| 1 | Maintenance & operation of Fire fighting system, fire Alaram system and PA system of Ch. Brahm Prakash Ayurved Charak Sansthan, Khera Dabar, New Delhi comprising of following services on all days of the month i/c Sundays and holidays i/c attending day to day complaint, rectification of fault, up-keeping and preventive maintenance of FF, FA & PA system equipment cleaning of detector, hooter, MCP, panel, different type of motors different types valves of fire fighting pipe line need to operational in all time etc complete as reqd. |
| 2 | Fire Fighting System i/c Fire Pumps, Fire Engine , Fire Alarm & PA system (round the clock)- etc. For Fire Fighting System i/c Fire Pumps, Fire Engine , Fire Alarm & PA system (round the clock)Operator cum mechanics– 3 Nos. (One No. in each shift) (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM)Khallasi - 1 No. In General Shift |
| 3 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
| 4 | 150 mm. Dia |
| 5 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 6 | 25 mm dia |
| 7 | 80 mm dia |
| 8 | 100 mm dia |
| 9 | 150 mm dia |
| 10 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/ Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required |
| 11 | Single headed Stainless steel |
| 12 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 13 | 80 mm dia |
| 14 | 100 mm dia |
| 15 | 150 mm dia |
| 16 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 17 | 80 mm dia |
| 18 | 100 mm dia |
| 19 | 150 mm dia |
| 20 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 21 | 80 mm dia |
| 22 | 100 mm dia |
| 23 | 150 mm dia |
| 24 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 25 | Stainless Steel (Grade 304) |
| 26 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket |
| 27 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: |
| 28 | Stainless Steel (Grade 304) |
| 29 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: |
| 30 | 2 way-100 mm dia M.S. Pipe |
| 31 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 32 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories |
| 33 | Pendent Sprinkler |
| 34 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 35 | Supplying and fixing hose cabinet of size 900mm x 600x 500mm made of 1.6 mm thick MS sheet with 6mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate 30 mtr- first aid hose reel drum with hose pipe with its accessories mounted on wall OR raised brick plateform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect etc as required. |
| 36 | SITC of Swinging type hose reel complete with 19mm x 30 Mtrs. Thermoplastic hose TypeII with 20 mm nominal internal dia gun metal globe valve & nozzle complete etc as reqd. |
| 37 | SITC Glass sheet of nominal thickness 4 mm with rubber gasket in the existing hydrant boxes |
| 38 | Servicing and repairing of Hose reel drum in existing position etc. complete as reqd. |
| 39 | Servicing the 100 KVA engine operated coupled pump-set by removing the old grease from the bearing and putting new replacing graphite gland, packing, stud and gland pushers etc as required. |
| 40 | Servicing of 55 KW Kirloskar make electric motor coupled Main Fire Pump set by removing the old grease from the bearing and putting new replacing graphite gland, packing, stud and gland pushers etc as required. |
| 41 | Servicing of 15 HP Kirloskar make electric motor coupled Jockey Fire Pump set by removing the old grease from the bearing and putting new replacing graphite gland, packing, stud and gland pushers etc as required. |
| 42 | Repairing and servicing the 10 HP terrace pump motor-pump set by opening of pump casing replacing grease from the bearing, cleaning of impeller and etc complete as required. |
| 43 | Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. |
| 44 | 100 mm diameter pipes |
| 45 | 150 mm diameter pipes |
| 46 | 200 mm diameter pipes |
| 47 | 80 mm diameter pipes |
| 48 | Fire Alarm & PA system |
| 49 | Dismantling & Cleaning of Existing Detector like multi criteria optical smoke cum Heat detectors UL listed / rise cum fixed temparature type heat detector UL listed / Air sampling type / duct smoke detectors UL listed / Addressable UL listed IR beam detector / Addressable manual call point UL listed / Multi-tone hooters with strobe lights UL listed i/c Checking connection of the existing detector installed at various floor of each panel work involve in testing of AFA System etc complete as reqd. |
| 50 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 51 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 52 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 53 | Supplying and laying of 2 x 1.5 sq mm Flexible Cu Conductor cable i/c connection i/c fixing with the help clip/ Gitti or laying above the false ceiling etc. complete as reqd. |
| 54 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. (As is where is basis) (The system should be compatible with the existing AFA system of Edwards make |
| 55 | Supplying, installation, testing & commissioning of intelligent addressable programmable sounder etc complete as required. (As is where is basis) (The system should be compatible with the existing AFA system of Edwards make |
| 56 | Supplying, installation, testing & commissioning of fault isolator complete with base etc complete as required. (As is where is basis) (The system should be compatible with the existing AFA system of Edwards make |
| 57 | Programing, testing and commissioning of Two Panel Adressable Fire Alarm panel (Edwards Make ) with required software and hardware in the all loop of the panel after completion of work at Each floor with the existing fire alarm panel at Fire control room work involve testing of AHUs its tripping with AFA System, in the all existing loop of each panel in the scope of work etc complete as reqd. (Make - Edwards / Existing panel) |
| 58 | Programing, testing and commissioning of Ten Loop Panel Adressable Fire Alarm panel (Edwards Make ) with required software and hardware in the all loop of the panel after completion of work at Each floor with the existing fire alarm panel at Fire control room work involve testing of AHUs its tripping with AFA System, in the all existing loop of each panel in the scope of work etc complete as reqd. (Make - Edwards / Existing panel) |
| 59 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 60 | Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete etc complete as required. |
| 61 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. etc complete as required. |
| 62 | speaker cable Single pair, 2-core, 1.5 sqmm |
| 63 | speaker cable Four pair, 2-core, 1.5 sqmm |
| 64 | Credit of old dismantled material etc as reqd. |
| 65 | Butterfly valve/Sluice valve - 80/100/150 |
| 66 | NRV - 80/100/150 |
| 67 | Air vessel made of 250 mm dia |
| 68 | Pressure swtich |
| 69 | Pendent Sprinkler |
| 70 | MS pipe - 25/65/80/100/150 mm dia |
| 71 | Internal/external Hydrant valve |
| 72 | RRL hose pipe |
| 73 | Swinging type hose reel |
| 74 | Fire Brigade - 2-3 4 way |
| 75 | Hose reel |
| 76 | SS short branch pipe |
| 77 | Analog Addressable photthermal detector |
| 78 | Addressable thermal detector |
| 79 | Programmable sounder |
| 80 | Isolator |
| 81 | Digital audio amplifier |
| 82 | Ceiling/wall mounted Loud speaker |
| 83 | Speaker cable Please Enable Macros to View BoQ information |