| 1 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within IICT campus as directed by Engineer incharge. |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground outside IICT campus to the approved GHMC ground as directed by Engineer incharge. |
| 3 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 4 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre Asain make |
| 5 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Birla wall care putty Asain make |
| 6 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats Asain make |
| 7 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 8 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 9 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) Modi guard make or equivalent approved make. |
| 10 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) Modi guard make or equivalent approved make. |
| 11 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness |
| 12 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 13 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm |
| 14 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm bitumen 85/20 to be applied 0.5 kg/sqmby the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete.cost including providing & applying silver sheild paint on top of the sheet refelctive two coats. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3mm thick |
| 15 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work Asain make |
| 17 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface Apex asain make |
| 18 | Exposing the corroded steel around its full circumference and cleaning the same to remove all loose scales and corrosion deposits by hard brush with emery paper or, by any suitable mechanical means as directed by Engineer-in-Charge, so as to get bright conditions and removing the corrosion deposits from pits and imperfections within its surface by compressed air and water at a high pressure and providing and applying one full coat of anti corrosive treatment of epoxy 'A' (Nitozinc primer/ Zinc rich primer of FOSROC Product) or any other equivalent approved compound over the cleaned and prepared surface as per manufacturers specifications. |
| 19 | Providing and spraying bond coat Nito Bond-SBR of FOSROC Product ) for the entire surface to receive the coat prior to application of cement plaster. |
| 20 | Providing and applying a bond coat of Nitobond-EP of FOSROC product to the exposed surfaces of all structural members as per the manufacuturers specifications at all levels as directed by Engineer-in-Charge. |
| 21 | Providing and laying S.S.Railing of 304 grade steel pipe of 50mm dia hard rail with 40mm dia vertical support pipe every 1m centre to centre and horizontal 20mm dia pipe 1.5mm thickness of the pipe etc. complete as directed by engineer in charge. |
| 22 | Removing of existing water proofing damaged sheet and cleaning complete etc., and shifting outside IICT to the approved GHMC dumping grounds as directed by the Engineer incharge. |
| 23 | Providing and fixing M.S. Weld mesh of 50mm x 50mm openings of 12 gauge thick including cutting, bending, and fixing etc., complete as directed by Engineer-in-Charge. |
| 24 | Providing and fixing 125mm long shear connectors (bent to L-shape) of 12 mm diameter steel bars of TATA /Vizag Steel/ SAIL of approoved make with epoxy 'B' ( Lockset / Locfix of FOSROC Product ) or, equivalent by drilling holes of suitable depths and diameter in structural members with high speed drilling machine as directed by Engineer-in-Charge. The rate shall be inclusive of necessary tools and equipment etc., complete. as directed by Engineer-In Charge. |
| 25 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ Metal angular frames/ recessed steel/ PVC conduit as required.Make: Finolex/ Havells |
| 26 | 3 x 2.5 sq.mm |
| 27 | 3 x 4 sq.mm |
| 28 | 5 x 4 sq. mm |
| 29 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular indicator switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(i) Group C |
| 30 | S/F PVC Conduit: Supplying and fixing of following sizes of PVC conduit along with accessories on surface/recess cutting the wall and making good the same in case of recessed conduit as required.Make: Sudhakar25mm |
| 31 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.Make: Anchor/ Legrand/ North West12 Module (200mmX150mm) |
| 32 | S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required. |
| 33 | 5/6 A switch |
| 34 | 15/16 A switch |
| 35 | 3 pin 5/6 A socket outlet |
| 36 | 6 pin 15/16 A socket outlet |
| 37 | S/F 'C' series MCB: Supplying and fixing of 5A to 32A rating, 240V/415 V, 10 kA, 'C' curve. Miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc., as required. |
| 38 | Single pole |
| 39 | Triple pole |
| 40 | Triple pole & Neutral |
| 41 | Labelling and Lettering of Switchboard/ Power board of required font to suit the equipment with required coloured paint with elegant finishing as required by the Engineer. |
| 42 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 43 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 44 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 Hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)36 wattMake: Philips |
| 45 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 46 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 47 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 48 | Supply of poly carbonate 1x18 watts, 4feet, LED Tube light set, along with 1xTLED fixture, LED Tube-1no, complete with all accessories as directed by Incharge Electrical.Cat.no.TMC501P 1xTLED 20W-14# LED tube 18watts, 865, T8Make:Philips |
| 49 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 50 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Make: Philips/ Havells |
| 51 | 50 watt |
| 52 | 70 watt |
| 53 | Supply and laying of XLPE insulated, PVC sheathed, 1100 V grade, FRLS ISI marked, Armoured Copper conductor, cable of following size on Wall surface/ in Ground/ in existing PVC conduit/ as required and as directed by Enigineer-In-Charge.3Cx1.5 Sq.mm |
| 54 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door |
| 55 | Disconnecting and removing of old DB/ Light fittings and Ceiling fans: Disconnecting and removing of existing Tubelight fittings/ Ceiling Fans/ wall mount fans/ Recessed LED Light fittings and Existing Switch boards, MCB Enclosure boxes, Old DB of all types including existing wiring and transporting all the dismantled materials with out any damage from the site to departmental stores/ debries yard as directed by the Engineer in charge. |
| 56 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required and as directed by Engineer-In-Charge.3 X 1.5 sq. mm (19mm) |
| 57 | Dismantling, Reassembling, testing and commissioning of Existing 5 feet fume hood with blower & Ducting including carrying/transfer of dismantled materials to another lab within 100mtrs. |
| 58 | Dismantling and Reassembling of Lab work benches (\\"U & L\\" shape configuration) complete with C-Frame, Storage modules, Granites, Electrical Trunking and Utility lines etc. |
| 59 | Supply of Cat-6 UTP cable box 305mtr. |
| 60 | Supply of Cat 6 Information outlet with face plate and back box |
| 61 | Supply of 2 inch pvc conduit. |
| 62 | Supply of 1 inch pvc conduit. |
| 63 | Service charges for laying of Cat 6 UTP cable through pvc conduit. Fixing of face plate, termination of Information outlet, fixing of switch, end to end testing. Please Enable Macros to View BoQ information |