| 1 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2.27) |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 3 | 1:3:6 (1 cement : 3 coarse sand (zone-iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.5) |
| 4 | 1:5:10 (1 cement : 5 coarse sand (zone-iii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.10) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 6 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 8 | Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 10 | Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) |
| 11 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 12 | Particle Board 12 mm thick |
| 13 | Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked (DSR 9.7.5.1) |
| 14 | Float glass panes |
| 15 | 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). (DSR 9.7.7.2) |
| 16 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (DSR 9.83) |
| 17 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 18 | 300x16 mm (DSR 9.96.1) |
| 19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 20 | 200x10 mm (DSR 9.97.3) |
| 21 | 150x10 mm (DSR 9.97.4) |
| 22 | 100x10 mm (DSR 9.97.5) |
| 23 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 24 | 125mm (DSR 9.100.1) |
| 25 | 100 mm (DSR 9.100.2) |
| 26 | Providing and fixing aluminium hanging floor door stopper, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 27 | Twin rubber stopper (DSR 9.101.2) |
| 28 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 29 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) |
| 30 | Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : |
| 31 | Light shade pigment using white cement (DSR 11.16.1) |
| 32 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4(1 cement : 4 coarse sand) : |
| 33 | 25 mm thick (DSR 11.26.1) |
| 34 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. (DSR 11.31) |
| 35 | Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre. (DSR 11.32) |
| 36 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using Gl slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm Gl adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 37 | Gl Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (DSR 12.52.1) |
| 38 | 12 mm cement plaster |
| 39 | 1:4 (1 cement : 4 fine sand) (DSR 13.1.1) |
| 40 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 41 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) |
| 42 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 43 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. (DSR 13.62.1) |
| 44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) |
| 45 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge. |
| 46 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) (DSR 15.2.1) |
| 47 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 48 | For thickness of tiles above 25 mm and up to 40 mm (DSR 15.23.2) |
| 49 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR 15.56) |
| 50 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR 15.57) |
| 51 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR 15.60) |
| 52 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be mooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
| 53 | For fixed portion |
| 54 | Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) |
| 55 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 56 | Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) |
| 57 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (DSR 21.17) |
| 58 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main 'T'. The system should rest on periphery walls /partitions with the help of Gl perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 59 | With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) (DSR 26.27.1) |
| 60 | Providing and fixing 40mm thick PUF celling Panels continous line sandwitch with 0.40 mm thick TCT PPGI,( 120 gm, 240 mpa, coated sheet of make JSW, Satmax, Lloyd, sintex, Mectec, Rinac (Conforming to IS: 12436) on both side having polyurethane foam of density 40± 2kg/cum between sheets. The panel sheet shall have corugated sheet at top having crest of approx 30mm and the bottom shall be plane sheet with ribs. The panel sheet have one meter width and panel length as per length of room without any joint. The panel shall be fixed in toungue and groove joint with help of flashing comprising of PPGI U channels, L- section, end cap ,POP revits , screws and other accessories complete in all respect. The PUF shall be CFC free and ozone friendly made with blowing agent will be N-Pantene. The gap at joint shall be filled with silicon sealant of approved brand (Macoy, pidilite or its equivalent ).These panels shall be fixed in alignment and plumb complete in all respect to the entire satisfaction to the Engineer incharge. (NS) |
| 61 | Dismantling Puff Panels in lining of walls partitions roof excluding supporting members but including stacking within 50 meters lead : (NS) Please Enable Macros to View BoQ information |