| 1 | Site Clearance & surface dressing not exc 15cm deep in soft/loose soil complete all as specified and directed. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in any kind of soil complete all as specified and directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth or n exc 10 sqm on pland and n exc 1.5m in depth for foundation of poles struts, stays etc or laying underground cable etc in soft/loose soil & getting out complete all as specified and directed. |
| 4 | M&L for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone agg) in foundation, mass concrete and filiings complete all as specified and directed. |
| 5 | M&L for providing reinforcement cement concrete, M-25 (using 20mm graded stone agg)as in footing, foundation,beams, plinth beams, base for columns and mass concrete etc complete all as specified and directed. |
| 6 | M&L for providing reinforcement cement concrete, M-25 (using 20mm graded stone agg) as in columns complete all as specified and directed. |
| 7 | M&L for providing reinforcement cement concrete, M-25 (using 20mm graded stone agg) as in beams, cantilevers, bressumers, lintel over 1.5m span complete all as specified and directed. |
| 8 | M&L for providing reinforcement cement concrete in M-25 (using 20mm graded stone agg) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 9 | M&L for providing reinforcement cement concrete, M-25 (using 20mm graded stone agg) as in Chajja complete all as specified and directed. |
| 10 | S&F mild steel TMT bars 10mm dia and over , cut to length, bent to shape requred, including cranking bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete all as specified and directed. |
| 11 | S&F mild steel TMT bars 6 to 8 mm dia , cut to length, bent to shape requred, including cranking bending and binding with mild steel (anneal) wire not less than 0.90mm dia complete all as specified and directed. |
| 12 | S&F mild steel TMT bars 6 to 10mm dia a as in stirrups, spacers and binders complete all as specified and directed. |
| 13 | Form work to side of concrete in foundation, footing base, base of columns, side and soffits of plinth beam and simillar work complete all as specified and directed. |
| 14 | Form work for flat rough finished surfaces of concrete to sides of columns complete all as specified and directed. |
| 15 | Form work to side and soffits of floor beams. Lintel beam, roof beam , landing, waist slabs, chajja railing and similar work complete all as specified and directed. |
| 16 | Form work for flat rough finished surfaces of concrete to soffits of suspended slabs such as roof slabs, floor slabs landings and similar works not exc 200mm thick (Horizontal or slopping) complete all as specified and directed. |
| 17 | Form work for flat rough finished surfaces of concrete to Chullah hood Chajja, troughs and similar items including edges complete all as specified and directed. |
| 18 | Form work for rough finished surfaces of concrete to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, and sides of RCC/PCC bands in walls and similar works exc 10cm but n. exc 20cm wide complete all as specified and directed. |
| 19 | M&L for 15mm plaster in CM 1:3 over the concrete surface (while the concrete is green) with approved water proofing compound in proportion as recommended by the manufacturer complete all as specified and directed.(Note : WPC shall be measured saperately on supply only) |
| 20 | Supply only integral water proofing compound complete all as specified and directed. |
| 21 | M & L brick work with Fly Ash old size bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 22 | M&L for providing old size Burnt clay bricks Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 23 | M&L hardcore of gauge n.exc. 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface for plinth protection complete all as specified and directed. |
| 24 | Removing excavated material n exc. 50m and deposited complete all as specified and directed. |
| 25 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed. |
| 26 | M&L for Rendering 15mm thick in CM 1:4 in two layers (1st layer 10mm th and 2nd layer 5mm th with Water proofing compound) on other than fair faces of brick work finished even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for Rendering 15mm thick in CM 1:6 on fair faces of brick work finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L for rendering 5mm thick in cement mortar 1:3 on ceiling finished even and smooth with using water proofing compund as per manufacturer instruction complete all as specified and directed. |
| 29 | M&L for providing 100mm thick cement concrete 1:4:8 type D2 (Using 40mm graded stone agg), as in sub base in floor/paving etc complete all as specified and directed. |
| 30 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm with putty finish over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 31 | M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of alkali resistant primer and 3mm thick wall care putty finish complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed. |
| 32 | M&L preparation of newly plastered ceiling surface and applying three coat of white wash complete all as specified and directed. |
| 33 | M&L for 75mm thick Plain Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) laid in panels n. exc 1.50m long and in ulternate bays including necessary form work complete all as specified and directed. |
| 34 | M&L Machine cut kota stone slab flooring 20-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and Mirror polishing on Kota stone work to give high gloss granite finish and 20mm thick screed bed in CM 1:6 complete complete all as specified and directed. |
| 35 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 36 | Supplying and fixing steel windows/Ventilators n. less than 1.20 mm thick Box type (primer coated) ERW hollow ‘P’ section of size 60mmx25mm single rebated comprises of glazed and skeleton shutter EWR Sec 50mmx20mm and 1mm thick and two open able leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of EWR box ‘T’ section of size 60mmx25mm and 1.25mm thick. Each window including following fittings welded to failed shutter :- (a) Holdfasts 150mm long 12mm x 3mm made to shape – 04 Nos per window (b) Handle of Z Sec 20mmx25mm, 100mm long – 1 Nos of leaf, (c) MS tower bolt 150mm long 02 Nos per leaf (d) ‘Z’ sec 20mm x 25mm, 100 long stopper – 01 Nos per leaf, (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges – 01 Nos per leaf (f) MS pintal hinges of size 75mmx12mm – 02 Nos per leaf (g) fabrication and fixing arrangement complete. |
| 37 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 38 | M&L for 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exceeding 0.5 Sqm in each panes complete all as specified and directed. |
| 39 | M&L for providing two coats of painting with synthetic enamel paint over a coats of red oxide primer on new steel surface after preparation complete all as specified and directed. Please Enable Macros to View BoQ information |
| 40 | M&L for providing two coats of painting with synthetic enamel paint over a coats of red oxide primer on new steel surface after preparation complete all as specified and directed. Please Enable Macros to View BoQ information |