mentioned in the BOQ are not allowed. Door frame must be single rebategrooved profile of size 143 x 58mm made out of 1.60mm (16gauge) minimum thickgalvanized steel sheet. Frames shall be mitered only. Frames shall be field assembledwith self tabs. Bolted & butted joints are not acceptable. All provision should bemortised, drilled and tapped for receiving appropriate hardware. Frames should beprovided with back plate bracket and anchor fasteners for installation on a finishedplastered masonry wall opening. Frame should be filled with Mineral wool/ Fire ratedPUF as recommended by the manufacturer or engineer in charge. Door leaf shall beminimum 46mm thick fully flush double skin door, Un-insulated with or withoutvision lite. Door leaf shallbe manufactured from 1.20mm (18guage) minimum thick galvanised steel sheet. Theinternal construction of the door should be rigid reinforcement pads for receivingappropriate hardware of make Geze/Dorma. The infill material shall be resin bondedhoneycomb core. The edges should be interlocked with a bending radius of 1.4mm,without any tack welding on edges. Vision lite wherever applicable should be 6mmclear borosilicate fire rated glass of make Saint Gobain/ Schott as per manufacturersrecommendation with a clip-on arrangement.Door and frames shall be finished PurePolyester Powder coated and shall have passed minimum 500 hours of salt spray test.Rate shall include supply and installation of frame and shutter as a complete assemblyincluding hardware. Fire Door of size 1.8*2.1M with Metal frame of size 143x58mmwith pressed metal single leaf shutter of size 46mm finished with Powder coated ofapproved colour and shade as per the Project Consultants approval with 2 Hours Firerating. Rate of providing ironmongery as mentioned/recommended bymanufacturer/engineer in charge. All fittings are of Brushed steel finish of Geze orapproved make as per detail drawing. Ball bearing butt hinge, SS304, of size 100 x 75x 3mm with screws in SSS, Panic Hardware, Door Closer, SSS finish, Vision Panel. |
| 78 | ALUMINIUM WORKS |
| 79 | Providing and fixing factory made uPVC white colour sliding glazed window upto1.50 m in height dimension comprising of uPVC multi-chambered frame with in-builtroller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), appropriate dimension of uPVC extrudedglazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy(white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steel screws etc. Profile of frame &sash shall be mitred cut and fusion welded at all corners, including drilling of holesfor fixing hardware's and drainage of water etc. After fixing frame the gap betweenframe and adjacent finished wall shall be filled with weather proof silicon sealentover backer rod of required size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire meshand silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimensioni.e. in depth & width of profile shall be acceptable.Two track two panels slidingwindow made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both havingwall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension.(Area of window upto 1.75 sqm) |
| 80 | Providing and fixing factory made uPVC white colour sliding glazed window upto1.50 m in height dimension comprising of uPVC multi-chambered frame with in-builtroller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thickgalvanized mild steel section made from roll forming process of required length(shape & size according to uPVC profile), appropriate dimension of uPVC extrudedglazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy(white powder coated) touch locks with hook, zinc alloy body with single nylonrollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steel screws etc. Profile of frame &sash shall be mitred cut and fusion welded at all corners, including drilling of holesfor fixing hardware's and drainage of water etc. After fixing frame the gap betweenframe and adjacent finished wall shall be filled with weather proof silicon sealentover backer rod of required size and of approved quality, all complete as per approveddrawing & direction of Engineer-in-Charge. (Single / double glass panes, wire meshand silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimensioni.e. in depth & width of profile shall be acceptable.Two track two panels slidingwindow made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wallthickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead ofappropriate dimension . (Area of window above 1.75 sqm upto 2.50 sqm). |
| 81 | Providing and fixing casement handle made of zinc alloyed (white powder coated) foruPVC casement window with necessary screws etc. complete. |
| 82 | Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 83 | Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 84 | For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 85 | Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 86 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides |
| 87 | Providing and fixing frosted film in the fixed glass etc. Complete as per the directionof departmental officers |
| 88 | Providing and fixing glazing in door, window, ventilator shutters and partitions etc.with EPDM rubber /neoprene gasket etc. complete as per the architectural drawingsand the directions of engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item): toughened glass of 6 mm thickness. |
| 89 | Providing and fixing radiation shielding lead glass of size 1200 × 600 mm, 10 mm thick, having 2.1 mm Pb equivalence, duly tested and certified for use in X-rayrooms, complete with factory-fabricated hardwood frame internally lined with 2.1mm thick lead sheet to ensure radiation continuity. The work shall include providinga minimum 25 mm lead overlap at all joints with the adjoining lead lining, neoprenegasket packing, necessary fasteners, sealing, finishing with approved polish/paint, andcomplete installation as per directions of the Engineer-in-charge. |
| 90 | TILE WORKS |
| 91 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm infloors, jointed with neat cement slurry mixed with pigment to match the shade of thetiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement |
| 92 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 93 | Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thickbed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 94 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm |
| 95 | Extra for providing opening or required size & shape for wash basin/kitchen sink inkitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete. |
| 96 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 97 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase ofappropriate width with chase cutter and embedding the stone in the chase with epoxygrout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 6 mm nominal size) as per direction of Engineer-in Charge and finishedsmooth.Granite Stone of approved shade |
| 98 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 99 | Providing and laying C.C pavement of mix M-25 with ready mixed concrete frombatching plant. The ready mixed concrete shall be laid and finished with screed boardvibrator, vacuum dewatering process and finally finished by floating brooming withwire brush etc. complete as per specifications and directions of Engineer-in-charge (The panel shuttering work shall be paid for separately)(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/lesscement used as per design mix is payable/ recoverable separately). |
| 100 | Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 101 | Supply and installation of Fire stop mortar system with minimum 2 hours fire ratingwhen tested in accordance with UL 1479 standards, for openings in floors or slabsafter passing service lines like Metal Pipes. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-257:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Timehistory method and VERTEQII for seismic zone 4. The productshall be age tested as per Dafstb and DIBT standards. The product shall carry testcertificate for mold resistance rating of 0 as determined by ASTM G21-96. Theproduct shall be UL listed & classified and shall bear the UL approval logo on thepacking. .Engineering Judgements (EJs) should be used for situations where a testedsystem is not available. The application to be executed by manufacturer approvedfirestop contractor.. Assumed 15% Penetrants Occupancy. |
| 102 | Supply and installation of Fire stop mortar system with minimum 2 hours fire ratingwhen tested in accordance with UL 1479 standards, for openings in floors or slabsafter passing service lines like Metal Pipes. The mortar shall be a light weightcementitious product and shall carry test certificate in accordance with IEC 60068-257:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Timehistory method and VERTEQII for seismic zone 4. The productshall be age tested as per Dafstb and DIBT standards. The product shall carry testcertificate for mold resistance rating of 0 as determined by ASTM G21-96. Theproduct shall be UL listed & classified and shall bear the UL approval logo on thepacking. .Engineering Judgements (EJs) should be used for situations where a testedsystem is not available. The application to be executed by manufacturer approvedfirestop contractor.. Assumed 15% Penetrants Occupancy |
| 103 | Supply and installation of Fire Barrier mortar with minimum 2 (two) hours fire ratingwhen tested in accordance with UL 1479 standards, for fire rated vertical openings infloors or slabs and floors made of concrete, masonry,metal, gypsum partition, afterpassing service lines like Cable,Cable trays, Bus Duct or Metal pipes. The mortarshall be a light weight cementitious product and shall carry test certificate inaccordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57:Test for Vibration-Time-history method and VERTEQII for seismic zone 4.Expanding fire stop foam with minimum 2 hours fire rating when tested inaccordance with UL 1479 standards, shall be used to seal areas that are highly denseor are not accessible and cannot be sealed with fire stop mortar properly.Theexpanding foam shall expand minimum seven times its volumeto fill the cavity at the time of dispensing the material and shall fully cure within twominutes after dispensing. The expanding foam shall also be repenetratable. Theproducts shall be age tested as per Dafstb and DIBT standards. The products shallcarry test certificate for mold resistance rating of as determined by ASTM G21-96.The products shall be UL listed & classified and shall bear the UL approval logo onthe packing.Engineering Judgements (EJs) should be used for situations where atested system is not available. The application to be executed by manufacturerapproved firestop contractor. |
| 104 | Supply and installation of Fire stop mortar system withminimum 2 hours fire rating when tested in accordance with UL 1479 standardsfor horizontal openings in floor or slabs after passing plastic or metal pipes. The mortar shall be a light weight cementitious products and shall carry testcertificate in accordance with IEC 60068-2-57:1999-11 (EnvironmentalTesting)as per Part 2-57: Test for vibration- Time -history method andVERTEQII for seismic zone 4 with fire intumescent sealants to provideminimum 2 hours fire rating when tested in accordance with UL1479 standards.The products shall be age tested as per Dafstb and DIBT standards. The productsshall carry test certificate for mold resistance rating of 0 as determined by ASTMG21-96. The products shall be UL listed and classified and shall bear the ULapproval logo on the packing. The installations shall be done by manufacturecertified contractor in accordance with the manufacture guidelins. The contractorneeds to provide complete installation report through software for inspectionpurpose. Engineering Judgements(EJs) should be used for situations where atested system is not available. |
| 105 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete |
| 106 | GLAZING AND CLADDING WORKS |
| 107 | Design supply & installation of suspended Spider Glazing system designed towithstand the wind pressure as per IS 875 (Part-III). The Suspended System held withSpider Fittings of SS-316 Grade Steel of approved manufacturer with glass panelhaving 12 mm thick clear toughened glass held together with SS- 316 Grade Stainlesssteel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass finsand glass panel assembly shall be connected to Slab/beams by means of SS- 316Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of50x25x2mm using fastener & anchor bolts, non staining weather sealants of approvedmake, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, allcomplete to perform as per specification and approved drawings. The completesystem to be designed to accommodate thermal expansion & seismic movements etc.The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channelof the assembly to be filled with non staining weather sealant, so as to make the entiresystem fully water proof & dust proof. The rate shall include all design, Engineeringand shop drawing including approval from structural designer, labour, T&P,scaffolding, other incidental charges including wastage, enabling temporary servicesall fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channellaminated glass etc. all complete. For the purpose of payment, actual elevation area ofGlazing including thickness of joints and the portion of Glass panel inside the SSchannel shall be measured. |
| 108 | FALSE CEILING |
| 109 | Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other endof angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommended jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also includingthe cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as per drawings, specificationand direction of the Engineer in Charge but excluding the cost of painting with:12.5mm thick tapered edge gypsum moisture resistant board |
| 110 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm intrue horizontal level, suspended on inter locking metal grid of hot dipped galvanizedsteel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting ofmain \\"T\\" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to centerand cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mmlong spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mmthick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to formgrids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceilingtiles of approved texture in the grid including, required cutting/making, opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\"runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as perspecifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fullyPerforated Gypsum Board tile made from plaster board having glass fibre conformingto IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mmc/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of0.79, with 50 mm resin bonded glass wool backing. |
| 111 | CURTAIN WORKS |
| 112 | Supplying and laying polyester, washable and stain free cloth(Bio-Active fabricwashable germ free suitable for sterile area) curtain curtain system with maximumcurtain curtain cloth height 230 cm(top 30 cm white colour net and 200cm light bluecolor as per approval) stitching with stifiner tape, pleats, ironing and laying aroundeach bed using PVC runner with hooks & stopper for hanging/sliding etc. as perthe direction of engineer in charge including conveyance to site, laying in line andlevel, sealing all cutting in false ceiling with powder coated MS cup, all leads and liftsincluding all labour charges etc. complete. (unpleated length of the clothmeasurement will be considered for payment also the bottom and top foldings will notbe considered in cloth measurement)/ supplying and fixing powder coated 20mm dia.GI round tube hanging support of required length(app. length 1.10m) one end fixingfrom slab by using 6mm dia expansion bolt at a distance not more than 2m, c/c downend fixed to powder coated aluminium channel frame 45 x 20mm x 1mm thicksection by using SS screw as per the direction of engineer in charge includingconveyance. |
| 113 | Providing and fixing of vertical/roller blinds width 100 mm regular quantity madefrom 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure completeopaquety with zero light transmittance, having suitable coating on exterior, includingall fixtures and fittings complete in all respect as per design and instruction ofEngineer in-charge and as per site conditions. The colour will be approved by thecompetent authority.<br> and inclusive of all labour charges. |
| 114 | PAINTING |
| 115 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete |
| 116 | Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 117 | Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. |
| 118 | Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 119 | Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm |
| 120 | Painting with synthetic enamel paint of approved brand and manufacture to give aneven shade:Two or more coats on new work |
| 121 | Finishing walls with water proofing cement paint of required shade:New work (Twoor more coats applied @ 3.84 kg/10 sqm) |
| 122 | PLUMBING AND SANITARY FITTINGS |
| 123 | Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid |
| 124 | Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with white PVC automatic flushing cistern, with fittings, standardsize C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) withwaste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P.brass, including painting of fittings and cutting and making good the walls and floorswherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern |
| 125 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats withC.P. brass screws and washers complete. |
| 126 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approvedquality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadthweighing not less than 45 gms |
| 127 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and112 mm distance from wall of standard shape with bracket of the same materials withsnap fittings of approved quality and colour, weighing not less than 105 gms |
| 128 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms |
| 129 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge |
| 130 | Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 131 | Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:20 mm nominal bore |
| 132 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 133 | Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia |
| 134 | Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2 |
| 135 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10Kgf/cm2 - External work - Exposed on wall |
| 136 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 137 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal dia pipes |
| 138 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.20 mm nominal dia pipes |
| 139 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes& fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction ofEngineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.32 mm nominal dia pipes |
| 140 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 141 | Providing and fixing PTMT extension nipple for water thank pipe, fittings ofapproved quality and colour .20 mm nominal bore, weighing not less than 40 gms |
| 142 | Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design. |
| 143 | Providing and fixing of wall mounted foot operated 2 way handwash sink with backsplash (S.S 304 grade top 1.5mm thick and covering 1mm), of overall size 1500mm,600mm, 950(+500) mm. The rate includes material, carriage, shifting up to 5th floor,placing, labour charges, etc. including tap, . the placement as per the direction ofengineer in-charge |
| 144 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 263 gms |
| 145 | Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore |
| 146 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulatedas per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimumcross section as 23 mm x 25 mm and over all minimum length 263 mm and width as165 mm with minimum 112 mm space between protruded legs having 2 mm tread ontop surface by ribbing or chequering besides necessary and adequate anchoringprojections on tail length on 138 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and havingmanufactures permanent identification mark to be visible even after fixing includingfixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design |
| 147 | Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of requiredshape and approved quality.L D - 2.5Rectangular shape 600x450 mm internal dimensions |
| 148 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15mm nominal dia pipes |
| 149 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25mm nominal dia pipes |
| 150 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includesjointing of pipes & fittings with one step CPVC solvent cement and testing of jointscomplete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32mm nominal dia pipes |
| 151 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Surgeontype wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps withelbow including operated levers |
| 152 | Flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia withlength not less than 700 mm i/c PVC waste fittings. |
| 153 | Providing and fixing PVC pipes includings jointing of pipes with one step pvc solventcement, trenching , refilling & testing of joints complete as per direction of Engineerin Charge. 150 mm dia 6 Kgf/cm2 |
| 154 | Supplying and placing of 5000 Litre 1mm thick stainless steel water tank of 1750mmdia , 2600mm height, Stainless steel mounted stand around 180kg and grade ofASTM A240 gr.304/ SS316 BA/2B as per the direction of Engineer in-charge. Therate inclusive of all the transportation, Steel stand support, loading and unloadingcharges, fixing charges, Labour charges, etc. Nothing shall be additionally paid in thisitem. |
| 155 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 150 mm dia6Kgf/cm2 - External work- Exposed on wall |
| 156 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00spacing. This includes jointing of pipes & fittings with one step PVC solvent cementand testing of joints complete as per direction of Engineer-in-Charge Concealedwork, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2 |
| 157 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 |
| 158 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating |
| 159 | Providing and fixing Single tap Scrub sink - SS 304 size L30 x W16 x D15"with including supply of Elbow tap and dispenser complete as per the direction ofengineer in charge. |
| 160 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 161 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 162 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 163 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 164 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 165 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 166 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm Dia Y |
| 167 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm Dia Y |
| 168 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm Vent cowl |
| 169 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Door Tee |
| 170 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Tee |
| 171 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Elbow |
| 172 | Providing and fixing PPR Unions- PPR Union 150mm |
| 173 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Bend |
| 174 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 150 mm dia Door Bend |
| 175 | Providing and fixing PPR Unions- PPR Union 110mm |
| 176 | Providing and fixing a Disabled Toilet complete set comprising white wall-mounted Matrix set (WB 46X36 with one pair mounting brackets, EWC and cistern completewith all necessary fittings, seat cover, one number hinged rail 76cm and 4 nos of grabrails 60cm) and accessories. The item shall include providing and fixing all brackets,expansion sleeves, stainless steel/brass bolts, screws, nuts, washers, etc., includingcutting and making good the walls wherever required, complete in all respects as permanufacturer specifications and as directed by the Engineer-in-Charge. |
| 177 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mmSand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, includingflush pipe, manually controlled device (handle lever) conforming to IS : 7231, withall fittings and fixtures complete, including cutting and making good the walls andfloors wherever require:Stainless Steel AISI-304 (18/8) orissa pattern W.C. pan ofsize 585x 480 with flush pipe and integrated type foot rests |
| 178 | Constructing brick masonry chamber for underground C.I. inpection chamber andbends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover withframe (light duty) 455x610 mm internal dimensions, total weight of cover with frameto be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C topslab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mmnominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stoneaggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement onwalls and bed concrete etc. complete as per standard design:Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or twoinlets:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 179 | Providing and fixing P-trap for water closet of approved make water seal, includingjointing with pipe using necessary rubber gasket / solvent cement, cutting whereverrequired, complete in all directed by the Engineer-in-Charge. |
| 180 | Providing and fixing in position Pre-cast R.C.C. manhole cover and frame of requiredshape and approved quality.L D - 2.5Square shape 450 mm internal dimensions |
| 181 | ROAD WORKS |
| 182 | Construction of granular sub- base by Providing close graded Material conforming tospecifications, mixing in a mechanical mix plant at OMC, Carriage of mixed materialby tippers to work site, for all leads & lifts, spreading in uniform layers of specifiedthickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications anddirections of Engineer-in- Charge.With Material conforming to Grade - I ( size range75 mm to 0.075 mm) having CBR Value- 30 |
| 183 | Providing , laying spreading and compacting graded stone aggregate ( size range 53mm to 0.075 mm) to wet mix macadam (WMM) specification including premixingthe material with water at OMC in mechanical mix plant, carriage of mixed materialby tipper to site, for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub - base / base course on well prepared surface and compacting withvibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete asper specifications and directions of Engineer - in- Charge. |
| 184 | 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hotbitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively,including a tack coat with hot straight run bitumen, including consolidation with roadroller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately):WithRefinery Modified Bitumen CRMB 55 conforming to IRC:SP:53 - 1999 |
| 185 | Tack Coat - RS Bitumen Emulsion - On W.B.M / W.M.M @ 0.4 kg/ sqm - UsingPacked Bitumen Rates Providing and applying tack coat using bitumen emulsionconforming to IS : 8887, using emulsion pressure distributor including preparing thesurface & cleaning with mechanical broom. 1. With Rapid Setting BitumenEmulsion 1. On W.B.M / W.M.M @ 0.4 kg/ sqm |
| 186 | SIGNAGES |
| 187 | Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete asper the per the direction of Engineer in charge. <br> |
| 188 | NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design,Supplying andfixing Name Board as per the technical specifications given -1 Inch GI pipe frame(16Guage) for Frame (Sizeproportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets(Aluminum Composite Panel)for Box area, 18mm thick Multi wood Lettering for Name Board as approvedby<br> Engineer incharge.<br>For Measurement purpose, only area of ACP sheet to be measured |
| 189 | BUILDING PERMIT |
| 190 | Preparation of civil drawings, submission of drawings toLSGD/Municipality/Corporation/ concerned authority and obtaining approval for thesame, complete excluding the Departmental Fee for the Permission and Ownershipetc. Any statutory payment obligation shall be the sole responsibility of the client. |
| 191 | ELECTRICAL |
| 192 | POINT WIRING |
| 193 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 194 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 195 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 196 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 197 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 198 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. WALL FAN points. |
| 199 | CIRCUIT WIRING |
| 200 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 201 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 202 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 203 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including conduit and all accessories as required for complete installation and instructed by engineer in charge/consultant. 1Cx50sq.mm Copper Flexible Cable |
| 204 | SWITCH , SOCKET AND METAL BOXES |
| 205 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 206 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 207 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 208 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 209 | Supply and fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxes, its interconnections etc. as required complete. |
| 210 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 211 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 212 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 213 | Supplying and fixing following Modular base and cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 214 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 215 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 216 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 217 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 218 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 219 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 220 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 221 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 222 | DB,ENCLOSURE AND ITS ACCESSORIES |
| 223 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 224 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 225 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 WAY(4+12), DOUBLE DOOR |
| 226 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 227 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (butwithout MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 Way(4+24), Double door |
| 228 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way(4+24), Double door |
| 229 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way (4+18), Double door |
| 230 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 Way (4+12) Double door |
| 231 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 232 | Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 233 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel. making connections. etc. as required. 125 Amp, 36 KA |
| 234 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Double pole |
| 235 | Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 236 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current up to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A-40A, 4P, 30mA. |
| 237 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A-40A, 4P, 100mA |
| 238 | Supplying and fixing 40A / 63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 239 | Supplying and fixing 80A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 240 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Triple pole |
| 241 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Single pole |
| 242 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 243 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 244 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 245 | Supply, installation, testing and commissioning of SMC FRP rectangular junction Box (200 x 140 x 95mm) of approved make with MCB rail suitable for providing connection for fixing four pole isolator as per the direction of Engineer in charge. (Make: Sintex) |
| 246 | Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 247 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40amps DP Isolator complete with connections, testing and commissioning etc. as required. |
| 248 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 249 | Supply, installation, testing and commissioning of following rating Change Over Switch conforming to IEC 60947-3, IS/IEC 60947 -3, with CRCA sheet powder coated enclosure, complete with terminals and all accessories etc as required and as instructed by engineer in charge and making good any damages made during installation. 32/40A, 415V, FP COS |
| 250 | Supplying and fixing Cable End Boxes (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required.For 10 way, Double door SPN MCBDB |
| 251 | Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB |
| 252 | Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB |
| 253 | Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB |
| 254 | Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. |
| 255 | PANELS |
| 256 | Main Panel:-Supply, Installation, Testing and Commissioning of 415 V 50Hz LT Switch board OEM Design Verified Assembly Panel complying to IEC 61439 Part 1 & 2.The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type , Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition),cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears.All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance.INCOMER:1 Nos 630 A 36 kA 4P MCCB EDO MP based with 3O/C 1E/F Releases & S/T O/V relay with CT at neutral earthing conductor, 1 Nos 630 A 36 kA 4P MCCB EDO MP based, 2 Nos 630 A 4P Contactor, 2 Set RYB Indication Lamp with control fuses and switches, 2 No. Multi-function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring V,A,F,KW,KVA,PF,THD. CT and necessary accessories for APFC Relay in APFC Panel, 2 no. of Under Voltage/Over Voltage Relay. 1 no. Class B & Class C/ Class 1 & Class 2 Surge arrestor device with necessary HRC fuse for protection of same.OUTGOINGS:1 No 250 A, 36 kA, 4P MCCB, TM based, 1No 320A, 36kA, 4P MCCB, TM based, 4 No 160A, 36kA 4P MCCB, TM based, 2 Nos 125 A 36 kA 4P , MCCB, MP based, 1Nos 250 A TPN, IsolatorON-OFF-TRIP Lamps with 2A fuse -9 setsSurge Protection Devices for Main Panel: Type 1-2 sets, 400A 415V,50kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. All Breakers in the incoming side shall be with LSIG protection and all the breakers in the outgoing side shall be with LSI protection. ON/OFF/TRIP indicators shall be provided for all the breakers (incoming & outgoing). Necessary spreader terminals, extended ROH, phase barriers, shroudingetc shall be as per the rules. |
| 257 | SITC OF 110 KVAR APFC PANELFabrication, supply, erection, testing and commissioning of 16 SWG freestanding indoor cubicle type automatic power factor control panel of rating 110 kVAr with 7% block harmonic reactor with tuned capacitors using capacitor switching. By using Microprocessor based VAR controller which will be able to sense the reactive current requirement and switch on the required VAR providing intelligent switching based on actual value of KVAr and Bank size. 250A 36kA 4P MCCB with high rupturing capacity and in built overload and short circuit releases as per specifications as incomer, and MCB/MCCB's as outgoing as per the specifications, housing capacitors with heavy duty polypropylene as a dielectric with vaccum deposited conductors on the polypropylene as electrodes in steps of 10, i.e (25kVAr x 1+20kVAr x 2 + 15kVAr x 1 + 10kVAr x 2 + 5kVAr x 2) including 7% of the total KVA of transformer directly connected to the main bus for no load compensation with all accessories as required. Metering : Digital Ammeter with CT -3Nos , Digital Voltmeter with selector- 1No , Push Button, R Y B Indication with control fuse -1Set, Auto manual selector switch- 1No , Forced cooling using fans, APFC relay. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as per inspectorate standards. |
| 258 | LIFT PANEL :Fabrication, supply, erection, testing and commissioning of floor or wall mounting dust and vermin proof, cubicle type, front operated MV panel board as per IS 8623 - CPRI Certified made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. The panel shall be with Top/bottom entry to receive incoming & outgoing. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Incomer - 100A 16kA TM based MCCB , 125A , 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Multifunction meter having multiline LED display with following parameters -Phase wise instantaneous and Average values?Voltage, Current, Power Factor, Phase wise instantaneous and Average values?Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values? Active Energy, Reactive Energy lead & lag, Apparent Energy, PF for 3 phases and average, Instantaneous Frequency, Total Harmonics Distortion ? Phase wise Voltage and Phase wise Current - 1 Set RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoings: 63A 100mA 4P RCBO - 1 nos. , 25A 30mA DP RCBO - 1 nos., 6A SP MCB- 3Nos |
| 259 | SMDB-1 (8 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 and 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters and indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 160 A 36 kA TP MCCB, Outgoing: 5Nos 63A TP 25 kA MCCB, 3 NOS 25A 25kA TP MCCB |
| 260 | SMDB- UTILITY (4 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 and 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters and indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 160 A 36 kA TP MCCB, Outgoing: 1Nos 125A TP 25 kA MCCB, 2Nos 63A 25kA TP MCCB, 1 Nos 40A 25kA TP MCCB. |
| 261 | HVAC SMDB (12 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 and 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters and indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 320 A 36 kA TP MCCB, Outgoing: 4 Nos 80A 25kA TP MCCB, 8 Nos 63A TP 25 kA MCCB. |
| 262 | UPS SMDB (4 WAY) - Supply, installation, Testing and Commissioning of factory fabricated OEM 415 V 50 Hz 4 way complying to IEC 61439 part 1 and 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wire meter chamber with all meters and indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc, complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300 mm and maximum upto 1800mm from the finished floor level complete as per the directions of engineer in charge. Incomer -1 no. 160 A 36 kA TP MCCB, Outgoing: 3 Nos 50A 25 kA TP MCCB, 1 No 40A kA TP MCCB Details as shown in SLD. |
| 263 | CABLE SUPPLY AND LAYING |
| 264 | Supply and laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but including sand cushioning and protective covering (in ordinary soil). 3.5 core 400 sq mm |
| 265 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but including sand cushioning and protective covering (in ordinary soil) 3.5 core 400 sq mm |
| 266 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench120/102.5 mm or nearest size |
| 267 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm |
| 268 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm |
| 269 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 185 sq mm |
| 270 | Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3 core 185 sq mm |
| 271 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm |
| 272 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 120 sq mm |
| 273 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm |
| 274 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm |
| 275 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 70 sq mm |
| 276 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 277 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 278 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 279 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 280 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 281 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 282 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 283 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp |
| 284 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 285 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 286 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp |
| 287 | CABLE TERMINATION |
| 288 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 400 sq. mm (82mm) |
| 289 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 240 sq. mm (62mm) |
| 290 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 185 sq. mm (57mm) |
| 291 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 120 sq. mm (45mm) |
| 292 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 95 sq. mm (45mm) |
| 293 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 70 sq. mm (38mm) |
| 294 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 50 sq. mm (35mm) |
| 295 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X 35 sq. mm (32mm) |
| 296 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 25 sq. mm (28mm) |
| 297 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 16 sq. mm (28mm) |
| 298 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 10 sq. mm (25mm) |
| 299 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (22mm) |
| 300 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3C X 4 sq. mm (22mm) |
| 301 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.2 X 6 sq. mm (19mm) |
| 302 | Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.2 X 4 sq. mm (19mm) |
| 303 | CABLE TRAY |
| 304 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness |
| 305 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness |
| 306 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness |
| 307 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 600 mm width X 50 mm depth X 2.0 mm thickness |
| 308 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 309 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness |
| 310 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 311 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness |
| 312 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 313 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 314 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 315 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 316 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 317 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness |
| 318 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 319 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends withperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 320 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 321 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 322 | Supplying and installing following size of perforated painted with powder coatingM.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness |
| 323 | EARTHING PROTECTION |
| 324 | Supply, installation and tesing of 1200mmx1200mmx12mm CI plate electrode earth station conforming to IS:3043-1987 / NEC / IEE complete with brick masonry chamber, CI cover, CI frame, GI watering pipe of 50 mm dia with funnel having 20G GI wire mesh etc. The CI cover frame/ chamber shall be of 1000mm x 500mm x 600mm size. CI manhole cover with frame shall be painted with bitumastic paint, identification of earthpit with yellow paint below the chamber cover, mixtures of charcoal and common salt around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. ( value of earth resistance should be less than 1 ohm ) |
| 325 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt and spring washer spaced at 50mm) |
| 326 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 327 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 328 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) |
| 329 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 330 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 331 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 332 | LIGHT AND FAN FIXTURES |
| 333 | SITC of 2x 2 LED Recess mounted 36W light fixture, system efficacy -110 lm/W and system lumen output not less than 3600 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distributionwith CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor-0.95, THD-10%, rated life of 50,000 hours at L70 with a CRI-80, UGR -19, SDCM-5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor - 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate and BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make. |
| 334 | SITC of LED recessed downlight fixture Maximum 18W (+/-2) light fixture. System efficacy -110 lm/W and system lumen output not less than 1980 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor- 0.95, THD-10%, rated life of 50,000 hours at L70 with a CRI - 80, UGR -19, SDCM-5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLSPVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate and BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same |
| 335 | SITC of LED recessed downlight fixture Maximum 10W light fixture. System efficacy -110 lm/W and system lumen output not less than 1100 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor-0.95,THD-10%, rated life of 50,000 hours at L70 with a CRI - 80, UGR -19,SDCM-5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate and BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same. |
| 336 | SITC of 4 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2200 lumens, luminaire efficacy -110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminium section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K/6500 K, CRI - 80, power factor -0.95, SDCM - 5, THD -10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs The luminaire shall have CRI-80, THD - 20%. The luminaire shall have an internal surge protection of 4 kV with 25,000 burning hours as per L70B50 criteria. |
| 337 | SITC of 2 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1100 lumens, luminaire efficacy - 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminum section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K/6500 K, CRI - 80, power factor -0.95, SDCM - 5, THD -10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content -5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation. |
| 338 | SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy-=100 lm/W and system lumen output not less than 1000 lm. , drive mum 2.50 KV internal surge protection with electronic drive system, power factor -0.95, THD-10%, rated life of 50,000 hours at L70 with a CRI - 80, SDCM-5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate and BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make |
| 339 | Supply, installation, testing and commissioning of Integral, SMD LED, IP 65, 80 W LED Surface/Suspend Mounted Round Mid-Bay / High-Bay fixture with System efficacy of more than 135 lm/W (10800 lumens). Luminaire shall be made up of Die Cast Aluminium Housing. Luminaire shall have PC lens with polycarbonate reflecxor for Uniform illumination and wider light distribution. The innovative design with Aeroflo Technology ensures flow of free air through the Housing and keep the heat away from Electrical Components. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo- biological safety and certificate for the same from manufacturer shall be provided.Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70B50 life of 100000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be CRCA constructed, Isolated type, multistage Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage ? 240V) with 4 KV internal surge protection, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13): 2012; IS 16108 : 2012. |
| 340 | Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 341 | Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) including painting etc. as required. |
| 342 | Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 343 | SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, 9" or 10" star rated as per BEE, with its all accessories including mounting as required for complete installation. |
| 344 | SITC of Exhaust Fan Celling mounted type with flexible hose of required length and vent cowl as bird net, Make similar to Luker LXC 200mm 21W 1050RPM Tubular Ventilating Ceiling Mounted Fan or equivalent with its all accessories including mounting accessories. |
| 345 | SITC of 450mm sweep Wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation. |
| 346 | CEILING FAN CLAMP |
| 347 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 348 | LIGHTNING PROTECTION |
| 349 | Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 2500mm length (8.20 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous arrangement with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding.Stainless steel Clamp for Bonding. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances. The mineral compound is required to have minimum 15 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. FRP Earth electrode inspection chamber with weight bearing capacity of 60KN. The dimension shall be 290mmx 290mmx 209mm. Govt approved Indian labs test certificate required |
| 350 | Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm. Govt approved Indian labs test certificate required |
| 351 | Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required |
| 352 | Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor and 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding . Conforms to the requirements according to (IS/IEC 62305).The enclosure should be outdoor glass-fibre reinforced polycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium and 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch eachg other to avoid bimetallic corrosion. Single bolt joints are not permitted. Govt approved Indian labs test certificate required |
| 353 | Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece with Connector: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required |
| 354 | Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters |
| 355 | Providing and fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters |
| 356 | Providing and fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.Conductor with Parapet Holder made of whether resistant plastic holder @ every 0.5 meters |
| 357 | Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3. For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. 6 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel Tripod Stand |
| 358 | Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3. For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required.4 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories |
| 359 | Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3. For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. 4 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories |
| 360 | SAFETY MEASURES |
| 361 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 362 | Supply and fixing Laminated drawings of electrical layout, schematic drawing etc. with teakwood frame work on wall as approved by the directorate of electricity |
| 363 | Supply and fixing of Shock treatment chart duly mounted on a wooden frame with glass on front as required in 2 languages (Hindi and English). |
| 364 | Providing and fixing in position 2M X 1M X 2MM , Elastomeric Insulating Mats as per IS 15652:2006, 2.0mm thick, suitable upto 3.3kv(class A), fire retardant, no effects of acids, alkalis and transformer oils, moisture proof, high tensile strength and tenure finish/ cloth impression(Anti slip marking on top) |
| 365 | PUMP SET |
| 366 | Supply, installation, testing, and commissioning of a Solar-assisted Heat Pump, an insulated pressurized SS storage tank, a hot water expansion vessel, insulated piping between the system, valves, and accessories required to complete the system in position with the following specifications: The system should have a capacity of 1500 Liters, consisting of Solar Hot Water Panels with an aggregate capacity of 750L (50% of the total requirement). The insulated Hot Water Storage Tank should be suitable for 6 bar pressure, made of SS 316 - 1 number, 1500 Liters, and can be either horizontal or vertical as per site requirements, Hotwater output range 55°c to 60°c.System operating temp. range - 15-43°c. The Heat Pump should have a COP of at least 4, with a minimum 12 KW heating capacity and a minimum 300 LPH flow rate. Storage tank shall include a back up electrical heater capacity of minimum 6KW. A circulation system with a pump (1 working + 1 standby) between the heat pump and storage tank, all inclusive of a control panel is required. Plumbing work should use CPVC pipes with suitable fittings, and brass fittings should include NRV, Y Strainer, Air Vent, MTA, FTA, and Flow Switches, with pipeline insulation. The price shall include all electrical work from the pump panel to the Heat Pump, including cabling, PVC conduits, contactors, suitable fittings, and all accessories in complete as required |
| 367 | SITC of 5 HP Pure Copper Winding Domestic/ Industrial Three Phase Self Priming Monoblock Pump Discharge Range minimum 7.6 lps |
| 368 | Supply, installation, testing and commissioning of single phase pressure boosting pump, 0.6 KW/0.8 HP, 25 mm SUC, and 25 mm DEL., 6 outlets, 3 stages, CI impeller, SS shaft, Mechanical seal, suitable for 35 mtr to 6 mtr head and 20 lpm and 100 lpm discharge respectively. |
| 369 | S and F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor |
| 370 | S and F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor |
| 371 | Supply, Installation, testing and commission, of Water Transfer submersible Pump, for water from Underground tank to overhead tank, with including solenoid valves, level switches, control wires etc. The price shall inclusive of all connected electrical work. Capacity 350lpm at 20Mtrs. head, Electric motor driven, (HP as per selection of pump) single phase, 230V, AC Supply |
| 372 | Supply, Installation, testing and commission, of 1HP sewage transfer pump submersible pump with including solenoid valves, level switches, control wires etc. The price shall inclusive of all connected electrical work. Electric motor driven, (HP as per selection of pump) three phase, 415V, AC Supply |
| 373 | 50KVA Modular(N+1) UPS:-Supply, installation, and commissioning of MODUALAR UPS, suitable Frame size for N+1 with maximum 25kW modules in each frame of 3 phase modules three phase in and out and indoor (IP20) with surge protection system having 30 min backup battery @47.5 kW load battery sizing calculation to be provided from the OEM, with isolator for each bank battery of reputed approved make ,Input pf 0.99, Input THDi 3%, double conversion technology with input 400V, 50Hz three phase, output 400V, 50Hz three phase, SNMP card for network monitoring, BMS compatibility etc. It shall be 100% generator compatible, with Efficiency 96 % and output power factor Unity (kva = kW), Eco mode Efficiency 99% and including all accessories etc as required. The acoustic noise at 1m of the system should be-80dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE,IEC62040-4 or ISO14025 or equivalentrelevant IS standard. The system shall be true online double -conversion DSP based UPS system and also UPS shall be with automatic and manual bypass switch. The system shall have 3 level IGBT rectifier and inverter. including rack and interconnecting cables. Battery backup time required is 30 Min. using external SMF batteries. The product offered sufficient battery Ah capacity for required backup. |
| 374 | ELEVATOR |
| 375 | Design, Manu uitable for operation on 415 V, 50 Hz, three phase AC supply with Variable Voltage and Variable Frequency (VVVF) drive for the main drive motor as well as door opening motor which comply with power quality requirements as per the latest version of IEEE 519 with electromagnetic brake system, correction drive to next level,,simple operation/simplex full selective collective operation with/ without attendant, operating control panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency lamp, intercom suitable for hook-up to EPABX (wiring for the intercom shall be terminated near to the main control panel), infrared ray curtains to the full height of the door, protections for reverse power, loss of phase & overload etc., limit switches, over speed governor, fireman?s switch at the ground floor etc.Car body shall be made of 304 grade SS with hairline finish, flooring with 2.50 mm fluted SS, with centre/ side opening doors, hand rails on 3 sides, mirror on the rear side, digital car position indicators in the car and at all landings with UP/DOWN directions, control panel with braille markings, occupancy sensor operated LED lighting in the car to maintain at least 150 lux and ventilating fan, ARD with battery etc. The landing doors shall be made of the same material as of the car body with fire rating as per current Standards. The installation shall include necessary scaffolding, all required minor civil works, construction of buffer blocks with springs, supply and fixing all supporting steel structures, architraves with 16 mm granite/ large format ceramic tile of approved size and pattern, all required electrical works including wiring inside the shaft and providing necessary light fittings, receptacles etc., supply and fixing necessary control panels and controls as per Standards, all power and control wirings encased in metal/ PVC conduits/ troughs etc. The electrical work shall be done in conformity with NEC 2023 and other relevant Standards. The manufacture and installation of the lifts shall be in compliance with the latest versions of IS 14665, IS 17900, IS 17106 and other relevant Standards. The efficiency of the lift shall be class A according to IS 17515. All certificates/ documents to prove the compliance shall be submitted on completion of workMachine Room Less (MRL) type 20 passenger (1360 kg) bed lift having a speed of 1 m/s in the available lift shaft of size 3100 mm (D) x 2400 mm (W) with a total travel distance of 10 m with 3 stops and 3 openings on the same side, minimum door opening size 1200 mm (W) x 2000 mm (W) with stretcher impact protection on 3 sides. |
| 376 | DOCUMENTATION AND APPROVAL |
| 377 | DOCUMENTATION AND APPROVAL "Charges for Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energization certificates from Electrical Inspectorate and KSEB, obtaining power allocation and power connection etc. including feasibility study. for commissioning of the whole installation. All statutory payments will be reimbursed on production of the original receipts. (for modification works) |
| 378 | HVAC WORKS |
| 379 | HVAC - VRF SYSTEM |
| 380 | Supply, Installation, Testing and Commissioning of air-cooled VRV (Variable Refrigerant Volume) / VRF (Variable Refrigerant Flow) outdoor units (ODUs) equipped with highly efficient, full DC inverter-driven scroll compressors only, air- cooled heat exchangers having internally grooved copper tubes, and low-noise condenser fans.The units shall have auto-addressing, an auto-check function for connection errors, and operate with R-410A or equivalent refrigerant gas. Each unit shall be fitted with a noise filter, high-pressure switch, fan motor overload protector, over-current relay, inverter overload protector, and other necessary protective devices.A power failure of one or more IDUs shall not affect operation of other units/circuits. The units shall deliver the rated capacity in accordance with IS 18728:2024 and CPWD specifications. The efficiency of the ODUs shall meet the latest ASHRAE / ECSBC 2024 standards. Suitable vibration isolators shall be provided with the ODUs. The system shall operate at outdoor conditions up to a maximum ambient dry-bulb temperature of 50°C. Each unit shall be equipped with an oil recovery system to ensure stable operation with long refrigeration piping lengths and an oil-balancing circuit to prevent inadequate lubrication. Compatibility with centralized control systems such as BACnet, LonWorks, and Modbus is required.The ODUs shall be suitable for a 3-phase, 415 V, 50 Hz power supply, with suitable interconnecting control cabling between IDUs, ODUs, and the central controller. All necessary power cabling up to the ODU electrical panel, pressure testing, additional refrigerant charging for commissioning, and all associated accessories required for commissioning shall be included in the scope of work. The VRF outdoor unit circuit schedule shall be as per the tender drawings/specifications.. |
| 381 | Supply, Installation, Testing, and Commissioning of VRV/VRF 1.6TR high-wall type indoor unit complete with a corded/cordless remote (subject to consultant's approval). The machine shall be suitable for operation on 230 V, 50 Hz, single-phase AC supply, including all power cabling to the nearest power socket. The unit shall include a washable synthetic media pre-filter, DC fan section with a low-noise fan/dynamically balanced blower, multi-speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, and necessary accessories,etc.. |
| 382 | Supply, Installation, Testing, and Commissioning of VRF/VRV 1.6TR ceiling- mounted low-static ductable type indoor unit along with a corded remote. The unit shall be equipped with a washable synthetic media pre-filter, a fan section with a low- noise, dynamically balanced fan, a multi-speed motor, a coil section with a Dx copper coil, an electronic expansion valve, a corded remote control, an outer cabinet, vibration isolators, a drain pan, and other necessary supports, suitable for operation on a single-phase AC supply of 230 V ± 10%, 50 Hz.. |
| 383 | Supply, Installation, Testing, and Commissioning of VRF/VRV 2.0TR ceiling- mounted low-static ductable type indoor unit along with a corded remote. The unit shall be equipped with a washable synthetic media pre-filter, a fan section with a low- noise, dynamically balanced fan, a multi-speed motor, a coil section with a Dx copper coil, an electronic expansion valve, a corded remote control, an outer cabinet, vibration isolators, a drain pan, and other necessary supports, suitable for operation on a single-phase AC supply of 230 V ± 10%, 50 Hz.. |
| 384 | Supply, Installation, Testing, and Commissioning of VRF/VRV 4.0TR ceiling- mounted, mid/high static ductable type indoor unit along with a corded remote. The unit shall be equipped with a washable synthetic media pre-filter, a fan section with a low-noise, dynamically balanced fan, a multi-speed motor, a coil section with a Dx copper coil, an electronic expansion valve, an outer cabinet, vibration isolators, a drain pan, and other necessary supports, suitable for operation on a single-phase AC supply of 230 V ± 10%, 50 Hz.. |
| 385 | Supply, Installation, Testing, and Commissioning of VRF/VRV 5.5TR ceiling- mounted, mid/high static ductable type indoor unit along with a corded remote. The unit shall be equipped with a washable synthetic media pre-filter, a fan section with a low-noise, dynamically balanced fan, a multi-speed motor, a coil section with a Dx copper coil, an electronic expansion valve, an outer cabinet, vibration isolators, a drain pan, and other necessary supports, suitable for operation on a single-phase AC supply of 230 V ± 10%, 50 Hz.. |
| 386 | Supply and installation of indoor Refnet / Y-joint separation tubes for refrigeration pipe joints and headers, in appropriate orientation to enable proper distribution of refrigerant. The distribution joints shall be factory insulated with pre-formed sections of expanded polystyrene or equivalent.. |
| 387 | Supply and installation of outdoor Refnet / Y-joint separation tubes for refrigeration pipe joints and headers, in appropriate orientation to enable proper distribution of refrigerant. The distribution joints shall be factory insulated with pre-formed sections of expanded polystyrene or equivalent.. |
| 388 | Supply, Installation, Testing, and Commissioning of centralized type remote controller, color touchscreen type with UPS battery backup, all-inclusive of necessary installation supports and wiring. The controller shall function as an advanced air conditioning management system, providing complete control of VRV/VRF air conditioning equipment (including connected air handling units (AHUs)). It shall offer user-friendly operation through its touchscreen, icon display, and color LCD display. The controller shall be compatible with BACnet, LonWorks, or Modbus interface. The controller shall control up to 64 groups of indoor units with the following functions:1. Start/stop of air conditioners as a zone, group, or individual unit2. Temperature setting for each indoor unit or zone3. Switching between temperature control modes, fan speed adjustment, and airflow direction control, including enable/disable of individual remote controller operation4. Monitoring of operation status, including operation mode, temperature settings of individual indoor units, maintenance information, and troubleshooting details5. Scheduling indoor unit operating time6. Displaying air conditioner operation history.. |
| 389 | Supply, Installation, Testing, and Commissioning of the Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/4 inch (6.35 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 390 | Supply, Installation, Testing, and Commissioning of theSoft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:3/8 inch (9.52 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 391 | Supply, Installation, Testing, and Commissioning of the Soft drawn Copper Pipe 19/20 Gauge with 19mm thick Insulation:1/2 inch (12.7 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 392 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:5/8 inch (15.88 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 393 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:3/4 inch (19.05 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 394 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:7/8 inch (22.2 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 395 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1.0 inch (25.4 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 396 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/8 inch (28.6 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 397 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/4 inch (31.8 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 398 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-3/8 inch (34.9 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 399 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 18/19 Gauge with 19mm thick Insulation:1-1/2 inch (38.1 mm) gas/liquid insulated copper piping. The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 400 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 17/18 Gauge with 25mm thick Insulation:1-5/8 inch (41.3 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 401 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 16/17 Guage with 25mm thick Insulation:1-3/4 inch (44.45 mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 402 | Supply, Installation, Testing, and Commissioning of the Hard drawn Copper Pipe 16/17 Guage with 25mm thick Insulation:1-7/8 inch (47.62mm) gas/liquid insulated copper piping.The insulation for copper piping shall be round, closed-cell, antimicrobial nitrile rubber sleeve insulation. The minimum R-values for pipes shall be 0.4 for pipe sizes less than 40 mm and 0.7 for pipe sizes 40 mm and above. Insulation shall be finished with 7 mils of factory-laminated fiberglass cloth. The thermal conductivity of the insulation material shall not exceed 0.035 W/(m·K) at a mean temperature of 0°C as per EN ISO 8497. The installation includes suction filters for the gas line, a filter drier, and a sight glass for the liquid line per the system design between each indoor and outdoor unit. The scope of work shall include chasing, drilling, core cutting, and concealing in walls, as per site conditions, along with the required pipe fittings and accessories such as bends, tees, reducers, Y-joints, supports, refnets, and wall clamps, for the proper commissioning of the VRF/VRV circuit. The thickness of the fittings shall match the pipe thickness.PVC sleeves shall be securely fixed over the copper pipes to provide a protective barrier at all wall openings and along support channels. The work shall be completed as per the consultants approval. The contractor shall ensure that the pipe size and thickness of all refrigerant pipes installed are in accordance with the Original Equipment Manufacturer (OEM) recommended technical specifications.. |
| 403 | Supply, installation, and testing of shielded copper flexible communication cabling between VRF indoor and outdoor units. The communication cable shall be routed through PVC conduits. The cable size shall be 2-core x 1.5 SQMM (or) as per VRF OEMs technical specifications.. |
| 404 | Supply, installation, testing, and commissioning of 25mm dia rigid UPVC condensate drain piping duly insulated with 9 mm thick closed-cell nitrile finished with 7 mils factory-laminated glass cloth, along with necessary U-trap, clamps, fittings such as bends, tees, and other necessary fittings, adequately supported as per site requirements, conforming to tender specifications.. |
| 405 | Supply, installation, testing, and commissioning of 32mm dia rigid UPVC condensate drain piping duly insulated with 9 mm thick closed-cell nitrile finished with 7 mils factory-laminated glass cloth, along with necessary U-trap, clamps, fittings such as bends, tees, and other necessary fittings, adequately supported as per site requirements, conforming to tender specifications.. |
| 406 | Supply, installation, testing, and commissioning of 40mm dia rigid UPVC condensate drain piping duly insulated with 9 mm thick closed-cell nitrile finished with 7 mils factory-laminated glass cloth, along with necessary U-trap, clamps, fittings such as bends, tees, and other necessary fittings, adequately supported as per site requirements, conforming to tender specifications.. |
| 407 | Supply, installation, testing, and commissioning of 3.0TR - 1200 CFM, 40mm E.S.P, VRF-compatible DX type recirculating factory-built AHUs with 2-stage filtration, 6- row DX cooling coil, double-skin AHU made of 50 mm thick panels consisting of 0.8 mm thick pre-coated GSS on outside, 0.8 mm thick Aluminum sheet inside with factory-injected PUF with a minimum density of 40 kg/m³. The AHU shall be ceiling- or floor-mounted type, single- or double-deck (as per site conditions) along with thermal-break aluminum extruded profile at corners and joints, complete with plug fan compatible with VFD as specified in the starter panel, suitable IE3 class (per IS 12615) TEFC drive motor with IP55 protection suited for 415 ± 10% volts, 50 Hz, 3- phase AC supply, minimum two-bend GSS/PVC eliminators, cooling coil section with aluminum-finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic-type air pre- and fine filters (MERV 8 and MERV 14), mixing box, aluminum VCDs on fresh air, return air, and supply air openings, drain connection, 18 G stainless steel 304 with 19 mm NBR-insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, VRF/DX AHU kit, corded remote controller, limit switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254 nm wavelength radiation, 7.5 W/sqft of coil surface area for equal distribution. Heaters (capacity to be proposed by OEM) to be slip-in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, air stat/airflow switch, and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power and control cabling, earthing between AHU/strip heaters and control panel, all supporting GI hangers, MS angles, channels, nuts, bolts, washers, and other necessary items for unit installation shall be included in the scope of supply. Fans shall be Eurovent/AMCA- certified. AHUs shall be Eurovent/AHRI-certified.. |
| 408 | Supply, installation, testing, and commissioning of 5.5TR - 2200 CFM, 50mm E.S.P, VRF-compatible DX type recirculating factory-built AHUs with 2-stage filtration, 6- row DX cooling coil, double-skin AHU made of 50 mm thick panels consisting of 0.8 mm thick pre-coated GSS on outside, 0.8 mm thick Aluminum sheet inside with factory-injected PUF with a minimum density of 40 kg/m³. The AHU shall be ceiling- or floor-mounted type, single- or double-deck (as per site conditions) along with thermal-break aluminum extruded profile at corners and joints, complete with plug fan compatible with VFD as specified in the starter panel, suitable IE3 class (per IS 12615) TEFC drive motor with IP55 protection suited for 415 ± 10% volts, 50 Hz, 3- phase AC supply, minimum two-bend GSS/PVC eliminators, cooling coil section with aluminum-finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic-type air pre- and fine filters (MERV 8 and MERV 14), mixing box, aluminum VCDs on fresh air, return air, and supply air openings, drain connection, 18 G stainless steel 304 with 19 mm NBR-insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, VRF/DX AHU kit, corded remote controller, limit switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254 nm wavelength radiation, 7.5 W/sqft of coil surface area for equal distribution. Heaters (capacity to be proposed by OEM) to be slip-in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, air stat/airflow switch, and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power and control cabling, earthing between AHU/strip heaters and control panel, all supporting GI hangers, MS angles, channels, nuts, bolts, washers, and other necessary items for unit installation shall be included in the scope of supply. Fans shall be Eurovent/AMCA- certified. AHUs shall be Eurovent/AHRI-certified.. |
| 409 | Supply, installation, testing, and commissioning of 8.5TR - 3400 CFM, 50mm E.S.P, VRF-compatible DX type recirculating factory-built AHUs with 2-stage filtration, 6- row DX cooling coil, double-skin AHU made of 50 mm thick panels consisting of 0.8 mm thick pre-coated GSS on outside, 0.8 mm thick Aluminum sheet inside with factory-injected PUF with a minimum density of 40 kg/m³. The AHU shall be ceiling- or floor-mounted type, single- or double-deck (as per site conditions) along with thermal-break aluminum extruded profile at corners and joints, complete with plug fan compatible with VFD as specified in the starter panel, suitable IE3 class (per IS 12615) TEFC drive motor with IP55 protection suited for 415 ± 10% volts, 50 Hz, 3- phase AC supply, minimum two-bend GSS/PVC eliminators, cooling coil section with aluminum-finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic-type air pre- and fine filters (MERV 8 and MERV 14), mixing box, aluminum VCDs on fresh air, return air, and supply air openings, drain connection, 18 G stainless steel 304 with 19 mm NBR-insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, VRF/DX AHU kit, corded remote controller, limit switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254 nm wavelength radiation, 7.5 W/sqft of coil surface area for equal distribution. Heaters (capacity to be proposed by OEM) to be slip-in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, air stat/airflow switch, and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power and control cabling, earthing between AHU/strip heaters and control panel, all supporting GI hangers, MS angles, channels, nuts, bolts, washers, and other necessary items for unit installation shall be included in the scope of supply. Fans shall be Eurovent/AMCA- certified. AHUs shall be Eurovent/AHRI-certified.. |
| 410 | Supply and installation of a suitable, CPRI-approved (IEC 61439) AHU VFD starter panel, factory-fabricated, wall-mounted type, including all necessary control and power cable wiring between the AHU and the panel.The motor control shall be facilitated by a variable frequency drive (VFD) complying with the latest IEEE 519 standards. The panel shall incorporate controls such as contactors, overload relays (OLR), single-phase preventer (SPP), control switches, and MCBs for AC units.The panel shall have a 24V AC power supply for fire interlock. The panel shall have an auto/manual selection switch, on/off push buttons, and on, off, and trip indication lamps, etc.The panel shall have control element features, including a humidistat, thermostat, air stat/airflow switch, and safety thermostat, along with control wiring.The panel shall feature ON/OFF switches with indicators and a bypass DOL/star-delta starter (selected based on motor size) for the VFD, along with a manual changeover switch for transitioning between VFD and bypass operationsThe fan/blower motor shall be interlocked with heaters (where provided) such that the power supply to the heaters will be switched on only after the blower has been started and run to full designed speed.The panel shall have contactors and breakers for the heater banks, with the required power and control wiring to maintain temperature/RH % as per indoor design conditions.. |
| 411 | Supply, installation, testing, and commissioning of inline exhaust fan 600CFM @ minimum 15mm static pressure. The fan shall be AMCA-certified for both air performance and sound performance. The fan casing shall be constructed from galvanized sheet steel. The installation cost shall be inclusive of an electronic speed regulator, power and control wiring between the power supply and the fan and speed regulator, suitable enclosure, plug for socket connection, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 412 | Supply, installation, testing, and commissioning of cabinet fan (EXHAUST AIR) 600CFM @ minimum 40mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a HEPA filter having a minimum efficiency of 99.97% at 0.3 m. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 413 | Supply, installation, testing, and commissioning of cabinet fan (EXHAUST AIR) 1000CFM @ minimum 40mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a HEPA filter having a minimum efficiency of 99.97% at 0.3 m. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 414 | Supply, installation, testing, and commissioning of cabinet fan (EXHAUST AIR) 1500CFM @ minimum 60mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a HEPA filter having a minimum efficiency of 99.97% at 0.3 ?m. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 415 | Supply, installation, testing, and commissioning of cabinet fan (EXHAUST AIR) 2000CFM @ minimum 60mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a HEPA filter having a minimum efficiency of 99.97% at 0.3 ?m. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 416 | Supply, installation, testing, and commissioning of cabinet fan (EXHAUST AIR) 2500CFM @ minimum 60mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a HEPA filter having a minimum efficiency of 99.97% at 0.3 ?m. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 417 | Supply, installation, testing, and commissioning of cabinet fan (EXHAUST AIR) 3500CFM @ minimum 60mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a HEPA filter having a minimum efficiency of 99.97% at 0.3 m. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 418 | Supply, installation, testing, and commissioning of cabinet fan (FRESH AIR) 800CFM @ minimum 40mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible three-phase motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a MERV 8 pre-filter. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 419 | Supply, installation, testing, and commissioning of cabinet fan (FRESH AIR) 1500CFM @ minimum 40mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible three-phase motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a MERV 8 pre-filter. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 420 | Supply, installation, testing, and commissioning of cabinet fan (FRESH AIR) 2000CFM @ minimum 60mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible three-phase motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a MERV 8 pre-filter. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 421 | Supply, installation, testing, and commissioning of cabinet fan (FRESH AIR) 3000CFM @ minimum 60mm static pressure. The casing shall be double-skin, acoustically lined internally, and constructed from galvanized steel. Fans with three- phase motors shall be equipped with VFD-compatible three-phase motors. The fan shall be AMCA-certified for both air performance and sound performance. The fan shall be equipped with a MERV 8 pre-filter. The installation cost shall be inclusive of an electronic speed regulator for single-phase fans. For three-phase fans, the installation cost shall include a VFD starter panel, along with necessary power and control wiring for connecting the power supply, fan, and VFD panel, as well as suitable enclosures, mounting brackets, and all other necessary accessories, as per site conditions.. |
| 422 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet |
| 423 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet |
| 424 | Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 Thickness 1.00 mm sheet |
| 425 | Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick |
| 426 | Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick |
| 427 | Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 1.00 mm thick |
| 428 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class \\"\\"O\\"\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrille rubber insulation - 25 mm |
| 429 | Supply, storage, installation, testing, and commissioning of 10 mm thick acoustic insulation for ducts using nitrile rubber open-cell foam, fibre-free material with a minimum density of 140 kg/m³. The insulation shall have antimicrobial protection in accordance with ASTM G-21 and ASTM E-2180 and shall conform to Class 1 rating for flame spread as per BS 476 Part 7. The work shall be carried out in line with the specification and designed to meet the required noise criteria. The insulation shall be applied up to a distance of 4 metres from the fan outlet (or) as instructed by the Engineer-in-Charge. The insulation system shall be complete in all respects for commissioning.. |
| 430 | Supply and application of two coats of a vapor barrier coating (Foster painting) on exposed ducts / copper refrigerant pipelines, as per the Engineer-in-Charge’s directions. The work includes surface preparation, application of the vapor barrier coating, and related works to ensure complete coverage and protection.. |
| 431 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.Gl volume control duct damper |
| 432 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper |
| 433 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator |
| 434 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. |
| 435 | Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required. |
| 436 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core. |
| 437 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core. |
| 438 | Supply and installation of fresh air/exhaust air louver constructed from powder- coated aluminium with bird screen as per the specifications and drawings.. |
| 439 | Supply, installation, fixing, and hanging of factory-fabricated fire-retardant flexible canvas connection of minimum 150 mm width at the outlet of each ducted indoor unit with a zipper to facilitate temperature measurement. The fabric shall be made of polyester cloth with black PVC coating on both sides and a galvanized steel seam.. |
| 440 | FIRE FIGHTING |
| 441 | PUMPS |
| 442 | a)Supplying,installation,testing and commissioning of Electric driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520.C) Suitable HP Squirrel Cage Induction Motor, TEFC, Synchronous speed 1500rpm suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325.d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads 2280 lpm at 70 m head |
| 443 | a)Supplying,installation,testing and commissioning of Diesel Engine driven Main Fire Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Diesel Driven Pump)b) Horizontal type, Multi stage ,centrifugal, split Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520.C) Suitable HP ,1500rpm,water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 V Electric starting equipment,diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50 mm thick glass wool with 1 mm thick Al sheet cladding residential silencer, instruments and protection as per standard specifications, stop solenoid for Auto stop in the event of fault with audio indications, painted with post office red colour etc as required.d) M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads2280 lpm at 70 m head |
| 444 | a)Supplying, installation, testing and commissioning of Electric driven Pressurisation Pump suitable for Automatic operation and consisting of following, complete in all respect , as required :(Jockey Pump)b) Horizontal type, Multi stage ,centrifugal, split casing Pump of Cast Iron body and bronze impeller with stainless steel shaft ,mechanical seal conforming to IS 1520.C) Suitable HP Squirrel Cage Induction Motor, TEFC type suitable for operation on 415 V 3 phase 50 HZ AC supply with IP55 Protection for enclosure ,horizontal foot mounted type with class F insulation, conforming to IS 325.d)M.S Fabricated common base plate coupling, coupling guard ,foundation bolts etc as required.e) Suitable cement concrete foundation duly plastered with Anti vibration pads180 lpm at 70m Head |
| 445 | PUMP PANEL |
| 446 | Fabrication, supply, installation, testing and commissioning of Electrical Control Panel of cubicle construction Floor mounted type fabricated out of 2 mm thick CRCA sheet compartmentalised with hinged lockable doors, dust vermin proof, powder coated of approved shade after 7 tank treatment process cable alleying interconnection with suitable size copper conductor cable or solid copper strip having switchgearsand accessories, mopuntigs and internal wiring, earth terminals, numbering etc., complete in all respects suitable for main fire pump , pressurisation pump and diesel pump set complete as per CPWD specification with following incoming and outgoings suitable for operation of 415 V, 3 phase, 50 Hz, AC supply with enclosure protection class IP 42 as required: INCOMING : 250A, 50kA 4P MCCB ,Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter 0-250A with selector switch and CTs etc. LED Type RYB phase indicating Lamps ,ON/OFF, Trip indicating lamps set of Cu Bus Bar 300A .OUT GOING:(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)MAIN FIRE PUMP:125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.JOCKEY PUMP :63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL:Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC AmmeterAll standard relays and accessories for automatic operation of diesel engine System ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 447 | PIPES,VALVES AND ACCESSORIES |
| 448 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:25 mm dia |
| 449 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:32 mm dia |
| 450 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:40 mm dia |
| 451 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:50 mm dia |
| 452 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:65mm dia |
| 453 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:80mm dia |
| 454 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:100mm dia |
| 455 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:150mm dia |
| 456 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 3589,IS 1239 i/c welding ,fittings, like elbows, tees, flanges, tapers, nuts ,bolts ,gaskets etc., and fixing the pipe on the wall , ceiling with suitable clamp or support frame and painting with two or more coats of synthetic enamel paints of required shades complete as required:200mm dia(Wall thickness 6.3mm) |
| 457 | Providing, laying, testing and commissioning of C class heavy duty M S Pipe conforming to IS 1239/3589 i/c fittings, like elbows, tees, flanges, tapers, nuts ,bolts,gaskets etc., in ground including welding ,excavation and providing cement concrete blocks as supports, Anti corrosive treatment with coal tar ,Asphalt type as per IS 10221, refiiling the trench etc., of following sizes150 mm dia |
| 458 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:80 mm dia |
| 459 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:100 mm dia |
| 460 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:150 mm dia |
| 461 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze or gun metal seat duly ISI marked complete with nuts, bolts ,washers,gaskets conforming to IS 13095 of following sizes as required:200 mm dia |
| 462 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.80mm dia |
| 463 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.100 mm dia |
| 464 | Providing,installation,testing and commissioning of non-return valve of following sizes conforming to IS :5312 complete with rubber gasket, GI bolts , nuts, washers etc as required.150mm Dia |
| 465 | Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates,pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipeof required size, flanges, orifice plate, gasket etc of follwing sizes as required:150 mm dia |
| 466 | Supplying and fixing single headed external yard hydrant valve with one no: 63 mm dia instantaneous FM Gun metal or stainless steel coupling and cast iron wheel, ISI marked ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel |
| 467 | Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal or stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290(Type A) with blank Gun metal or Stainless steel cap and chain as required:Single headed stainless steel |
| 468 | Providing, installation ,testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel , Grade 304,sheet with3 mm dia holes with stainless steel flange.200 mm dia |
| 469 | supplying and fixing air vessel made of 250 mm dia 8 mm thick MS sheet , 1200 mm in height with Air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia Gun metal wheel valve with required accessories , pressure guage and painting with synthetic enamel paint of approved shade as required. |
| 470 | Providing and fixing of pressure switch in MS pipeline including connection etc as required: |
| 471 | Providing and fixing of flow switch in MS pipe including connection etc as required:100 mm dia |
| 472 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required |
| 473 | Supplying and fixing 63 m dia,15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless steel (Grade 304) |
| 474 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a) 20 mm nominal Internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585b) 20 mm nominal internal dia gun metal globe valve &nozzlec) Drum and brackets for fixing the equipments on wall.d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m |
| 475 | Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 600 x 250 x 400 mm made out of 18 gauge MS sheet steel with front side glass, locking arrangement and painted with approved colour, With all necessary fixing accessories and installation as required as per specifications. |
| 476 | Supplying and fixing 63 mm dia gun etal short metal branch pipe ith 20 mm nominal interanal diameter size nozzle conforming to IS 903 suitable for Instantaneous connection to Interconnect hose pipe coupling as required:Stainless steel (Grade 304) |
| 477 | Supply, installation, testing and commissioning of weather proof hose boxes wall/pedestal type of size 600 x 250 x 400 mm made out of 18 gauge MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications. |
| 478 | AIR RELEASE VALVE; Supply, installation, testing and commissioning of gunmetal air release valve 25 mm with necessary fittings etc. complete. |
| 479 | Supply, installation, testing and commissioning of lever operated 25mm dia Gate/ball valve conforming to IS 9890:1981 with forged body, brass/stainless steel ball and shall be internally threaded to receive pipe connections 25mm dia |
| 480 | Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters FIRE in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckets, duly painted over a coat of primer. |
| 481 | SPRINKLERS |
| 482 | Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler |
| 483 | Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Upright sprinkler |
| 484 | Providing,fixing, testing and commissioning of 15 mm dia quatzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Horizontal side wall sprinkler |
| 485 | Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.700 mm |
| 486 | Supplying, installation, testing & commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.1000 mm |
| 487 | Providing, installation, testing and commissioning of adjustable rosette plate for 15 mm dia in white finish UL listed or FM approved complete as required: |
| 488 | FIRE BRIGADE |
| 489 | Supply, installation, testing, and commissioning of a fire brigade draw-off outlet, cast iron body, fitted with 3 Nos. gunmetal 63 mm female instantaneous inlets conforming to IS: 903, complete with non-return valves, 25 mm drain valve, flanged outlet, 3 Nos. rubber blank caps with G.I. chains, and all necessary accessories for complete installation. Please Enable Macros to View BoQ information |
| 490 | Supply, installation, testing, and commissioning of a fire brigade draw-off outlet, cast iron body, fitted with 3 Nos. gunmetal 63 mm female instantaneous inlets conforming to IS: 903, complete with non-return valves, 25 mm drain valve, flanged outlet, 3 Nos. rubber blank caps with G.I. chains, and all necessary accessories for complete installation. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail