| Sl. No. | Item Description |
| 1 | UPSTAIR OF NEWLY CONSTRUCTED RDO QUARTERS |
| 2 | 50.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete |
| 3 | 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 4 | 5.22A.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 5 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 6 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 7 | 50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 8 | 12.48Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominalthickness and of approved size and as per approved pattern on steel frame workcomplete (steel frame work to be paid separately) |
| 9 | 12.49Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mmthickness and of approved pattern on steel frame work complete (steel frame work tobe paid separately ). |
| 10 | 12.51.1Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm(+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns using self drilling/ self tapping screwscomplete:Ridges plain (500-600 mm) |
| 11 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 12 | 9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately).Second class teak wood |
| 13 | 9.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 14 | 9.5.1.1Providing and fixing panelled or panelled and glazed shutters for shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hingesbright finished of required size with necessery screws, excluding panelling which willbe paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters |
| 15 | 9.9.1.2Providing and fixing glazed shutters for door, windows and clerestory windows using4 mm thick float glass panes including ISI marked M.S. Pressed butt hinges brightfinished of required size with necessary screws. Second class teak wood30 mm thick |
| 16 | 9.53Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) |
| 17 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 18 | 11.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 19 | 12.31.2Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap inbetween and reinforced with rabbit wire mesh fixed to wooden frame (frame work tobe paid separately) :Curved surfaces |
| 20 | 9.119Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wallthickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred atcorners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. squaretube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. squaretube of 19 gauge, EPDM rubber gasket weather seal to be provided through out theframe. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer's specification and direction of Engineer-inCharge. |
| 21 | 9.120.1Providing and fixing factory made panel PVC door shutter consisting of frame madeout of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primersof approved make and manufacture. M.S. frame covered with 5 mm thick heatmoulded PVC 'C' channel of size 30 mm thickness, 70 mm width out ofwhicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both sideforming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall betapered in 45 degree on th inner side to form top and bottom rail and 115 mm widePVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on bothsides to form lock rail. Top, bottom and lock rails shall be provided both side of thepanel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insertfor top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to befitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm +2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined togetherwith solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width isto be stuck on the interior side of the 'C' Channel using PVC solventadhesive etc. complete as per direction of Engineer -in-charge, manufacture'sspecification & drawing.30 mm thick plain PVC door shutters |
| 22 | 13.80Providing and applying white cement based putty of average thickness 1 mm, ofapproved brand and manufacturer, over the plastered wall surface to prepare thesurface even and smooth complete. |
| 23 | 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 24 | 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) |
| 25 | 13.62.1Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture . |
| 26 | 13.68.1French spirit polishing:Two or more coats on new works including a coat of woodfiller |
| 27 | 9.63.2Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barreltype) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)200x10mm |
| 28 | 9.76Providing and fixing bright finished brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete |
| 29 | 50.9.15.5Providing and fixing iron hooks and eyes: 100 mm |
| 30 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and makingcurvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners, stainless steel bolts etc., of required size on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 31 | OD324494/2025-2026Providing and fixing 12 mm thick frameless toughened glass of approved brand andmanufacture, including providing and fixing required fittings, all complete as perdirection of Engineer-in-charge |
| 32 | 17.81Providing and fixing floor mounted, white vitreous china single piece, double trapssyphonic water closet of approved brand/make, shape, size and pattern includingintegrated white vitreous china cistern of capacity 10 litres with dual flushing system,including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts andgasket etc including making connection with the existing P/S trap, complete in allrespect as per directions of Engineer-in-Charge. |
| 33 | 17.7.4Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 34 | 18.15.2Providing and fixing brass bib cock of approved quality :20 mm nominal bore |
| 35 | 18.22.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter |
| 36 | 18.58.2.1Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 37 | 50.18.8.2.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 20 mm pipe10 Kgf/ cm2 |
| 38 | 50.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2 |
| 39 | 50.18.8.6.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe6 kgf/cm2 |
| 40 | 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 41 | 50.18.9.16.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 6Kgf/cm2 - External work - Exposed on wall |
| 42 | 50.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 43 | 50.18.9.6.2Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per directionof Engineer in Charge. 50 mm dia 6 Kgf/cm2 |
| 44 | 50.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per directionof engineer in charge.110 mm dia 6Kgf/cm2 |
| 45 | CAMP OFFICE |
| 46 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 47 | 60.7.1DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonrywith good quality blasted rubble including packing to compactness to lines and levelscost and conveyance of all materials labour charges etc. complete as per direction ofDepartmental officers at site |
| 48 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 49 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 50 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 51 | 50.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete |
| 52 | 50.6.2.1Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cmor nearest available size confirming to IS 2185 part I of 1979 for foundation andplinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete |
| 53 | 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (ZoneIII) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 54 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 55 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 56 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 57 | 5.9.16.1Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 58 | 5.22A.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more |
| 59 | 50.10.2Steel work for purlin/single section with G I pipes including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete |
| 60 | 12.48Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominalthickness and of approved size and as per approved pattern on steel frame workcomplete (steel frame work to be paid separately) |
| 61 | 12.49Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mmthickness and of approved pattern on steel frame work complete (steel frame work tobe paid separately ). |
| 62 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 63 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 64 | 11.48.2Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kgof resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 600x600 mm |
| 65 | 9.1.1Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paidfor separately).Second class teak wood |
| 66 | 9.53Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) |
| 67 | 9.5.1.1Providing and fixing panelled or panelled and glazed shutters for shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hingesbright finished of required size with necessery screws, excluding panelling which willbe paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters |
| 68 | 9.9.1.2Providing and fixing glazed shutters for door, windows and clerestory windows using4 mm thick float glass panes including ISI marked M.S. Pressed butt hinges brightfinished of required size with necessary screws. Second class teak wood30 mm thick |
| 69 | 9.119Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wallthickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred atcorners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. squaretube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. squaretube of 19 gauge, EPDM rubber gasket weather seal to be provided through out theframe. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer's specification and direction of Engineer-inCharge |
| 70 | 9.120.1Providing and fixing factory made panel PVC door shutter consisting of frame madeout of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primersof approved make and manufacture. M.S. frame covered with 5 mm thick heatmoulded PVC 'C' channel of size 30 mm thickness, 70 mm width out ofwhicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both sideforming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall betapered in 45 degree on th inner side to form top and bottom rail and 115 mm widePVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on bothsides to form lock rail. Top, bottom and lock rails shall be provided both side of thepanel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insertfor top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to befitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm +2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined togetherwith solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width isto be stuck on the interior side of the 'C' Channel using PVC solventadhesive etc. complete as per direction of Engineer -in-charge, manufacture'sspecification & drawing.30 mm thick plain PVC door shutters |
| 71 | 9.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 72 | 50.9.15.5Providing and fixing iron hooks and eyes: 100 mm |
| 73 | 9.63.2Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barreltype) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)200x10mm |
| 74 | 9.76Providing and fixing bright finished brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete |
| 75 | 9.66.1Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992with necessary screws etc. complete : (Copper oxidized as per IS : 1378).125 mm |
| 76 | 12.31.2Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap inbetween and reinforced with rabbit wire mesh fixed to wooden frame (frame work tobe paid separately) :Curved surfaces |
| 77 | 13.26Providing and applying plaster of paris putty of 2 mm thickness over plastered surfaceto prepare the surface even and smooth complete. |
| 78 | 13.43.1Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 79 | 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 80 | 13.62.1Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture |
| 81 | 13.68.1French spirit polishing:Two or more coats on new works including a coat of woodfiller |
| 82 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and makingnecessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 83 | 17.81Providing and fixing floor mounted, white vitreous china single piece, double trapssyphonic water closet of approved brand/make, shape, size and pattern includingintegrated white vitreous china cistern of capacity 10 litres with dual flushing system,including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts andgasket etc including making connection with the existing P/S trap, complete in allrespect as per directions of Engineer-in-Charge. |
| 84 | 17.2.1Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, includingflush pipe, with manually controlled device (handle lever), conforming to IS : 7231,with all fittings and fixtures complete, including cutting and making good the wallsand floors wherever required:W.C. pan with ISI marked white solid plastic seat andlid |
| 85 | 17.7.4Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Flat backwash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 86 | 17.28.1.1Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete. Semi rigid pipe32 mm dia |
| 87 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of siteEngineer-in-charge |
| 88 | 17.73.1Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleatswith CP brass screws with concealed fitting arrangement of approved quality andcolour450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm. weighing not less than 170 gms |
| 89 | 17.32.2Providing and fixing mirror of superior glass ( of approved quality) and of requiredshape and size with plastic moulded frame of approved make and shade with 6 mmthick hard board backing :Rectangular shape 453x357 mm |
| 90 | 18.58.2.1Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 91 | 18.65Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102mm, height of 75 mm with concealed fittings arrangements, weighing not less than106 gms |
| 92 | 18.22.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter |
| 93 | 18.49.1Providing and fixing C.P brass bib cock of approved quality conforming to IS:8931.15 mm nominal bore |
| 94 | 18.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming toIS standards and weighing not less than 690 gms.15 mm nominal bore |
| 95 | 18.53.1Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore |
| 96 | 18.33.1Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm topdiameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid andRCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 finesand: 10 graded stone aggregate 40 mm nominal size) and inside plastering withcement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floatingcoat of neat cement complete as per standard design:With common burnt clay F.P.S(non modular) bricks of class designation 7.5 |
| 97 | 50.18.7.2.1Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00metre spacing. This includes jointing of pipes & fittings with one step PVCsolvent cement and testing of joints complete as per direction of Engineer-in-Charge20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall |
| 98 | 50.18.8.2.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chased and making good the wall etc. 20 mm pipe12 Kgf/cm2 |
| 99 | 50.18.9.12.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 20 mmdia 12 Kgf/cm2 - External work - Exposed on wall |
| 100 | 50.18.7.3.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer- in- Charge 25 mmdia 12 Kgf/cm2 - Internal work - Exposed on wall |
| 101 | 50.18.8.3.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe12 kgf/cm2 |
| 102 | 50.18.8.4.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe10Kgf/cm2 |
| 103 | 50.18.7.4.2Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00m spacing. this includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 6 Kgf/cm2 - internal work- Exposed on wall |
| 104 | 50.18.9.14.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 10 Kgf/cm2 - External work- Exposed on wall |
| 105 | 50.18.7.5.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at1.00m spacing. This includes jointing of pipes & fittings with one step PVCsolvent cement and testing of joints complete as per direction of Engineer-in-Charge40 mm dia 10 Kgf/cm2- Internal work- exposed on wall |
| 106 | 50.18.8.6.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe10 kgf/cm2 |
| 107 | 50.18.8.7.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2 |
| 108 | 50.18.9.16.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge 50 mmdia 10Kgf/cm2 - External work - Exposed on wall |
| 109 | 50.18.9.7.1Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching refilling & testing of joints complete as per direction ofEngineer in Charge. 63 mm dia 6Kgf/cm2 |
| 110 | 50.18.9.17.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 mspacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 63 mm dia 6Kgf/cm2 - External work - Exposed on wall |
| 111 | 50.18.9.20.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Elbow |
| 112 | 50.18.9.20.2Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 113 | 50.18.9.20.3Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Door Elbow |
| 114 | 50.18.9.20.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Bend |
| 115 | 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipesincluding jointing with PVC solvent cement - 63x63x63 mm dia Tee |
| 116 | 50.18.9.20.6Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63x63x63 mm dia Door Tee |
| 117 | 50.18.9.20.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia vent cowl |
| 118 | 50.18.9.20.9Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes,including jointing with PVC solvent cement-63 mm dia Socket /coupling |
| 119 | 50.18.9.21.10Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75x63 mm dia Reducer |
| 120 | 50.18.9.18.1Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 mspacing. This included jointing of pipes with one step PVC solvent cement and testingof joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 -External work- Exposed on wall |
| 121 | 50.18.9.21Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Elbow |
| 122 | 50.18.9.21.2Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 123 | 50.18.9.21.3Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 124 | 50.18.9.21.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Bend |
| 125 | 50.18.9.21.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75x75x75 mm dia Tee |
| 126 | 50.18.9.21.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee |
| 127 | 50.18.9.21.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 128 | 50.18.9.21.9Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Socket /coupling |
| 129 | 50.18.9.22.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee |
| 130 | 50.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per directionof engineer in charge.110 mm dia 6Kgf/cm2 |
| 131 | 50.18.8.9.1Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 132 | 50.18.9.19.1Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00m spacing . This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge 110 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 133 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow |
| 134 | 50.18.9.22.2Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 135 | 50.18.9.22.3Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 136 | 50.18.9.22.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 137 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 138 | 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 139 | 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 140 | 50.18.9.22.11Providing and fixing PVC moulded fittings/accessories for Rigid PVCpipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 141 | 18.17.1Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :25 mm nominal bore |
| 142 | 18.17.2Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :32 mm nominal bore |
| 143 | 18.17.3Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) :40 mm nominal bore |
| 144 | 18.18.3Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:25 mm nominal bore |
| 145 | 12.41.1Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mmdiameter |
| 146 | 9.160.1Providing and fixing skirting with pre-laminated medium density fibre boardexterior grade (Grade-I) conforming to IS: 14587:1998 marked, with (one sidedecorative and other side balancing lamination and edges to be sealed withPVC edge bending tape 2.00 mm thick of approved brand with necessary fixingarrangements and screws, including drilling necessary holes for rawl plugsetc. all complete.18 mm thick |
| 147 | 9.115providing and fixing powder coated telescopic drawer channels 300 mm long withnecessary screws etc. complete as per directions of Engineer -in-charge. |
| 148 | 9.59.3Providing and fixing ISI marked oxidised M.S. single acting spring hinges withnecessary screws etc. complete. (Copper oxidized as per IS 1378).100mm |
| 149 | 9.79.1Providing and fixing special quality bright finished brass cupboard or ward robe lockswith four levers of approved quality including necessary screws etc. complete.40 mm |
| 150 | 9.81.2Providing and fixing bright finished brass handles with screws etc. complete:100 mm |
| 151 | MODIFICATION OF COMPOUND WALL AND LANDSCAPING WORKS |
| 152 | 15.10.2Dismantling dressed stone work ashlar face stone work, marble work or precastconcrete work manually / by mechanical means including stacking of serviceable anddisposal of unserviceable material within 50 metres lead as per direction of Engineerin-Charge:In cement mortar |
| 153 | 2.8.1Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil |
| 154 | 7.1.1Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarsesand) |
| 155 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 156 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 157 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 158 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 159 | 5.9.16.1Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 160 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 161 | 50.6.1.5Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete |
| 162 | 10.25.2Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works |
| 163 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 164 | 13.88Removing white or colour wash by scrapping and sand papering and preparing thesurface smooth including necessary repairs to scratches etc. complete. |
| 165 | 13.43.1Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface:Water thinnable cement primer |
| 166 | 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Twoor more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm) |
| 167 | 13.62.1Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture . |
| 168 | 16.91.1Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.60mm thick cementconcrete paver block of M-35 grade with approved colour, design & pattern. |
| 169 | 50.2.26.1Filling with contractor own earth (excluding rock) in open areas in layers notexceeding 20 cm in depth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-incharge |
| 170 | 16.69Providing and laying at or near ground level factory made kerb stone of M-25 gradecement concrete in position to the required line, level and curvature jointed withcement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with orwithout grooves ( thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as perdirection of Engineer-in-charge ( length of finished kerb edging shall be measured forpayment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 171 | Electronics works |
| 172 | LS Amount for Electronics works |
| 173 | Unforseen Items Please Enable Macros to View BoQ information |