Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster/terrazo finish on brick or stone wall etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 2 | M&L for 10mm thick Rendering in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement complete all as specified and as directed. |
| 3 | M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even without using extra cement using integral liquid water proofing compound complete all as specified and as directed.Note : WPC shall be measured and paid seperately. |
| 4 | M&L for 5 mm thick Rendering in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified and as directed. |
| 5 | M&L for Preparing new plastered or unplastered surfaces of ceiling and applying two coats of white wash over 2mm wall putty , white or tinted complete all as specified and as directed. |
| 6 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 2mm thick wall care putty on new surfaces including preparation complete all as specified and as directed. |
| 7 | M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over 2 mm thick putty complete all as specified and as directed. |
| 8 | Supply only liquid water proofing compound ISI marked @ 200ml per 50Kg of cement content complete all as specified and as directed. |
| 9 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 10 | M&L for 75mm thick Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, , finished even and smooth using extra cement , laid in panels including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and as directed. |
| 11 | Dismantling of floor hearth or existing terrazo dado /flooring or tilles in bath, WC and kitchen etc complete all as specified and as directed. |
| 12 | M&L for Ultracharged Vitrified Ceramic tiles 1200mm x 600mm x 10mm thick (square /rectangular) polished as in floor on using chemical adhesives over and including 20mm thick screed bed in CM 1:4, set with chemical adhesives and pointed in white or coloured cement to match complete as specified and as directed. (Adhesive shall be measured and paid separately). |
| 13 | M&L for Ultracharged Vitrified Ceramic tiles 1200mm x 600mm x 10mm thick (square /rectangular) polished, on vertical surfaces/skirting using chemical adhesives over and including 10mm thick rendering in CM 1:4, set with chemical adhesive and pointed in white or coloured cement to match complete as specified and as directed. (Adhesive shall be measured and paid separately) . |
| 14 | M&L for light coloured Vitrified Ceramic tiles 600 mm x 600 mm x 10mm thick (square /rectangular) area of each tile not exceeding 0.36 sqm, in floors on using chemical adhesives over and including 20mm thick screed bed in CM 1:4, set with chemical adhesive and pointed in white or coloured cement to match complete as specified and as directed. (Adhesive shall be measured and paid separately). |
| 15 | All as per item No 14 here-in-before but as on vertical surfaces/skirting using chemical adhesives over and including 10mm thick rendering in CM 1:4, set with chemical adhesive and pointed in white or coloured cement to match complete as specified and as directed. (Adhesive shall be measured and paid separately) . |
| 16 | M&L for Non skid Ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors over and including 20mm thick screed bed in CM 1:4. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 17 | Demolition of stone slabs / kota / Marble in floors of any description or thickness laid, bedded and pointed in any mortar complete all as specified and as directed. |
| 18 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over and including 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 19 | M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified and as directed. |
| 20 | M&L for machine cut Kota stone slab 16 to 18mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. |
| 21 | M&L for Anti termite treatment of soil under existing floor using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and as directed. |
| 22 | M&L for Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed. |
| 23 | M&L for demolition of sunken filling concrete, removal of loose concrete and cleaning the surface and after proper cleaning filling the cracks with polymer modified mortar using Dr fixit pidicrete URP and providing 50mmx50mm angle fillets on the vertical upstands, parapet wall junction corners, service units and properly dressed by preparing polymer modified mortar with DR Fixit pidicrete URP in the ratio of 1:3 by adding polymer 10% by weight of the cement, add the water little little unit the required consistency is achieved and thereafter providing and applying two coats of acrylic polymer modified cementitious coating Dr Fixit pidifin 2K of M/s Pidilite Industrieshaving elongation at break 50% 5 bar resistance to positive water pressure, Adhesive strength ASTM D 7234-1 N/mm sq, water vapour transmission as per ASTM E96 of 030 perms and crack bridging ability as per EN 1062-7 upto 1 mm. Apply two coats of Dr Fixit pidifin 2K slurry “ coverage of 0.55-0.58 Sqm/kg of mix slurry. Provide and lay 45 gsm glass fibre mesh over the angle fillet when the first coat is still wet. Allow the first coat to dry for 6-8 hours, then apply the second coat at a direction perpendicular to first coat. Allow the coating to air cure for 5 days before conducting water ponding test for 24 hrs etc or other equivalent product as approved by GE in sunken area complete all as per the manfactures instruction, including removing rubbish material from building and thrown in low lying empty area at any distance out side MD land complete all as specified and as directed. |
| 24 | M&L for rendering 10 mm thick in cement plaster (1:3) using coarse sand finished even and smooth without using extra cement with steel trowel on sunken surfaces using integral water proofing compound complete all as specified and as directed. ( WPC shall be measured and paid separately). |
| 25 | S&F in repair Wall mounting EWC white size 515 x 360 x 350 mm (excluding flushing cistern) complete all as specified and as directed. |
| 26 | S&F in repair Concealed PVC flush cistern size 550 x 95 x 500 mm complete all as specified and as directed. |
| 27 | S&F in repair Table top Vitreous chine wash basin size 600 x 405 x 155mm including waste CP brass complete all as specified and as directed. |
| 28 | S&F in repairs Vitreous China urinals, Full stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed. |
| 29 | S&F single lever central Hole Basin Mixer 15mm bore dia with letter marked for cold and hot complete all as specified and as directed. |
| 30 | S & F in repair brass chromium plated bib cock long Nose body Fancy type with capstan screwed down for iron pipe 15 mm bore complete all as specified and as directed. |
| 31 | S & F in repair angle valve cock chromium plated fancy type half/full turn for iron pipe 15 mm bore screwed down high pressure, with capstan head, screwed both ends for iron pipe or for union complete all as specified and as directed. |
| 32 | S & F in repairs for Brass chromium plated High flow diverter including upper part of diverter, spout, hand(mobile) shower 100mm with 1.5meter shoer faucet set complete all as specified and as directed. |
| 33 | S&F 32 mm bore stainless steel bottle trap set with waste outlet pipe for wash basin/Kitchen sink with coupling complete all as specified and as directed. |
| 34 | S & F repair PVC connection 15 mm size brass nuts of length 450 mm complete all as specified and as directed. |
| 35 | S & F in repair sinks made of stainless steel kitchen sink with drainage board, plugs washers and waste copling including bedding in cement mortar to dwarf wall or including supply and fixing cantilever brackets of MS angles and connecting union to 800 mm long PVC waste flexible pipe 40 mm dia, over all size 914 mm x 460 mm x 203 mm and bowl size 405 mm x 354 mm x 203 mm complete all as specified and as directed. |
| 36 | S&F Kitchen Rack/Dish Rack (Kitchen stand or wall mounted) of size 914mmx787mmx250mm (Appx size) of Make Prayag Cat Part No P-348 or equilent made out of Food grade stainless steel 0.6 mm thick sheet/strip including necessary arrangements of plates and utensils to keep (Holds up to many plates or bowls to accommodate several place settings, Multipurpose), stylish modern streamline design, rust resistant, easy to assemble and clean including fitting accessories complete all as specified and as directed. |
| 37 | Taking up or down steel tubing and connections 15 mm bore complete all as specified and as directed. |
| 38 | Taking up or down 20mm bore steel tubing and connections, complete all as specified and as directed. |
| 39 | Supplying and laying of CPVC pipes of 20 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches, wall((100mm away from wall using sutaible clamps) complete all as specified and as directed. |
| 40 | Supplying and laying of CPVC pipes of 25 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches, walls(100mm away from wall using sutaible clamps) complete all as specified and as directed. |
| 41 | S&F CPVC Union 25mm complete all as specified and as directed. |
| 42 | S&F CPVC 25mm male/female brass threaded adaptor(FTA/FBTA) complete all as specified and as directed. |
| 43 | S&F CPVC 20mm male/female brass threaded adaptor(FTA/FBTA) complete all as specified and as directed. |
| 44 | S&F CPVC 20mm Brass Tee complete all as specified and as directed. |
| 45 | S&F in repair triple layer Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position including connecting up pipes complete all as specified and as directed. |
| 46 | S&F in repairs Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight 210 gms) complete all as specified and as directed. |
| 47 | Taking down eaves gutters and rain water PVC pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-neck etc (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 48 | Dismantling cast iron pipes of any description any dia complete all as specified and as directed. |
| 49 | S&F 110mm PVC(SWR)single pipe socketed soil waste and vent pipe in any length with rubber ring joint laid in trenches or in floors complete all as specified and as directed. |
| 50 | S&F 110mm PVC(SWR)single pipe socketed soil waste and vent pipe in any length with rubber ring joint fixed to wall(100mm away from wall using sutaible clamps) complete all as specified and as directed. |
| 51 | S&F 75 mm PVC(SWR)single pipe socketed soil waste and vent pipe in any length with rubber ring joint fixed to wall(100mm away from wall using sutaible clamps) complete all as specified and as directed. |
| 52 | S&F PVC(SWR) bends,110mm. Bore complete all as specified and as directed. |
| 53 | S&F 110mm. Bore PVC (SWR) junction single,(Single T) equal or unequal with access door complete all as specified and as directed. |
| 54 | S&F PVC(SWR) floor trap 75mm incl.CP grating jointing with solvent complete all as specified and as directed. |
| 55 | S&F PVC (SWR) 110mm to 75mm reducer complete all as specified and as directed. |
| 56 | S&F 75 mm PVC (SWR) vent cowl complete all as specified and as directed. |
| 57 | S&F 40 mm PVC single pipe socketed waste and vent pipe in any length including bend, reducer joint with solvent fixed to wall, in floor complete all as specified and as directed. |
| 58 | S & F in repair gun metal glob or gate valve with iron wheel head , crewed for iron pipe of 20 mm dia fixed in repair complete all as specified and as directed. |
| 59 | S&F in repairs Bevelled edge mirror of 5 to 6 mm thick selected quality glass, 600 x 450 mm size, mounted on 6 mm thick PVC Sheet fixed with Chromium plated brass screws and cup washers, complete all as specified and as directed. |
| 60 | S&F in repairs Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed. |
| 61 | S&F Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flangess complete all as specified and as directed. |
| 62 | S& F chromium plated soap dish Holder with round flange, fixed on wall with chromium plated brass screws and PVC plug complete all as specified and as directed. |
| 63 | S&F Corner glass shelf of size 300mmx200x150mm fancy type, toughned glass, with CP bracket and guard railing, fixed along wall with CP brass screws and PVC plug complete all as specified and as directed. |
| 64 | M&L for 25mm dia stainless steel chromium plated curtain rod incl bracket & knobs fixed in position complete all as specified and as directed. |
| 65 | Taking down window/chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each complete all as specified and as directed. |
| 66 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed. |
| 67 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprisingof virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 68 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 65 x 150 mm comprisingof virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 69 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm sizecomprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed. |
| 70 | S & F Factory made single extruded WPC (Wood Polymer Composite) skeleton door solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, ater/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed. |
| 71 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprisingof virgin PVC polymer of K value 58-60(Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and as directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 72 | Supply and fixing 100mm long stainless steel butt hinges heavy duty including steel screws for fixing complete all as specified and as directed. |
| 73 | Supply only adhesive of good quality to fix floor tiles of make Sika or equivalent out of approved makes as approved by GE complete all as specified and as directed. |
| 74 | S&F stainless steel sliding door bolt 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 75 | S&F stainless steel barrel tower bolts of extruded section 200 mm long complete all as specified and as directed. |
| 76 | S&F stainless steel barrel tower bolts of extruded section 150 mm long complete all as specified and as directed. |
| 77 | S&F stainless steel handles cast type anodised, 125 mm size complete all as specified and as directed. |
| 78 | S&F 300 mm, ordinary rat tail rod pattern springs of mild steel including roller and roller plate complete all as specified and as directed. |
| 79 | S&F Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm) Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass complete all as specified and as directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) (A) Area not exceeding 1.00 sqm each |
| 80 | S&F Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm) Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass complete all as specified and as directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) (A) Area exceeding 1.00 sqm but not exceeding 2.00 sqm each |
| 81 | Providing and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm) Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). Tprofile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.)(A) Area exceeding 2.00 sqm each |
| 82 | S&F for Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and complete all as specified and as directed. |
| 83 | S&F 5mm thick Figured glass, pin head type and glazing with beads (either supplied with shutters or to be measured separately as supply only) in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 84 | S&F 4.80mm thick Sheet glass , ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 85 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised with 40mm width of flaps (when open) and complete all as specified and as directed. |
| 86 | S & F HDHMR board, 18/19mm thick, density over 850kg/cum, having a class A fire rating, grade 2 quality, commercial type, as in cupboard complete all as specified and as directed. |
| 87 | S&F Satinless steel 100mm Hasp and staple, safety type,fixed with screws complete all as specified and as directed. |
| 88 | S&F stainless steel 125mm handle cast type, anodized complete all as specified and as directed. |
| 89 | S&F in repair Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and as directed. |
| 90 | S&F in repair Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and as directed. |
| 91 | S&F 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty/rubber gasket in square n exc 0.50 sqm in each pane for metal frames complete all as specified and as directed. |
| 92 | S&F in repair 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty/rubber gasket in square exc 0.50 sqm in each pane for metal frames complete as specified and as directed. |
| 93 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frame or stone concrete or brick surrounds glazed with putty or fixed with beads as specified and as directed. |
| 94 | S&F 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required including fixing clits, hinges and fancy type handles complete all as specified and as directed. |
| 95 | S&F Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufactures complete all as specified and as directed. |
| 96 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 97 | M&L for 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. |
| 98 | M&L for Solid PVC Wall Lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. |
| 99 | S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover,governing pivot made of brass,other parts made of mild steel heavy duty complete all as specified and as directed. |
| 100 | S&F in repair door closer of cast iron body, hydraulically regulated, designation No 2, universal type, suitable for door shutters of 701mm to 850mm wide and of weight between 36 to 60 kg, ISI marked complete all as specified and as directed. |
| 101 | S&F in repair 150 mm Floor door stopper of aluminium alloy and insulation and tounge, anodised with`hard steel spring in floor complete all as specified and as directed. |
| 102 | M&L for preparation of old interior surface of walls including complete removal of existing treatment by mechanical equipment like electric sander and applying two coats of oil bound distemper over 2 mm thick putty complete and as directed. |
| 103 | M&L for Preparing old ceiling including complete removal of existing treatment by mechanical equipment like electric sander and and applying two coats of white wash over 2mm wall putty , white or tinted complete and as directed. |
| 104 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces including complete removal of of existing treatment complete all as specified and as directed. |
| 105 | M&L for Roof treatment in as specified below and as directed:(a) Removal of existing PCC/Brick bat Coba/Mud phuska/ APP membrane from the roof stacking the reusable material and disposal of unserviceable rubbish outside the campus as direction by Egineer-in-Charge but outside in 3 km.(b) 15mm thick rendering in CM (1:4) over existing / old RCC slab / surfaces after dismantling / demo / taking down existing roof treatment.(c) Cleaning of surface of loose dust, and dirt and cement slurry etc, by means of wire brush, dust removing brush and scraper etc, Pot holes / Cracks shall be repaired with cement admixed with polymer as per manufacturer instructions.(d) Providing PCC coving / gola along vertical parapets of size 75mm x 75mm with concrete Mix (1:2:4), type B-1 using water proofing compound of approved make etc, complete as directed by Engineer-in-Charge(e) The surface shall be treated with PU Elastrol primer with Epoxy primer to seal the pores and enhance the adhesion of the coating, supplying and applying single component waterproofing liquid membrane based on pure, elastomatric, polyurethene resin cold applied of spray/brush applied membrane with an elongation of 650% +/- 50 and tensile strength not less than 2 Mpa, crack bridging ability not less than 2mm. No leakage upto 5 bars of water pressure. shore Hardness > 50 Shore.The minimum thickness to be applied shall be 1.5 mm , (overall) in two layers (each layer 750 micron) or as per manufacture's instructions so as to achieve thickness not less than 15mm.(f) Providing & laying of protective Geotextile fabric 150 GSM over the entire membrane with proper overlaps of 75mm before laying SRI roof tiles.(g) Providing and laying SRI (Sun Resistance Index) roof tiles (Size 300 x300 x 9-10mm with 20mm thick cement plaster in CM (1:4) mixed with liquid water proofing compound as per manufacturer's instructions confirming to required slope. |
| 106 | Demolition of brick work built in cement mortar including all quions arches pillars etc complete all as specified and as directed. |
| 107 | M&L for brick work with sub class B bricks straight or curved on plan exc 6m mean radius brick walls built in CM 1:6 complete all as specified and as directed. |
| 108 | M&L for Fly ash Brick work with sub class ‘B’ old burnt brick , straight or curved on plan to any radius half brick wall built in cement mortar 1:4 complete all as specified and as directed. |
| 109 | Dismantling strucural steel work including door gates but excluding framed truss etc complete all as specified and as directed. |
| 110 | M&L for MS Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete etc, confirming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 111 | M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 112 | Demolition of cement reinforced concrete as in staircase , beams chhajas and similar suspended work reinforced cut required to facilitate demolition complete all as specified and as directed. |
| 113 | M&L for RCC Design Mix of M-25 slab supported on walls beam and column in floor roof landing and like using 20 mm graded stone aggregates and complete all as specified and as directed. |
| 114 | M&L for Form work to soffits of suspended slab such as roof slab not exc 200 mm thick to rough finished surface of concrete complete all as specified and as directed. |
| 115 | M&L for Form work to edges of conc flat floor and roofs n exc 20 cm wide to rough finished surface of concrete complete all as specified and as directed. |
| 116 | M&L for Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 117 | M&L for Mild steel TMT bars8- 10mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. |
| 118 | Structural design for Existing Roof Slab, Beams, Chajja, staircase and other connected RCC members required to be re-constructed under this Schedule with & including vetting of structural design from approved Govt Engineering College/NITTTR/CBRI, complete all as specified and as directed. Notes : (i) Tenderer shall carryout the site visit to ascertain the size of slab, other RCC members, arrangement of rooms, etc required for design purpose.(ii) Four sets of Structural drawings shall be provided to GE by the contractor duly vetted as above complete all as specified and as directed. |
| 119 | MS Scaffolding:Supplying,erecting scaffolding upto required height with necessary H-frames pipes, couplers,buckles,bracings,top platform with support railing at top etc. including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same afte rworking and taking away the scaffolding materials etc. complete as per direction of Engineer-in charge. |
| 120 | Supports:Providing and erecting MS props to support the structure provisionally during dismantling and repair works and maintaining the min position till required as directed. |
| 121 | Removal of damaged concrete: Removing, chipping and cleaning of existing loose and damaged concrete carefully by low impac t high frequency hammer or by manual chipping without damaging the existing concrete or controlled sand blasting including cleaning the surface by air jet or as per direction of Engineer in charge. |
| 122 | Application of rust converter: Clean all existing reinforcement bars with wire brush / rotary wire brush and apply rus t remover solution to make entire surface of bars free from rust scales,loose material,dirt etc.Allow the applied material to react for about16-24 hours, then finishing by thoroughly washing down with clean water and completely drying the bars. The material shall have specific gravity 1.16-1.22@25°C.The application shall be as per Manufacturer's specification sand as directed by Engineer-In-charge. Make: Reebaklens RR of Fosroc or equivalent out of approved makes as approved by GE. |
| 123 | Zinc-rich Anticorrosive coating: Apply two component epoxy based zinc rich primer on the exposed reinforcement bars after the application of rust remover, including, mixing the two components of the zinc rich primer until a homogeneous mixture is obtained. The zinc rich primer shall be applied at 40 microns dry film thicknes sand shall have salt spray resistance of < 5mg for 96 hours as per ASTMB-117 and adhesive bond strength >1.5MPa as per ASTMD4541. It shall have specific gravity >1.5 and total zinc content > 67% in the dry film, etc. All application shall be as per Manufacturer's specification sand as per directions of Engineer-In-charge.Make: Nitozinc Primer of Fosroc or equivalent out of approved makes as approved by GE. |
| 124 | Fixing of packers: Clean the existing surface to remove all dirt, dust, loose materials and other contaminants, Drill holes of suitable diameters upto 20mm at an angle of 45 degree in a staggered manner across the deteriorated / cracked concrete surface, at 300-500mm center-to-center or as per site requirement. Clean the holes with air blowers and Fix NRV metal packers in the cleaned holes with epoxy putty, etc. complete all as specified and as directed. |
| 125 | Epoxy injection grouting: Providing and injecting solvent free, two part, high strength epoxy resin based injection grout using pressure injector with accessories till the packers refuses to accept the grout. The application includes mixing of component parts in adequate proportions as per manufacturer's instructions and grouting the mixed material in to the structural member through the pre-fixed injection packers by using suitable pressure pump, maintaining desired pressure. Remove the injection packers and seal with any suitable thixotropic epoxy adhesive or repair mortar after the refusal of grouting material from the packers, etc. all complete as per Manufacturer's specification sand as directed by Engineer-In-charge. Make: Conbextra EP10 of Fosroc or equivalent out of approved makes as approved by GE. |
| 126 | Additional steel reinforcement: Provide and fix TMT bars as replacement of damaged reinforcement bars and as additional reinforcement of any dia. as per site requirement all as specified & as directed, including decoiling, straightening, cutting, bending and binding with coated binding wire. The rate shall include cost of binding wire, chairs, spacers, pins, etc. which will not be measured separately for payment, etc. complete all as specified and as directed. Anchor groutforfixingofrebarsintoconcrete shall be paid under separate item. |
| 127 | Anchoring steel rebars with Anchor grout:Providing and injecting suitable anchor grout LokfixE77or equivalent for fixing new reinforcement bars in to concrete. The application includes drilling holes of suitable diameter in concrete, injecting the anchor grout in to the hole followed by inserting the steel reinforcement bars,etc. all complete as per Manufacturer's specifications and as per directions of Engineer-In-charge. |
| 128 | Shear key connectors:Providing and fixing shear connectors-8mmdia. or as specified Highyield steel rebars of specified length on the prepared concrete substrate, including drilling holes of suitable diameter sinstaggered manner across the concrete surface and fixing the shear connector bars in to the holes with chemical anchor grout Lokfix E77 or equivalent, etc. all complete as per site requirements and as directed by Engineer-in-charge. |
| 129 | Epoxy bond coat:Providing and applying high strength solvent-free epoxy resin based bonding agent for effective bonding of the new repair material to the existing concrete, including mixing of the two components-base and hardener thoroughly until a homogeneous mixture is obtained, applying with soft bristlenylonbrush on the prepared substrate where new concrete or mortar is to be placed, ensuring that the bond coat is in tacky state while placing the repair material, etc.complete all as directed by Engineer-In-charge. Make: Nitobond EP of Fosroc or equivalent out of approved makes as approved by GE. |
| 130 | Formwork/ Shuttering:Providing and fixing leak-proof shuttering, including centering, shuttering, propping, etc. all complete as per site requirement and as directed by Engineer-in-charge. |
| 131 | Microconcrete jacketing:Providing and laying high strength, non-shrink cementitious microconcrete for repairing and building up broken deteriorated concrete sections. The ready touse blend of dry powder sand selected aggregates, when mixed with clean wateronsite, produces free- flowingn on-shrink repair microconcrete. The application procedure includes mixing the dry powder contents from the bag of ready-to-mix microconcrete with adequate quantity of water as per Manufacturer's recmmendations, mixing continuously with high torquerotary drill fitted with mixing paddle, until smooth, even consisteny is achieved, and then placing the mixed material immediately in leak-proof form works, curing after removal of shuttering, etc. all as per manufacturer's specifications and as directed by Engineer-in-charge. Make: Renderoc RG of Fosroc or equivalent out of approved makes as approved by GE. |
| 132 | Waterproof coating: Providing and applying modified polyurethane hybridelastomeric water proof coating Nito proof 725 or equivalent, which is a single component, water-based, lexible and UV stable water proofing compound easy to apply with brush esorrollers. The application includes cleaning the substrate to make it free from any dust, dirt, laitance and other contaminants, followed by priming the surface by mixing the water proofing compound with clean water in 1:1 proportion and applying on the substrate. The water proof coating shall be applied when the primer coat is dry to atackystate, in two seamlesscoats,with adequate inter-coat interval and the second coat in perpendicular direction to the first coat, etc. all complete as per Manufacturer's specifications and as directed by the Engineer-In-charge. |
| 133 | M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed. |
| 134 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. |
| 135 | M&L for Providing precast cement concrete type B1, 1:2:4 using 20mm graded stone aggregate as in string course (kerb stone) with plain fair faces including chamfers, weathering complete all as specified and as directed. |
| 136 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in loose/soft soil complete all as specified and as directed. |
| 137 | Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete all as specified and as directed. (reinforcement to be measured separately) |
| 138 | Demolition and breaking up drain pipes (SGSW, AC or RCC) of internal dia 150mm, set in cement mortar complete all as specified and as directed. |
| 139 | M&L for Cement concrete 1:3:6 type C2 Concrete bed(width of bed is outer dia of pipe plus 30 cm) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 140 | M&L for DWCPE (SN8) confirming to IS-16098,150 mm Nominal bore (160 mm OD) complete laiding and jointed incl testing along with necessary jointing material tees /union /socket etc complete as per manufacture instructions complete all as specified and as directed. |
| 141 | M&L for Cutting into existing manholes for connecting new drains, _150___mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and as directed. |
| 142 | M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in lean concrete foundation complete all as specified and as directed. |
| 143 | M&L for PCC 1:2:4 mix type B-2 (40 mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed. |
| 144 | M&L for PCC 1:2:4 mix type B-1 (20 mm graded stone aggregate) as in coping complete all as specified and as directed. |
| 145 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and as directed. |
| 146 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 147 | Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and as directed. |
| 148 | Taking down old U/S existing DB SPN 8 way & TPN DB 4 way including MCB/MCCB/Sheet Metal enclosure plug socket of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. |
| 149 | Disconnecting and taking down unserviceable submain wiring form TPN DB to SPN DB and SPN DB 8 way to SPN DB 4 Way complete & removing U/S items from site complete all as spcified and as directed. |
| 150 | Taking down the old unserviceable Fan regulator from site complete all as spcified and as directed. |
| 151 | Taking out carefully earthing set complete of any type including earthing wire & removing U/S items from site complete all as spcified and as directed. Please Enable Macros to View BoQ information |
| 152 | Taking out carefully earthing set complete of any type including earthing wire & removing U/S items from site complete all as spcified and as directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy