| 1 | Demolition of cement concrete in roof padding damaged /loosed cement concrete /bricks tiles from roof /terrace to a depth of average 50 mm including dismantling of existing treatment with APP membrane if any cleaning with water and depositng of debris outside MoD land complete all as specified and directed. |
| 2 | Cutting grooves in roof slab, brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed by Engr-in-Charge |
| 3 | M&L for plain cement concrete 1:2:4 type B-0 (using 12.50mm graded stone agg) as in roof padding over cleaned surfaces of roof for making good any depression/undulation and to obtain desired slopes complete all as specified and directed. |
| 4 | M&L for rendering 20mm thick in screed bed in cement mortar (1:3), mixed with integral water proofing liquid all as per manufacturer's instructions over concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed. |
| 5 | Supply only integral water proofing compound ISI marked |
| 6 | M&L for carrying out water proofing treatment for roofs in the following stages - (i) Material and labour for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 Itr/10 sqft in two coats (10-12 hrs gap between each coat. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must. Note: The work shall be executed by the authorized applicator of the manufacturer only. Note:- 1. The authorized applicator of manufacturer shall be approved by GE. 2. The color of final finish shall be decided by the GE |
| 7 | Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed. . |
| 8 | M&L for 10mm thick rendering in cement mortar 1:3 on concrete ceiling surfaces / sunsheds / facia / RCC chajja, finished even and smooth without using extra cement, complete all as specified and directed.Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 9 | S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/facias, Ceiling etc. complete all as specified and directed. |
| 10 | M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement, complete all as specified and as directed.Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 11 | Racking out joints/pointing to Square rubble masonry Jodhpur type regular coursed built in cement mortar complete all as specified and directed. |
| 12 | M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3 complete all as specified and directed. |
| 13 | Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by the other mean and after preparing the surfaces and applying two coat of white wash with (paint brush /with roller ) complete all as specified & directed by Engineer-in- charge |
| 14 | Material and labour for preparation of old decorated surfaces (plastered/unplastered) of ceiling by remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean with and make the surface even and smooth and applying two coat of white wash with paint brush up to the entire satisfaction of Engineer -in-Charge complete all as specified and directed. |
| 15 | Material and labour for preparation of new plastered/ concrete surface of wall / Pillars / cornices and applying 2mm thick wall care putty to complete surface of wall to make the surface even and smooth by using sander machine (With provision of dust sucking) upto entire satisfaction of Engineer-in-Charge and applying two coats of interior oil emulsion paint (with roller brush ) complete all as specified and directed. |
| 16 | Preparation of surfaces and applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. |
| 17 | M&L for applying two coats of cement based paint on newly plastered/ unplastered surface of wall including preparation and one coat of chalk white of surfaces complete all as specified and directed. |
| 18 | M&L for applying two coat of cement base paint on old surfaces including preparation complete all as specified & directed. |
| 19 | M&L for 50 to 75mm thick machine cut Sand stone slabs in sunshades, chajjas, shelves, cills, landings, manhole cover stones, templates, Plinth protection etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete complete all as specified and as directed. |
| 20 | Taking down carefully cement concrete/ spalled out concrete from RCC roof projections,Ceilings,Sunshades of beams etc upto cover depth by chipping out lightly including necessary scaffolding at height up to 7.5 mtr etc complete all as specified and directed. |
| 21 | M&L for cleaning, sweeping out loose materials from the existing reinforcement of slabs chajjas etc & applying a coat of SIKA RUSTOFF 11 or equivalent of pidilite,fosroc,Thermax etc to remove rust particles etc throughly cleaning the surface complete all as specified and directed. . |
| 22 | M&L for applying a coat of bond coat made with cement slurry (1part cement to 1.5-2parts water) mixed with admixture LATEX POWER mixed @ 5 Kg per 50kg of cement & applying to the concrete surfaces @200gm/sqm to obtain tack complete all as specified and directed. . |
| 23 | M&L for 15-20mm thick rendering in CM 1:1:2 using 1 part cement to 1part 2-3mm screenings of stone agg & 2 parts coarse sand over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE admixture equivalent of pidilite, fosroc, Thermax etc @100gm/50kg of cement & finishing the surfaces even & rough to recieve final rendering coat. |
| 24 | M&L for 10-15mm thick rendering in CM 1:3 over the bond coat applied surfeces with cement mixed SIKA PLASTOCRETE SUPER admixture @100gm/50kg of cement & finishing the surfaces even & smooth complete all as specified and directed. |
| 25 | Demolition of cement concrete (unreinforced) in ground floor and above ground floors and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and directed. |
| 26 | Material & Labour 75mm Cement concrete 1:4:8 type , D 2, using 40mm graded stone aggregates as in sub base complete all as specified and directed. |
| 27 | Supply and laying machine pressed / factory made chamfered edge cement concrete rubberised interlocking paver block, 60mm thick with 6 mm thick top layers of anti abrasive material of M-35 grade with any colour, design & pattern, & size/ shape, as approved by GE as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness made by table vibratory method using PU mould, laid in required colour & pattern over and including M&L 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 28 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cementconcrete in position to the required line, level and curvature, jointed with cement mortar1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening whereverrequired complete all as specified and directed. |
| 29 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in any type of soil/Rock complete all as specified and directed. |
| 30 | All as per item No 29.00 above but exceeding 1.5 m deep and n exc 3.0m deep. |
| 31 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. |
| 32 | Removal of excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 33 | M&L for PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base and mass conc completed all as specified and directed.. |
| 34 | Demolition and breaking up of 150 mm bore of pipe of RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches complete all as specified and directed. |
| 35 | Demolition and breaking up of 200 mm bore of pipe of RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches complete all as specified and directed. |
| 36 | Supply and laying in trenches, aligning and jointed for DWC HDPE pipe ID 150/172 mm, SN-8 laid in trenches complete with coller fixed and jointed in cement mortar and tested complete all as specified and directed. |
| 37 | Supply and laying in trenches, aligning and jointed for DWC HDPE pipe ID 200/230 mm, SN-8 laid in trenches and jointed complete with coller fixed and jointed in cement mortar and tested complete all as specified and directed. |
| 38 | Material and labour cement concrete (1:3:6) type C-2 bed to drain 150mm bore pipe including packing under and haunching against the sides of pipes for pipe after they are laid complete all as directed. |
| 39 | Material and labour cement concrete (1:3:6) type C-2 bed to drain 200mm bore pipe including packing under and haunching against the sides of pipes for pipe after they are laid complete all as specified and directed. |
| 40 | M&L For PCC type B1 (1:2:4) using 20 mm graded cushed stone agg as in coping, benching and the like incl form work complete all as specified and directed.. |
| 41 | M&L Precast RCC 1:2:4 type B1 using 20mm graded aggregates for precast cement conc slabs as in drain/ manhole covers set in cement mortar1:4. (Note : Slab covers shall be floated with surface vibrator,and over turfed base ,arrangement for turfed base has to be from contractors side) complete all as specified and directed |
| 42 | M&L for mild steel steel TMT bars 6mm to 8mm dia and over cut to length bent to shape reqd , incl cranking, bending spirally for hooping columns hooking ends and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified and directed |
| 43 | M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete ,using extra cement, incl forms moulds, mitered/stopped ends etc complete all as specified and directed |
| 44 | Dismantling of sand cast, cast iron or RCC drain pipe jointed in cement mortar of size 100mm bore complete all as specified and directed |
| 45 | All as per item No 44.00 above but 75mm dia |
| 46 | S&F 75mm dia Cast iron soil sand caste pipes, waste and vent (from gully trap to manhole) pipes in any length with or without ears, with cement joint, laid in trenches or in floors including making good to disturbed surface. |
| 47 | All as per item No. 46.00 above but fixed on wall all as specified and directed. |
| 48 | S&F 100 mm dia Cast iron soil sand cast pipes, waste and vent pipes(from gully trap to manhole) in any length with or without ears, with cement joint, laid in trenches or in floors and making good to floor dismantled during laying of pipe. |
| 49 | All as per item No. 48.00 above but fixed on wall all as specified and directed. |
| 50 | Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & as directed. |
| 51 | M&L for squared rubble walling, Jodhpur type, regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and directed. |
| 52 | Ditto all as per item No 51.00 above but here in except stone incl cleaning, sweeing etc omplete all as specified & as directed. |
| 53 | Extra over stone walling for hammer dressing for lime sand stone n.exc 40mm deep wwhen held against st edge complete all as specified & as directed. |
| 54 | M&L for PCC 1:3:6, type C1, using 20mm graded crushed stone aggregate as in surface channel and drain, post holes, beds including all necessary form work complete all as specified & directed. |
| 55 | Cutting in to existing manhole for connecting new drains,making good to pipe and rendering , cutting out existing benching and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150mm/200mm/300mm complete all as directed. |
| 56 | M&L for 15mm thick rendering in CM 1:4 finished even and smooth without extra cement on stone wall surface complete all as specified & directed. |
| 57 | S&F as in repairs of vitreous china clay water closet squatting pan ORISSA Pattern size 580x 440 mm white with integral foot rest incl 'P' or 'S' traps, flush pipe of 32mm dia HDPE pipe etccomplete all as specified & directed. |
| 58 | S & F as in repairs vitreous china wash down water closet Anglo Indian type pedestal pattern with seat & cover complete incl fixing of flush pipe etc complete all as specified and directed. |
| 59 | Supply & Fixing low level flusing cistern PVC 10 ltrs capacity with float valves (ISI Marked) white with inlet ball valve including float and includign pvc connection complete all as specified & directed. |
| 60 | M&L for cutting to bituminous road for laying of RCC hume pipe any dia & making good as per road specification and complete all as specified and as directed. |
| 61 | M&L SWR gully/floor trap 125/110mm bore, plain with grating including jointing with cement solvent cement, complete all as specified and as directed. |
| 62 | Cleaning of manholes complete of any size and at any location incl taking out sludge and other material deposited in manhole by mechanical means and its disposal to a distance n exc. 50m all as directed by Engr-in-Charge for depth of manholes as given below:- Depth of manhole n exc 1.00 M |
| 63 | Cleaning of manholes complete of any size and at any location incl taking out sludge and other material deposited in manhole by mechanical means and its disposal to a distance n exc. 50m all as directed by Engr-in-Charge for depth of manholes as given below:- Depth of manhole exc 1.00 M and n exc 2.00 M |
| 64 | Cleaning/Removal of sewage block in the existing line incl cleaning of complete line laid at any depth and at any location between two consecutive manholes for the following :-Two consecutive manhole to manhole incl testing the pipe by pouring water from manhole all as directed to the entire satisfaction of Engr-in-Charge for 150mm bore SGSW/RCC pipe . |
| 65 | All as per item above 65.00 but 200mm bore SGSW/RCC Pipe. |
| 66 | Cutting and grubbing of bushes grass and tree surrounding manholes,Gully trap, bend, wall pipe and overhead tank etc and levelling of ground around the manholes and finish the surface of wall and removing the waste material to a distance exc 50m and n exc 250m and clearing the site complete all as specified and as directed.. |
| 67 | S/F 20 mm dia of water tubing, medium grade, galvanized, with all fittings fixed to wall all as specified including taking down or up steel / PVC tubing and connection complete all as specified and directed |
| 68 | S/F 15 mm dia of water tubing, medium grade, galvanized, with all fittings fixed to wall all as specified including taking down or up steel / PVC tubing complete all as specified and directed |
| 69 | Excavating in post holes or similar holes each not n exc 0.50 cu.m, getting n.exc. 25 cm removing surplus soil to a distance not exceeding 50m and making good surface for hard and dence soil complete all as specified and as directed. |
| 70 | Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement & sand slurry 1:3 complete all as specified and as directed. |
| 71 | M & L Mild steel work as in tubular trusses, rafters, purlins, posts etc including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS - 1161-1979, Grade YST - 240, medium grade of any dia complete all as specified and as directed. |
| 72 | M&L rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) etc complete all as specified and as directed. |
| 73 | S & F Mild steel rag or lewis bolts, screwes one end, with hexagonal or square nuts and washers, the other ende enlarged exc 15 cm but not exceeding 30 cm long of 20mm dia neck bolt complete all as specified and as directed. |
| 74 | S&F Prepainted Galvalume Aluminium Zinc Coating GI based corrugated Steel Sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 75 | M&L preparation of new or previously untreated steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over & including M&L single coat of red- oxide, zinc chrome primer complete all as specified and as directed. |
| 76 | Note:- (i) Qty's have been clubbed from 3 Nos sanction Job's, whose details are encl as per appx (ii) The contract sum shall be arrived at after duducting amount of schedule of \\"Credit\\" from the Total quoted amount Please Enable Macros to View BoQ information |