Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 A : Design and construction of Md accn for Officer (Major to Brig block of 04 Quarters) Complete all specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 3 | Item No 01 B : Design and construction of Md accn for Officer (Major to Brig block of 03 Quarters) Complete all specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 4 | Sch 'A' Part-II (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 5 | Sch 'A' Part-III (External Water supply) Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 6 | Sch 'A' Part-IV Special Item (Solar water Heater) Lump sum price worked out by the contractor for Special Item (Solar water Heater) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. |
| 7 | Sch 'A' Part-V (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 8 | Sch 'A' Part-VI (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 9 | Sch 'A' Part-VII (Security Fencing & Gate) Lump sum price worked out by the contractor for (Security Fencing & Gate) as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-VIII (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-IX (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-X (Internal Electric Supply) Lump sum price worked out by the contractor for (Internal Electric Supply) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 13 | Sch 'A' Part-XI (Internal Water Supply) Lump sum price worked out by the contractor for (Internal Water Supply) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 14 | Note for Srl No 2 to 13The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 13 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 15 | Schedule 'A' Part-XII (Miscellaneous items of works) |
| 16 | External Electric Supply |
| 17 | Item No 02 : Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 200 KVA plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014 Energy Efficiency Level 3 (latest) AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 10% to plus 5% in steps of 2.5%, continuous rating of capacity 200 KVA including cable box on HT & LT side |
| 18 | (Contd ....Item No: 02)The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.5 M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. |
| 19 | The unit rate of transfarmer shall also includes the cost of following accessories/ fittings / Misc work:- |
| 20 | (Contd ....Item No:- 02)(a) Externally hand operated off-circuit Tap switch with position indicator and locking device.(b) Conservator with oil gauge, filling hole with plug & drain hole with plug.(c) Under carriage with four plain rollers.(d) Oil filling hole cum air release plug - 01 No(e) Drain valve cum sampling valve - 01 No(f) Filter valve with plug - 01 No(g) Rating plate & Diagram plate - 01 No(h) Lifting lugs for Transformer - 02 Nos(j) Lifting lugs for lid - 02 Nos(k) Earthing terminals - 02 Nos(l) Thermometer pocket - 01 No(m) Silica gel breather - 01 No |
| 21 | (Contd ....Item No 02)(n) Temperature rise indicator in oil 40 deg centigrade and windings 45 deg centigrade.(o) Fitting accessories as per IS 1180 (Part-I) 2014 Level-3 and as per clause No 19.14.1.2 of SSR Part I.(p) Maximum losses of transformer shall be energy efficiency level 3 as per IS 1180 (Part-I) 2014.(q) Oil level gauge incl oil level min and max. (r) Exclusion vent – 01 No.(s) 6” Dial type thermometer with alarm and trip contact and maximum temp – 01 No.(t) Mounting arrangement shall be provided with two 75x40 mm channels 460mm long.(u) Suitable plinth of height 1.5M above GL for installation of transformer.(v) Cable termination box on both sides (HV Side & LV Side for cable connections ).(w) Plinth required for mounting Transformer as per above description. Note : (i) The contractor shall provide BEE certified, Level 3, Trasformer offered by the Manufacturer.(ii) The contractor shall submit preliminary drawing for approval to GE . |
| 22 | Item No 03 : M& L for cable root indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 23 | Item No 04 : M& L for cable root indicator MS sheet embossed with HT 11000 Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 24 | Item No 05 : Supply, installing, testing & commissioning factory made (CPRI approved ) outdoor type, floor mounted LT panel board cubical type suitable for 415 volts 3 phase 4 wire 50 c/s AC supply system having bus bar chamber with insulated copper bus bar of rating 600 amp for phase & neutral, installed on porcelain insulators the panel shall be dust & vermin proof IP 65 class protection & made of 3.15 mm CRCA MS sheet and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outer surface and painted inside with two coats of red oxide primer front , |
| 25 | (Contd ....Item No 05)Double door with both side opening including Neoprene Rubber Gasket, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc opening type including internal wiring with PVC insulated solid copper conductor cable 1100 volts grade of appropriate size (but not less than 6sqmm) Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following:- |
| 26 | (Contd ....Item No 05)BUSBAR :- (i) 600 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 27 | (Contd ....Item No 05)INCOMING :- |
| 28 | (a) MCCB 4 Pole 400 Amps, 36 KA - 01 No (incoming) |
| 29 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 30 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 31 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 32 | (e) Copper wound with CTR 600/5 - 03 Nos |
| 33 | OUT GOING |
| 34 | (i) MCCB 125 Amps,4 pole 25 KA, - 06 Nos.(5 Block+ 1 Standby) |
| 35 | (ii) MCCB 100 Amps,4 pole 25 KA, - 01 Nos. |
| 36 | (iii) Indicating lamp on each outgoing feeder |
| 37 | (iv) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. |
| 38 | (v) Panel drawing shall be got approved before placing of order from GE. |
| 39 | (vi) 3 Phase LED Digital Ammeter Class 1.0 |
| 40 | (vii) 3 Phase LED Digital Voltmeter Class 1.0 |
| 41 | Item No 06 : Supply, installing, testing and commissioning out door type LT feeder piller box of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, IP 65 rated,shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : -Note:- In Panel contractor has to mark that where supply is going and from where supply is comming near each MCCB/MCB and also above panel properly. |
| 42 | (Contd ....Item No 06)BUSBAR :- (i) 150 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 43 | INCOMING :- |
| 44 | (a) MCCB 4 Pole 100 Amps, 16 KA - 01 No (incoming) |
| 45 | (b) Digital Voltmeter 0 - 500 Volt with in built selector switch - 01 No. |
| 46 | (c) Digital Ammeter 0 - 250 Amp with in built selector switch - 01 No. |
| 47 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, B phase - 01 set |
| 48 | (e) Copper wound with CTR 250/5 - 03 Nos |
| 49 | OUT GOING |
| 50 | (i) MCB 4 Pole 40 Amps,16 KA at 415 volts - 02 No.(Garden Light & Street Lights) |
| 51 | (ii) MCB 4 Pole 32 Amps 16 KA at 415 volts - 01 Nos (Post top Lantern Light ) |
| 52 | (iii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 03 set |
| 53 | (iv) Auto control time switch, timer control for different 24 hours adjustable type including power contractor of rated capacity complete - 02 Nos (1 x Garden Light +1 x Security Light) |
| 54 | Item No 07 : S&F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and bolts including junction box with 6-32 A MCB of size complete all as specified & directed |
| 55 | Item No 08 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - |
| 56 | (Contd ....Item No 08)(a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 57 | Item No 09 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - |
| 58 | (Contd ....Item No 10)(a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 59 | Item No 11 : S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 60 | Item No 12 : S&F earth continuity conductor or main earth lead of 25 X 3 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 61 | Item No 13 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 250X250X155 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp with necessary nuts and bolts complete all as directed. |
| 62 | Item No 14 : Supply and fixing aluminium LM 6 pressure dia cast LED street light fitting 70 Watt 230 V AC outdoor type with high power LED source luminious efficacy 140 lm/watt, Correlated Color Temperature (Nom) 5700 K, Luminous Flux 9,800 lm, (CRI)> 70,PDC housing, moulded type Driver high impact resistance (IK 10) with PC cover & Top openable access to drivers for ease of maintenance with inbuild SPD 5KV (or nearest higher size), IP66 (Dust penetration-protected, jet - proof), median useful life L70B50 |
| 63 | (Contd ....Item No14)of 50,000 hour(s), LEd chip, driver & housing in same make complete, Additional 10 KV surge protection device, PF should be greater than 0.95 separete connector block for termination of incomming cable connection all as specified and directed. |
| 64 | (Contd ....Item No 14)Note: Warranty certificate of LED fitting should be at least 5 years and same will be produced to the department, Any defects within warranty period will be recitifed by contractor and Earth connection of each light fitting should be connected to the system earth point either with 3 core cable or through separate earth cable, fixing it in 40 mm GI bracket (pinting the bracket with one coat of red oxide and one coat of aluminum paint) and connecting it with pole mounted junction box with 2.5 sqmm 3 core copper conductor all as spcified & directed. |
| 65 | Item No 15 : Supply and errect Steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with MS base plate, finial taper plug, bolts, nuts, screws and top cover, with single swan neck bracket all as specified, directed and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 1.6 mtr deep for pole foundation and getting out in soft/loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section for 150 mm and PCC 1:3:6 type C-2, using 40mm graded stone aggregate as in foundation, 600 mm x 600 mm cross section planting depth 1.5 mtr for concrete casing the pole upto GL complete all as directed. |
| 66 | (Contd ....Item No 15)(c) Material and labour for providing PCC 1:2:4 type B-1, using 20mm graded stone aggregate for plinth block/collar above GL 300 mm high and 600 mm x 600 mm cross section all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer for preparation of surface complete all as directed. |
| 67 | Item No 16 : Material and labour for LT 1100 volts (Earthed) grade cold shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50-120 sqmm complete all as specified and as directed. |
| 68 | Item No 17 : Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying one coats of black bituminous paint complete all as specified and as directed. |
| 69 | External Water supply |
| 70 | Item No 18 : Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,80 mm (3”) dia and all as directed. |
| 71 | Item No 19 : Construction of brick masonry valve pit of size 900 mm x 900mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. |
| 72 | (Contd ....Item No 20)Construction of brick masonry valve pit of size 600 mm x 600mm x 600 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. |
| 73 | Sewage Disposal |
| 74 | Item No 21 : Supplying and laying and jointing for (SN 8) DWCPE 180mm (OD)/ 163 (ID) conforning to IS-16098:2013 part -I with and incl jointing materials complete |
| 75 | Item No 22 : M&L RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users. |
| 76 | Item No 23 : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M x 5.0 M depth complete. TD: CEJZ/TD/58 dt 5-5-2000 and CEJZ/TD/59 dt 5-5-2020 |
| 77 | Road Path Culvert |
| 78 | Item No 24 : S&F 10 mm thick vitrified paver tiles out door non skild area n. exc 0.36 sqm each as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed in CM (1:6) complete all as specified and directed. |
| 79 | Solar Water Heater |
| 80 | Item No 25 : M & L Cross arms, bracings, supports, clamps and back plates fatricated from new structural steel sections including nuts, bolts, washers. Welding, bending cold or hot, drilling holes for bolts in nay shape or size as indicated or directed by Engr-in-charge and inclusive of one red oxide metal primer coat, one under coat and one finishing coat of approved quality aluminium paint.Note: 1. Structure for PVC water tank should be as per standard engineering design and MS sheet shoul be fixed/ welded on the top of structure for placing the PVC tank.2. Contractor has to submit the design drawing of structure duly vetted from state govt engineering college and submitted to department for approval. |
| 81 | Item No 25A : Supply and install, testing and commissioning of Solar Hot Water system( Evacuated Tube collector system) based on transfer of heat of capacity 50 LPD, High quality vaccum tube made from borosilicate including power supply backup with 2kw heater following accessories all as specified and directed.(i) Solar flat plate collectors shall be constructed strictly as per norms of Ministry of Nonconventional Energy sources(MNES), govt of India and BIS specifications.(ii) Collector Support Structure:- The support structure for the collector shall be of MS angle of size not less than 50X50X6 mm. The structure shall be provided with suitable flat iron sections to fix collectors on structure and to prevent from uprooting during heavy winds. |
| 82 | (iii) Hot water storage tank along with structure and GI cladding:- Tank shall be of full capacity as per the system. Tank shall have thermal stratification to prevent mixing of hot and cold water. The tank shall be made of stainless steel sheet SS-316 L with PUF insulation and pre coated GI Cladding on outer cover.(iv) Coldwater Makeup Tank minimum capacity 100 Ltr along with supporting structure height above the 45 cm above from hot water tank to obtain sufficient pressure as per manufacturers recommendation. |
| 83 | Internal Electric supply |
| 84 | Item No 26 : S & F modular type TV Socket outlet complete all as specified and as directed. |
| 85 | Item No 27 : S & F modular LAN socket RJ 45 with complete box. |
| 86 | Item No 28 : S & F module type telephone socket RJ 11/12 with complete box. |
| 87 | Item No 29 : S & F install testing and commissioning wall mounted meter box of size 1050mm x 1050mm x 200mm depth suitable to install smart meter 04 nos in separate subcompartment made out of 2mm thick CRCA sheet duly power coated, total type tested assembly penal (CPRI Approved) as per IEC-61439-1&2-2022, provisioning of transparent glass infornt of meters compartment doors complete rubber gasket providing with locking arrangements for each meter door provision of 300 amp rating 4 nos copper bus bar chamber with insulating materials, power wiring using PVC insulated standed copper wire of size not less than 16 sqmm 4 single core including lugs from bus bar to meter and meter to control MCB with neutral wire linking to DP including following accessories :- |
| 88 | (Contd ....Item No 29)(a) Incommer MCCB 4 Pole 125 Amp 25 KA-01 Nos(b) Out going MCB DP 32 A 10 KA - 04 Nos (for light & fan DB to each quarter)(c) Out going MCB DP 63 A 10 KA - 08 Nos (for power and AC DBs to each quarter)(d) Out going MCB DP 10 A 10 KA - 01 Nos (for common area of block)(e) three phase, 4 wire, AC Static Direct connected, Smart Prepaid Energy Meters, BIS 16444 marked, current range 10-60 Amp, 3 x 240 V, accuracy class 1.0, UC1 category and above, along with in built load control switch, containing provision for TOD, with pluggable module based communication facility based on RF frequency 865-867 MHz radio frequency RF communication shall be with self heating Mesh Network as default communication system shall support as per existing system |
| 89 | Item No 30 : S & F modular MCB protected socket comprising of 24 A MCB 'C' curve, and 16/20 A socket for air circulation fan, modular switch 16 A complete with sheet metal enclosure for 230 Volts, 50 HZ AC including all accessories as one complete set all as specified and directed. |
| 90 | Item No 31: S & F electric kitchen chimneys heat auto clean with motion sensor auto of function, touch sensor control LED lighting, metal housing brushless DC motor, LPG leakage sensor, auto clean alarm, mode light, material tempered glass, noise level not less than 70 DB of size 90 CM and suction power 1500 m3/hr with suitable size of flexible aluminium pipe for chimmeys exhaust (upto 20 feet 4/6 inch) including all fixing arrangement complete 6 way silent filter less, 12 yrs warranty on motors (five year comprehensive), Autoclean alarm mode LT Please Enable Macros to View BoQ information Schedule 'A' Part-II (External Electric Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 91 | Item No 31: S & F electric kitchen chimneys heat auto clean with motion sensor auto of function, touch sensor control LED lighting, metal housing brushless DC motor, LPG leakage sensor, auto clean alarm, mode light, material tempered glass, noise level not less than 70 DB of size 90 CM and suction power 1500 m3/hr with suitable size of flexible aluminium pipe for chimmeys exhaust (upto 20 feet 4/6 inch) including all fixing arrangement complete 6 way silent filter less, 12 yrs warranty on motors (five year comprehensive), Autoclean alarm mode LT Please Enable Macros to View BoQ information Schedule 'A' Part-II (External Electric Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 92 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated earthed, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 95 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed.Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately. |
| 93 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed etc of the under mentioned type and sizes :- (a) 3.5 core x 120 sqmm RM 648.15 100.0 64815.0 (b) 3.5 core x 50 sqmm (Type V qtrs - 5 Block) RM 337.52 380.0 128257.6 (c ) 4 core x 10 sqmm (Street Light) Rm 174.68 420.0 73365.6 (d) 4 core x 6 sqmm (Garden lighting & Post top lantem) Rm 148.32 500.0 74160.0 |
| 94 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 95 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 96 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 97 | Supply and laying sand cushioning with dry and clean washed sand over and under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid. |
| 98 | Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 99 | Supplying and laying unreinforced precast concrete cable cover, class HV Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 100 | Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminium paints over a coat of red oxide primer, including painting white & red alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint and writing numbering of poles with black paint on yellow background complete all as specified and as directed.(Note: Excavation and earth work and PCC shall be measured and paid separately under respective items) |
| 101 | M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and directed. |
| 102 | Supply and lay tubing, ISI Marked conforming to IS 1239 Part-I 2004, ,light grade galvanised with all fittings specials such as bend, elbows,tees, short pieces connection, back nuts, diminishig pieces, caps, plugs and unions etc laid in trenches/ wall for cable passing etc and of following size complete all as specified and as directedNote: Excavation and earth work will be measure and paid seperately (a) 50 mm Dia RM 292.0 50.0 14600.0 (b) 80 mm Dia RM 511.1 10.0 5111.0 |
| 103 | M&L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate as in coping, filling, mass concrete and plasters, buttresses columns, posts etc complete all as specified & directed. |
| 104 | M&L for Precast Cement Concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations complete all as specified and directed. |
| 105 | M&L for 40 to 80mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed. |
| 106 | Supply, fixing and connecting single pole zinc oxide (gapless surge type) heavy duty station class, self supporting outdoor type lightning arrestor having rated voltage 11 KV (RMS) discharge current 10 KA suitable for rated system voltage of 12 KV supply system with maximum continuous operating Voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resister made of Zinc Oxide in hermetically sealed container complete with metal base, base inculcator and suitable terminals for ground connection and pressure relieving arrangement complete all as specified and as directed. |
| 107 | Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including dropout fuse set 09 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. |
| 108 | M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed. |
| 109 | Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI Pipe 50 mm dia complete all as specified and directed. |
| 110 | Supply and fixing HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed. |
| 111 | Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed. |
| 112 | Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed. |
| 113 | Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 114 | Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 115 | Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and as directed. |
| 116 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 117 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed . Total carried over to BOQ Rs. 2366746.3 148508500.0 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part III (External Water supply) Item Description of Item Unit Rate per Unit (Rs.) Qty Amount (Rs.) |
| 118 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 50 mm and all as directed. |
| 119 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 25 mm and all as directed. |
| 120 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 20 mm and all as directed. |
| 121 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 15 mm and all as directed. |
| 122 | Supply and fix Valves, Sluice, flanged of class 1.0 PN,80 mm dia and all as directed. |
| 123 | Supply and fix Valves, Sluice, flanged of class 1.0 PN,150 mm dia and all as directed. |
| 124 | S&F gun metal gate valve of following sizes screwed down high pressure with handle, Iron wheel (ISI marked) complete all as directed. (a) 50mm bore Each 979.08 6.0 5874.48 (b) 25mm bore Each 587.24 8.0 4697.92 (c ) 20mm bore Each 540.11 8.0 4320.88 |
| 125 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 126 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 127 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. Total carried over to BOQ Rs. 373079.28 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IV Special Item (Solar water Heater) Item Description of Item Unit Rate per unit (Rs.) Qty Amount (Rs.) |
| 128 | Supply and fixing Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore IS marked including all fitting arrangement such as elbow, bends, sockets, union etc required at site complete all as specified and directed. |
| 129 | Supply and fixing Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore IS marked including all fitting arrangement such as elbow , bends, sockets, union etc required at site complete all as specified and directed. |
| 130 | Supply and fixing 15 mm dia ,Bib taps,cast copper alloy with crutch or butterfly handle,screwed down ,screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 131 | Supply and fixing Rotational moulded polyethylene water storage tanks of capacity 500 Ltr (Cylindrical vertical with closed top) hoisted and fixed in positio all as specified and as directed. |
| 132 | Blank |
| 133 | Supply and fix, stop valves, cat copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 20 mm dia complete all as specified and directed. |
| 134 | M&L for 25 mm thick cement concrete (1:2:4) type B1 ,using 20 mm graded crushed stone aggregate laid over roof as in platforms for water tanks ,finished even and smooth without extra cement complete all as specified and directed. Total carried over to BOQ Rs. 576459.7 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part V (Road, Path Curvert ) Item Description of Item Unit Rate per unit (Rs.) Qty Amount (Rs.) |
| 135 | Excavating over areas, n exc 1.5 m deep and getting out soft/Hard Soil |
| 136 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil |
| 137 | Add to (or deduct from) last item for every 3 cm or part thereof above or below 15 cm average depth in soft /loose soil |
| 138 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 139 | M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 140 | M & L for Laying and compacting 150 mm thick (compacted thickness ) WMM laid in two layers of 75 mm each Wet Mix Macadam (WMM) grading as pe table 400-13 of MaRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with wate to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-1 OOKN static weight and consolidating to required gradien and camber complete all as specified and directed The finished surface tolerances to be as per Table 900-1 of MaRTH specifications for Road and Bridge works 2013 complete all as specified. |
| 141 | M&L premixed bituminous macadam laid/rolled and compacted to required gradient and camber with using 20 mm graded stone agg and paving bitumen 4% by the weight of total mix (consolidate thickness 75 mm or less as required ) complete all as specified and as directed. |
| 142 | Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate of application of 0. 7-1 kg/sqm on surface of WMM/WBM including preparation of WBM/WMM surfaces as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete including preparation of WBM/WMM surfaces all as specified and directed . |
| 143 | M & L for laying bituminous premix asphaltic semi dense concrete avaraging 40mm consolidated thickness with 5.5% binder content by weight of total mix using asphalt mechanical mixer plant & consolidated with 8to 10 ton power road roller to reqd level gradient camber and super elevation. |
| 144 | Continuous edging with roughly squared sand stones of size 30 mm thickness, length of each patti not less than 60 cm Complete of using sand stone/Katni sTone all as specified and directed. |
| 145 | M&L preparation of road surface and applying thermoplastic relflective paint in white or any tint marking of min 2 mm thick single coat as in center line and edge line road marking of 150/100 mm width using ''HOT MARK\\" thermoplastic modern propelled road marking machine as directed incl all ingredients such as blinder, glass beads, Titaniumdioxide calcium carabonate inter fillers thermroplastic requirement for glass beads shell be the Table No 650.4 of MOT specifications incl spraying of glass beads etc all as per manufactures instrustions and as directed |
| 146 | M&L for cement concrete type D-2 1:4:8 (using 40 mm graded aggregate) as in foundation filling and mass concrete , sub base complete all as directed. |
| 147 | M&L PCC 1:2:4 type B-0 (1:2:4) 12.5 mm graded aggregate as cills, steps, seismic and other similar brands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stone bed plates, etc including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 148 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 149 | Returning filling in including spreading levlling ,watering and well ramming in layers nexc 25cm thick complete all as specified and directed. |
| 150 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and directed. |
| 151 | M&L for 150mm thick(spread thickness) soling (or sub base) with broken boulder quarried stone interstices filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 10 tonne power roller complete all as specified and directed. |
| 152 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 153 | Material and labour for brick work with sub class B brick straight or curved on plain exc 6mtr mean radius built in CM 1:6 complete all as specified and directed. |
| 154 | M&L rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 155 | M & L reinforced concrete pipes 600mm bore, class NP2, laid and jointed with collars joints complete all as specified and directed. |
| 156 | M&L for preparation of new surfaces of wall and applying three coats of white wash complete all as specified and directed. |
| 157 | M&L for concrete bed for 600 mm dia pipe concrete bed type C2 1:3:6 using 40 mm graded aggregate to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in complete all as specified and as directed. |
| 158 | M&L reinforced concrete pipes 450 mm bore, class NP2, laid and jointed complete with collars joints complete all as specified and as directed. . |
| 159 | M&L for concrete bed for 450 mm dia pipe concrete bed type C2 1:3:6 using 40 mm graded aggregate to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in complete all as specified and as directed. |
| 160 | M&L reinforced concrete pipes 300mm bore, class NP2, laid and jointed complete with collars joints complete all as specified and as directed. |
| 161 | M&L for concrete bed for 300 mm dia pipe concrete bed type C2 1:3:6 using 40 mm graded aggregate to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in complete all as specified and as directed. Total carried over to BOQ Rs. 12753092.26 Signature of Contactor Date: Schedule 'A' Part VI (Sewage Disposal) Item Description of Item Unit Rate per unit (Rs.) Qty GRC Amount (Rs.) |
| 162 | Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed. |
| 163 | Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed |
| 164 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed. |
| 165 | Removal of excavated material (soil) to a distance exc 50 m n. exc 250 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 166 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 complete(Note: haunching dia shall be as per Item No 21 Of BOQ) |
| 167 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. |
| 168 | M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:4).complete all as specified and as directed. |
| 169 | M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as specified and as directed. . |
| 170 | M&L for 15 mm thick rendering in cement mortar (1:3) on brick / concrete/ stone surfaces mixed with water proofing compound as per manufacturer instruction , finished even and smooth using extra cement complete all as specified and as directed. |
| 171 | Supply only water proofing compound. |
| 172 | M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete |
| 173 | M&l for cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as in coping complete |
| 174 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 175 | S&F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed |
| 176 | S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders. |
| 177 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 178 | M&L for cement concrete type B2 , 1:2:4 using 40 mm gradded stone aggregate in surface channels and drains complete Total carried over to BOQ Rs. 905687.32 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VII (Security Fencing & Gate) Item Description of Item Unit Rate per unit (Rs.) Qty Amount (Rs.) |
| 179 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 180 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 181 | M&L for sub- class bricks with sub class B bricks straight or curved on plan exc. 6m mean radius and setting in cement mortar 1:6 etc. complete all as specified as directed. |
| 182 | M&L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 183 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 184 | M&L for type C2 1:3:6 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 185 | M&L for form works to sides of piller and posts complete all as specified and directed. |
| 186 | M&L RCC (Design Mix) M-25 ( using 20 mm graded aggregate ) Columns, pillars, piers, posts and strutscomplete all as specified and directed. |
| 187 | M&L RCC (Design Mix) M-25 ( using 20 mm graded aggregate ) Foundations, including rafts ,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed. |
| 188 | M&L for mild steel round bars 10mm dia and over cut to length bent to shape as reqd , incl crancking bending ,spirally for hooping columns hooking ends and binding with and including mild steel wire not less than 0.9 mm dia complete all as specified and directed. |
| 189 | M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape as reqd , incl crancking bending ,spirally for hooping columns hooking ends and binding with and including mild steel wire not less than 0.9 mm dia complete all as specified and directed. |
| 190 | M&L for mild steel TMT bars 5mm dia and over upto incl 10mm cut to length bent to shape as reqd ,as in stirrups and spacers complete all as specified and directed. |
| 191 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting,welding etc., and similar work conforming to Fe- 290 Gde E-165 |
| 192 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or wquare nut, n exc 5cm long complete all as specified and directed. |
| 193 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 194 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 195 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe- 290 (Gde E-165) complete all as specified and directed. |
| 196 | Preparation of two coats of synthetic enamel paint on new steel surfaces of any description, over 10cm in width or girth,not otherwise described including preparation over a coat of red oxide Zinc chrome prime complete all as specified and directedr complete all as specified and directed. |
| 197 | Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and directed. |
| 198 | Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 2388595.29 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VIII (Area Drainage) Item Description of Item Unit Rate per unit (Rs.) Qty Amount (Rs.) |
| 199 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil complete all as specified and directed. |
| 200 | M&L hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to a true surface of broken stone or boulders complete all as specified and directed. |
| 201 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 202 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 203 | M&L for Brickwork with sewer bricks straight or curved on plan exc 6m mean radius for man-holes/septictank/ soakwell etc.in sewer works |
| 204 | M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 205 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, bed plates, seismic and other similar bands, plinth bends, etc including weathering slightly rounded or chamfered angles and throuting, inclusing necessary form work etc complete all as specified and directed |
| 206 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 207 | Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 208 | M & L for PCC (1:3:6) type C-2 using 20mm graded crushed stone aggregate cement concrete in surface channels and drains complete all as specified and directed. |
| 209 | Extra for forming fair finished drain or channel 40 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed. |
| 210 | Returning filling in including spreading levlling ,atering and well ramming in layers nexc 25cm thick complete all as specified and directed. |
| 211 | Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 5485288.32 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part IX (Site Clearance) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 212 | Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft soil. |
| 213 | Excavating over areas, n exc 1.5 m deep and getting out soft/Hard Soil |
| 214 | Earth filling (for site development) incl raising (or lowering) not exc 1.5 m high earth spreading in layers n.exc 30 cm thick watering and rolling and finishing to reqd size and shape etc |
| 215 | Removing excavated material to as distance exc 250m but n exc 500 mtr and deposited where directed. |
| 216 | Return filling in including spreading levelling, watering and well ramming in layers nexe 25 cm thick complete all specified and directed. Total carried over to BOQ Rs. 1542349.7 SIGNATURE OF CONTRACTOR DY Dir (Contracts) DATED _________ FOR ACCEPTING OFFICER Schedule 'A' Part X (Internal Electric Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 217 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories ncluding PVC insulated multistrandard copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- (a) One light point controlled by one, one way switch 5 Amps Point 992.75 643.0 638338.25 (b) One fan point/exhaust fan/wall fan point controlled by one, one way switch 5 Amps and regulator Point 992.75 209.0 207484.75 (c) One light point controlled by , two way switch 5 Amps Point 1397.96 10.0 13979.6 (d) One bell point controlled by one, bell switch 5 Amps Point 992.75 38.0 37724.5 (e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. Point 284.1 76.0 21591.6 (f) M & L for Point wiring using approved colour coding as per IS, with multistranded copper condu+B5:B11 Point 1070.4 152.0 162700.8 |
| 218 | Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multi strandard FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 219 | Description all as per item No 1 here in before but using 4 sq mm single core copper conductor two nos FRLSH cable of multi standard PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 4 sq mm PVC insulated copper conductor FRLSh cable as earth continuity conductor along with wiring and connecting to the common eath dolly. Note :- (a) Circuit wire from MCB to switch board is deemed to be included with unit rate of item point wiring and the size of circuit wire should be 4.0 sqmm for L.N.E |
| 220 | S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete. |
| 221 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 222 | S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified. |
| 223 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 224 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 225 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 226 | S & F Bell push modular 6 Amps single module complete all as specified. |
| 227 | S & F Bell Electric ding dong type suitable for operation on 230 volt 50 HZ AC supply complete all as specified and as directed. |
| 228 | S & F for sheet metal enclosure with socket plug top and MCBs 20 Amps 240 V single pole and neutral enclosure with a two pin and earth plug and socket complete with necessary provision for inserting the metal enclosure box in wall by cutting the brick/stone masonry etc and making good of disturbed surface to match with existing color of wall complete all as specified and as directed. |
| 229 | M & L for sub main wiring with approved color coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory color and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note :- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit. |
| 230 | M & L for Sub main wiring with approved color coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6.0 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory color and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable and one run of PVC conduit will be measured as one unit |
| 231 | S & F for sheet metal enclosure MCB DB SPN 16 way with suitable current rated bus bar 240 volts double door including blanking plate for dummy space with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. Note :- The rate of dummy plate shall be deemed to be included in unit rate of item |
| 232 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. |
| 233 | S & F for Tripper RCBO (EL+MCB) of rating 32 Amps, DP 10 KA, C curve, 4 M, 100 mA (nearest standard size) 240 volts, protection against over currents, short circuit and earth leakage faults As per IS 12640-2 & IEC 61009 1 complete ass as specified and as directed by Engineer-in-Charge |
| 234 | S & F for Tripper RCBO (EL+MCB) of rating 25 Amps, DP 10 KA, C curve, 4 M, 100 mA (nearest standard size) 240 volts, protection against over currents, short circuit and earth leakage faults As per IS 12640-2 & IEC 61009 1 complete ass as specified and as directed by Engineer-in-Charge |
| 235 | S & F for MCB single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 236 | S & F ceiling fans complete with blades, down rods, electronic regulator modular type and accessories, 230 V, 1200 mm sweep. Minimum air delivery 210 CFM with service value 6.0 BEE. 5 star rated with brushless direct current motor (BLDC) cmplete all as specified and directed. |
| 237 | S & F for energy efficient exhaust fan of 300 mm sweep 1350 RPM, 3 metallic blade, flow rate not less than 510 CuM per Hour made of metal body complete with louver with bolts nuts and washers, bolt , embedded in the wall including provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. |
| 238 | S & F for wall mounted LED tube light fitting 1 x 10 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, luminous efficacy not less than 120 lumen/watt, CRI > 80%, THD < 30%, driver efficiency > 85%, PF > 0.9 Correlated color temperature 6500 K (cool daylight) 170 Volts to 230 volts and LED chip, Driver and Housing should of same make with warranty option of 2 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 239 | S & F for wall mounted LED tube light fitting 1 x 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting ,luminous efficacy not less than 120 lumen/watt, CRI > 80%, THD < 30%, driver efficiency > 85%, PF > 0.9 Correlated color temperature 6500 K (cool daylight) 170 Volts to 230 volts and LED chip, Driver and Housing should of same make with warranty option of 2 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranderd copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 240 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts (or nearest standard size), luminous efficacy not less than 110 lumen/watt, LED Chip, Diver and Housing should be same make with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper condutor cable multi stranded from ceiling rose to light fittinig including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer-in-charge. |
| 241 | Suppy, installation, commissioning and testing of electric water heater (geyser) of capacity 25 ltrs vertical storage anti corrosive body 5 star rating, Wattage : 2000 W : Capacity : 25L ; Star rating 5 ; Pressure 8 bar 3 Level safety : Capillary thermostat, automatic cut-out & mulit-functional valve to provide higher safety anti-rust : fitted with specially designed magnesium anode which prevents corrosion due to hard water quality, inner tank made of MS glass line coating with anti corrosion with safety valve, thermostat, NRV, Heavy stainless steel connection pipe for geyser connection pipe - 02 Nos for hot and cold water, necessary gate valve of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 242 | M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of GI wire up to 7.5 mtr connected to earthing point complete all as specified and as directed. Total carried over to BOQ Rs. 4356035.41 SIGNATURE OF CONTRACTOR DY Dir (Contracts) DATED _________ FOR ACCEPTING OFFICER Schedule 'A' Part XI (Internal Water Supply) Item Description of Item Unit Rate per unit(Rs.) Qty Amount (Rs.) |
| 243 | S&F 15 MM bore galvanized steel tubing, medium grade galvanized with all fittings ,fixed to walls and cellings or laid in floors incl cutting chasing and making good complete all as specified and directed. |
| 244 | S&F 20 MM bore galvanized steel tubing, medium grade galvanized with all fittings , fixed to walls and cellings or laid in floors complete all as specified and directed. |
| 245 | S&F 25 MM bore galvanized steel tubing, medium grade galvanized with all fittings , fixed to walls and cellings or laid in floors complete all as specified and directed. |
| 246 | S&F 50 MM bore galvanized steel tubing, medium grade galvanized with all fittings , fixed to walls and cellings or laid in floors complete all as specified and directed. |
| 247 | S&F 20 MM bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let /inlet pipe or union including threading to existing pipes on both ends complete all as specified and directed by engineer in charge. |
| 248 | S&F 25 MM bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let /inlet pipe or union including threading to existing pipes on both ends complete all as specified and directed by engineer in charge. |
| 249 | S&F 50 MM bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let /inlet pipe or union including threading to existing pipes on both ends complete all as specified and directed by engineer in charge. |
| 250 | S&F 15 MM dia pillar taps, cast copper alloy with capstan head chromium plated , screwed down high pressure with or without lettered ‘Hot or Cold’ with long screwed shanks and fly nuts , screwed for iron pipe, complete all as specified and directed |
| 251 | S & F for long body Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed, 15 mm, fancy type, chromium plated fixed complete. |
| 252 | S & F for Angle cock/ Stop valves, cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed15mm fixed complete. |
| 253 | S & F PVC connections 15 mm size with brass nuts both side of length 450 mm complete all as specified and directed. |
| 254 | S&F in brass chromium plated wall mixer (2/3 hole) for mixing hot & cold water arrangement, long shank suitable 15mm bore pipe of approved quality screed down for iron pipe and fixed. |
| 255 | S&F chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by Engr-in-charge |
| 256 | S&F brass chromium plated overhead shower 125 mm size (Square/rectangular) with or without swivel joints including fixing to steel pipe of 15 mm bore complete all as specified and directed |
| 257 | S&F Vitreous China urinals half stall white(minimum), with grating and union for discharge pipe(exclusing flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engr-in-charge |
| 258 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engr-in-charge Total carried over to BOQ Rs. 758081.35 SIGNATURE OF CONTRACTOR DY Dir (Contracts) DATED _________ FOR ACCEPTING OFFICER |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail