| 1 | SCHEDULE 'A' PART-I: B/R WORKS |
| 2 | Demolition of reinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level). |
| 3 | Demolition of brick work built in cement mortar all as specified and directed. |
| 4 | Demolition of un-reinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level). |
| 5 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 7 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil. |
| 8 | M&L for hardcore of broken stone of guage n. exc 63 mm deposited,spread and levelled in layers n. Exc 15 cm thick , water and ramed to a true surface. |
| 9 | Plain cement concrete type C2, 1:3:6 (40mm graded stone aggregate) in foundations, fillings and mass concrete. |
| 10 | M&L for 100 mm cement concrete Type B-1,1:2:4 (20mm graded aggregate) in flooring/hard standing & finished the surfaces even and smooth with using extra cement all as specified and directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 12 | Removing excavated material exc.50m but n exc.100 and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 13 | Reinforced Cement Concrete (Nominal Mix) Type A1 1:11/2:3 (using 20 mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. |
| 14 | Reinforced Cement Concrete (Nominal Mix) Type A1 1:11/2:3 (using 20 mm graded stone aggregate) in Columns, piers, posts and struts. |
| 15 | Reinforced Cement Concrete (Nominal Mix) Type A1 1:11/2:3 (using 20 mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span. |
| 16 | Reinforced Cement Concrete (Nominal Mix) Type A1 1:11/2:3 (using 20 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. |
| 17 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. |
| 18 | M&L deformed or twisted TMT bars 5 mm dia and over upto and incl 10mm, bent to shape required including cranking bending spirally for stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 19 | Fair finished flat Form work to sides of concrete foundations, footings,bases of columns,raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter. |
| 20 | Fair finished flat Form work to sides of pillars, posts, struts,piers, columns and stanchions. |
| 21 | Fair finished flat Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. |
| 22 | Fair finished flat Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping). |
| 23 | M&L Modular brick work with flyash bricks straight or curved on plan exc 6m mean radious built in cement mortar 1:6 complete all as specified and directed. |
| 24 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finishing the surface fair and even using WPC as on external surface all as directed. |
| 25 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finishing the surface fair and even. |
| 26 | M&L fo Rendering 5 mm thick on fair faces of concrete surfaces in cement mortar 1:3 and finished even and smooth without using extra cement |
| 27 | Supply only liquid water proofing compound |
| 28 | M&L for applying two coats 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 Lit/10 Sqm over newly plastered by auto roller surfaces incl preparation of surfaces. |
| 29 | M&L for Preparing new plastere surfaces providing two coats of oil bound distemper over plaster of paris putty of 2 mm thickness on wall surface to prepare the surface even and smooth all as specified and directed by Engr -in- charge. |
| 30 | M&L Preparing newly plastered surfaces of ceiling and applying three coats of white wash. |
| 31 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile of exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in cement mortar 1:4 for laying floor finishes all as specified and as directed by Engr-in-charge. |
| 32 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile of exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick cement motor 1:3 as in backing coat all as specified and as directed by Engr-in-charge. |
| 33 | M&L Chequered Cement concrete tiles 20 cm x 20 cm x25mm thick, machine pressed with grey cement and pigment; set, jointed and pointed in net cement shurry in floors, and cut and polished including 15mm thick screed bed in CM 1:6 complete all as specified. |
| 34 | SCHEDULE 'A' PART-II: E/M WORKS |
| 35 | Taking down copper/aluminium point wiring (light, fan, socket or power ) complete incl light fittings, switches, ceiling roses, pendents, regulators socket etc to be measured seperatly complete all as specified and directed by Engr-in-Charge. |
| 36 | M & L For Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through PVC Conduit concealed in Walls / Roofs / Floors / Ceiling etc. and Modular Type Pressed Metal Flush Box made out of 1mm thick GI Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Fan Point controlled by One Switch with all accessories complete all as specified. [Note- The PVC Conduit to Concealed in wall through cutting,Chassing,Pining in making good surfacing where required and pointing in cement mortar and making good for same unit rates are inculded for same] |
| 37 | All as per item No 35 here in before but one light point controlled by two 02 way switches. |
| 38 | Description all as per item No. 35 above but for5/6Amp switch socket out let, independent , complete all as specified |
| 39 | Supply and fixing Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engr-in-charge. |
| 40 | Supply and fixing of Socket, 6A - 2/3 pin combined 2 module, 230 volt, multipurpose, complete all as specified. |
| 41 | Supply and fixing ceiling rose surface bake lite 65 x 30 mm with 3 terminals complete all as specified and directed by Engr-in-charge. |
| 42 | Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall),SPN, 240 volt, 8 Way, IP-42 protection with 100 Amp rated bus bar and 6 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete all as specified. |
| 43 | Supply and fixing of MCB 6 to 32Amp, 240 Volt, SPN, breaking capacity 10 KA 'C' series, , complete all as specified |
| 44 | Supply and fixing of MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA 'C' series, complete all as specified |
| 45 | Supply and fixing LED lights fitting 18W/20W, 220V, AC decorative box type with driver including LED tube light batten fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specfied and directed |
| 46 | S & F Building Security light LED type of minimum 3500 Lumens (35 Watt) Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 40mm dia GI light grade pipe of 1.2m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge. |
| 47 | M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with Galvanize earth wire 4 mm dia by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion. |
| 48 | Supply and fixing ceiling fans complete with blades, down rods, hanging clamps and accessories, 230 V, 1200 mm sweep Five star rated with brushless direct current motor (BLDC) all as specified and directed by Engg-in Charge. |
| 49 | S & F Supply & fix Air Circulator wall mounted fans decorative type 230 volts single phase oscillating 400 mm sweep suitable for wall mounting with complete all as specified and directed by Engg-in-Charge. |
| 50 | Supply lay and testing of cable in trenches/walls XLPE insulated, armoured electric cable (heavy duty 1100volt grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed by Engr-in-charge. |
| 51 | Excavation in trenches not exc.1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for laying of cable complete all as specified.Note :- Excavation of upper layer of garden will be kept safely for refixing at same/other place all as directed. |
| 52 | Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified. |
| 53 | Removing excavated surplus soils meterial not exc.50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified. |
| 54 | S & F of metallic Exhaust fan of sweep 380mm along with metallic louver complete including cutting of wall, making of proper hole sufficient duly cement plasered to fix exhaust fan and smoothing of the surface before fixing of exhaust all as specified and directed by Engg-in Charge. Please Enable Macros to View BoQ information |