Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed: All Kinds of soil All Kinds of soil |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 4 | Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soil |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 8 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 10 | Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 11 | Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 12 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete |
| 13 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete |
| 14 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 16 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 17 | Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 19 | Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsAbove 20 cm wide |
| 20 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreThermo - Mechanically Treated bars of grade Fe-500D or more |
| 21 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 22 | Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 23 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 24 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 25 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of I st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 26 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 27 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete: 250x10 mm |
| 28 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete: 200x10 mm |
| 29 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 30 | Providing and fixing bright finished brass handles with screws etc. complete: 125 mm |
| 31 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 125 mm |
| 32 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 33 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 34 | Providing and fixing to existing door frames. 30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. |
| 35 | Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer -in-charge (Dash fastener to be paid for separately ). |
| 36 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge (panneling to be paid for separately). |
| 37 | Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size. made out of 20 SWG G.I. sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-charge-With clear fire resistant glass panes 6 mm thick of approved brand, having minimum 60 minutes fire resisitance |
| 38 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 39 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series)frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). |
| 40 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: 5.5mm thick glass pane |
| 41 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/ wooden frames with rawl plugs screws etc |
| 42 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-charge Extruded section profile size 42x50 mm |
| 43 | Providing and fixing to existing door frames 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. |
| 44 | Supplying and fixing PVC / fibre / chicken mesh nets as crack deterrent on joints of walls (between concrete and masonry) by pasting using cement paste- the minimum width of net shall be 50mm on each side of horizontal / vertical joint |
| 45 | 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand) |
| 46 | 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:4 ( 1 cement : 4 fine sand) |
| 47 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 48 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) |
| 49 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 50 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. |
| 51 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 500x500 mm. |
| 52 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 500x500 mm |
| 53 | Providing and fixing 10 mm thick acid and /or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile |
| 54 | Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm |
| 55 | Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge. Granite work |
| 56 | Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 57 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 58 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 59 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer |
| 60 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 61 | Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on the G.I. Base plate of size 100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5mm welded with GI fully threaded stud 16 mm outer diameter with two GI check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Guages: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with light weight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 Kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50 kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 450 mm Finished Floor Height (FFH). |
| 62 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. |
| 63 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 64 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 65 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete. |
| 66 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap |
| 67 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 68 | Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 69 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 70 | Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 71 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore |
| 72 | Providing and fixing PTMT grating of approved quality and colour. Circular type 125 mm nominal dia with 25 mm waste hole |
| 73 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931 15 mm nominal bore |
| 74 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore |
| 75 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 |
| 76 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2 |
| 77 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 |
| 78 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2 |
| 79 | Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2 |
| 80 | Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2 |
| 81 | Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2 |
| 82 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 6Kgf/cm2 |
| 83 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2 |
| 84 | Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2 |
| 85 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 86 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 10Kgf/cm2 External work- Exposed on wall |
| 87 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall |
| 88 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 89 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall |
| 90 | Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall |
| 91 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 4 Kgf/cm2 - External work - Exposed on wall |
| 92 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow |
| 93 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow |
| 94 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 95 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 96 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 97 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 98 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling |
| 99 | Providing and fixing PVC floor trap of size up to (150mm x 150mm) |
| 100 | Providing and fixing PVC gully trap (150mm x 150mm) |
| 101 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg): With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 102 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 103 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 104 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 105 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 106 | Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete |
| 107 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 I. Sand filling |
| 108 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 109 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 110 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 111 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreThermo - Mechanically Treated bars of grade Fe-500D or more |
| 112 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 113 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 114 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 115 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm) |
| 116 | 12 mm cement plaster of mix: 1:4 ( 1 cement : 4 fine sand) |
| 117 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil |
| 118 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 119 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 120 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 121 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 |
| 122 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 123 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 124 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 125 | 12 mm cement plaster finished with a floating coat of neat cement : 1:3 (1 cement : 3 fine sand) |
| 126 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 127 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 128 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 129 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 130 | Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2 |
| 131 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 132 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 133 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing ofjoints complete as per direction of Engineer in Charge. 50 mm nominal dia Pipes |
| 134 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes |
| 135 | METERING PANEL SITC of wall mounting type Metering Board made from 1.6mm CRCA sheet providing necessary supports made from the same gauge CRCA sheet to fix meters, fuse units, CT, MCCBs etc. hinged double door construction for the front side with compartments, knock out for cable entry and exit, provision for fixing seals at each chamber, painting the entire board with two coats of synthetic enamel paint over a coat of zinc chromateprimer etc. as required including fixing it on wall/floor, making good the damages colour washing etc. as required. Comprising the following: 1. Metering enclosure with glass lid for viewing from the front side, three numbers 20A backlite control fuse, three numbers, 100/5A, Cl-0.5s, 10VA CT, control wiring etc. complete. 2. MCCB chambers 125A. 4pole, 25kA MCCB with rotary handle, spreader and three nos 160A cut out fuse etc complete3. 125A 4P Change over switch with indication lamp |
| 136 | DIESEL GENERATOR SET Supply installation testing and commissioning of of 3phase., 82.5kVA 433V, 0.8pf. 50Hz, 1500rpm DG Prime Rated Diesel Generator Sets as detailed below and as shown on drawings. Water cooled diesel generating set comprising of diesel engine, alternator, fuel tank, starting system, battery, battery charger,electronic governor, etc. with all accessories as required. The generator set shall have an integral type acoustic enclosure as per latest CPCB IV norms. Smoke exhaust emission from diesel engine shall comply with the latest emission standards. Generator set shall be inclusive of fly wheel, flexible coupling, air cleaner, corrosion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 24V battery with charger, automatic voltage regulator instrument panel, RPM indicator, residential silencer, etc. The control panel shall be floor mounted dust and vermin proof with suitably rated, 4Pole,125A, 25kA, 4p, MCCB complete with all Protective/measuring instrument relays as per KSEI norms, CT operated surface type KWH meter control wiring, arranging testing the CT and kWh meter in the standard testing lab etc. |
| 137 | Providing, fixing of exhaust pipe line of 100 mm dia B class MS pipe suitable for 82.5kVA with accessories like flange, supports, through wall, including providing thermal insulation heat resistance painting etc complete |
| 138 | MAIN SWITCH BOARD (MSB): Supply, installation testing and commissioning of LT Floor mounted, compartmentalised dust and vermin proof, panel board fabricated using CRCA 16/14 SWG wpowder coated with two coats paint over two coats of zinc chromate primer, before painting the panel board shall be treated through 7-tank cold pre-treatment process. The panel shall be complete with all necessary switch gear, control gear, control wiring, metering, all protective relays, interlocks and instrumentation system suggested by Electrical inspectorate, etc. as required and as listed below in brief and details in technical specifications.All necessary components, rotary handle, spreader, neoprene gasket, door locking arrangements, suitable earth bus including all accessories. Incomer: 125A, 4P, ISO - 2Nos.125A, 4P, CONTACTOR - 2Nos. Bus Bar: Al busbar sized suitably for 125A TPN and 25x3 Cu Earth Outgoing:63A, TP MCB- 2No, 40A, TP MCB- 4No, 32A, TP MCB- 2Nos Metering, indication and protection relays, Auto start and auto load sharing with AMF Logic relay 1set, Control Wiring - 1Lot, Electrical and Mechanical Interlocking arrangement - 1Set, Surge Protector - 1No, AMF Relay - 1No, Multi Data Meter 3ph. 4 wire type . 2nos R Y B & ON/ OFF indication lamp for incomers with MCB. |
| 139 | Distribution Board / RCCB / ISOLATOR / MCBsSupplying and fixing following way, single pole neutral, sheet steel, MCB distributuion board, 240V, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, intrconnections,power painted including earthing etc. as required (But without MCB/RCCB/Isolator)12 way , Double door |
| 140 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way (8 + 18), Double door |
| 141 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 142 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 143 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral |
| 144 | Supplying and fixing following rating, double pole 240 V, isolator in the existing MCB DB complete with connections, testing and commisioning etc., as required 40 amps |
| 145 | Supplying and fixing following rating, four pole 415 V, isolator in the existing MCB DB complete with connections, testing and commisioning etc., as required 40 amps |
| 146 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps |
| 147 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps |
| 148 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes with SMC type weatherproof enclosure complete with connections, testing and commissioning etc. as required 32 amps. |
| 149 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 150 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 151 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.For 6 way, Double door TPN MCBDB |
| 152 | CABLESupply, testing and commissioning of the following size 1.1kV grade (AYWY/AYFY) / (XLPE) insulated PVC sheathed, armoured Aluminium conductor power LT cable confirming to IS 7098 (part 1) ammended upto date.1 x 3.5C x 95 Sq.mm. |
| 153 | Supply, testing and commissioning of the following size 1.1kV grade (AYWY/AYFY) / (XLPE) insulated PVC sheathed, armoured Aluminium conductor power LT cable confirming to IS 7098 (part 1) ammended upto date.1 x 3.5C x 35 Sq.mm. |
| 154 | Supply, testing and commissioning of the following size 1.1kV grade (AYWY/AYFY) / (XLPE) insulated PVC sheathed, armoured Aluminium conductor power LT cable confirming to IS 7098 (part 1) ammended upto date.1 x 4C x 16 Sq.mm. |
| 155 | Supply, testing and commissioning of the following size 1.1kV grade (AYWY/AYFY) / (XLPE) insulated PVC sheathed, armoured Aluminium conductor power LT cable confirming to IS 7098 (part 1) ammended upto date.1 x 4C x 10 Sq.mm. |
| 156 | LT CABLE LAYINGLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm |
| 157 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm |
| 158 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 159 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 160 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 161 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 162 | TERMINATIONSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 163 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 164 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 165 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 166 | WIRING & CONDUITSWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 167 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 168 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 169 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 170 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 171 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 172 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 173 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 174 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 175 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 176 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep |
| 177 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 100 mm deep |
| 178 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 179 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 180 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 181 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 182 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 183 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 184 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 185 | LIGHTING FIXTURESSupply and fixing of 2X2, LED Recessed mount down light with 30W with System efficiency of more than 100 lm/W and Translucent frosted diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CT of 5700k and CRI of Minimum 80. LED Driver shall be Multistage, Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 140V to 270V. |
| 186 | Supply and fixing 18W, 1FT x 1FT, IP20, LED surface/Recess mounted down light with Maximum system wattage of 18 W, System efficiency 100 lm/W and minimum system lumen output 2400 lm, White powder coated, pressure die cast aluminium housing. Luminaire shall use SMD type LED with CRI more than 80, THD less than 10% with PF more than 0.95 with inbuilt Surge Protection of 2.5KV. |
| 187 | Supply and fixing of 12W, IP20,LED Recess /surface mounted Square downlighter with Maximum system wattage of 12 W, System efficency 100lm/W and minimum system lumen output 1200 lm, White powder coated, pressure die cast aluminium housing. Luminaire shall use SMD type LED with CRI more than 80, THD less than 10% with PF more than 0.95 with inbuilt Surge Protection of 2.5KV. |
| 188 | Supply and fixing 18-20W IP20 High efficient 1.2m long LED batten surface/wall mounted Specially designed Co-extruded channel in thermally conductive material with plastic with HET diffuser. In-built electronic driver duly wired up to terminal block. CRI greater than or equal to 80, Temperature range-0 to 50DegC, Driver efficiency g85%, Power factorgreater than or equal;0.9, CT - 6500K, THDlt;20%, Surge protection 2kV, 30000 burning hours Luminaire lumen 2200 lumens (110 lm/W). |
| 189 | Supply and fixing of 10W IP20 High efficient 0.6m long LED batten surface/wall mounted Specially designed Co-extruded channel in thermally conductive material with plastic with HET diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI greater than or equal;80, Temperature range-0 to 50DegC, Driver efficiencygreater than or equal;85%, Power factor 0.95, CCT - 6500K, THDlt;20%, Surge protection 2kV, 30000 burning hours Luminaire lumen 1000 lumens (100lm/W). |
| 190 | Supply of Integral, SMD LED, IP 66, 9W, LED Surface mounted Die cast Alumium Bulk head fixture with System efficacy of more than 70 lm/W. Luminaire shall have Polycarbonate high transmitivity diffuser for Uniform illumination and wider light distribution. LED luminaire shall have specially design aluminum heat sink for excellent heat dissipation, good air circulations as well as very light weight.The luminaire should have inbuilt SPD -2.5KV with CRI more than 70, Power factor 0.95 , THD less than 10%. |
| 191 | Supply installation testing and commisioning of 30W street light including 32 mm GI pipe ,1.5 meter for support- Garnet LED light cool white and all accessories complete |
| 192 | CEILING FAN/EXHAUST FANSSupply installation, testing commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 193 | Supply, installation, testing commissioning of 300mm sweep heavy duty exhaust fan in metal frame working on 230V A/C.The work shall include making the holes suitable for the size of fan, fixing necessary bolt and nuts making good the damages, etc. and giving connection with required length of 1.5sq.mm., 3 core PVC insulated and PVC sheathed copper conductor flexible wire conforming to ISS, etc. as required. |
| 194 | Supply installation of wall fan, 450 mm sweep, 230V, 1Ph, plastic body and blades, pull cord for speed regulation, thermal overload protection for motor, min speed (rpm) & 1200, min air delivery (CMM) & 75 complete with all mounting accessories as required |
| 195 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 196 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 197 | EARTHINGEarthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 198 | Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 199 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 200 | Providing and fixing 10 SWG dia Copper wire on surface or in recess for loop earthing as required. |
| 201 | MISCELLANEOUS ITEMSSupply of 3mm thick synthetic type electrical grade mat |
| 202 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 203 | Supply and fixing of outdoor terminal box(syntex type) Suitable for fixing Isolators/ circuit brakers (GS-JB-3126) complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation Size:250X250X155 |
| 204 | ELV SERVICE - DATA SYSTEMSupplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. One run |
| 205 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. Two run |
| 206 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. Three run |
| 207 | Supply and fixing of GI modular box including modular face plates, fixing of RJ 45 outlets and termination of Cat 6 cables on the outlets |
| 208 | Supply installation testing and commissioning of 16 Port fully-loaded patch panel with necessary mechanical supports |
| 209 | Supply and installation of wall mounted 12 U rack including cable manager, power supply units etc.to accommodate ehternet switch and fiber patch panel at each floor |
| 210 | ELV SERVICE - TELEPHONE SYSTEMSupplying and drawing 2 pair, 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required. |
| 211 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket |
| 212 | Supplying, installation, testing & commissioning of ordinary telephones with connecting cords (minimum length of 2 metres) having a necessary connector at both ends |
| 213 | Supply,fixing and termination of 10 pair telephone terminal block housed in engineering plastic box with transparent hinged door |
| 214 | Supply, installation, testing and commissioning of Analogue type EPABX suitable for 4nos trunk lines with CLI and Power Failure Transfer and with Protection modules, 8 Analog Extensions with CLI Expandable to 108 Ports with operator console, 1 no PRI,100 pair MDF(wall mountable) including Software, Supports, necessary charger etc as complete. |
| 215 | ELV SERVICE - CCTV SYSTEMSupply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Indoor Dome Camera, 1/2.8\\" 4 Megapixel progressive scan CMOS, should support upto 30fps, triple stream, Min. Illumination required 0.005Lux @f/1.6, B/W:0Lux@f/1.6(IR on), 120dB True WDR, Min. Pixels 1920x1080, triple stream, 2.7-13.5 mm MFZ, DC IRIS, optical zoom 5x lens F1.6, Backlight Compensation, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with upto 20m IR distance, H.265+, H.265, H.264 and MJPEG, Inbuilt Video Analytics : Tripwire/IntrusionTrace, Object Left Behind, Object removed. Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, IP 66, Alarm: 1 In & 1out, PoE Class 3/ 12V DC/24VAC, Die-Cast Aluminium Construction, Having Operating temp range : –30°C to 60°C. Certifications: ONVIF Profile S & Profile G compliant, UL CAP cybersecurity certification, UL, CE, EN, FCC & RoHS compliant including all mounting accessories as required. |
| 216 | Supply, installation, testing and commissioning of IP Network Video Recorders 8channel with 8 ports, 4 HDD, 8 PoE, 4K H. 265, 2 SATA, audio 1 input 1 output, video 1 HDMI 1 VGA, recording resolution 5MP/3MP/1080P, 720P/ D1 @ 30 fps, network throughput 200 Mbps from IPC and 128 Mbps to Client, Smart search supported, Remote access by DDNS & P2P, 4 channel alarm input and 2 channel relay output, 2 USB ports, ONVIF, UL & CE certified. |
| 217 | Supply, installation, testing and commissioning of 8- Port 10/100/1000 Mbps Base - T PoE + 4- Gigabit Combo ports, 120Watts, 8 port- Edge PoE switch with all required accessories. |
| 218 | Supply, Installation, Testing & Commissioning of minimum 32 inch full HD LED monitor with resolution 1920X1080 pixel including wall mounting accessories as required. |
| 219 | Supply, installation, testing and commissioning of Surveillance / SATA compatible Hard Disk of 6 TB capacity to achieve the total storage for the NVR server |
| 220 | ELV SERVICE - ACCESS CONTROL SYSTEMSupply, installation, testing & commissioning of Single door card Class Reader (Bluetooth Enabled) with software, door latch, push button (rear side), NO/NC contacts,power supply unit, TCP IP connectivity with tamper detection provision ,relay outputs,Tema Access Remote Terminal unit including all acessories suitable for operation |
| 221 | Supply of smart cards for the access. |
| 222 | Supplying, installation, testing & commissioning of Water leak Detection System, 4 Zone Water Leak Detection LCD Conventional Panel with Inbuilt Buzzer & Individual Zone, Potential Free Contact for Connecting to the BMS System Panel has Battery Backup Facility, Common Hooter, Common Relay out for Alarm and Fault Relay output Extra including all mounting accessories as required. |
| 223 | Supplying, installation, testing & commissioning of Rodent Repellent System, Microprocessor based main Panel/Controller wall mounting type with facility to connect 8-Transducers in a dedicated connection and 8 in loopedconnection including all accessories as required. |
| 224 | FIRE ALARM AND FIRE DETECTION SYSTEMSupplying, installation, testing and commissioning of micro processor based single loop, intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 64 devices (including detectors) and minimum 50 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen orother keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50hz), 48 hours back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system ( which is part of the schedule of work under SH: PA system) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol Bacnet/ Modbus over IP complete as per specifications. single Loop Analogue addressable fire alarm panel |
| 225 | Supplying laying of 2x1.5 Sq.mm fire alarm armored cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armoring FRLS outer sheath, including termination of cable at both ends complete as required. |
| 226 | Supplying, installing and commissioning Portable Fire extinguishers of following type capacity. All to be confirmed to latest BIS codes(IS 2878:2004):-Carbon-di- oxide type fire extinguisher of 4.5 kg. Capacity, CO2 gas filled in brand new seamless cylinder with powder coated finish, with wheel type valve, discharge nozzle, bend horn, wall mounting bracket, signages etc. complete. |
| 227 | Supplying, installing and commissioning Portable Fire extinguishers of following type capacity. All to be confirmed to latest BIS codes(IS 15683:2006):-ABC powder type fire extinguisher of 6 Kg. Capacity, with initial filling in brand new cylinder with powder coated finish, high pressure, discharge hose, wall mounting bracket, signages etc. complete. |
| 228 | Providing and installing in position the following type of sign boards made out of 3mm thick PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE",'DO NOT USE LIFT" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 meters from finished floor near Manual call points. |
| 229 | Supplying, installation, testing commissioning of intelligent analog addressable photothermal detector complete with ounting base complete as required. |
| 230 | Supplying, installation, testing commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 231 | Supplying, installation, testing commissioning of addressable manual call point with break glass type complete as required. |
| 232 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 233 | Supplying, installation, testing & commissioning of fault isolator module complete with base as required. |
| 234 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 235 | Supplying, installation, testing commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 236 | Supplying, installation, testing commissioning of clean agent fire extinguisher |
| 237 | HVAC Supply, Installation, Testing amp; Commissioning of Variable Refrigerant Flow (VRV/VRF) type outdoor air-conditioning system which consists of inverter scroll compressors, condenser fan, motor condenser coils. The heat exchanger shall be comprised of aluminum fins mechanically bonded on copper tubing. The outdoor units shall be of Inverter scroll type capable of changing the rotating speed to follow variations in cooling load and shall be suitable for connecting multiple indoor units of different capacities types as per the drawing and project requirements. The aluminum fins shall have a factory applied Black Fin heat exchanger coating comprised of a corrosion resistant complex (Acryl+Epoxy+Melamine) resin coating designed to perform in corrosive environments such as seaside with high salt contamination and industrial cities with severe air pollution. The Black Fin heat exchanger shall include a Hydrophilic coating which minimizes moisture build up on the fin heat exchanger. The compressor shall be equipped with a BLDC (Brush Less Direct Current) motor with insulation Class B. Selected ODU models shall be equipped with top discharge fans directly driven by BLDC (Brushless Direct Current) motors. The selected unit shall be capable to deliver listed capacity at 39 Deg C ambient condition without deration. The unit shall be with non-ozone depleting refrigerant R410A. The refrigerant piping length between farthest indoor units and outdoor unit shall be possible to extend up to 175m with maximum 50m level difference. The system shall be provisioned such that, even if the power supply to any Indoor unit is cut-off, the rest of the system shall be able to continue to function normally. The vendor shall select all the units suitable for nominal capacity suitable for maximum outdoor temperature of 36 degC and suitable for indoor temperature of 22+1deg C. 8HP |
| 238 | Supply ,Erecting, Testing and commissioning of VRF/VRV Ceiling Mounted Cassette Type AC Units suitable to operate at 48°C ambient temperature comprising of Combination of hermetic inverter compressors, Matching air cooled condenser with copper tubes and aluminium fins duly covered by anticorrosion and hydrophillic resin film, complete with high/low pressure cut-outs, oil pressure failure switch, fan motor, safety thermostat, over current relay, fusible plugs, fuses,cabling etc.and suitable for operation on 380V~415V~3Ph~50Hz A.C. supply. Oil separator suitable for the refrigerant piping, Accumulator, liquid and gas shut-off valves and solenoid valves/modulation valve with fittings to interconnect compressor, condenser and evaporator coils, flexible connection(canvase), initial charge of R-410A Gas and Oil, frame work for mounting the above outdoor unit and thermostate its wiring, interconnecting indoor and outdoor unit using suitable refrigerent piping,refnet etc.e following capaicties of the ODU and IDU - 3.0 TR Cassette Unit with drain pump |
| 239 | Supply ,Erecting, Testing and commissioning of 4Tr, 1350 cfm 3 phase, PRECISION AC with indoor and DX type,with 4Tr high efficiency type scroll type compressor outdoor unit, 2 nos (1 working 1 standby), interconnecting indoor and outdoor unit using suitable refrigerent piping upto a distance of 15m, ducting of airline using 0.8mm thick GI duct of 12sqm,an automated system shall be programmed to alternate between both the primary and standby units including all acessoceries like dampers, Aluminium grill, insulated ducts, supporting structures, plenum, etc complete |
| 240 | Supply, installation, testing and commissioning of inverter type 5 star rated high wall mounted split type airconditioners unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc, suitable for operation on 230V 10%,50Hz,single phase AC supply, complete as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. This price inclusive of outdoor unit with necessary support, hangers and interconnecting indoor and outdoor unit using suitable refrigerent piping. CAPACITY :1 TR |
| 241 | Supply, installation, testing and commissioning of inverter type 5 star rated high wall mounted split type airconditioners unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc, suitable for operation on 230V 10%,50Hz,single phase AC supply, complete as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. This price inclusive of outdoor unit with necessary support, hangers and interconnecting indoor and outdoor unit using suitable refrigerent pipingCAPACITY :1.5 TR Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy