|
| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed. |
| 2 | Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed. |
| 3 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises, complete all as specified and directed. |
| 4 | Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for, complete all as specified and as directed. |
| 5 | Demolition of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 6 | Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 7 | Taking up or down steel tubing 20mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 8 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed |
| 9 | Dismantling of Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings including ridges and removal of rubbish, complete all as specified and directed. |
| 10 | Dismantling of rolled mild steel as in trusses, tubular purlins, rafters etc and refixing of purlins, rafters or trusses including necessary cleats etc., complete all as specified and as directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified & directed. |
| 12 | Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 13 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. |
| 14 | Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 15 | PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified. |
| 16 | PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof, surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 17 | RCC M-25 (Design mix) as in beams, cantilever, bressummers, lintels over 1.50m span complete all as specified and directed. |
| 18 | RCC M-25 (Design mix) as in Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed |
| 19 | Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in cover slab for MH / septic tank etc, set in CM 1:4 including necessary form work, complete all as specified and directed. Note :- Reinforcement shall be measured and paid seperately under respective items. |
| 20 | RCC 1:1.5:3 type A-1 (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork, complete all as specified and directed. |
| 21 | Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 22 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed. |
| 23 | Brick work with fly ash (Old Size bricks) sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed. |
| 24 | Brick work with sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:4, complete all as specified and as directed. |
| 25 | Brick work with fly ash bricks (Old Size bricks), sub class'B' bricks straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4, complete all as specified and directed. |
| 26 | 5mm thick rendering on concrete surface of ceiling, chajjas, soffits of slabs etc. in CM 1:3 finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 27 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 28 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement including preparation of new plastered surfaces of walls and applying 2mm thick wall care putty, making the surface smooth & applying two coats of oil emulsion paint over a coat of priming paint , complete all as specified and directed. |
| 29 | 15mm thick rendering cement plaster in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC finished even and smooth without using extra cement & applying two coats of exterior emulsion weather proof paint (Apex) over a coat of primer, complete all as specified and directed. |
| 30 | 15mm thick rendering cement plaster in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid for separately. |
| 31 | 15mm thick rendering cement plaster in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar 1:4, complete all as specified and directed. |
| 32 | 20mm thick cement plaster in cement mortar 1:4 on concrete surfaces, finished even and smooth using WPC liquid as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement, complete all as specified & directed. |
| 33 | 10mm thick rendering on fascia / edging / ceiling of Chajjas, roof projections etc, making the edges in line, in true shape in CM 1:3 and finishing the surface without using extra cement, complete all as specified and directed. |
| 34 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 35 | Preparation of surfaces and applying first coat of fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 300%, tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shåll resist 10 bars of hydrostatic pressure & reduce surface temperature upto 10 degree Celsius with 33% dilution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 gsm/sqm and pasting it properly with overlap of 50mm and allow it to dry, applying second of undiluted coat @ 0.45 Itr/sqm. Applying third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacturer or authorised applicator, complete all as specified and directed. |
| 36 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ceosetory windows & other Frames/chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 37 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ceosetory windows & other Frames/chowkhat of size 50x100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 38 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ceosetory windows & other Frames/chowkhat of size 50x125mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 39 | 35mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 40 | 30mm thick factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately). |
| 41 | 35mm thick factory made wire mesh solid WPC door Shutter prefinished with UV coating consisting of density 650 kg/cum manufactured by an ISO-9001-2015 certified company, door to paneled with SS mosquito mesh and XTN aluminium mesh for additional strength and safety purpose. (Conforming as per IS:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 Nos SS butt hinges of size 100mmx25mmx2mm and 32mm long steel screws drilled suitably to pass through, other hardware should be fixed with 19x6 mm size steel screws etc., complete all as per directed, manufacturers specifications & drawings. Note:Fixture/fittings other than mentioned in item shall be measured & paid under relevant item. |
| 42 | Box type Steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 and making good to disturbed area in same finish, complete all as specified and directed. |
| 43 | 35mm thick single piece factory made wire gauged door shutters and including of wire cloth (stainless steel & aluminium XPM) & 5mm thick PVC Sheets high pressure compact laminate on both side of approved colour on frame made out of MS tube & 19 SWG size 19x19mm complete in all repect with lock rail & beautified by PVC beading all around and fixed PVC solvent complete as per Drg No. CEPZ/TD-378/ Sheet 1/1 dated 27/12/2011. Please Enable Macros to View BoQ information |
| 44 | 35mm thick single piece factory made wire gauged door shutters and including of wire cloth (stainless steel & aluminium XPM) & 5mm thick PVC Sheets high pressure compact laminate on both side of approved colour on frame made out of MS tube & 19 SWG size 19x19mm complete in all repect with lock rail & beautified by PVC beading all around and fixed PVC solvent complete as per Drg No. CEPZ/TD-378/ Sheet 1/1 dated 27/12/2011. Please Enable Macros to View BoQ information |