| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. a) All kinds of soil 90% |
| 3 | b) Ordinary Rock 10% |
| 4 | Dumping stone excluding cost of stones in Horizontal on level |
| 5 | Dumping stone excluding cost of stones on Slopes (Behind pitching |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources |
| 8 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 9 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Random rubble masonry with hard stone laid dry in foundation, plinth & walls Laid without bond stone |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size) |
| 14 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 16 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
| 17 | 20 mm cement plaster of mix : - 1:4 (1 cement: 4 coarse sand) |
| 18 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 19 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 20 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 21 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 22 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 23 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class Kail wood |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 25 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profilesduly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process ofrequired length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriated imension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusionwelded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixinghardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wallshall be filled with weather proof silicon sealant over backer rod of required size and of approved quality,all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes andsilicon sealant shall be paid separately). Variation in profile dimension in higher side shall be acceptedbut no extra payment on this account shall be made. |
| 26 | Providing and fixing double glass unit DGU comprising of 6 mm thick glass on either with 12 mm thick insert gas gaping. The DGU shall be process from reputed glass processor. |
| 27 | Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge,complete with; Local willow wood |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form work for :a) Foundations, footings, bases for columns |
| 29 | b) Columns, piers, abutments, pillars, posts and struts |
| 30 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 31 | d) Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 32 | Providing and fixing 12mm thick prelaminated flooring of approved brand as per the direction of Engineer incharge, complete Job AC-4 Including carriage complete Job |
| 33 | Providing and fixing of 100mm pine wood plain lining tongued grooved, including wooden plugs complete with necessary screw and priming coat on unexposed surface 10mm thick. |
| 34 | Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame,backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): 12 mm thick |
| 35 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I.channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimetre channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimetre of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimetre channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) 11 (Board with BIS certification marks). |
| 36 | Thermal Insullation for wall / roofing with acoustic form for fixed with wooden frame as per the direction of the Engineer in charge 50mm thick complete Job |
| 37 | Providing and laying of Acoustic fabric cloth that absorbs sound and ambient noise with fitting all complete Job |
| 38 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including |
| 39 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diametre with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint onoverlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m3 |
| 40 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm |
| 41 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm |
| 42 | 150x10 mm |
| 43 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm |
| 44 | 100mm |
| 45 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 46 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.Anodized(AC 15) aluminium |
| 47 | Carriage of material from source to site of work by Mechnical Transport including loading unloading and stacking. a) Cement and steel an avg lead 25 Km |
| 48 | b) Sand an avg lead 40Km |
| 49 | c) Stone aggregate an avg lead 40Km |
| 50 | d) Stone an avg lead 10Km |
| 51 | e) Earth an avg lead 03Km (Disposal) |
| 52 | Supply and fixing of 25 mm size of PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required ( in Slab and beams only) |
| 53 | Providing and fixing junction box ( in slab only) |
| 54 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 55 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 56 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 57 | 2 X 2.5 Sq. Mm +1 X 2.5 Sq.mm earth wire |
| 58 | 2 X 10 Sq mm + 1 X 6 Sq mm earth wire |
| 59 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1X 1.5 Sq mm |
| 60 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 61 | 3 pin 5/6 A socket outlet |
| 62 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 63 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 64 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 65 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 66 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator) 12 way , Double door |
| 67 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 amp. |
| 68 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 69 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 70 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A,30KA,FPMCCB |
| 71 | Change over switch 100Amp MCCB Type FP |
| 72 | Fabrication, supplying , installation testing and commissioning of following pannel made out of 2 mm thick M.S sheet, wall mounted, vermin & dust proof outdoor type with lockable type hinged doors duly painted with provision for fixing of 1No including supply and fixing 2 set of Aluninium Bus bar, and strip for housing MCB's 12 Nos, MF Digital Meter and other allied accessories as required. ( Make as per annexure) |
| 73 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPN 63amp |
| 74 | Supplying and fixing of 70 watt LED Street Light complete light with GI pipe bracket duly embeded along the parapet/ wall. Wipro LR13 - 781 - XXX- 57- GI or equivalent approved make |
| 75 | Supplying and fixing following luminaries as required LL20-111-XXX-65NE3 wipro 10 watt LED tube light fitting equivalent make and model Philips/Crompton Greaves. |
| 76 | 10 watt LED tube light fitting LL20-221-XXX-65NE3 of wipro or equivalent make and model Philips/Crompton Greaves |
| 77 | LED concelead light fittings of wipro or equivalent make and model philips/Crompton Greaves. Please Enable Macros to View BoQ information |