| 1 | M&L for Excavating in post holes in hard dense soil (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thickness complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L for Cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concretecomplete all as specified and directed by Engr-in-Charge. |
| 3 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161- 1979 grade St.-240 complete all as specified and directed by Engr-in-Charge. |
| 4 | S&F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed by Engr-in-Charge. |
| 5 | S&F 1.60mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for preparing of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 7 | M&L for complete removal of existing treatement by scraping, washing, rubbing down or stopping distempered or painted surfaces etc of walls plastered or un-plastered & removing all vegetation growth, cleaning to the entire satifactory of Engr-in-Charge & applying of Birla/JK white wall putty approx 3 mm thick in two layers as per manufacturer's instructions on existing prepared surface and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed. |
| 8 | Providing & fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS8225:1987, Non combustible as per BS476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick(galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items(galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mmq dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 9 | M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed by Engineer-in-Charge. |
| 10 | M&L coloured/printed Vitrified ceramic tiles 10 mm thick, area of each tile not exc 0.36 sqm, laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of 450x300x7mm / 350x 250x 7 mm / 450X 350X 7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:3 rough finish to receive the tiles complete all as specified and directed. |
| 12 | M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch. |
| 13 | Description all as per Srl item No 12.00 here in before but for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed. |
| 14 | Description all as per Srl item No 12.00 here in before but for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed. |
| 15 | Description all as per Srl item No 12.00 here in before but for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed Please Enable Macros to View BoQ information |
| 16 | Description all as per Srl item No 12.00 here in before but for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete all as specified and directed Please Enable Macros to View BoQ information |