| Sl. No. | Item Description |
| 1 | Civil works |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 3 | Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, Note:-Excavation of hard rock shall be the property of the contractor subject to recovery. excavated material has to shift from site within 15 days after instruction issued by Engineer-In Charge otherwise after this penalty will imposed on contractor at the rate of Rs 50 per cum per day. Ordinary rock |
| 4 | Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out theexcavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (No extra lift is payable if work is done by mechanical means) in all kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 5 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Supplying and filling in plinth under floors including watering ramming consolidating in layers not exceeding 20cm in depth and dressing complete. With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm). |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 40mm nominal size graded stone aggregate. M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete |
| 9 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 10 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, Having 50 kg cm2 average compressive strength Cement mortar 1:6 (1 cement : 6 sand) |
| 11 | Pre construction antitermite treatment to the building under construction by providing. Stage 1: Treating the bottom and the sides (upto 30 cm height of the excavated trench @ 5 liters per sqm of the surface area. Stage 2: After masonry/RCC work, the backfill in the immediate contact with the foundation structure treatment @ 7.5 liters per sqm. Of the vertical surface of the substructure for each side. Stage 3: surface treatment by spreading emulsion over the plinth area before laying the base concrete under floors @ 5.0 litres/Sqm. Stage 4: Pumping the emulsion in plinth masonry on filling side at floor junction @ 7.5 litres/Sqm. Stage 5: Pumping the emulsion from outer side of the plinth below ground around the masonry @ 5.0 litres/Sqm as per I.S. 8944 Emulsion. (1Chlorpyrifos: 19 water) with five years service guarantee (Measurements to be taken for plinth area) Note – Treatment should start when foundation trenches and pits are ready to take bed concrete or leveling course in foundations. Lying of bed concrete should start when the chemical emulsion has been absorbed by the soil and the surface is reasonably dry. Treatment should not be carried out when it is raining or when soil is wet with rain or subsoil water. This also applies to fill up soil within the plinth area before laying the subgrade for flooring. |
| 12 | Making plinth protection 50mm thick of cement concrete grade M10 over 75mm bed of dry metal ballast 40mm nominal size well rammed and consolidated and filled with sand including finishing the top smooth (with 20mm nominalsize graded stone aggregate.) |
| 13 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and upto floor two level excluding cost of centering, shuttering, finishing and reinforcement: M-20 Grade Concrete |
| 14 | Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate)in beams, suspended floors, roofs havingslope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstaircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement inconcrete grade. M-20 Grade Concrete |
| 15 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 |
| 16 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Columns, Pillars , Piers, Abutments, Posts and Struts. |
| 17 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Above plinth upto 3.6 m height from plinth level |
| 18 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 19 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers |
| 20 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Stairs, (excluding landings) except spiral-Staircases. |
| 21 | Brick work with fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, in super structure above plinth level up to floor two level in : Having 75 kg / cm2 average compressive strength. Cement mortar 1:6 (1 cement : 6 sand) |
| 22 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 16mm dia M.S. bar bent to shape as per standard drawing. |
| 23 | Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished machine cut Granite of approved shade, colour and texture of Granite Door frame. in cement mortar 1:3 (1 cement :3 sand) including pointing with an admixture of pigment to match the shade including fixing of granite stone door frame with epoxy resin based adhesive including secured to the backing by means of cramps, drilling of hole with rawl plugs and screws 75mm long cleaning etc. complete. Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, tower bolt etc complete at all levels as per instruction of Engineer-in-Charge. Granite Door frame for 200mm thick wall Thickness. |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutter. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 25 | Providing and fixing factory made integral PVC flush door shutter made from rigid PVC foam sheet (Single Extruded) with density not less than 600 kg/cum, conforming to IS: 2380 part 14 for screw holding strength with Celluka finish surfaces on both sides at the manufacturing process itself, manufactured by an ISO : 9001 - 2000 certified company. 28 to 30 mm thick plain solid PVC flush door shutter |
| 26 | Providing and fixing bright finished brass handles with necessary screws etc. complete. : 125 mm |
| 27 | Providing and fixing bright finished brass sliding door bolts with nuts and screws etc complete.: 300x16mm |
| 28 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : : 250x10 mm |
| 29 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 30 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. |
| 31 | Providing and fixing stainless steel (Grade 304) railing made of Hollowtubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in-charge. (For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 32 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 33 | 12 mm cement plaster of mix : 1:6 (1 cement : 6 sand) |
| 34 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement : 6 sand) |
| 35 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 36 | Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washersetc. complete Hot finished welded type tubes |
| 37 | Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00mm thick with zinc coating not less than 275gm/m² |
| 38 | Providing and laying Ceramic glazed floor tiles 300x300 mm or more (having thickness 6 to 7mm) of 1st quality conforming to IS : 15622 of approved make in any colours and shade laid on20 mm thick Cement Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 39 | Providing and laying Antiskid floor tiles of any sizes, 12 mm thickness with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement with matching pigments etc., complete. |
| 40 | Providing and fixing Ceramic glazed wall tiles 300x450 mm or more (having thickness 6 to 7 mm) of 1st quality conforming to IS: 15622 of approved make in all Colours& shades, except burgundy, bottle green, black laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement: 3 sand)preprad same day when mortar is still green jointed with grey cement slurry @3.3 kg per sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 41 | Providing and laying Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing and as directed by the Engineer-in-Charge Granite stone slab Dark Black. Dark Red, White or equivalent, Flamed Finish Granite |
| 42 | Granite stone work 18mm thick of any colour in riser of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 (1 cement:3 sand) and jointed with white cement slurry mixed with pigment to match the shade of slab. |
| 43 | Providing edge moulding to 18mm thick marble stone counters, Vanities, window sills etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. |
| 44 | Providing and laying digital print random design (PGVT)/ (GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality/ premium quality including grouting the joints with white cement and matching pigments etc. complete For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) Size 600X600 mm thickness 9-10 mm |
| 45 | Providing and laying digital print random design (PGVT)/ (GVT) vitrified tiles in different sizes with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours& shades, 1st quality / premium in skirting, riser, dado and wall lining laid our 12mm thick cement mortar 113 including grouting the joints with white cement and matching pigments etc. complete For skirting, riser, dado and wall lining etc. glossy/ rustic /stain/matt finished in all colours and shades Size 600X600 mm thickness 9-10 mm |
| 46 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 47 | Providing and fixing glass strips 40 mm wide and 4 mm thick in joints of terrazo/ cement concrete floors. |
| 48 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 49 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete. Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. |
| 50 | Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 51 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For Fixed Portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 52 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 53 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5 mm thickness |
| 54 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-Charge (Door handle, lock and stopper etc.to be paid separately). |
| 55 | Providing and fixing 12 mm thick toughened glass partition with patch fitting All work complete as per directed by the Architect/Engineer-in-Charge. |
| 56 | Providing and fixing white vitreous china Anti germ Fluoro-Polymer Coated Water closet squatting pan with 100 mm sand cast Iron P and S- trap, and 7.2 liter Low level, dual flush, PP (Poly Propylene) made open slim wall hung cistern capacity 3 liter/6 liter flushing, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) |
| 57 | Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal back inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) Size 385X325X635 mm with Concealed sensotronic flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : URS-WHT-13253N & PRS-CHR-073 |
| 58 | Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with chrome plating. |
| 59 | Providing and fixing white vitreous china pedestal type Anti germ Fluoro-Polymer Coated Water Closet with soft closing seat cover, and 7.2 litre Low level slim dual flushing, PP (Poly Propeline) made 80 mm thick concealed flushing cistern, flushing capacity 3 litre/6 litre, with all fittings and fixtures complete including cutting and making good the wall and floors wherever required. Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan Size 360X545X395 mm with solid poly propelyne made soft closing seat cover (Premium Range) |
| 60 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 61 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mm. |
| 62 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 63 | Providing and fixing bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 64 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia nominal bore |
| 65 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia nominal bore |
| 66 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia. nominal bore |
| 67 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 32 mm dia. nominal bore |
| 68 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. External work : including trenching and refilling etc. 50 mm dia. nominal bore |
| 69 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS: 8931, 15 mm nominal bore. |
| 70 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore. |
| 71 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore |
| 72 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 32 mm nominal bore. |
| 73 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 50 mm nominal bore |
| 74 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15mm nominal bore |
| 75 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 76 | Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet |
| 77 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete : Excavation to be paid seperataly. 150mm dia |
| 78 | Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design 150mm dia |
| 79 | Providing and laying below ground unplasticised PVC pipe to with stand working pressure of 4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings etc. complete. Excavation tobe paid seperataly. 110 mm diameter OD |
| 80 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diameter (minimum wall thickness 1.8mm) |
| 81 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.50 75 mm bend (minimum wall thickness 1.8mm) |
| 82 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.50 110 mm bend (minimum wall thickness 2.2mm) |
| 83 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm she (minimum wall thickness 2.2 mm) |
| 84 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm (minimum wall thickness 1.8mm) |
| 85 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 86 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 75x75x75 mm (minimum wall thickness 1.8mm) |
| 87 | Providing and fixing on wall face Unplasticised - UPVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm (minimum wall thickness 2.2mm) |
| 88 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm (minimum wall thickness 1.8mm) |
| 89 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm (minimum wall thickness 2.2mm) |
| 90 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15mm nominal bore |
| 91 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stoneaggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With well burnt bricks |
| 92 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc. of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658- 2006 made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver blocks as per required sizeand pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications and direction of Engineer-in-Charge. 60 mm thick C.C. paver block of M-35 grade |
| 93 | Water proofing treatment over Roof, Wall, Chajjas,, Balcony with fibre glass mesh and Sealer coat at leakage/ seepage area consisting of (i) Surface preparation roughening of surface, opening cracks in ‘V’ groove in size of 5mmX10mm (WXD), filling of cracks with putty with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii) Providing and applying 1st coat of fibre glass mesh (minimum thicknes 70-80 micron) and two component flexible waterproof and protective modified mortar, dry powder 80% chemical 20% acrylic resin having 30% solid contents) with mix proportion of part 1 and 2 with proper mixing with laying of fiber glass mesh (of weaving size of 10X10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to air cure for minimum 2 Hrs. After two hours of 1st coat applying 2nd coat (minimum thickness 100 micron) of fibre glass mesh of with mix proporation of part 1 and 2 with proper mixing. Allow the coating to air cure for minimum 2 hrs. Consumption of two component should be acrylic resin @17.90 kg for 10 sqm area or as per manufacture instructions. (After two coats of diamond shield, surface is to be cured properly minimum for 4 hrs. before application of third coat). (iii) Providing and applying 1st coat of sealer coat 50-60 micron (single component Hight build elastomeric, fixable pure acrylic waterproofing membrane having solid content of 65%) and allow it to air cure for 4Hrs. minimum. After two hours minimum of 1st coat applying 2nd and finals coat 120-140 micron of sealer coat and allow it to air cure for 4 Hrs mimimum. Consumption of Sealer coat should be @ 5.40 kg per 10 sqm area. (iv) The treated area should be cure with water for 48 hrs. by flooding the surface. (v) The final appearance of the coating will be milky white. All above operations to be done in order.(five years guarantee) |
| 94 | Finishing walls by any mechanical or manual means with Premium Acrylic Smooth exterior paint (Premium exterior) of required shade including all scaffolding. New work (Two or more coat applied @1.67ltr/10sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10sqm with crack bridging ability of upto 0.5 mm on horizontal surfaces with an elongation of 150% and water proofing of upto 3 bars on vertical surface) |
| 95 | Providing and fixing in position best Indian (bonut size 24mm, ceramic disc size 19mm and min. nickel plating 0.10 micron and chrome plating 0.3 micron, quarter turn) Wall Mixer with 115mm bend. (Premium Range) |
| 96 | Providing and fixing in position best Indian shower rose 150mm dia, body and face chrome plated, brass made body, Silicon based Rubbit cleaning nozzles.(Premium Range) |
| 97 | Electrical Works |
| 98 | Concealed PVC conduit HMS: Supply and fixing PVC conduits required confirming to IS 9537 (Part-3), ISI marked along with the accessories in concealed system etc. as requiredPVC. conduit 25 mm (HMS) |
| 99 | Concealed PVC conduit HMS: Supply and fixing PVC conduits required confirming to IS 9537 (Part-3), ISI marked along with the accessories in concealed system etc. as requiredPVC. conduit 32 mm (HMS) |
| 100 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-1 or 2 Module metal box |
| 101 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-4 Module metal box |
| 102 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-6 Module metal box |
| 103 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-8/9 Module metal box |
| 104 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-12 Module metal box |
| 105 | Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-18 Module metal box |
| 106 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as perspecification for :-Light point/fan points. Using modular accessoriesPrimary short point |
| 107 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as perspecification for :-Light point/fan points. Using modular accessoriesPrimary medium point |
| 108 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as perspecification for :-Light point/fan points. Using modular accessoriesPrimary long point |
| 109 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints etc. as required as perspecification for :-Twin control light points. Using modular accessoriesMedium point |
| 110 | Supplying and drawing single core PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.2.5 sq. mm. wire3 X 2.5 sq. mm. |
| 111 | Supplying and drawing single core PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.2.5 sq. mm. wire6 X 2.5 sq. mm. |
| 112 | Supplying and drawing single core PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.4.00 sq. mm. wire3 X 4.00 sq. mm. |
| 113 | Supplying and drawing single core PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.4.00 sq. mm. wire6 X 4.00 sq. mm. |
| 114 | Supplying and drawing single core PVC insulated cable FR-LSH with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.10.00 sq. mm.5 X 10.00 sq. mm. |
| 115 | Supplying of approved make, powder coated metal double door vertical TPN MCB DB IP 43 protection with provision for MCCB upto 160A TP/FP 36kA as incomer and space for SP/TP MCBs as outgoing (without MCCB/MCBs) inclusive of busbar &connections etc8 Way without MCCB |
| 116 | Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator):8 Way (8+24) |
| 117 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-Tripole pole - MCB TP 50Amp to 63Amp 10kA rating |
| 118 | Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard conforming to IEC:61009-1 & IS:12640-2, 240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approvedmanner as per specification.4 pole 40Amp, 30mA sensitivity |
| 119 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'C' series with short circuit indication, suitablefor 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-Single pole - MCB SP 6Amp to 32Amp 10kA rating |
| 120 | Labour charges for fixing sheet steel enclosures, MCB/MCCBDB flush mounting type, as per accepted practice, duly embeddedand end plate completely flushed in wall, cable connection etc. complete :-for item no. 115 |
| 121 | Labour charges for fixing sheet steel enclosures, MCB/MCCBDB flush mounting type, as per accepted practice, duly embeddedand end plate completely flushed in wall, cable connection etc. complete :-for item no. 116 |
| 122 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)MCB/Isolator SP/DP |
| 123 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)MCB/MCCB/ Isolator TP/TPN/FP |
| 124 | Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete.6/10Amp SP 250 Volt modular switch |
| 125 | Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete.16/20Amp SP 250 Volt modular switch |
| 126 | Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete.Blank plate 1 module |
| 127 | Supply and fixing as per specification socket outlet of approved make & ISI marked with necessary material complete10Amp 250 Volt 3 Pin modular type |
| 128 | Supply and fixing as per specification socket outlet of approved make & ISI marked with necessary material complete10/16/20Amp 250 Volt 3 Pin modular type |
| 129 | Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen outputshould be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser. |
| 130 | LED down lighter (surface mounting) Supply and fixing surface mounting LED down lighter, LED of 1 to 3Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.14/15 Watt, color temp 3000-6500k as required. |
| 131 | LED light (surface mounting) : Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver, PF> 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.LED luminiare 2' X 2', 36Watt, color temp 3000-6500k as required. |
| 132 | Bollard : Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 8-10W cylindrical shape : Bollard LED 8-10 Watt cylindrical shape height > 700mm, color temp 3000-6000k |
| 133 | Street light with high power LED system : Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job.60Watt, color temp 3000-6500k as required. |
| 134 | Fixing of street light fitting : Fixing of street light bracket of required angular shape and size pipe bracket on wall/pole including M.S. clamp not less than 40X5mm flat, nut, bolt 12mm of required length with necessary material including connection 3 core flexible wire etc. complete as required excluding cost of pipe paid separately. |
| 135 | 19/20mm dia. M.S. pipe 1 meter in length for lights : Supplying and fixing of 19mm/20mm dia. M.S. pipe 1 meter in length for CFL/LED street light/bulkhead/water tight bracket including bending to shape and wiring with 1.5sqmm W.P./PVC wire etc. as required. |
| 136 | Supplying, Installation, Testing and Commissioning of underwater Luminaries surface mounted RGB LED spot light 6 x 3W with IP 68 protection, SS/ aluminum dia casting body with power coated paint, soft rubber gasket along with 2 years free replacement guaranty etc. complete as required. |
| 137 | Supplying, Installation, Testing and Commissioning of water proof (IP 68) power supply unit of not less than 200W i/c connection along with 2 years free replacement guaranty etc. complete as required. |
| 138 | Supplying, Installation, Testing and Commissioning of fixing of Power Supply/SMPS for suitable to run LED Lights, Body-Metal input Power-220 V AC/ Output Power-12 V DC etc. complete as required. |
| 139 | Submersible flat cable 3 core cu. Wire : Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.2.5 sq.mm multi strand |
| 140 | Analog time switch for automatic ON - OFF street light : Supplying and fixing of analog time switch for automatic ON-OFF street light of approved make in existing LT panel including connections etc. as required as per specification |
| 141 | Supplying and fixing of contractor 2 Pole rating 240/415V :for ON - OFF street light of approved make in existing LT panel including connections etc. as required as per specification40A |
| 142 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS : 374/2019 with upto date amendments.Ceiling Fan Ornamental 1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE. |
| 143 | Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board.100 Watt (2 module) |
| 144 | Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt /anchor hole fastener etc. complete finished and as required.400 mm sweep |
| 145 | Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required.300mm sweep RPM 900 /1400 |
| 146 | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required |
| 147 | Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation in hard rock and refilling the pit with black soil. |
| 148 | Providing and fixing 25mm X 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required |
| 149 | Supply and laying 25mm X 5mm G.I. strip at 0.5 metre below ground level as strip earth electrode including jointing etc. as required. |
| 150 | Providing and fixing 25mm X 5mm G.I. strip on surface or in recessed for connection etc. as required |
| 151 | MCCB 3Ph & N, 4Pole, 50Hz, 415V (thermal - magneticrelease) - Supplying of ISI marked and approved make of mouldedcase circuit breaker (MCCB) suitable for 3 phase & N, 4pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal-magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2MCCB 160A, 25kA, 4P : MCCB 25kA current rating - 160Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 4 Pole |
| 152 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor3½ core armoured - 70 sq. mm |
| 153 | Laying of one number armoured / unarmoured power cable 1.1.KV grade of size exceeding 25sq. mm but not exceeding 120 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required. |
| 154 | Laying, 1.1KV grade of size exceeding 25sq. mm but not xceeding 120 sq. mm : Laying of one number armoured/unarmoured power cable 1.1KV grade of size exceeding 25sq. mm but not exceeding 120 sq. mm in the existing masonry open duct as required. |
| 155 | Crimping type alum. Lugs : Supplying and fixing crimping type alum. lugs as per I.S.S. specification suitable for following size of cable with alu./copper solid/stranded conductor evenly crimped with high/pressure tool and connected toswitch gear/bus/M.C.C.B./M.C.B. etc. as required complete.For conductor size : 70 Sq mm |
| 156 | Surface PVC conduit MMS : Supplying and fixing PVC conduit as required confirming to IS 9537 (Part-3), ISI marked along with accessories on surface etc. as required.PVC conduit 25 mm. (MMS) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail