| 1 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch Board both on surface) |
| 2 | 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC |
| 3 | i) Average run 6 mtr |
| 4 | ii) Average run 8 mtr |
| 5 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated &unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface) |
| 6 | Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. |
| 7 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 8 | 2 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 9 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 10 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand / Havells / Siemens/L&T) |
| 11 | (2+8 Way) Enclosure (DHDPSNODRW08) |
| 12 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Havells / Siemens/L&T) . |
| 13 | Single pole 6-32A MCB |
| 14 | Double Pole 40A MCB Isolator |
| 15 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) |
| 16 | 2 Bars 230V,63A |
| 17 | Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 63 A |
| 18 | Supplying and fixing 240V changeover with sheet steel enclosure on angle iron frame on wall with nuts,holes,bolts etc |
| 19 | 63 Amp (Havells Make) |
| 20 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitablesize of MS fastener |
| 21 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm(12'') |
| 22 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al : 30 cm Exhaust fan (12\\") |
| 23 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire |
| 24 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc |
| 25 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 26 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm infloor/pavement/wall etc. |
| 27 | Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode |
| 28 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 29 | No. 6 SWG |
| 30 | Light Fittings &Fixtures (Non Schedule Items) (B) |
| 31 | PVC Aluminium Armoured Cable 16 sq.mm , 2core.Havells Make |
| 32 | LED Tubelight SuperNova Glamtube 36W,3000K (LHEWAJPGPV1A36),Havells Make. |
| 33 | Supplying of Ceiling Fan Breezer ES Ceiling ,Sweep 1200 mm Pearl White (FSCBR1SMAU48),Havells Make. |
| 34 | Supplying of Ventillating Exhaust Fan (Double Ball), Refresh Air-DBB Neo ,300 mm (FSVRFSTDBG12),Havells Make. |
| 35 | Supplying of LED Surface Light 1X1 surface mounted luminairies which provides soft light and glare free symmetrical illumination PLANOSUR1X1PLS15WLED840SG2,Havells Make. |
| 36 | Supplying of Flood Light BVP281LED094 CW FG SY5WB75 Watt SPDV1,Philips Make. |
| 37 | Add 18% GST on A |
| 38 | Add Labour Cess @ 1% Please Enable Macros to View BoQ information |