| Sl. No. | Item Description |
| 1 | Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared). |
| 2 | Surface Dressing of the ground inany kind of soil including removing vegetation inequalities not exceeding 15cm depth and disposal of the rubbish within a lead upto 75m as directed. |
| 3 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed.The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of the excavation not exceeding 1500mm. |
| 4 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 5 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.In ground floor including roof. upto 150 mm. thick. |
| 6 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish, as directed within a lead of 75 m. including stacking of steel bars. In ground floor including roof. |
| 7 | Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm Including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). (a) With earth obtained from excavation of foundation. |
| 8 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water ramming complete including the cost of supplyof sand. (payment to bemade onmeasurement of finished quantity). |
| 9 | R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cement finishing and cutting chase fitting and fixing in position, mending good damages as necessary complete. 50 mm. Thick panels. In ground floor. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL |
| 10 | Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed. (Payment to be made on measurement of portion of roof or wall removed). |
| 11 | Fitting and fixing old pieces of asbestos, G.C.I. or C.I. sheets or plain sheets including closing old holes with washers and sheet-bolts and nuts, etc. and including fixing the same to supporting frame with necessary hook-bolts, washers, putty etc. (excluding cost of sheets). (Payment to be made on area of finished work.) With all new fittings including the cost thereof. In roof. |
| 12 | Stopping roof leakages in C.I. or G.C.I. or asbestos roofing. With limpet and bitumen washer and putty . |
| 13 | Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. Eaves gutter made of 0.63 mm. sheets.(300mm End lapping). 225 mm. wide gutter. |
| 14 | Dismantling carefully wooden walling, flooring of ceiling and stacking dismantled materials as directed. |
| 15 | Partition of commercial ply as per design fitted and fixed complete (excluding the supporting framework but including necessary teak wood battens of size 40 mmx 25 mm): In Ground Floor. 4mm thick. |
| 16 | 6mm thick. |
| 17 | 12mm thick. |
| 18 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. Thickness of laminate 1 mm. |
| 19 | Painting block letters or digits in Black Japan or any approved paint as per direction. Size above 5 cm. and upto 7.5 cm. |
| 20 | Size above 7.5 cm. and upto 10 cm. |
| 21 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr |
| 22 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised, conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architecturaldrawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.Note : for estimate purpose construction wing may consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M]. |
| 23 | Supplying bubble free float glass of approved make and braand conforming to IS 2835-1987; (A) Clear 5 mm thick coloured / tinted / smoke glass. |
| 24 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. 3.90 metre height |
| 25 | Extra for additional 3.6 height or part thereof |
| 26 | Spot application for insecticides using oil baed spray for pest (for bags, cockroaches, silverfish, spider, termite,mosquitoes)to walls and ceiling etc.with chemical emulsion by admixing BIFENTHRIN with solvent by weight including spraying the emulsified [email protected] litres per sq.m. by a hand operated pressure pump on wall surfaces,ceiling,wood work,electrical lines etc.(Rate is per Sq.m. of the floor area while actual work may be done walls ceiling ,rack,partition and furniture etc.) |
| 27 | Cleaning and disinfecting upto 2000 litre Water Tank including masonryreservoir. |
| 28 | Cleaning and disinfecting Above 2000 litre Water Tank including masonryreservoir. |
| 29 | Preparation of drainage spout on roof for bituminous waterproofing treatment after required grading and shapingof the under bed with Cement Concrete (1:2:4) orCementMortar (1:4) as directed, Chamfering and moulding theparapet wall to form a bell mouth entry, if required andproviding full course treatment with bituminous felt tofacilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labouraccording to satisfaction of the Engineer - in - Charge.(This item shall be done for reparing works only and shallnot be used when original/renewal of tarfelting work isproposed to be undertaken).All floor |
| 30 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety. |
| 31 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur Variety. |
| 32 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 33 | Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth. |
| 34 | (b) In Superstructure, ground floor. |
| 35 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 36 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
| 37 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. For works in foundation and upto roof of ground floor/upto 4 m. Tor steel / Mild Steel. JSW/JSPL/SHYAM/ SRMB/ BMASL/ ELECROSTEEL /SSL. |
| 38 | Hire and labour charges for shuttering with centering and necessary staging upto 4m using approved stout props and thick hardwood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4m the equivalent floor height shall be taken as 4m and extra for works beyond the initial 4m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (a) 25 mm to 30mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 39 | (f) 25 mm to 30 mm shuttering without staging in foundation. |
| 40 | Supplying and laying Polythene Sheet (150gm / sq.m.) overdamp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 41 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:-a) With 0.5 mm thick sheet.(MALDA) |
| 42 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond thecompound, in conformity with the Municipal / Corporation Rules for such disposal, loading intotruck and cleaning the site in all respect as perdirection of Engineer in charge |
| 43 | Stripping off worn out plaster and raking out joints of walls, ceilings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 44 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:6 cement mortar. (a) 20 mm thick plaster (Internal surface) (i) In Ground Floor |
| 45 | ii In 1st floor |
| 46 | (b) 15 mm thick plaster(Exrernal serface)(i) Ground Floor |
| 47 | (ii) In 1st floor |
| 48 | With 1:4 cement mortar (c) 10 mm thick plaster (i) In Ground Floor |
| 49 | (ii) In 1st floor |
| 50 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lapping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(b) 32 mm thick shutters (Single leaf) |
| 51 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated. 200mm long x 10mm dia. Bolt. |
| 52 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed. (i) 250mm x 19mm dia bolt. |
| 53 | Anodised aluminium butt hinges of approved quality manufactured from extrudedsection conforming to I.S. specification (I.S. 205/66) and fitted and fixed withcadmium plated screws:100 x 75 x 4.0mm. |
| 54 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixedcomplete:(a) With continuous plate base (Hexagonal/ Round rod)(v) 125 mm grip x 12 mm dia rod. |
| 55 | Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixedcomplete.Medium (I.S.I. size 2) |
| 56 | Door stopper.(Brass) |
| 57 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.5mm thick clear glass. |
| 58 | Scraping of moss, blisters etc.thoroughly from exterior surface of wallsnecessitating the use of scraper, wire brush etc.(Payment against thisitem will be made only when this has been done on the specific directionof the Engineer-in-charge) |
| 59 | Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 60 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mmthickness in floor, lobby, stair, landing & treads etc. over 20mm (av.) thck base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessarypigments including grinding and Granite polishing as perdirection of Engineering -in -Charge in Ground Floor. {Whitecement and Pigment to be supplied by the Agency]With Chawk Dungri. Area of each tile exceeding 0.3sq.m. but not exceeding 0.6 sq.m. |
| 61 | Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative |
| 62 | Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. |
| 63 | Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of theEIC.In Ground Floor: (a) One Coat |
| 64 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.In Ground floor (Two Coat)Super Protective 100% Acrylic Emulsion. |
| 65 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC.(a) One Coat. i) Water based interior grade Acrylic Primer. |
| 66 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Luxury Quality |
| 67 | (a) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.(This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 68 | (b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) |
| 69 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface :With other than hi-gloss of approved quality. ii) Two coat (with any shade except white) |
| 70 | b) On steel or other metal surface: With other than hi-gloss of approved quality. Two coat (with any shade except white) |
| 71 | Taking out rain water down pipe. |
| 72 | Taking out rain water down pipes, removing chokages and refixing the samein position including mending good damages (of taking out and refixing) |
| 73 | Supplying, fitting & fixing UPVC pipes A –Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid /Bitumen/M-Seal etc) complete. A) UPVC Pipes:(i) 110 mm. Dia |
| 74 | B) UPVC Fittings:a) Plain Tee (i) 110 mm. Dia. |
| 75 | b) Bend 87.5 degree (i) 110 mm. Dia. |
| 76 | c) Shoe (i) 110 mm. Dia. |
| 77 | French polishing to wood work including preparing surface (ordinary gloss)(b) On old French polished surface including complete removal of the old polish. |
| 78 | Supplying, fitting and fixing Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar). |
| 79 | Supplying, fitting and fixing shower of approved brand and make. Hand Shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook (Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 80 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes 25 mm |
| 81 | Supply, fit and fix approved brand P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps 32 mm dia – 900mm long. |
| 82 | Clean silt of Inspection Pit. |
| 83 | Supply fit and fix 32 mm dia. polythene Flush Pipe of approved make with necessary fixing materials and clamps complete. |
| 84 | Supply, fit & fix 15 mm dia C.P. pillar cock of approved make and brand (equivalent to Code No.507, Model Tropical/sumthing special of ESSCO or similar brand) |
| 85 | Supply, fit and fix approved brand PVC connector white flexible with both end coupling with heavy brass over C.P. nut 15 mm dia. 600 mm long |
| 86 | Supply, fit & fix best quality Indian make mirror 5.5 mm. Thick with silvering as per ISI specifications supported on fibre glass frame of any colour frames size 550 mm x 400 mm. |
| 87 | Supplying, fitting & fixing glass shelf with aluminium guard rails -ordinary type with 5.5 mm sheet glass 450mm x 125mm. |
| 88 | Supplying, fitting and fixing liquid soap container.(a) Cromium plated. |
| 89 | Grouting Sealing of cracks/porous concrete by injection process through teflon nipples/grouting complete as per technical specifications and injecting High molecular weight low viscosity (< 350 centipoise (cps ) epoxy resin (STP/BASF/SIKA/ Fosroc/Krishna Conchem/pidilite/CICO as per Specifications ) as per approved FQP |
| 90 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge.All Floor. |
| 91 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.). Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) |
| 92 | Preparation of drainage spout on roof for bituminous waterproofing treatment after required grading and shaping of the under bed with Cement Concrete (1:2:4) or Cement Mortar (1:4) as directed, Chamfering and moulding the parapet wall to form a bell mouth entry, if required and providing full course treatment with bituminous felt to facilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labour according to satisfaction of the Engineer - in - Charge. All floor. |
| 93 | Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification. [Cement to be supplied by the Department] |
| 94 | Cost of Cement :PPC/PSC/OPC(33 grade) |
| 95 | Repairs to roof cracks with cement and sand mortar (1:4) including cutting grooves and cleaning cracks and grouting the cracks with neat cement before repairs. (Cement 0.63 Kg/Mtr. ) |
| 96 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur varity |
| 97 | Supplying, fitting & fixing polycarbonate sheet of approved make & brand conforming to IS: 14443-1997 and having 50 micron UV protection layer under co-extrusion technology, Fire rating being B-s1 as per EN13501-1 certification, fitted and fixed with 60mm wide aluminium channel section top and bottom member in dry-glaze sandwitch system, (unit wt. of top and bottom members: 0.375 kg/m & 0.69 kg/m) of approved brand and profile, EPDM quality rubber gaskets, anti dust tape, end closer \\"C\\" channel and 75 mm long Self tapping screw being drilled through the centre leg of the bottom section with nuts placed at 300 mm apart without anyway puncturing the polycarbonate sheet, EPDM Washer 16 mm dia & 3 mm thick washer etc complete strictly as per manufacturers specification and direction of Engineer-inCharge. (Payment to be made on area of finished work) . In Roof:- Natural/ Blue/Green/Bronze/Opal/Metallic grey colour With 2 wall 10 mm overall thickness (wt.1.70kg/sqm,Ugvalue being 3.1 W/m2K, Min. cold bending radius of 1200 mm) |
| 98 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finishedstructural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof For structural members of specified sections weighing less than 22.5 Kg./m |
| 99 | Renewing X.P.M. including taking out and refixing with new battens made of local wood of size 50mmx25mm and new screws etc. complete.(c) 20mm x 50mm strand 2.5mm x 1.25mm. |
| 100 | Supply & application for Reber grouting with HILTIHY 200 r Cchemical or equivalent including drilling holes (Dia of hole 12 mm for 8mm upto 12 mm rebar dia and depth 100 mm as per required size and removing dust from the holes by manual /mechanical air compressure as per direction of EIC .All complete (excluding the cost of Reinforcement) |
| 101 | Providing and erecting Fixed-type Frameless Glass Partition as per drawing.The glazing shall be done with 12 mm thick machine polished toughened glass.The partition is to be fixed with patch fittings, and / or, continuous polished teak wood glazing beads of approved shape & shade, as directed.All edges of the glass are to be finished with mirror polishing.The work is to include all necessary materials, accessories, labour, tools & tackles.\\"All materials should be approved by the EICExecuted elevation area is to be measured for finished work.\\" |
| 102 | Providing and fixing in position Frameless Glass Door made with 12 mm thick clear tioughned glass of Saint Gobain /pilkington/modiguard make fixed to floor and soffit of ceiling/ false ceiling rigidly and ai the centres whichever required in line and level with SS patch fittings floor spring of Dorma ozone or approved equivalent make .Finally the door will be finished with SS door handle with locking arrangement of Ozone /Hettich make with all enabling works complete as per drawing specification and direction of the Engineer in charge. |
| 103 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.In ground floor. |
| 104 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mmthickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] With Chawk Dungri.(i) Area of each tile upto 0.3 sq.m. |
| 105 | Cutting chase upto 125 x 150 mm. and subsequent mending of damages. In brick wall [Cement-3.6 Kg/Mtr] |
| 106 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. |
| 107 | Medium size plant of girth of exposed stem above 75 mm. but not exceeding 150 mm. lift upto 6 mtr. |
| 108 | Large plant of girth of exposed stem above 150 mm. but not exceeding 225 mm. lift upto 6 mtr. |
| 109 | Providing Anti-termite treatment to the soil under floor and walls at various building and structures of SMPK using IMIDACLOPRID 30.50 Sc as per IS 6313-3: Code of practrise for anti termite measures in building (Part-3 treatment for exisisting building with 5 years warranty from the date of completion of the work.The entire work is to be carried out as per specification .(Mode of measurement would be on floor area only through the actual work may be done on walls,ceiling etc.) |
| 110 | Dismantling of all assorted item that includes Wall partition/False Celling made of Wood, Ply Board, Masonite Board, Alluminium Partition, Door/Wondow frames, Glass etc. of any thickness with frame shifting and stacking the materials as decided by SMP Kolkata within a lead of 75 Mtr. all complete. |
| 111 | Taking out existing partition/ceiling of particle board, masonite board, ply board, soft board etc. of any thickness and refixing same in new position with necessary clamps making holes in walls, floor, roof and mending damages if any.[concrete plaster will be paid separately]. |
| 112 | M.S. structural works with hollow sections (square or rectangularshape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. ii) For other Structural works like galleries etc. |
| 113 | Supply of Fitting and Fixing of PVC White Vertical Blind.Made of Premium febrics in Width 5\\" Or 4 \\".minimum overlapping of 3/4 in fabric.top aluminium anodized rail of 1.4 mm thickness.2 inch wide channel with front lamination of same fabric .runners having stainless steel hooks with built-in shock spring and self alingning slip clutch.End control box composed of doubl;e gear system .Stainless steel spacers.bottom weight fully plastic covered linked with plastic based chain etc. incuding all complete. |
| 114 | Providing and supplying of unskilled labours for shifting office furtitures, files and other miscellaneous cleaning works and normal time of work 9 hours including one hour of recess. |
| 115 | (a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary.(Payment to be made on the length of individual lines of wire.). |
| 116 | Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.) (The rate is exclusive of the cost of posts). |
| 117 | Providing and fixing of false ceiling at all height including proving and fixing of frame work made of special sections, power pressed from M.S. Sheet and galvanized with zinc coating of 150 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre , to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre with 25 mm long dry wall screws @230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including joining and finishing to a flush finish of tapered and square edges of the board with recommended joining compound, joining tapes, finishing with joining compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacture's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-in-Charge but excluding the cost of painting with : (ISI Mark on Board). |
| 118 | Providing & installing POLYESTER INSULATING FILM as specified below of M/S Garware polyester or approved equivalent ) on glasses of doors / partitions including thorough cleaning of glass surfaces, scaffolding etc. with all labour & materials complete as per manufacturer's specifications & direction of the Engineerin charge. Frosted film 1.5 mil .(2micron). |
| 119 | Supply and Fixing of double door Vertical TPN MCCB Main Distribution Board (Enclosure 4way)with IP-42/43 protection, Copper Bus Bar for each phase, 2 Neutral bar, 2 Earth bar and S & F of 63A, FP 415V, 25kA Fixed thermal and Fixed magnetic setting MCCB as Incomer and 01 no. 40 Amp, 415 volt, TP, 10KA, C-type MCB as outgoing, 01 no. 40 Amp, 240 volt, SP, 10KA, C-type MCB as outgoing and 03 nos. 20 Amp 240 volt, SP, 10KA, C-type MCB as outgoing, Concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire , extended terminals/spreader link sets and neutral link & provision for earthing attachment. (For Main DB at Chummery Building ) |
| 120 | Supplying and Fixing double door SPN MCB DB [Enclosure 2+8 way] with IP-42/43 protection, Copper Bus Bar along with 40A, DP 240V, 10KA, C-type MCB as Incomer, 08 Nos. 6A to 32 A 240 volt, SP 10KA, C-type MCB as outgoing (suitable blank plate for rest), concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire and neutral link & provision for earthing attachment (Power DB at Chummery Building) |
| 121 | Supplying and fixing 240/415 V 40 A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (For New Building) |
| 122 | Supplying and Fixing double door SPN MCB DB [Enclosure 2+6 way] with IP-42/43 protection, Copper Bus Bar along with 20A, DP 240V, 10KA, C-type MCB as Incomer, 06 Nos. 6A to 32 A 240 volt, SP 10KA, C-type MCB as outgoing (suitable blank plate for rest), concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire and neutral link & provision for earthing attachment (Light DB at Chummery Building: 2, Security Room: 1, Garage Room & Driver Rest Room(new bldg): 1 |
| 123 | Distribution wiring from VTPN DB to Lighting SPN DB (For Chamery Building), VTPN to SPN DB (For Security Room), VTPN to SPN DB (For Garage Room & Driver Rest Room) &VTPN DB to Street light SPN DB (For Chamery Building street light) with 1.1KV grade single core stranded FRLS, PVC insulated and unsheathed 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as copper wire in suitable size of PVC rigid conduit pipe(incd. S & F of PVC rigid conduit) embedded in wall/ceiling, duly concealed incl. necessary fittings as required and mending good damages. |
| 124 | Distribution wiring from VTPN DB to Lighting SPN DB (For Chamery Building), VTPN to SPN DB (For Security Room), VTPN to SPN DB (For Garage Room & Driver Rest Room) with 1.1KV grade single core stranded FRLS, PVC insulated and unsheathed 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as copper wire in suitable size of PVC rigid conduit pipe(incd. S & F of PVC rigid conduit) above false ceiling incl. necessary fittings, GI Binding wire etc. as required, complete in all respect and mending good damages. |
| 125 | Distribution wiring from VTPN DB to Power SPN DB (For Chamery Building), with 1.1KV grade single core stranded FRLS, PVC insulated and unsheathed 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC as copper wire in suitable size of PVC rigid conduit pipe(incd. S & F of PVC rigid conduit) embedded in wall/ceiling, duly concealed incl. necessary fittings as required and mending good damages. |
| 126 | Distribution wiring from VTPN DB to Power SPN DB (For Chamery Building), with 1.1KV grade single core stranded FRLS, PVC insulated and unsheathed 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC as copper wire in suitable size of PVC rigid conduit pipe(incd. S & F of PVC rigid conduit) above false ceiling incl. necessary fittings, GI Binding wire etc. as required, complete in all respect and mending good damages. |
| 127 | Supply and delivery of 1.1 KV grade 4 core 25 sq.mm. XLPE insulated armoured Aluminium cable comply to IS:7908(Part-1)/1988 or latest amendment if any |
| 128 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly ammed |
| 129 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4 core 25 sq mm. |
| 130 | Finishing the end of 4 core 25 sq. mm. XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 131 | Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC) for 3½ / 4 core 25-35 sqmm cable |
| 132 | Supply and delivery of 1.1 KV grade 4 core 10 sq.mm. XLPE insulated armoured Aluminium cable comply to IS:7908(Part-1)/1988 or latest amendment if any for Street Light. |
| 133 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly ammed |
| 134 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4 core 10 sq mm. |
| 135 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 10 sq mm |
| 136 | Distribution wiring from SPN DB to Power Socket 15/5A 5 Pin plug point, Computer Plug set and TV Point (Chamery Building) and Light SPN DB to Switch Board (Chamery Building) with 1.1KV grade single core stranded FRLS, PVC insulated and unsheathed 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC, copper wire in suitable size of PVC rigid conduit pipe (incd. S & F of PVC rigid conduit) embedded in wall/ceiling, duly concealed incl. necessary fittings as required and mending good damages. |
| 137 | Distribution wiring from SPN DB to Power Socket 15/5A 5 Pin plug point, Computer Plug set and TV Point (Chamery Building) and Light SPN DB to Switch Board (Chamery Building) with 1.1KV grade single core stranded FRLS, PVC insulated and unsheathed 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC, copper wire in suitable size of PVC rigid conduit pipe (incd. S & F of PVC rigid conduit) above false ceiling incl. necessary fittings, GI Binding wire etc. as required, complete in all respect and mending good damages. |
| 138 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Separate 6/16 amp Power point) |
| 139 | Supply & Fixing 4 nos. 240 V, 6 A, 3 pin Modular type plug socket with 4 no 6A Modular switch(each set), 10A Modular switch type MCB (C-Curve) without plug top on GI Modular type switch board embedded in wall with Module top cover plate incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (TV Point/Computor Point) |
| 140 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, in suitable size of PVC rigid conduit pipe (incd. S & F for concealed portion) complete with all accessories, embedded in wall/ceiling incl. necessary fittings, S&F ceiling rose , Holder etc., as required, and to light , fan points & Calling bell with Modular type switch fixed on Modular GI switch board providing neutral link in S.B with top cover plate flushed in wall/partition incl. mending good damages to original finish (S & F of modular switch, top cover, GI board etc. including all accessories complete in all respect).(false ceiling portion through prelaid PVC rigid conduit) (Average run 8 mtr.) (Single switch-single utility) |
| 141 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to 240 V 6A, 3 pin plug point incl. S&F 240 V 6A, 3 pin Modular type plug socket & Modular type switch incl. S&F earth continuity wire, fixed on Module GI switch board with Module top cover plate flushed in wall incl. mending good damages to original finish ( On Board ) |
| 142 | Supply, Installation, Testing & Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, modular socket type (siutable for BLDC Fan) electronic Fan regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 143 | Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required. 300 mm sweep RPM 1400 |
| 144 | Supplying & Fixing 240V AC/DC superior type Multitune (min 10 no.) call bell with selector switch for single-multi tune mode, battery operated incd. necessary accessories complete in all respect. |
| 145 | Supply of LED Batten luminaire for indoor application including LED lamps, constant current Driver, internal surge protection , electronic components in pre wired condition with all accessories . Luminaire is made up of aluminium channel housing with milky white diffuser . Lumen output of the fittings is 2000 lumens, Luminaire Efficacy 100 lm/Watt, CCT of 6500 deg k ( +/- 500 Deg K ) Luminaire is suitable to operate in input voltage range of 140 V to 300 V with input power supply of 220-240V, 1 phase, 50Hz AC and in operating temperature range of 0°C to 45°C . Lifetime of the fixture should be at least 25,000 burning hours at L70B50 at 25 degree centigrade .Luminaire is IP 20 protected . Luminaire & Driver units are BIS approved. |
| 146 | Fixing only single LED tube light fitting complete with all accessories directly on wall by screws etc. |
| 147 | Supply of 10 W LED light bulb for indoor application |
| 148 | Fixing only single LED bulb light fitting complete with all accessories directly on wall by screws etc. |
| 149 | Supply and fixing as per specification polycarbonate batten holder/angle holder of approved make with necessary materials complete |
| 150 | Supply of LED Street Light luminaire for outdoor with internal surge protection with 10kV SPD, electronic components in pre wired condition with all accessories . Luminaire is made up of aluminium housing with IP 66 and IK 08 protection. System lumen output of the fittings is min 10000 lumens with system efficacy >=100 lm/Watt. CCT of 5700 deg k ( +/- 500 Deg K ). Luminaire is suitable to operate in input voltage range of 140 V to 270 V with input power supply of 220-240V, 1 phase, 50Hz AC and in operating temperature range of 0°C to 35°C . Lifetime of the fixture should be at least 50,000 burning hours at L70B50 at 25 degree centigrade. Power Factor is 0.95. Luminaire & Driver units are BIS approved. (For existing railpole and perimeter of office buildng) |
| 151 | Fixing of above street light luminaries on aborementioned suitable dia pipe along with necessary connection including all accessories complete in all respect. |
| 152 | Supply & Fixing of suitable dia GI Pipe(ISI/TATA) of total length 2m having suitable bend to accommodate above street lights with GI clamps, GI nuts & bolts, complete in all respect. The GI Pipes are to be fixed at signage boards/ wall for street light as per instruction. The luminaries to be connected with S&F of necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire |
| 153 | Erection of metallic pole of following length in cemente 1:3:6 (c Cement : 3 Coarse : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 meter and upto 12.00 meter |
| 154 | Supply & Fixing of LED flood light luminaire for outdoor with internal surge protection with 10kV SPD, electronic components in pre wired condition with all accessories . Luminaire is made up of Aluminum housing with IP 66 and IK 07 protection. System lumen output of the fittings is min 7000 lumens with system efficacy >=90 lm/Watt. CCT of 5700 deg k ( +/- 500 Deg K ). Luminaire is suitable to operate in input voltage range of 140 V to 270 V with input power supply of 220-240V, 1 phase, 50Hz AC and in operating temperature range of 0°C to 35°C . Lifetime of the fixture should be at least 50,000 burning hours at L70B50 at 25 degree centigrade. Power Factor is 0.90 Luminaire & Driver units are BIS approved. (For two numbers signage board) |
| 155 | Supply ,delivery and fixing of Hot Dip Galvanized Loop-in-loop-out box [with minimum coating thickness of 85 micron] should have suitable terminal arrangement for connecting 2/3 cables of size 16 mm2 / 25 mm 2 , 01 no. 6 A SPNMCB and earth strip / earth wire. |
| 156 | Supply & Erection of 3000 mm high Post Top pole with mounting made of circular mild steel pipe. There should be aluminum service door, which is to be contoured to the shape of the pole with silicone rubber gasket, to house built-in control box. The control gear tray is prewired with 2.5 Sq.mm cable/wire, 6A SP MCB and 32A stud type 4 way terminal block for loop-in / loop-out arrangement, 5A 2 Way terminal connector and provision for earthing. S&F Mild steel mounting plate. Steel of grade E250 to IS 2062 : 2011 with 4 holes to suit suitble bolts of grade 4.6 at RCC (S&F). This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the foundation. All dimension are within +/- 5% tolerance. After fabrication, entire pole is shot blasted. The pole is coated with zinc rich primer & pure polyester powder coating or epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint (coating thickness 60-80 microns). The Pole shall be provided with Graphite grey / Anthracite grey / Black as as per instruction of Engineer. The pole should look like as per attached drawing. |
| 157 | Supply of Post Top integrated LED luminaires of 45 watt with system efficacy having symmetrical light distribution. pressure die-cast aluminum housing for durability and has a powder-coated finish suitable for mounting on light post. Protection class IP65. Mechanical resistance IK08. Colour temperature 5700K, Colour rendering index (CRI)>70. LED module with expected service life of at least 50,000 operating hours. Should be prewired with LED driver and suitable for operating on 240V (having operating voltage range 120-270V AC), 50Hz single phase ac supply. The luminarie & driver should be BIS Certified. The look of luminarie should be as per attached drawing . (Garden light). |
| 158 | Fixing of above Post top LED luminaires along with all accessories. |
| 159 | Supply of Bollard having minimum lenghth of 475mm and not more than 600mm with dia min 180mm. The light installed should be min 9W LED, CRI >= 70, Colour Temperature = 3000K, operating voltage range 100-277V, 50 Hz. Driver of LED light should be integral with P.F. >=0.90, THD< 10%, having necessary Surge Protection and IP65 & IK 09 protection. Light out put should be symmetrical. The body of bollard should be Die-cast Aluminum with extruded aluminum tube with power coating. Colour should be Black or Gray. LED light should have diffuser. Bollard should come with suitable base plate, nut & bolts. |
| 160 | Erection of Bollard light with base plate on grouted bolt within CC foundation of dimension 200mm X 200mm X 450 mm (150mm above ground level) and having 450 X 450 X 150 mm thick CC base block with hard jhama metal including 3 mm thick neat cemented finish and provisioning entry/exit of suitable length & dia PVC pipe (incld. S & F) for loop-in & loop-out and/or S & F of GI Loop Box filling up the excavated earth pit with shifted soil and ramming properly. Suitable no. foundation bolt should be grouted on the foundation on which base plate will be fixed. |
| 161 | Supply and installation of Time Switch Controller Distribution Box Set for max 415V, 32A load with Contactor and MCB, to be used For Automatic Switching On/Off of lights. Package Includes One Timer, 32A Contactor, and 32A 4P MCB, Bypass switch, Terminal Block, pre-wired and all fitted into enclosure with IP 65 protection. The timer DB should be operated in Automatic and Manual mode. (Rail pole street light/ gardenlight/ building peripheral light) |
| 162 | Dismantling of existing wiring, DBs, lights,garden lamp posts, bollards,AC, Geyser etc. Complete handed over to the Office In-Charge of HSFO Berhampore of HSD Dept. |
| 163 | Supplying and fixing 125 Amps, 415V, TPN on load front operated Changeover switch with Terminal covers and phase barriers for safety, Door interlock and padlocking arrangement, protection IP43, includes arc chute plates to quench arcs, IS/IEC 60947-3 standards with Sheet Steel enclosure on angle Iron frame on wall with nuts bolts etc |
| 164 | Dismantling of existing MV Panel and Main switches including safe disconnection of all incoming and outgoing cables, removal of the panel from the wall, and shifting the same to a safe location within the premises as directed by the Engineer-in-Charge. Shifting of MV Panel including disconnection of all incoming and outgoing cables, removal of the panel from the wall, and refixing the same at the desired location on angle iron frame with reconnection of all cables with proper end termination of cables as required, complete in all respects as per the direction of the Engineer-in-Charge. |
| 165 | Earthing with 50mm. Dia. GI pipe ISI Medium 3.64 mm thick, 3.04 mtrs. Long and 1x4 SWG GI earth wire (4mtrs long ), 13 mm. dia x 80 mm. long GI nuts and bolts, double washer, incl. S&F 65 mm. dia GI pipe protection (1mtr. Long ) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtrs below the ground level including providing necessary masonry enclosure of overall size 86.36 cm x 86.36 cm x 46 cm deep ( below the ground level), CI hinged inspection cover of size 36.56 cm x 36.56 cm and treating of soil by using salt and charcoal as required. Earthing work is to be carried out as per IS. |
| 166 | Connecting from earth pit to earth pit, earth station to earth bus bar and Main Panel, cable tray at inclusive of S&F 25mm x 6 mm Galvanized (Hot Dip) MS flat under the ground level/on wall/floor with GI saddle as required inclusive drilling holes, bolts, nuts, washers etc. and mending good the damages as required. |
| 167 | Supplying & fixing earth bus bar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the bus bar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 168 | Connecting from the equipments/Earth station to earth bus bar including S & F GI (Hot Dip) wire of size as below in wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid GI wire: No. 6 SWG Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail