| 1 | Electrical Installation |
| 2 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 5 Amp Modular Plate And Switch and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. |
| 3 | Group C |
| 4 | supplying and fixing of suitable size GI box with modular plate and cover in front on surface/recess including providing and fixing 25 amps modular socket outlet Sp Mcb “C” curve including connections painting ect. As required. |
| 5 | Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess including providing and fixing 2 nos. 3 pin 5/6 modular socket outlet and 2 nos. 5/6 modular switch connections etc. as required ( For light plugs to be used in non residential buildings) |
| 6 | supplying and fixing of suitable size GI box with modular plate and cover in front on surface/recess including providing and fixing 6 pin 5/6 amp &15/16 amp moduler socket and 15/16 amps modular switch connection As required |
| 7 | supplying and fixing following modular base 7 cover plate on existing modular mattal boxes ect. As required |
| 8 | 8 module |
| 9 | supplying and fixing following modular switch & socketon the exising modular plate & switch box incuding connection but excluding modular plate ect. As required. |
| 10 | 5/6 amps switch |
| 11 | 3 pin 5/6 a socket outlet |
| 12 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-supplying and fixing of suitable size GI box with modular plate and cover in front on surface/recess including providing and fixing |
| 13 | Single pole. Cat-A. |
| 14 | Supplying and fixing following rating following pole 10 KA breaking capacity, 240 -415V DB isolator suitable inductive load in the existing MCB connect,testing and commissioning ect. As required |
| 15 | Double pole. DP MCB 63 A Cat-A. |
| 16 | Double pole. DP MCB 63 A Cat-A. |
| 17 | Supplying and fixing following rating following pole 10 KA breaking capacity, 240 -415V DB (4 poles) resdiule current circuit breaker (RCCB) having a sensitivity current 30ma in the existing MCB connect,testing and commissioning ect. As required ---- 63 Amp |
| 18 | 40 Amp |
| 19 | Wiring for circuit/sub-main along with earth wire following size.HRFRLS/PVC insulated single core copper conductor cable surface/recessed steel conduit in medium class steel conduit as required 2 X 6sq mm + 1x 6 sq mm earth wire . |
| 20 | 2x1.5 Sq. mm. |
| 21 | 2x4.0 Sq. mm. |
| 22 | 4x4 Sq. mm |
| 23 | Installation off ventilating /exhaust fan in the existing opening , including making good BEE 5 star rated ,ceiling fan with Brush less Direct Current ( BLDC) Motor the damage connection, testing , commissioning etc. as required . Supply & Erection of Ventilating Fan) Following size complete with motor, with minimum power consumption , rigid frame with rubber mounting for solent operation , in the existing opening including cost of making the hole to suit the size of above fan making good the damage Carriage Charges connection, testing , commissioning etc, as required to complete the job to the entire satisafcation of ELC. |
| 24 | Exhaust Fan, 250 mm sweep |
| 25 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- |
| 26 | Exhaust Fan, 300 mm sweep 1400/900 RPM |
| 27 | Exhaust Fan, 225 mm sweep 1400/900 RPM |
| 28 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion bolt with nuts and washers. Including embedding of expansion bolts in the wall , providing and fixing of Non-return valve. Dead weight safety valve, 2 no. C.P connections rods 18\\" long making good the damage , electrical connections , safety valves connection , testing and commissioning etc. as required:- |
| 29 | 15 Liter capacity water heater (Cat-A) |
| 30 | 6 Liter capacity water heater (Cat-A) |
| 31 | S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 32 | Specification of LED fittings: |
| 33 | Wattage of LED fittings - As per following parameter. |
| 34 | Total lumens of the fittings - as per wattage |
| 35 | Diffuser - Polycarbonate diffuser/PMMA |
| 36 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 37 | Input frequency - 50 Hz + 1 Hz |
| 38 | Power factor - Minimum 0.90 |
| 39 | Luminaire efficacy - ≥100 lm/w |
| 40 | Color rendering index - CRI shall be greater than 80 |
| 41 | Working/ operating temperature - 00 to + 450c or better |
| 42 | Color temperature - 60000K + 10% |
| 43 | Electronic Driver |
| 44 | Drive current (LED) - As per OEM. |
| 45 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 46 | Type of driver - Constant current output driver |
| 47 | THD - Less than 10% |
| 48 | Surge Protection - 2.5 KV minimum |
| 49 | Efficiency Driver - ≥85% |
| 50 | Protection - Shall have under voltage and over voltage protection. |
| 51 | Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. |
| 52 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 53 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 54 | Life of LED - 25000 burning hours at 70% lumen maintenance |
| 55 | Lumen output of the fitting |
| 56 | LED Batten Light ≥2000Lumens. |
| 57 | LED Batten Light ≥1000Lumens. |
| 58 | Supplying and fixing call/ bell buzzer suitable for single face 230V , complete as required. |
| 59 | S/E of LED Panel with PDC body and polycarbonate /Acrylic diffuser to be mounted in recess The job includes carriage, erection, making connections testing and commissioning of the fittings.2 * 2 feet |
| 60 | Specification of LED fittings: |
| 61 | Wattage of LED fittings - As per following parameter. |
| 62 | Total lumens of the fittings - as per wattage |
| 63 | Diffuser - polycarbonate/acyrlic diffuser UGR <30 |
| 64 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 65 | Input frequency - 50 Hz + 1 Hz |
| 66 | Power factor - Minimum 0.90 |
| 67 | Luminaire efficacy - ≥110 lm/w |
| 68 | Color rendering index - CRI shall be greater than 80 |
| 69 | Working/ operating temperature - 00 to + 450c or better |
| 70 | Color temperature - 60000K + 10% |
| 71 | Electronic Driver |
| 72 | Drive current (LED) - As per OEM. |
| 73 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 74 | Type of driver - Constant current output driver |
| 75 | THD - Less than 10% |
| 76 | Surge Protection - 2.5 KV minimum |
| 77 | Efficiency Driver - ≥85% |
| 78 | Protection - Shall have under voltage and over voltage protection. |
| 79 | Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. |
| 80 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 81 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 82 | Life of LED - 50000 burning hours at 70% lumen maintenance |
| 83 | Lumen output of the fitting |
| 84 | LED Panel Light 2'x2' ≥3300Lumens. |
| 85 | S/E of LED Downlighter(recess)round type with CRCA/PDC body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 86 | Wattage of LED fittings - As per following parameter. |
| 87 | Total lumens of the fittings - as per wattage |
| 88 | Diffuser - Polycarbonate diffuser/PMMA |
| 89 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 90 | Input frequency - 50 Hz + 1 Hz |
| 91 | Power factor - Minimum 0.90 |
| 92 | Luminaire efficacy - ≥100 lm/w |
| 93 | Color rendering index - CRI shall be greater than 80 |
| 94 | Working/ operating temperature - 00 to + 450c or better |
| 95 | Color temperature - 60000K + 10% |
| 96 | Electronic Driver |
| 97 | Drive current (LED) - As per OEM. |
| 98 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 99 | Type of driver - Constant current output driver |
| 100 | THD - Less than 10% |
| 101 | Surge Protection - 2.5 KV minimum |
| 102 | Efficiency Driver - ≥85% |
| 103 | Protection - Shall have under voltage and over voltage protection. |
| 104 | Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. |
| 105 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 106 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 107 | Life of LED - 50000 burning hours at 70% lumen maintenance |
| 108 | LED Down Light ≥2000Lumens. |
| 109 | LED Down Light ≥2400Lumens. |
| 110 | S/E of MCCB 4 Pole with Thermal magnetic Realese for overload and short circuit protection breaking capacity (lcs= 100 % lcu with positive isolation) with/ without Spreader/rotary handle |
| 111 | 40-100 Amps 36 KA release without rotary handle |
| 112 | MCCB 125/160 Amps 36 KA 4 pole release without rotary handle |
| 113 | Providing and fixing of 6 SWG GI wire on surface or in recess for loop earthing as required |
| 114 | Providing and fixing double door, 12 way MCB segregated distribution board, conforming to IS 8623 (Part 1 & 2) / IEC 61439 (Part 1 & 3), fabricated out of CRCA sheet steel, powder coated in RAL 9003 shade, complete with 100A insulated copper phase bus bars, neutral bus bar with shrouds, earth bar, wiring accessories and identification, complete as required. The segregated distribution board shall be suitable for accommodating 1 No. 100A, 36 kA FP MCCB as main incomer, 3 segments for DP MCB / RCCB, and 3 segments for SP MCB outgoing, including all internal wiring, terminations, cable glands, lugs and making all necessary connections, complete in all respects.Approved make: L&T / Havells / Schneider or equivalent, as approved by Engineer-in-Charge. |
| 115 | Providing and fixing double door, 8 way MCB segregated distribution board, conforming to IS 8623 (Part 1 & 2) / IEC 61439 (Part 1 & 3), fabricated out of CRCA sheet steel, powder coated in RAL 9003 shade, complete with 100A insulated copper phase bus bars, neutral bus bar with shrouds, earth bar, wiring accessories and identification, complete as required. The segregated distribution board shall be suitable for accommodating 1 No. 125/160A, 36 kA FP MCCB as main incomer, 3 segments for DP MCB / RCCB, and 3 segments for SP MCB outgoing, including all internal wiring, terminations, cable glands, lugs and making all necessary connections, complete in all respects.Approved make: L&T / Havells / Schneider or equivalent, as approved by Engineer-in-Charge. |
| 116 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required |
| 117 | Armoured cable 25 sq. mm (3.5 core) |
| 118 | Armoured cable 35 sq. mm (3.5 core) |
| 119 | VRV/VRF |
| 120 | Supply, Installation, Testing & Commissioning of factory fitted mircoprocessor based self diagnostic auto check VRV/VRF system outdoor unit equiped with PCBs, accumulator, oil seperator, burshless DC inverter fan motor, OEM self manufactured hermetic sealed multi valve scroll type compressors. Compressor should be based on low pressure shell technology for longer life with integrated IPM & PWM to ensure effective operation even at low/partial load conditions for better efficiencies. Compressor shall be fixed in metallic chamber for lower noise with enhanced fire saftey protection. Outdoor unit shall be equiped with highly efficient induction type heater using eliminated wasted heat. VRT/VET system shall be based on advanced & automatically modulation evaporating refrigerant temperature between 0°C to 11°C for instant cooling and better energy effiency as per user's demand. Outdoor units shall be essentially equiped with saftey devices like fuse, noise filter PCB, low pressure switch, high pressure switch, pulse based LEV for optimized refrigerant flow control, isolating valve, protective corrosion resistant polyster coating on panels, hydrophilic coating on Aluminium fins, protective polyeurethane coating on PCB, OEM provided Inbuilt automatic reverse phase detector & sequencer/corrector to avoid any kind of failure due to phase sequence reversal which makes system relaible and redundant. Heat exchanger must be essentially equiped with internally grovved copper tubes for better heat exchange performance and operate in extreme conditions i.e. even at ambient temparature of 52°C or more. |
| 121 | Outdoor units shall be pre-charged with R401A gas, pump down fucntion and shall also be equipped with charging valve/ports for additional charge of refrigerant as per site requirement. All outdoor unit shall be able to perform in duty cycle mode to optimize wear and tear of system when more than one outdoor unit is connected to a circuit. Outdoor units must also be equiped with four way valve for necessary provision of heating during winters. All outdoor shall have approximately following as per OEM standards rated capacities at ARI conditions and, with the criteria of delivering 95% capacity at 43 °C being most likey temperature to occur during summers. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required)The manufacturer of ODU and compressor shall be same. i.e. the make of compressor shall be identicle of the ODU.Make : Daikin, O General, Mitsubhishi .Nominal Capacity in HP as stated below: |
| 122 | Outdoor Unit -10 HP |
| 123 | Indoor Units:HI Wall Indoor Type |
| 124 | Supply, Installation, Testing and Commissioning of VRV/VRF indoor units with factory fitted electronic expansion valve, multi speed fan motors, dynamically balanced blowers, synthetic washable plasma media filter with hydrophobic coating on cooling coil. Electronic components like PCBs must be essentially enclosed in a metal box compartment being integrated part of indoor unit to ensure enhanced fire protection with auto by pass technology allowing uninterupted operation of indoor units connected to a circuit in event of break down in any indoor connected to same circuit. All indoor units shall have individual fan speed and temperature control mechanism to be operated from corded/cordless remote. In addition to all indoor units can also be operated from central remote control. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required) |
| 125 | HI Wall Type Indoor Unit -1.6 TR |
| 126 | HI Wall Type Indoor Unit -2.0 TR |
| 127 | Supply and installation of refrigerant piping Y-joints / T-joints / headers, as required for interconnection of VRV/VRF outdoor units with indoor units, suitable for both liquid and gas lines as one complete set, made of factory-fabricated copper fittings compatible with specified refrigerant, including cutting, brazing with nitrogen purging, pressure testing, insulation continuity, supports, and all necessary accessories, complete in all respects as per manufacturer’s recommendations and directions of Engineer-in-Charge. |
| 128 | Supply, installation, testing and commissioning of corded remote controller, compatible with VRV/VRF indoor unit, complete with wall mounting, control wiring, programming, addressing, testing and commissioning, including all required accessories and making the system complete in all respects and directions of Engineer-in-Charge.Make : Daikin , O General, Mitsubhishi |
| 129 | Providing and charging of refrigerant R-410A, including supply of refrigerant, evacuation, vacuuming, pressure testing, topping-up / additional charging as required for the complete VRV/VRF air-conditioning system, complete in all respects as per manufacturer’s recommendations and directions of Engineer-in-Charge. |
| 130 | Drain Piping: |
| 131 | Supply, installation, testing and commissioning of rigid PVC drain water piping, minimum 15 kg/cm² pressure rated, complete with all required fittings such as bends, elbows, tees, reducers, sockets, clamps, supports, jointing material and all accessories required to make the system complete in all respects, including fixing on wall/ceiling/floor as required. |
| 132 | 25 mm ( with 9 mm Class- O XLPE) |
| 133 | Copper Refrigerant Piping with Insulation for VRV System: |
| 134 | Supply, installation, testing and commissioning of copper refrigerant piping for VRV/VRF air-conditioning system, complete with all fittings such as bends, elbows, tees, reducers, headers as required, supports, clamps, jointing by brazing with nitrogen purging, pressure testing, evacuation, gas charging and commissioning, including Class ‘O’ XLPE insulation of required thickness, and all accessories required to make the system complete in all respects, as per manufacturer’s specifications and directions of Engineer-in-Charge. Nominal Dia in mm OD as indicated below :Make : Rajco/Maxflow/Mandev/Jobu/MTL |
| 135 | 22.2 ( with 19 mm insulation ) |
| 136 | 15.9 (with 13 mm insulation) |
| 137 | 12.7( with 19 mm insulation ) |
| 138 | 9.5 (with 13 mm insulation) |
| 139 | 6.4 ( with 13 mm insulation ) |
| 140 | CONTROL CABLING |
| 141 | Providing and fixing control-cum-transmission wiring consisting of 2 core × 1.5 sq.mm copper conductor cable, drawn through suitable PVC conduit / casing–capping / flexible conduit as required, for interconnection between VRV/VRF indoor units and outdoor units and between indoor units and remote controllers, including cutting, chasing, saddling, termination, ferruling, testing and making connections complete in all respects as per manufacturer’s recommendations and directions of Engineer-in-Charge. |
| 142 | Supply and fixing of perforated cable tray, made of CRCA / GI sheet of indicated thickness, painted with approved colour, of required width and depth, complete with all accessories such as bends, tees, reducers, risers, coupling plates, nuts, bolts, washers, and including supporting structure / hangers / brackets as required, fixed on wall/ceiling/floor, complete in all respects as per specifications and directions of Engineer-in-Charge. |
| 143 | 150mm wide & 50mm deep x 1.6mm thickness |
| 144 | Central Heating and Fire Alaram |
| 145 | Providing, fixing, testing and commissioning of hot water piping, including all fittings such as elbows, bends, tees, reducers, unions, flanges etc., complete with MS clamps, hangers, supports and anchor fasteners, as required.Pipes shall be black mild steel, Class ‘C’, ISI marked, conforming to relevant IS specifications.The rate includes cost of all supports and hangers, including wooden blocks/isolators at support points under insulation, wherever required, complete in all respects.Piping shall be insulated with nitrile rubber insulation of 15 mm thickness, including adhesive, vapour barrier, sealing of joints, finishing and all necessary accessories, complete as required. |
| 146 | 38 mm dia MS pipe with 15 mm thick nitrile rubber insulation |
| 147 | 32 mm dia MS pipe with 15 mm thick nitrile rubber insulation |
| 148 | 25 mm dia MS pipe with 15 mm thick nitrile rubber insulation |
| 149 | 19 mm dia MS pipe with 15 mm thick nitrile rubber insulation |
| 150 | Supplying, installation, testing and commissioning of a factory-built cabinet type, wall-mounted, single-skin hot water fan coil unit suitable to deliver the required heat output at 60°C inlet water temperature, complete with centrifugal blower mounted on a double shaft motor operating on single phase 230 V, 50 Hz AC supply. The unit shall be provided with copper tube aluminium tinned hot water coil, drain pan, washable inlet air filter made of synthetic media, speed control, and aluminium grille on both inlet and outlet air side. It shall also include 3/4” brass ball valve with strainer on the inlet and 3/4” brass ball valve on the outlet, along with all necessary fittings and connections as required to make the FCU fully functional. Make: Rapidcool / Gaps LTI / Dynaflow. |
| 151 | 3000 KCAL |
| 152 | 4500 KCAL |
| 153 | Providing and fixing brass valve set, size 19 mm × 5/8 inch, with integral strainer, having one side flare end and the other side socket end, suitable for working temperature up to 95°C, with PTFE (Teflon) seat, complete in all respects, as required. |
| 154 | Supply, installation, testing and commissioning of gate valves, sluice valves or globe valves with flanged or screwed ends as required. Valves of 65 mm size and above shall be of cast iron IBR 86 body, Grade A, with flanged ends and gunmetal trim, yoke type with rising stem, pressure rating PN 1.6, including matching flanges. Valves up to 50 mm size shall be of gunmetal, with flanged ends, non-rising stem, integral seat, complete in all respects as required. Make: Kirloskar / Sant / Puri / Leader. |
| 155 | 38 mm |
| 156 | 19 mm |
| 157 | Providing, supplying, installation, testing and commissioning of optical / photoelectric type smoke detector, addressable (digitally addressable) type, with photo-optic sensing chamber, suitable for operation on 12/24 Volts D.C., complete with visual alarm indication through LED (blinking type), including detector base, mounting arrangements and all required accessories, complete as required. Make: ASES / System Sensor or equivalent, as approved by Engineer-in-Charge. |
| 158 | Providing, supplying, installation, testing and commissioning of fixed temperature-cum-rate of rise type heat detector, addressable (digitally addressable) type, suitable for operation on 12/24 Volts D.C., complete with visual alarm indication through LED (blinking type), including detector base, mounting arrangements and all required accessories, complete as required.Make: ASES / System Sensor or equivalent, as approved by Engineer-in-Charge. |
| 159 | Providing, supplying, installation, testing and commissioning of resettable type addressable manual call point, complete with visual indication through LED (blinking type in standby condition), including mounting accessories and all required fittings, as per specifications, complete as required. Make: Agni Suraksha (ASES) or equivalent, as approved by Engineer-in-Charge. |
| 160 | Providing, supplying, installation, testing and commissioning of microprocessor-based, digitally addressable fire alarm control and indicating panel, having addressable features, complete with LCD display, suitable for operation with addressable devices.The panel shall provide distinct visual indication for isolation of any zone from the local indication panel. In case all zones at the local panel are isolated or the fuse of the local control panel (LCP) blows, the same shall result in open circuit fault indication at the main control panel.Each zone shall have provision for activation of hooter, including making all necessary connections, interconnections and terminations, complete as required. Make: ASES / System Sensor or equivalent, as approved by Engineer-in-Charge. |
| 161 | 2 zone panel |
| 162 | Supplying and laying of 2 × 1.5 sq mm fire survival armoured cable, rated for 600/1000 Volts, with annealed copper conductor, LSZH inner bedding, and steel wire armouring, including pulling, laying in trenches / trays / conduits, dressing, clamping and identification, complete as required. |
| 163 | Interactive AV System |
| 164 | Supply, Installation, Testing & Commissioning of EDLA AI Certified 4K Ultra HD 98” Interactive Display Panel, support full channel 4K UI display, 4mm AG tempered glass, Resolution : 3840 (H) × 2160 (V) Pixel Pitch : 0.5622 (W) x 0.5622(H) Frequency : 60Hz Display Color : 1.07B (10bit) Color Gamut (Typ) : 72% Contrast Ratio : 4000:1, Brightness - Up to 450cd/m2, Backlight Life : ≥50000hrs Speakers Soundtrack : 2.0 Speaker Power : 2×20W, Technology : IR Touch Point : 40 points touch, System Version : Android 14.0 Working Frequency : 1.5GHZ CPU : Quad Core A73 GPU : G52 RAM+ROM : 8 + 128GB, Bluetooth Version : 5.2 Operation Frequency : 2.4GHz Operation Distance : 0~10m Remark : Built-in Bluetooth, Wi-Fi Version : 802.11ac/b/g/n/ax Operation Frequency : 2.4GHz/5GHz Operation Distance : 0~10m Remark : Built-in Wi-Fi Front Interface USB 3.0 : 2 HDMI IN : 1 TOUCH USB : 1 TYPE-C : 1(with USB function only, optional full function with 65W PD) Keys : 1× Power Button, Onboard Interface TF : 1 USB 2.0 : 1 USB 3.0 : 1 TOUCH USB : 1 HDMI IN 1 : 2 (1 ARC) RS232 : 1 LINE OUT : 1 COAX : 1 3.5MM Jack : 1 RJ45 IN : 1 etc. Make: LG/Barco/Christie/Sony. |
| 165 | Supply, Installation, Testing & Commissioning of Self-powered audio mixer including 3x MIC/LINE ST and 1x LINE ST input. It features a 95W powered mono output that supports both low (4Ω) and high impedance (70/100V) loudspeaker lines, with 2-ZONE ON/OFF switches. Includes audio priority system, pager (1 zone), phantom, 2 band tone control, auto stand-by, MUTE port and universal power supply unit Make: Ecler/Tecnare/switchaudio |
| 166 | Supply, Installation, Testing & Commissioning of 2 Way On Wall Speaker , 6.5\\" Ployproplene LF Driver + 1\\" Titanium Dome HF, Power : 50 watts cont @8 Ohms, 100v Line: 30W, 15W, 8W, 4W. Freq Response : 58Hz - 20kHz , Sensitivity : 90dB @1W / 1M Make: Ecler/Tecnare/Switchaudio |
| 167 | Supply, Installation, Testing & Commissioning of of wireless UHF handheld /Lapel microphone transmitter, with UHF receiver . Make: Ecler/Shure/ Clockaudio |
| 168 | Supply, Installation, Testing & Commissioning of Desktop PCIntel® Core™ i5-6500 with Intel HD Graphics 530 Processor Windows 7 Professional 4GB RAM / 500GB HDD with keyboard and mouse Make: HP/Dell/Asus |
| 169 | Supply, Installation, Testing & Commissioning of of Speaker cable in existing conduits Make: MX/Falcon/Krystal Please Enable Macros to View BoQ information |