| 1 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead Thickness above 25 mm up to 40 mm through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 2 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below, through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas exceeding 30cm in depth,1.5m in width as well as10 sqmon plan) including getting out and disposal of excavated earth lead upto50m and lift upto1.5m,as directed by Engineer-in-charge. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand) : 6 graded stone aggregate 20 mm nominal size) through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) : 6 graded stone ggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and onsolidated and grouted with fine sand, including necessary excavation, levelling & ressing & finishing the top smooth.within all leads and lifts and as per direction of Engineer-in- Charge. |
| 7 | Stone soling properly hand packed filling intersticies with kharanja stone and and consolidating with power road roller to the required gradient and comber including spreading watering and rolling of binding materials moorum or earth etc.complete as per HP.PWDspecifications 100 mm spread thickness (finished work including materials and labour) through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 8 | Providing and laying cement concrete 1:4:8 (One cement : four sand : eight crushed stone aggregate 40mm (Forty millimeter) nominal size) mechanically mixed and vibrated, curing complete excluding cost of form work in foundation and plinth and as per HP. PWD. specifications of 1990 volume-I. including carriage of materials ,labour ,tool and plants through all modes of transportation with in all leads and lifts, and as per direction of the Engineer-in-charge. |
| 9 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 10 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Providing and laying Vitrified tiles in different sizes(thickness to be specified by the manufacturer), withwater absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours nd shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive(water based) conforming to IS: 15477, in average 6 mmthickness, including grouting of joints (Payment forgrouting of joints to be made separately). through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 11 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 12 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 13 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 14 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 15 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 16 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 17 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 18 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 19 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 20 | Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface. 25mm thick through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 21 | Providing and laying second class half brick masonry in common burnt clay building bricks in foundation and plinth with cement mortar 1:4 (One cement : 4 sand)and curing complete including carriage of materials labour ,tool and plants through all modes of transportation as per HP. PWD. specifications of 1990 volume-I.including carriage of materials, labour, tool and plant through all modes of transportation within all leads and lifts and as per direction of Engineer-in- Charge. |
| 22 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete1:6:12 (1cement :6 coarse sand:12 graded stone aggregate 20mmnominal size) atwindowsills, ceiling level and the like. in C.M 1:6 through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 23 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 24 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 25 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premouldedandprepolished, machine cut for kitchenplatforms, vanitycounters,windowsills, faciasandsimilar locationsof requiredsize, approved shade, colour and texture laidover 20mmthickbase cementmortar 1:4 (1cement : 4coarsesand), joints treatedwithwhitecement,mixedwithmatchingpigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm |
| 26 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size) through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inpositionand binding all complete above plinth level through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 28 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983withC.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 10x1040mmbowldepth225 hrough all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 29 | Providing and fixing 18 mm thick, 150 mm wide pelmet of flat ressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mm dia ( heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40mm x 40mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete. trough all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 30 | Providing PVC joints withPVC pipes and fittings of diameter 100 mm within all leads and lifts and as per direction of Engineer-in- Charge. |
| 31 | Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal bore within all leads and lifts and as per direction of Engineer-in- Charge. |
| 32 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 33 | Providing and fixing G.I. pipes complete with G.I. fittingsand clamps, i/c cutting and making good the walls etc 15 mm dia nominal bore internal within all leads and lifts and as per direction of Engineer-in- Charge. |
| 34 | Providing and fixing G.I.pipes complete with G.I. fittingsincluding trenching and refilling etc 15 mm dia nominal bore external within all leads and lifts and as per direction of Engineer-in- Charge. |
| 35 | Making connection of G.I. distribution branch with G.I.main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore within all leads and lifts and as per direction of Engineer-in- Charge. |
| 36 | Providing and fixing brass stop cock of approved quality 15 mm nominal bore within all leads and lifts and as per direction of Engineer-in- Charge. |
| 37 | Providing and fixingG.I. Union inG.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 15 mm nominal bore within all leads and lifts and as per direction of Engineer-in- Charge. |
| 38 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 39 | Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge |
| 40 | Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :35 mm thick shutters Second class teak wood through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 41 | Providing and fixing 8mm dia C.P. /S.S. Jet with flexible tube upto 1metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 42 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 43 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 44 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 45 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 46 | Providing and fixing100 mm sand cast Iron grating for gully trap. through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 47 | Providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :within all leads and lifts and as per direction of Engineer-in- Charge. |
| 48 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 49 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : a) 125mm through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 50 | b)100mm |
| 51 | Providing and fixing ISI marked oxidised M.S. towerbolt black finish, (Barrel type) with necessary screws etc. complete : a) 150x10mm through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 52 | b)100x10mm |
| 53 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 54 | Providing and fixing M.S. BP Sheet 2mm(two milimeter) thick in eaves board/facia/soffits/ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-Charge (Base members of steel work shall be measured and paid separately). as per the direction of Engineer-in-Charge and as per HP.PWD. Specification 1990 volume-I, including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts, including all incidental charges. |
| 55 | Marble work gang saw cut (polished and machine cut) of Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete :12 mm thick through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. |
| 56 | Providing and fixing specified wood frame work consisting of battens 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete.Kiln seasoned and chemically treated hollock wood through all modes of transportion within all leads and lifts and as per direction of Engineer-in- Charge. Please Enable Macros to View BoQ information |