| 1 | Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick, watering, and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and as directed. |
| 2 | Surface dressing n.exc. 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Surface excavation n.exc 30 cm deep and averaging 15cm deep in soft/loose soil and getting out complete all as specified and as directed. |
| 4 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 6 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 7 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 8 | M&L for hand packing broken bricks (any thickness) at back of walls over arches etc and raising (or lowring) as in flooring and plinth protection to the required level complete all as specified and as directed. |
| 9 | M&L for hard core with broken bricks of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 10 | Cutting hole into RCC wall or slab any size or dia n. exc 400 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as per specified and as directed. |
| 11 | M&L for PCC 1:4:8 Type D-2 ( Using 40 mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 12 | M&L for 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 13 | M&L for PCC 1:3:6 Type C-2 ( Using 40mm graded crushed stone aggregate) as in foundation , filling, and mass concrete complete all as specified and directed. |
| 14 | M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed. |
| 15 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in sub base complete all as specified and directed. |
| 16 | M&L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough, lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, etc. including necessary formwork (straight or curved) complete all as specified and as directed. |
| 17 | M&L for 25 mm thick PCC 1:2:4, type B-0, (using 12.5 mm graded crushed stone aggregate) as in levelling Course, floor/paving ect and finished the surface even and fair complete all as specified and as directed. |
| 18 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed. |
| 19 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 20 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in beams, cantilever, lintels over 1.5 m span complete all as specified and as directed. |
| 21 | M&L for RCC M-25 (design mix) (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 22 | M & L for precast RCC cover slab, 1:1.5:3 type A-1,(Using 20 mm graded crushed stone aggregate ) as in drain/manhole cover slab etc., and set in cement mortar 1:4 including necessary form work complete all as specified and as directed. |
| 23 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 24 | Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions (Square, Circular rectangular or polygonal) for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 25 | Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels over 1.5m clear span, cantilevers, shelves including supports overhangs etc also splays between floors and beams for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 26 | Use and waste formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for rough finished surface of concrete complete all as specified and as directed. |
| 27 | Use and waste of form work to edges of concrete flats, roof slab treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for flat, rough finished surfaces complete all as specified and as directed. |
| 28 | M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 29 | M & L for mild steel TMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 30 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 31 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed. |
| 32 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 33 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 34 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 200Ml per bag(50Kg) of cement or as per manufacture's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 35 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 36 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 37 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 38 | M&L for preparation of newly plastered surface of wall, pilasters, cornices etc and treatment apply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer (X2) complete all as specified and as directed.Make: (a) Asian (Apex ultima). Berger weather coat all gaurd. ICI Dulex (Weather shield Max), Nerolac (Excel total) Make of primer : Asin (X2) or Equivalent Note : Each stage i.e Preparation primer application, first coat and second coat of Apex will be passed by Engr-in-Charge (b) Written warranty for four years is required to be furnished by the contractor for this item. |
| 39 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. |
| 40 | Supply only high strength stainless steel (SS-304 or above grade) full thread bent eye bolts, 8mm dia thick with eye 10mm dia and 120mm long with one nut and steel washer complete all as specified and as directed. |
| 41 | Supply only Heavy duty 10mm dia and 10cm length of anchor bolts, typically used for RCC column fixing , each screwed end to be fitted with washers complete all as specified and as directed. |
| 42 | Supply only PVC coated (minimum 2mm coating as per IS-4826) 4mm dia GI wire confirming to IS-280 complete all as specified and as directed. |
| 43 | S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde-E-165 completed all as specified and directed. |
| 44 | M&L for mild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 45 | M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (GdeE- 250) quality A complete all as specified and as directed. |
| 46 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 47 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. |
| 48 | M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and including ceiling section ( not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete including hangers 6 mm dia G I (upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long and fixed or laid 4mm thick non asbestos fibre cement building boards (E-board) with screws complete all as specified and as directed. |
| 49 | M&L for coloured joint free non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc. over and including 15 mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed. |
| 50 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 51 | M&L for machine cut kota stone slab flooring 20 to 25 mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 15 mm thick screed in cement mortar (1:4) including rubbing and polishing complete all as specified and as directed. |
| 52 | M&L for 15mm thick EPDM flooring, certified 100% hygiene and safer for children, long life with 5 yrs warranty, resistance to abrasion, slipping, indentation & ignition, without joints, etc; comprising including laid with approved adhesive prime coat on concrete surfaces and applying 9mm thick standard approved SBR cushioning layer and final 6mm thick colour EPDM layer laid in approved design complete all as specified and as directed. |
| 53 | S & F factory made solid PVC door frame of size 40mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed. |
| 54 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 55 | S & F 100 mm size aluminium alloy with galvanized mild steel hinge pin, anodised and fixed, type B-22 butt hinges, complete all as specified and as directed. |
| 56 | S & F 125 mm size stainless steel butt hinges heavy weight complete all as specified and as directed. |
| 57 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 58 | S&F 610 mm long polished stainless steel handles complete all as specified and as directed. |
| 59 | S & F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed. |
| 60 | S&F powder coated anodised aluminium ventilator with fixed aluminium frame of size 65x40x1.98mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be approved with 4mm thick pin head glass and remaining portion to be covered using 4mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including necessary channel frame work, including rubber gasket and aluminium beading, and make completed all as specified and directed. Note: Rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc. |
| 61 | supply installation of Rain water harvesting filter equipment with self cleaning, handling high flow via 150mm dia pipe (make sintex or Equivalent) complete all as specified and as directed. |
| 62 | S&F 500 litres capacity rotational moulded polye-thylene water storage tanks double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed. |
| 63 | S&F 5000 litres capacity rotational moulded polye-thylene water storage tanks double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed. |
| 64 | Supply and installation of 15000Litre underground FRP water tank complete all as per manufacturer instruction and including necessary civil and plumbing works complete all as specified and as directed. |
| 65 | S&F 25mm bore CPVC ball valve( gate valve) quarter turn , screwed both ends for CPVC pipe or for unions and fixed all complete all as specified and as directed. |
| 66 | Supply & Laying CPVC pipes SDR 11 and plain CPVC SDR-11 fittings on walls/ceiling or laying in floors/concealed in wall of size 20 mm outer dia complete all as specified and as directed. |
| 67 | Supply & Laying CPVC pipes SDR 11 and plain CPVC SDR-11 fittings on walls/ceiling or laying in floors/concealed in wall of size 25 mm outer dia complete all as specified and as directed. |
| 68 | S&F bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 69 | S & F 2 way Bib cock, 15mm dia cast copper alloy chromium plated, with wall flange fancy type, crutch or butterfly handles screwed down for iron pipe or for brass ferrule complete all as specified and as directed. |
| 70 | S&F in repairs, stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe. |
| 71 | S&F fancy type Brass chromium plated 600mm long Towel Rail fixed with screws and wooden/plastic cleats etc. complete all as specified and as directed. |
| 72 | S&F 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 73 | S&F Ultra Bottle Trap 300mm long complete all as specified and as directed.Make: Cera Cat No. F8060406 or equivalent make in Jaquar/Parryware/Prayag/Hindware |
| 74 | S&F liquid soap dispenser Black Matt Finish complete all as specified and as directed.Make: Cera Cat. No. F5013111MB or equivalent make in Jaquar/Parryware/Prayag/Hindware |
| 75 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 20mm outer dia CPVC pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 76 | S&F snow white EWC of size 710mm x 730mm x 770mm one piece including S trap 300mm with soft close seat cover Make cera cat.no B1520118. or equivalent complete all as specified and as directed. |
| 77 | S&F snow white wall hung wash basin of size 665mm x 545mm x 190 mm complete all as specified and as directed. |
| 78 | S&F Clinical single lever clinical faucet with 200 mm lever complete all as specified and as directed.Make: Cera Cat. No. F9030453 or equivalent make in Jaquar/Parryware/Prayag/Hindware |
| 79 | S&F wall mounted garb bar 600mm long complete all as specified and as directed.Make: Cera Cat. No. B2210106 or equivalent make in Jaquar/Parryware/Prayag/Hindware |
| 80 | S&F wall mounted hinge hand rail 750mm x 100mm complete all as specified and as directed.Make: Cera Cat. No. B2210108 or equivalent make in Jaquar/Parryware/Prayag/Hindware |
| 81 | S&F 150 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall complete all as specified and as directed. |
| 82 | M&L for pcc 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed for drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 83 | S&F 150mm dia PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specifiec and as directed. |
| 84 | S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall complete all as specified and as directed. |
| 85 | M&L for pcc 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed for drain pipes 110 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 86 | S & F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed. |
| 87 | S&F 110mm dia PVC (SWR) junction single, (single T) equal or unequal provided complete all as specifiec and as directed. |
| 88 | S & F 110mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 89 | S&F 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints and laid in trenches or in floor/wall complete all as specified and as directed. |
| 90 | S&F 75 mm dia PVC (SWR) bends any radius complete all as specified and as directed |
| 91 | S&F PVC (SWR) pipe 110 mm dia as in weep holes complete all as specified and as directed |
| 92 | S&F 75mm dia PVC (SWR) multi floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 93 | S&F 100mm X 100mm size Salt-glazed stoneware gully trap, square or round mouthed, type, P, complete all as specified and as directed. |
| 94 | M&L for Cutting into existing manholes for connecting new drains of 100 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and as directed. |
| 95 | S & F GI tubing 50 mm bore, medium grade with all fittings, laid in trenches complete all as specified and as directed. |
| 96 | S & F GI tubing 25 mm bore, medium grade with all fittings, laid in trenches complete all as specified and as directed. |
| 97 | S & F 50mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. |
| 98 | S & F 40mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 99 | S & F 40mm bore gun metal globe or gate valve cast copper alloy, screwed down, high pressure with iron wheel head screwed both ends for iron pipe complete all as specified and as directed. Please Enable Macros to View BoQ information |