| 1 | Taking down chowkhats or frame n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed. |
| 2 | Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed. |
| 3 | Taking down shutters of any description exc 1 sqm but n.exc 2 sqm and removing to store complete all as specified and directed. |
| 4 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 5 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge |
| 6 | Solid PVC board 20-22mm thick, with 2mm thick moulded prelam PVC sheet on the front face & 2mm relam PVC sheet on back with particle board core fixing in frame at site to cup board sutter, sheleves and kitchen cabinet complete all as specified and directed. |
| 7 | 18/19 thick Plywood, grade BWP, type BB fixed with screws to timber frame work, for shelf in cupboard & kitchen cabinet including wooden clit all necessary fitting complete all specified and directed. |
| 8 | Continuous (piano) hinges, mild steel bright finish, width of flap when open 30mm, as in repair complete all as specified and directed. |
| 9 | 100mm hasp and staple,aluminium anodised, including bolt to hinge plate and fixed with screws, complete all as specified and directed. |
| 10 | PVC body magnetic shutter catcher for cup boards, fixed with standard steel screws, complete all as specified and directed. |
| 11 | 100 mm size butt hinges medium weight cold rolled stainless steel complete, all as specified and directed. |
| 12 | D' type, 100mm Extruded aluminium alloy handle fabricated type complete all as specified and directed. |
| 13 | 100 mm size aluminium , barrel tower bolt of extruded section complete all as specified and directed. |
| 14 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, including making good dismantled portion with PCC (1:2:4) type B-1 in CM 1:3 complete all as specified and directed. |
| 15 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 16 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with tinned tacks / stainless steel wire staples/ aluminum beading, complete all as specified & directed. |
| 17 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm including fixed with tinned tacks / stainless steel wire staples/ FI beading including all necessary nut bolt, fixed as in repair complete all as specified & directed. |
| 18 | 4mm thick figured glass pin head type ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square n.exc 0.5 Sqm in each panes complete all as specified and directed. |
| 19 | 4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square n.exc 0.5 Sqm in each panes, including hacking out old broken glass complete all as specified and directed. |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 21 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; manhole cover; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe 165-0, complete all as specified and directed. |
| 22 | Mild steel, plain, black sheet 1.25mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. |
| 23 | Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 24 | Preparation of old steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 25 | Preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 26 | Factory made pressed steel frames of profile width 125mm x 60mm fabricated from 1.25 mm thick sheet, for doors with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. & one shop coat of primer, including filling of PCC 1:3:6 complete all as specified and directed. |
| 27 | Factory made pressed steel frames of profile width 105mm x 60mm fabricated from 1.25 mm thick sheet, for doors with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. & one shop coat of primer, including filling of PCC 1:3:6 complete all as specified and directed. |
| 28 | 30mm thick flush shutters, solid core costruction, with block board core and plywood face panels, commercial type on both sides etc. complete all as specified and directed. |
| 29 | Glazed and gauged skeleton shutter (Factory made) 30mm thick of second class hard wood open rebated & prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut & mitred beads for securing glass etc including priming coat. Size of members of shutters as specified in SSR Part I Section 8, clause 8.20 (a) including Kiln seasoned and chemically pressure treated,complete all as specified & directed. |
| 30 | preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 31 | 200 mm size aluminium , barrel tower bolt of extruded section and complete all as specified and directed. |
| 32 | D' type, 150mm Extruded aluminium alloy handle fabricated type, complete all as specified and directed. |
| 33 | Aluminum alloy, anodized, sliding door bolt 300mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. |
| 34 | 300mm mild steel ordinary rat tail rod pattern spring including roller and roller plate, including welding on chowkhat complete all as specified and directed. |
| 35 | 25mm dia stainless steel curtain rod including fixing fancy types brackets, stops, rollers etc., as in repairs complete all as specified and directed. |
| 36 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed |
| 37 | Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and pavings not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish all as specified & directed by Engineer-in-charge. |
| 38 | 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 39 | 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base finished fair and even without using extra cement, complete all as specified and directed. |
| 40 | Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 41 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 42 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 43 | All as per serial item No 42 herein before but on skirting etc over and including 10mm thick rendering in cement mortar 1:4 |
| 44 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 45 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
| 46 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 47 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 48 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. |
| 49 | Removal of excavated material to distance exceeding 250 metre but n.exc 500 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 50 | HDPE double wall corrugated (DWC) pipes (ISI Marked) 150mm SN-8 class as per IS 16098 Part -II for non pressure underground drainage and sewage applications with speials including cost of special O rubber rings couplers etc, laid in trenches on concred bed to level / gradient, jointing with appropriate class fittings as per manufacturer's instructios including jointing accessories and fittings complete all as specified and directed. |
| 51 | Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, hold fast, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed by Engineer-in-charge. - NOTE : (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately. |
| 52 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds , mitred /stopped ends etc complete all as specified & directed. |
| 53 | PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in surface channels, benching and drains complete all as specified and directed. |
| 54 | Plain cement concrete, type C-2, 1:3:6, using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under pipes and haunchng against the side of pipe and tested after the pipe are laid, complete all as specified and directed. |
| 55 | Demolition of reinforced cement concrete of any description of any description and in any position not otherwise specifically provided for, including cutting of reinforcement to facilitate demolition and removal of debris , complete all as specified and directed. |
| 56 | pre-cast reinforced cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in cover slabs (for man holes etc), shafr cover at roof level, chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc set in cement mortar 1:6, complete all as specified and directed. |
| 57 | Demolition of 25mm thick RCC louvers / jalli in shaft & other similar place and removal of debris, including all necessary scaffolding and safety arrangement complete all as specified and directed. |
| 58 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed. |
| 59 | Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. |
| 60 | Dubbing out average 20mm thick on irregular faces of walls, exposed reinforced surfaces, in Cement and Sand mortar 1:4 complete all as specified and directed |
| 61 | Rendering 5mm thick in cement mortar 1:3 on fair faces of concrete surfaces as in ceilings , finished fair and smooth, complete all as specified and directed. |
| 62 | Rendering 15mm thick in Cement and Sand mortar 1:4 over fair faces of brick / concrete ,finished even and smooth without using extra cement, including using water proofing compound, including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified. Note : WPC shall be measured and paid separately. |
| 63 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 64 | Rendering 15mm thick in Cement and Sand mortar 1:6 over fair faces of brick/concrete surfaces ,finished even and smooth without using extra cement, complete all as specified and directed. |
| 65 | Complete removal of existing wall treatement (internal / external surface) upto & including 4 storey building complete all as specified and directed. |
| 66 | Applying Wall care putty (average thickness 1-2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering for making the surfaces even and smooth complete all as specified and directed. |
| 67 | Preparing surface of wall and applying 15mm thick cement plaster in 1:4 cement sand mortar mixed with integral water proofing compound in wall surface including applying two coats of Epoxy Resin coating Polymer modified cementation coating like brush bond of Fosroc, Asian paint, Pidilite and Bostic as per manufacturers inductions on wall surface (shaft area), upto 4 storey building including all necessary scaffolding and safety arrangement complete all as specified and directed. Note : Above coated rates are inclusive of liquid water proofing compound and epoxy rasin |
| 68 | Preparation of wall or similar surface by removing all loose material, clean by wire brush and water, applying two coats of damp proof component, sure seal (Dr Fixit) or equivalent as per manufacturer instruction and applying the component by brush 1.10kg/sqm for each coat, second coat transverse direction to first coat and after 4-6 hour drying of first coat, complete all as specified and directed. |
| 69 | Preparation of wall surfaces and applying two coats of distempering (smart periodical) with I st quality nano technology based nano water based premium acrylic interior emulsion paint with unique chemical composition of finest quality, as mentioned in manufacturer manual over a coat and including of a nano priming coat on prepared old surface of wall & ceiling with using roller complete all as specified and dircted by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 70 | Preparation of wall surfaces and applying two coats of distempering (smart periodical) with I st quality nano technology based nano water based premium acrylic interior emulsion paint with unique chemical composition of finest quality, as mentioned in manufacturer manual over a coat and including of a nano priming coat on prepared old surface of wall & ceiling with using roller complete all as specified and dircted by Engr-in-Charge. Please Enable Macros to View BoQ information |